Plan Review Stops For Permit 03061497 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-11-29 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-11-29 |
Time |
11:32 |
Rev Time |
1.00 |
Received By |
sthyng |
Date |
2003-11-29 |
Time |
11:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-11-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-26 |
Time |
10:38 |
Rev Time |
2.00 |
Received By |
sthyng |
Date |
2003-11-17 |
Time |
15:08 |
Sent To |
|
|
Notes |
2003-11-17 00:00:00 | IMPACT FEES |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-07-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-11-12 |
Time |
13:42 |
Rev Time |
2.00 |
Received By |
sthyng |
Date |
2003-07-10 |
Time |
12:06 |
Sent To |
Z |
|
Notes |
2003-07-10 00:00:00 | *****CORRECTIONS****** | | | | 1.)PROVIDE A SURVEY FOR THIS JOB. | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY.THE PLANS MUST BE | | STAMPED AND THE ORIGINAL RECEIPT | | ATTACHED TO THE APPLICATION.233-5025 | | | | 3.)A NOTICE OF COMMENCEMENT MUST BE | | FILED WITH THE CLERK OF COURTS BEFORE A | | PERMIT CAN BE ISSUED. | | | | 4.)SEPARATE PERMITS REQUIRED. | | | | 5.)PAGE SP SHOWS A NEW WALL, FOYER, | | VERANDA, AND COLUNNADE.A4 SHOWS NEW | | STORAGE AND NEW CANTINA. THE APPLICATION | | DESCRIPTION IS FOR A STORAGE ROOM. MAKE | | ALL THREE CONSISTENT WITH THE SCOPE | | OF WORK COVERED UNDER THIS PERMIT. | | | | 6.)WATERSTOP REQUIRED 1 1/2" PER | | CITY OF WPB AMENDMENTS TO THE FBC2111.1. | | 9. | | | | 7.)SHOW THE FIRESTOP, INSULATION AND | | DRYWALL ON THE WALL SECTION IF THE | | CANTINA OR STORAGE ARE TO HAVE DRYWALL. | | | | 8.)PROVIDE AREA CALCULATIONS - | | EXISTING AND PROPOSED CONDITIONED AND | | UNCONDITIONED SPACE. | | | | 9.)PROVIDE A ROOF FRAMING PLAN | | FBC104.3.1.1. | | | | 10.)PROVIDE THE DIMENSIONS ABOVE AND | | BELOW GRADE FOR THE FOUNDATION, TYPICAL | | SECTION, A4. | | | | 11.) THE RENOVATION PERMIT #00060130 FOR | | THIS PROPERTY IS EXPIRED.PLEASE | | ADDRESS. | | | | 12.) PER LOU HATTEN, CHIEF STRUCTURAL | | INSPECTOR, IN REGARDS TO THE PRIVACY | | WALL, EITHER REMOVE THE STEEL AND FORMS | | AND BACKFILL THE EXCAVATED AREA, OR | | APPLY FOR A PERMIT TO DO THIS WORK. | | THIS MAY BE INCLUDED IN THIS PERMIT IF | | IT IS CLEARLY SHOWN ON THE SURVEY AND | | SITE PLAN, AND STRUCTURAL DETAILS ARE | | PROVIDED.PROOF THAT THE PROPERTY THAT | | THE WALL SITS ON IS OWNED BY YOU MUST | | ALSO BE PROVIDED. | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-11-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-11-12 |
Time |
13:42 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-11-12 |
Time |
12:15 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-07-08 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-10 |
Time |
16:20 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-07-08 |
Time |
14:31 |
Sent To |
P |
|
Notes |
2003-07-08 00:00:00 | ****************** UNSAT *************** | | | | 1)NOTE: PLEASE CLARIFY IF AHU/WH IN | | STORAGE IS NEW OR BEING RELOCATED? | | IF NEW, PROVIDE INFORMATION AND LOAD | | CALCULATIONS. | | | | 2)NOTE: PLANS ARE NOTED TO SEE E-SHEETS | | FOR ELECTRICAL LAYOUT? NO E-SHEETS WERE | | SUBMITTED FOR REVIEW. | | | | 3)NOTE: PLANS ARE ALSO SHOWING NEW FOYER | | /VERANDA'S AND CANTINA WITH NOTHING | | SUBMITTED FOR REVIEW? | | EGRESS LIGHTING? GFI RECEPTS? ETC | | 210-8/210-70 | | | | PLEASE NOTE, THERE MAY BE FURTHER | | COMMENTS, DUE TO THE PLANS NOT BEING | | COMPLETE AT THIS TIME. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-11-26 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-26 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-26 |
Time |
10:38 |
Sent To |
B |
|
Notes |
2003-11-26 00:00:00 | TO ST DESK SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-11-10 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-10 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-10 |
Time |
16:20 |
Sent To |
E |
|
Notes |
2003-11-10 00:00:00 | TO BT DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-11-05 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-11-10 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-05 |
Time |
14:16 |
Sent To |
Z |
|
Notes |
2003-11-05 00:00:00 | TO Z/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-10-31 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2003-10-31 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
2003-10-31 |
Time |
09:43 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-24 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-24 |
Time |
16:46 |
Sent To |
E |
|
Notes |
2003-10-24 00:00:00 | TO Z/RESUB |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2003-07-07 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-07-07 |
Time |
15:55 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-07-07 |
Time |
15:55 |
Sent To |
E |
|
Notes |
2003-07-07 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | REVIEW.PLEASE INDICATE HOW STORAGE | | ROOM WILL BE VENTILATED AND WHAT WILL | | BE STORED IN THIS SPACE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2003-07-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-07-08 |
Time |
14:32 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2003-07-09 |
Time |
15:16 |
Sent To |
B |
|
Notes |
2003-07-09 00:00:00 | NO PLUMBING PLANS SUBMITTED - EWH IN NEW | | EQUIPMENT ROOM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2003-11-10 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-11-10 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2003-11-10 |
Time |
10:42 |
Sent To |
I |
|
Notes |
2003-11-10 00:00:00 | 11/10/03 OK PER GRACE JOYCE MM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2003-11-05 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-05 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2003-11-05 |
Time |
12:25 |
Sent To |
|
|
Notes |
2003-11-05 00:00:00 | 11/5/03 CANNOT HAVE STORAGE IN FRONT OF | | PROPERTY CALLED OWNER LEFT MSG FILE R MM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2003-10-29 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2003-10-31 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-10-29 00:00:00 | 10/29/03 DENIED, NEED TO PROVIDE 2 COPY | | OF SURVEY SHOWING THE WORK OF THE JOB | | CALLED OWNER LEFT MSG MM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2003-07-10 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-27 |
Time |
11:14 |
Rev Time |
1.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-07-10 00:00:00 | 7/10/03 SITE PLAN TO BE CLEAR TO SCOPE | | OF WORK & 2 COPY OF SURVEY CALLED CONTR | | MM |
|
|