Plan Review Stops For Permit 03061290 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-08-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-08-07 |
Time |
14:42 |
Rev Time |
1.05 |
Received By |
jwitmer |
Date |
2003-08-07 |
Time |
14:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-07-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-07-14 |
Time |
07:43 |
Rev Time |
0.75 |
Received By |
jwitmer |
Date |
2003-07-14 |
Time |
07:43 |
Sent To |
|
|
Notes |
2003-07-14 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 03061290 | | ADD: 2491 OKEECHOBEE BLVD SIUTE "E" | | CONT: LEIGHTEN MCGINN | | TEL: (561)722-9696 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1)FL BLD CODE 104.2.1.2 | | ADDITIONAL INFORMATION REQUIRED, | | INFORMATION ON THE SECURITY GRILL, MAN- | | UFCTURERS SPEC. LBS/ FT | | | | 2)FIGURE 1606 WIND-BORNE DEBRIS | | REGION; INDICATES THAT W.P.B. CITY OF IS | | LOCATED IN THE 140 MPH ZONE. PLANS ARE | | TO INDICATE THIS. | | | | 3)FL. BLD CODE 1606.1.7 THE FOLLOWING | | INFORMATION RELATED TO WIND SHALL BE | | SHOWN ON THE CONSTRUCTION DRAWINGS, | | 1)- BASIC WIND SPEED, MPH | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | CATEGORY | | 3)- WIND EXPOSURE | | 4)- INTERNAL PRESSURE COEFFICIENT, | | 5)- COMPONENTS & CLADDING, THE DESIGN | | WIND PRESSURES IN TERMS OF PSF. | | | | PLANS INDICATE (1) NEW DOOR IN THE FRONT | | AND (1) NEW DOOR TO THE REAR. | | | | 4) FL BLD CODE 1606.1.5: COMPONENTS & | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | TESTING REPORT, SBCCI OR DADE COUNTY | | REPORT ARE ACCEPTED. MISSING REPORTS: | | A) NEW FRONT DOOR GLAZED | | B) NEW REAR DOOR | | | | 5) 1707.4.3 EACH EXTERIOR DOOR | | ASSEMBLY NOT COVERED BY 1707.4.2 | | (GLAZED DOORS) SHALL BE LISTED AND TEST- | | ED FOR A PERIOD EQUAL TO THE QUANITY | | 3600/ V WHERE THE TIME PERIOD IS IN | | SECTIONS AND V IS IN MILES PER HR TAKEN | | FROM FIGURE 1606. THE TIME PERIOD SHALL | | ALSO INCLUDE A 10 SECOND PERIOD AT A | | LOAD EQUAL TO 1.5 TIMES THE DESIGN | | PRESSURE. DADE COUNTY & SBCCI REPORTS | | ARE ACCEPTED. | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | ON THE APPLICATION, PLANS, OR ATTACHED | | SEPARATELY. WHEN RESUBMITTING PLANS | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | JIM WITMER | | BUILDING PLAN REVIEW | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-07-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-07-07 |
Time |
06:31 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
2003-07-07 |
Time |
06:31 |
Sent To |
|
|
Notes |
2003-07-07 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 03061290 | | ADD: 2491 OKEECHOBEE BLVD | | CONT: LEIGHTON MCGINN | | TEL: (561)722-9696 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | ACTION: DENIED | | | | 1) 1025.1(3) SINGLE EXIT, MAXIMUM TRAVEL | | DISTANCE OF TRAVEL TO THE EXIT DOES NOT | | EXCEED 50 FT. | | | | 2)FL BLD CODE 104.2.1.2 | | ADDITIONAL INFORMATION REQUIRED, | | PROVIDE ADDITIONAL INFORMATION ON SECUR- | | ITY GRILLE, MANUFACTURERS SPEC. LBS/ FT. | | | | 3)FIGURE 1606 WIND-BORNE DEBRIS | | REGION; INDICATES THAT W.P.B. CITY OF IS | | LOCATED IN THE 140 MPH ZONE. PLANS ARE | | TO INDICATE THIS. | | | | 4)FL. BLD CODE 1606.1.7 THE FOLLOWING | | INFORMATION RELATED TO WIND SHALL BE | | SHOWN ON THE CONSTRUCTION DRAWINGS, | | 1)- BASIC WIND SPEED, MPH | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | CATEGORY | | 3)- WIND EXPOSURE | | 4)- INTERNAL PRESSURE COEFFICIENT, | | 5)- COMPONENTS & CLADDING, THE DESIGN | | WIND PRESSURES IN TERMS OF PSF. | | | | 5)FL BLD CODE 1606.1.5: COMPONENTS & | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | TESTING REPORT, SBCCI OR DADE COUNTY | | REPORT ARE ACCEPTED. MISSING REPORT: | | A) FRONT ENTRY DOOR. | | B) LARGE MISSLEIMPACT TESTING FOR NEW | | DOOR OR STORM SHUTTER | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | ON THE APPLICATION, PLANS, OR ATTACHED | | SEPARATELY. WHEN RESUBMITTING PLANS | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | JIM WITMER | | BUILDING PLAN REVIEW | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-08-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-08-06 |
Time |
07:15 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-08-06 |
Time |
07:15 |
Sent To |
|
|
Notes |
2003-08-06 00:00:00 | *********** NOTE ************ | | PLEASE STILL SEE REDLINE FOR 250-24 | | PLEASE ALSO SEE NOTE FROM PREVIOUS | | REVIEW: PLEASE REMOVE ALL OLD/VOIDED | | SHEETS AND HAVE TWO CLEAN COMPLETE SETS | | FOR REVIEWING AND STAMPING. | | OLD SHEETS TO BE SEPARATE AND ONLY ONE | | SET OF THOSE SHEETS MAY BE NEEDED BY | | OTHER PLAN REVIEWERS? | | | | IF THERE ARE ANY QUESTIONS,PLEASE CALL. | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-07-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-07-28 |
Time |
10:24 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-07-28 |
Time |
10:24 |
Sent To |
|
|
Notes |
2003-07-28 00:00:00 | PLEASE TAKE OUT OLD/VOIDED SHEETS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-07-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-07-02 |
Time |
07:56 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-07-02 |
Time |
07:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2003-08-08 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2003-08-08 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-08-08 |
Time |
11:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2003-07-29 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-07-29 |
Time |
17:24 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-07-29 |
Time |
17:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2003-07-08 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2003-07-08 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-07-08 |
Time |
14:54 |
Sent To |
|
|
Notes |
2003-07-08 00:00:00 | *************PROVISO******************** | | SEPARATE SHOP DRAWING AND PERMIT | | APPLICATION ARE REQUIRED FOR FIRE ALARM | | SYSTEM REMODEL. | | | | NATE MCCRAY, CAPTAIN | | 805-6722 OR 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-07-31 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-31 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-31 |
Time |
08:33 |
Sent To |
|
|
Notes |
2003-07-31 00:00:00 | TO COMM BD #4 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-07-11 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-11 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-11 |
Time |
15:23 |
Sent To |
|
|
Notes |
2003-07-11 00:00:00 | COMM BOARD #2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-06-17 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-17 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-17 |
Time |
16:20 |
Sent To |
|
|
Notes |
2003-06-17 00:00:00 | COMM BOARD #27 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-07-07 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-07-07 |
Time |
11:00 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2003-07-07 |
Time |
10:36 |
Sent To |
|
|
Notes |
2003-07-07 00:00:00 | MECHANICAL PERMIT 03061294 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-07-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-07-26 |
Time |
08:21 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-07-26 |
Time |
08:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-07-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-07-02 |
Time |
16:50 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-07-02 |
Time |
16:50 |
Sent To |
|
|
Notes |
2003-07-02 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | FBC-2001 AMENDMENTS, CHAPTER | | 1, ADMIN. CODE | | | | 1) SHT A-1 TABLE 403.1 A DRINKING FOUNT- | | AIN IS REQUIRED. SEE TABLE 410.1 ALSO. | | 2) SHT A-2 SECTION 909.1 ONLY THE FIX- | | TURES WITHIN THE BATHROOM GROUP SHALL | | CONNECT TO THE WET-VENTED HORIZONTAL | | BRANCH DRAIN. ANY ADDITIONAL FIXTURES | | SHALL DISCHARGE DOWNSTREAM OF THE WET | | VENT. (SEE RED LINE CORRECTIONS SHT A-2) | | 3) SUBMIT A WATER RISER DIAGRAM. SECTION | | 104.2.1 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|