Plan Review Details - Permit 03060700
Plan Review Stops For Permit 03060700
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-09-22 Cont ID  
Sent By sthyng Date 2003-09-22 Time 14:55 Rev Time 0.50
Received By sthyng Date 2003-09-22 Time 14:54 Sent To  
Notes
2003-09-22 00:00:00REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-08-19 Cont ID  
Sent By jwitmer Date 2003-08-19 Time 14:14 Rev Time 0.25
Received By jwitmer Date 2003-08-19 Time 14:14 Sent To  
Notes
2003-08-19 00:00:00REVISION # 3OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-08-19 Cont ID  
Sent By kstevens Date 2003-08-11 Time 11:23 Rev Time 0.25
Received By jwitmer Date 2003-08-19 Time 14:10 Sent To  
Notes
2003-07-24 00:00:00BUILDING PROVISO
  
 1) STRUCTURE IS LOCATED IN AN "AO" FLOOD
 ZONE AN ELEVATION CERTIFICATE WILL BE
 REQUIRED.
  
 2) SUBMIT A RECORDED COPY OF THE AMENDED
 SUBDIVISION COVENENTS, WHICH INDICATE
 THAT AN EGRESS EASEMENT ACROSS THE
 ADJACENT PROPERTY ON THE ZERO LOT LINE
 SIDE OF THE STRUCTURE WILL BE PROVIDED.
 THIS IS REQUIRED BEFORE A CERTIFICATE OF
 OCCUPANCY WILL BE.
  
 3) SUBMIT REVISED COMPONENT AND CLADDING
 WINDLOADS BASED ON EXPOSURE CATEGORY B.
  
 4) PROVIDE A CURRENT PRODUCT APPROVAL
 FOR THE HORIZONTAL SLIDING WINDOW.
  
 5) SUBMIT A KEY PLAN AND A REVISED
 INSTALLATION SCHEDULE FOR THE STORM
 PANELS PRIOR TO INSTALLATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-07-07 Cont ID  
Sent By rregueir Date 2003-06-28 Time 13:28 Rev Time 4.00
Received By rmcdouga Date 2003-07-07 Time 12:34 Sent To  
Notes
2003-07-07 00:00:00BUILDING DENIED
  
 1) THE STRUCTURE IS LOCATED IN AN "AO"
 FLOOD ZONE AN ELEVATION CERTIFICATE WILL
 BE REQUIRED.
  
 2) ONE HOUR FIRE RATED GLASS BLOCK IS
 REQUIRED ON THE ZERO LOT LINE. PLEASE
 REVISE ON PLAN AND SUBMIT MANUFACTURER'S
 SPECIFICATIONS AND LISTING INFORMATION
 FOR ONE HOUR FIRE RATED GLASS BLOCK.
  
 3) THE DOUBLE FRONT DOOR DOES NOT COMPLY
 WITH EGRESS REQUIREMENTS. EXIT DOOR MUST
 BE OF THE SIDE SWINGING TYPE WITH A MIN.
 CLEAR OPENING OF 32". SEE FBC TABLE 1004
 AND SECTIONS 1003.2.3.1 AND 1012.1.
  
 4) AN EGRESS EASEMENT TO AND FROM THE
 EMERGENCY ESCAPE AND RESCUE OPENING
 THROUGH THE ADJOINING PROPERTY TO THE
 PUBLIC WAY ON THE ZERO LOT LINE SIDE IS
 REQUIRED AND SHALL BE RECORDED IN THE
 COUNTY RECORDS. THIS EASEMENT SHALL BE A
 MINIMUM OF 3 FEET WIDE AND NOTHING SHALL
 BE PLACED WITHIN THE EASEMENT AREA WHICH
 WOULD BLOCK ACCESS TO THE EASEMENT AND/
 OR IMPEDE EGRESS TO AND FROM THE ESCAPE
 AND RESCUE OPENING. NO LANDSCAPING,
 FENCES OR OTHER IMPEDIMENTS SHALL BE
 INSTALLED IN THIS EASEMENT.
  
 5) PLEASE REVISE DETAIL 1 ON A3.01,
 WHICH SPECIFIES THE DRYWALL ON THE
 CEILING ATTACHED WITH NAILS TO METAL
 FURRING. IT ALSO STATES THAT ROOF
 SHEATHING BE SECURED 4" O.C. AT LEDGES.
 THIS SHOULD BE THIS BE EDGES.
  
 6) PLEASE REVISE DETAIL 5 ON A3.01, OPEN
 VALLEY LINING SHALL BE AT LEAST 11" WIDE
 PER FBC 1507.4.9 OR MANUFACTURER'S
 SPECIFICATIONS.
  
 7) PLEASE REVISE DETAIL 4 ON S4, WHICH
 SPECIFIES A 3/4" WEDGE ANCHOR INTO THE
 TRUSS WERE A THROUGH BOLT SHOULD BE.
  
 8) PLEASE REVISE THE ENERGY CALCULATION
 FORM. THE CONDITIONED FLOOR AREA ON THE
 FORM DOES NOT MATCH THE A/C AREA LISTED
 ON THE PLANS. THE JURISDICTION # ON THE
 FORM IS INCORRECT. THE NUMBER IS 604700
 FOR THE CITY OF WPB.
  
 9) THE PRODUCT APPROVAL FOR THE
 HORIZONTAL SLIDING WINDOW IS EXPIRED.
  
 10) SUBMIT A KEY PLAN FOR THE STORM
 PANELS. THE STORM PANEL SCHEDULE THAT
 WAS SUBMITTED CONTAINS ERRORS. THE
 MINIMUM PANEL LENGTH FOR DIRECT MOUNT AT
 THE TOP AND BOTTOM IS 46" PER TABLE 5 ON
 THE PRODUCT APPROVAL. CALK-IN ANCHORS
 CAN NOT BE USED IN HOLLOW CONCRETE BLOCK
 FOR C1 TYPE CONNECTIONS. SEE ANCHOR
 SCHEDULE ON SHEET 8 OF PROD. APP. NOTE:
 THE ANCHORS ARE REQUIRED TO BE IN 2500
 PSI CONCRETE AND NOT IN THE STUCCO OR
 THE BLOCK.
  
 11) THE ATRIUM DOOR (L),WHICH IS LISTED
 ON THE DOOR SCHEDULE AS WOOD AND GLASS,
 EXCEEDS THE MAXIMUM DESIGN PRESSURE OF
 THE PRODUCT APPROVAL FOR THE METAL AND
 GLASS DOOR THAT WAS SUBMITTED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2003-10-31 Cont ID  
Sent By dpalmer Date 2003-10-31 Time 12:36 Rev Time 0.33
Received By dpalmer Date 2003-10-31 Time 12:36 Sent To  
Notes
2003-10-31 00:00:00REV FOR FAN SYMBOL

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-09-30 Cont ID  
Sent By dpalmer Date 2003-09-30 Time 10:01 Rev Time 0.33
Received By dpalmer Date 2003-09-30 Time 10:01 Sent To  
Notes
2003-09-30 00:00:00REV FOR FLD LT.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2003-09-22 Cont ID  
Sent By csiegber Date 2003-09-24 Time 16:39 Rev Time 0.25
Received By dpalmer Date 2003-09-22 Time 20:31 Sent To  
Notes
2003-09-22 00:00:00***************** UNSAT *************
  
 1)NOTE: PLEASE SEE FS 471.025/ AND
 FAC 61G15-23.002.LETTERS MUST HAVE
 ORIGINAL SIGNATURE / DATE. NOT COPIES
 PLEASE ALSO INCLUDE CERTIFICATE OF
 AUTHORIZATION # ON TITLE BLOCK.
  
 2)NOTE: PLEASE ALSO SEE THAT LETTERS
 ARE MADE OUT TO THE PALM BEACH COUNTY
 PZB DEPT. PLEASE SEE THE THIS IS THE
 CITY OF WEST PALM BEACH, CONSTRUCTION
 SERVICES DEPT.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-09-16 Cont ID  
Sent By dpalmer Date 2003-09-16 Time 15:39 Rev Time 0.25
Received By dpalmer Date 2003-09-16 Time 15:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-06-24 Cont ID  
Sent By bstaples Date 2003-08-19 Time 09:11 Rev Time 0.60
Received By btrobaug Date 2003-06-24 Time 17:15 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-24 Cont ID  
Sent By csiegber Date 2003-09-24 Time 16:39 Rev Time 0.00
Received By csiegber Date 2003-09-24 Time 16:39 Sent To E
Notes
2003-09-24 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-19 Cont ID  
Sent By bstaples Date 2003-08-19 Time 09:10 Rev Time 0.00
Received By bstaples Date 2003-08-19 Time 09:10 Sent To E
Notes
2003-08-19 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-01 Cont ID  
Sent By alange Date 2003-08-01 Time 14:36 Rev Time 0.00
Received By alange Date 2003-08-01 Time 14:36 Sent To E
Notes
2003-08-01 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-11 Cont ID  
Sent By mmclean Date 2003-06-12 Time 10:29 Rev Time 0.00
Received By shernand Date 2003-06-11 Time 09:51 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-28 Cont ID  
Sent By jleech Date 2003-06-26 Time 17:49 Rev Time 0.25
Received By rregueir Date 2003-06-28 Time 13:27 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-08-11 Cont ID  
Sent By kstevens Date 2003-08-11 Time 11:23 Rev Time 0.50
Received By kstevens Date 2003-08-11 Time 11:23 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2003-06-26 Cont ID  
Sent By btrobaug Date 2003-06-24 Time 17:19 Rev Time 0.25
Received By jleech Date 2003-06-26 Time 17:49 Sent To M
Notes
2003-06-26 00:00:00NO PLUMBING PLANS.

Review Stop Z ZONING
Rev No 1 Status P Date 2003-06-12 Cont ID  
Sent By shernand Date 2003-06-11 Time 09:51 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***