Plan Review Stops For Permit 03060338 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2004-02-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-02-18 |
Time |
08:18 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2004-02-18 |
Time |
08:18 |
Sent To |
|
|
Notes |
2004-02-18 00:00:00 | REVISION DATED 2/9/04 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2004-01-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-09 |
Time |
11:20 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2004-01-17 |
Time |
12:41 |
Sent To |
|
|
Notes |
2004-01-17 00:00:00 | ****CORRECTIONS***** | | | | REVISION DATED 1/9/04 | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)ALL CHANGES/REVISIONS TO THE PLAN | | ARE TO OBTAIN HISTORIC APPROVAL. | | | | 2.)A CHANGE TO THE DESIGN CAN ONLY | | BE DONE BY THE DESIGNER OF RECORD, | | RIZA ALTAN. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-08-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-12 |
Time |
10:21 |
Rev Time |
0.50 |
Received By |
sthyng |
Date |
2003-08-19 |
Time |
16:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-07-12 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-19 |
Time |
15:19 |
Rev Time |
1.00 |
Received By |
sthyng |
Date |
2003-07-12 |
Time |
16:02 |
Sent To |
|
|
Notes |
2003-07-12 00:00:00 | *******CORRECTIONS****** | | | | 1.)FAC 61G15-23.002(2), A TITLE BLOCK | | (ENGINEER) ON EACH PAGE IS REQUIRED. | | | | 2.)HAVE THE ENGINEER INITIAL ALL | | CHANGES MADE IN INK TO THE PLAN. | | | | 3.)NO ATTACHMENTS WERE GIVEN FOR THE | | RAILING.SEE THE PREVIOUS CORRECTION | | LIST; GUARDRAIL TO COMPLY WITH FBC | | 1608.2.2.HAVE THE ENGINEER REVIEW AND | | SEAL THE GUARDRAIL DETAIL AND | | ATTACHMENTS, AND INDICATE ON THE PLAN | | THAT IT COMPLIES WITH FBC1608.2.2. | | | | 4.)THE DOOR PRODUCT APPROVAL SUBMITTED | | HAS A PRODUCT LIMITATION OF +50/-46 PSF. | | THE FRENCH DOOR ACCORDING TO YOUR PLAN | | MUST HAVE A MINIMUM OF +49/-57 PSF | | RATING.ANY NEW PRODUCT APPROVALS | | SUBMITTED MUST BE APPROVED BY THE | | HISTORIC PRESERVATION DIVISION. | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-06-23 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-11 |
Time |
15:22 |
Rev Time |
1.50 |
Received By |
sthyng |
Date |
2003-06-23 |
Time |
18:23 |
Sent To |
E |
|
Notes |
2003-06-23 00:00:00 | ******CORRECTIONS******* | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)HAVE EITHER AN ARCHITECT OR A | | STRUCTURAL ENGINEER REVIEW THE PLAN | | AND SEAL IT. | | | | 2.)IMPORTANCE FACTOR ON THE PLAN IS | | NOT CORRECT. | | | | 3.)PROVIDE DESIGN PRESSURE FOR THE | | FRENCH DOOR. | | | | 4.)THE PLANS INDICATE THAT THE | | CONTRACTOR IS TO PROVIDE INFORMATION ON | | THE RAILING.NONE WAS PROVIDED; PLEASE | | SUBMIT A DETAIL OF THE RAILING, GIVING | | ALL DIMENSIONS.GUARDRAIL TO COMPLY | | WITH FBC 1608.2.2. | | | | 5.)ATTACHMENTS NOT SPECIFIED ON THE | | NEW BALCONY FRAMING DETAIL; SAYS | | "W/USP".USP IS A BRAND NAME, NOT AN | | ATTACHMENT. | | | | 6.)PROVIDE A CONTRACT FOR THIS JOB. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-06-24 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-06-24 |
Time |
13:01 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2003-06-24 |
Time |
12:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2004-02-09 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-09 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-09 |
Time |
11:20 |
Sent To |
B |
|
Notes |
2004-02-09 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2004-01-12 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-12 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-12 |
Time |
10:21 |
Sent To |
B |
|
Notes |
2004-01-12 00:00:00 | TO SH DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-08-19 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-19 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-19 |
Time |
15:19 |
Sent To |
B |
|
Notes |
2003-08-19 00:00:00 | TO ST DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-07-11 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-11 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-11 |
Time |
15:22 |
Sent To |
B |
|
Notes |
2003-07-11 00:00:00 | STHYNG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-06-13 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-13 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-13 |
Time |
08:35 |
Sent To |
B |
|
Notes |
2003-06-13 00:00:00 | MISC BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-06-05 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-06-11 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-05 |
Time |
11:12 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-06-11 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-05 |
Time |
11:12 |
Rev Time |
1.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|