Plan Review Stops For Permit 03060296 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-07-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2003-07-24 |
Time |
12:18 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2003-07-24 |
Time |
12:18 |
Sent To |
PC |
|
Notes |
2003-07-24 00:00:00 | TRUSS ANCHOR SCHEDULE REVISION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-07-15 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-17 |
Time |
15:18 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2003-07-15 |
Time |
08:47 |
Sent To |
PC |
|
Notes |
2003-07-15 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-UPDATE/REVISE TRUSS ANCHOR SCHEDULE | | AND ALL DETAILS THAT ARE AFFECTED BY | | SECTION 1609.4.3 FBC 2001, WHICH DOES | | NOT ALLOW THE STEEL STRESS TO BE | | INCREASED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-07-09 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-11 |
Time |
11:41 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2003-07-09 |
Time |
14:49 |
Sent To |
PC |
|
Notes |
2003-07-09 00:00:00 | CHECKLIST: | | 1-PROVIDE STORM SHUTTERS INFORMATION OR | | APPLY FOR A SEPARATE PERMIT. | | 2-UPDATE TRUSS ANCHOR SCHEDULE AND ALL | | DETAILS THAT ARE AFFECTED BY SECTION | | 1609.4.3 FBC 2001, WHICH DOES NOT | | ALLOW THE ALLOWABLE STEEL STRESS | | TO BE INCREASED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-11-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-11-06 |
Time |
10:14 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2003-11-06 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-06-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-24 |
Time |
09:24 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-06-20 |
Time |
06:13 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-24 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-24 |
Time |
09:24 |
Sent To |
E |
|
Notes |
2003-10-24 00:00:00 | TO BT DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-07-17 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-17 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-17 |
Time |
15:18 |
Sent To |
B |
|
Notes |
2003-07-17 00:00:00 | JGOMEZ DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-07-11 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-11 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-11 |
Time |
11:41 |
Sent To |
B |
|
Notes |
2003-07-11 00:00:00 | JGOMEZ DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-06-05 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-06-11 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-05 |
Time |
11:46 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-06-30 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-06-30 |
Time |
07:29 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-06-30 |
Time |
07:29 |
Sent To |
P |
|
Notes |
2003-06-30 00:00:00 | MECHANICAL PERMIT 03060299 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-07-02 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-06-30 |
Time |
07:29 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2003-07-02 |
Time |
19:27 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-06-11 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-05 |
Time |
11:46 |
Rev Time |
1.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|