Plan Review Details - Permit 03060249
Plan Review Stops For Permit 03060249
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-06-23 Cont ID  
Sent By jwitmer Date 2003-06-23 Time 07:15 Rev Time 0.85
Received By jwitmer Date 2003-06-23 Time 07:15 Sent To  
Notes
2003-06-23 00:00:00MASTER PLAN 02081374 MODEL "E"
 1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
  
 RE-EVALUATE TRUSS ANCHOR SCHEDULE BEFORE
 FOOR FRAMING INSPECTION.
 JIM WITMER
 (561)805-6715

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-16 Cont ID  
Sent By shernand Date 2003-06-18 Time 13:31 Rev Time 0.50
Received By jwitmer Date 2003-06-16 Time 06:56 Sent To  
Notes
2003-06-16 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03060249
 ADD: 6651 DUVAL AVE
 CONT: HOME DYNAMICS
 TEL: (561)242-5105
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTIOIN: DENIED
  
 1) CHANGE TO MASTER "WHITE OUT"
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)659-8096 X 8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2003-06-23 Cont ID  
Sent By jwitmer Date 2003-06-23 Time 07:14 Rev Time 0.00
Received By jwitmer Date 2003-06-23 Time 07:13 Sent To  
Notes
2003-06-23 00:00:00MASTER PLAN 02081374

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-18 Cont ID  
Sent By shernand Date 2003-06-18 Time 13:31 Rev Time 0.00
Received By shernand Date 2003-06-18 Time 13:31 Sent To B
Notes
2003-06-18 00:00:00JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-05 Cont ID  
Sent By shernand Date 2003-06-05 Time 15:10 Rev Time 0.00
Received By shernand Date 2003-06-05 Time 15:10 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-06-23 Cont ID  
Sent By jwitmer Date 2003-06-23 Time 07:14 Rev Time 0.00
Received By jwitmer Date 2003-06-23 Time 07:13 Sent To  
Notes
2003-06-23 00:00:00MASTER PLAN 02081374
 MASTER PLAN 03061374

Review Stop P PLUMBING
Rev No 1 Status N Date 2003-06-23 Cont ID  
Sent By jwitmer Date 2003-06-23 Time 07:13 Rev Time 0.00
Received By jwitmer Date 2003-06-23 Time 07:13 Sent To  
Notes
2003-06-23 00:00:00MASTER PERMIT 03060249 MODEL E

Review Stop Z ZONING
Rev No 1 Status P Date 2003-06-11 Cont ID  
Sent By shernand Date 2003-06-05 Time 15:10 Rev Time 1.00
Received By mmclean Date   Time   Sent To B
Notes
2003-06-11 00:00:006/11/03 GIVEN TO JIM WITMER MM