Plan Review Stops For Permit 03051869 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-07-07 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-06-23 |
Time |
07:13 |
Rev Time |
1.25 |
Received By |
jwitmer |
Date |
2003-07-07 |
Time |
08:42 |
Sent To |
|
|
Notes |
2003-07-07 00:00:00 | | | *** ISSUED PERMIT*** | | -PLAN REVIEW HISTORY- | | | | PERMIT# 03051869 | | ADDRESS: 2355 MORGANS BLUFF | | CONT: SIERRA CONSTRUCTION | | TELL # (786)236-5362 | | | | THE ATTACHED COMMENTS ARE PART OF THE | | PERMIT AND PLAN REVIEW PACKAGE AND ARE | | NOT TO BE REMOVED FROM THE ISSUED SET OF | | PLANS.104.2.1.2 ADMINISTRATIVE CODE. | | | | *****PROVISO****** | | | | 1)R-3 EGRESS DOOR/ 32" CLEAR: | | 1003.2.1. THE WIDTH OF THE MEANS OF | | EGRESS SHALL BE DETERMINED FROM THE | | OCCUPANTS SERVED IN ACCORDANCE WITH | | TABLE 1004.R-3 MINIMUM CLEAR OPENING OF | | EXIT DOOR IS 32". 1012.1.1 EGRESS DOORS | | USED IN THE EXIT ACCESS SHALL PROVIDE A | | CLEAR OPENING OF NOT LESS THAN 32" WIDE. | | 1012.1.7 REQUIRED EXIT DOORS SHALL BE | | OPENABLE FROM THE INSIDE WITHOUT THE USE | | OF A KEY OR TOOL, OR SPECIAL KNOWEDGE OR | | EFFORT. MANUALLY OPERATED FLUSH BOLTS OR | | SURFACE BOLTS ARE PROHIBITED. ALL HARD- | | WARE MUST BE DIRECT ACTING REQUIRING NO | | MORE THAN ONE OPERATION. | | | | REVIEW FRONT ENTRY, REVISE BEFORE BUCK | | INSPECTION. | | | | 2) STORM SHUTTERS: | | A) MISSING KEY PLAN | | B) BOTTOM FASTENER, CAULK-IN, THE VALUE | | TAKEN FOR CONCRETE, NOT CEMENT BLOCK, | | OR IF THIS VALUE IS TO BE TAKEN FOR | | FILLED CELL THE CAULK-IN MUST BE SET IN | | 2500 PSI CONCRETE. OTHER ALTERNATIVE IS | | A DIFFERENT FASTENER FOR BLOCK. | | BUILDING PLAN REVIEW | | JIM WITMER | | (561) 805-6715 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2003-10-31 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-10-31 |
Time |
08:38 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-10-31 |
Time |
08:38 |
Sent To |
|
|
Notes |
2003-10-31 00:00:00 | REV FOR FAN SYMBOL. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2003-09-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-09-30 |
Time |
10:19 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-09-30 |
Time |
10:13 |
Sent To |
|
|
Notes |
2003-09-30 00:00:00 | ELEC REV FOR FLD LT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2003-09-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-24 |
Time |
16:40 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-09-22 |
Time |
20:13 |
Sent To |
|
|
Notes |
2003-09-22 00:00:00 | ************ UNSAT *********** | | | | 1)NOTE: PLEASE SEE FS 471.025 AND FAC | | 61G15-23.002 LETTERS TO BE ORIGINAL | | SIGNATURE/DATE. | | | | 2)NOTE: PLEASE ALSO SEE THE LETTERS ARE | | MADE OUT TO PALM BEACH COUNTY PZB. | | WE ARE CITY OF WEST PALM BEACH CONSTRUCT | | -ION SERVICE DEPT. | | ALSO, WRONG ADDRESS. | | | | 3)NOTE: PLEASE SEE FAC 61G15-23.002, | | CERTIFICATE OF AUTHORIZATION # REQ'D ON | | TITLE BLOCKS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-09-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-09-16 |
Time |
15:51 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-09-16 |
Time |
15:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-06-10 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2003-08-19 |
Time |
09:13 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-06-10 |
Time |
12:31 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-09-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-24 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-24 |
Time |
16:40 |
Sent To |
E |
|
Notes |
2003-09-24 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-08-19 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2003-08-19 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
bstaples |
Date |
2003-08-19 |
Time |
09:13 |
Sent To |
E |
|
Notes |
2003-08-19 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-05-27 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-27 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-27 |
Time |
08:55 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-06-23 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-06-23 |
Time |
06:50 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-06-23 |
Time |
06:50 |
Sent To |
P |
|
Notes |
2003-06-23 00:00:00 | MECHANICAL PERMIT 03051871 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-06-23 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-06-23 |
Time |
06:53 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2003-06-23 |
Time |
07:12 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-05-27 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-27 |
Time |
08:55 |
Rev Time |
1.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
E |
|
Notes |
|
|