Plan Review Details - Permit 03051863
Plan Review Stops For Permit 03051863
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-09-16 Cont ID  
Sent By sthyng Date 2003-09-16 Time 16:24 Rev Time 0.50
Received By sthyng Date 2003-09-16 Time 16:24 Sent To  
Notes
2003-09-16 00:00:00SUBMITTAL; INT PRESSURE COEFFICIENT,
 REVISED DOOR & WINDOW PRESSURE SCHEDULE

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-07-02 Cont ID  
Sent By jwitmer Date 2003-07-02 Time 13:09 Rev Time 3.50
Received By jwitmer Date   Time   Sent To  
Notes
2003-07-02 00:00:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 03051863
 ADDRESS: 2302 CURLEY CUT
 CONT: SIERRA CONST
 TELL # (786)236-5312
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 *******PROVISO********
  
 R-3 EGRESS DOOR/ 32" CLEAR:
 1003.2.1. THE WIDTH OF THE MEANS OF
 EGRESS SHALL BE DETERMINED FROM THE
 OCCUPANTS SERVED IN ACCORDANCE WITH
 TABLE 1004.R-3 MINIMUM CLEAR OPENING OF
 EXIT DOOR IS 32". 1012.1.1 EGRESS DOORS
 USED IN THE EXIT ACCESS SHALL PROVIDE A
 CLEAR OPENING OF NOT LESS THAN 32" WIDE.
 1012.1.7 REQUIRED EXIT DOORS SHALL BE
 OPENABLE FROM THE INSIDE WITHOUT THE USE
 OF A KEY OR TOOL, OR SPECIAL KNOWEDGE OR
 EFFORT. MANUALLY OPERATED FLUSH BOLTS OR
 SURFACE BOLTS ARE PROHIBITED. ALL HARD-
 WARE MUST BE DIRECT ACTING REQUIRING NO
 MORE THAN ONE OPERATION.
  
 REVIEW FRONT ENTRY REVISE BEFORE BUCK
 INSPECTION.
  
 2) STORM SHUTTERS :
 A) MISSING KEY PLAN THAT TIES TO THE
 INSTALLATION SCHEDULE.
 B) BOTTOM FASTENER CAULK-IN, THE VALUE
 TAKEN IS FOR CONCRETE, NOT CEMENT BLOCK!
 THIS FASTENER MAY NOT BE USED IN BLOCK,
 OR IF THIS IS USED IN FILLED CELL, THE
 CAULK-IN MUST BE IN 2500 PSI CONCRETE
 (FILED CELL).OTHER ALLTERNATIVE IS A
 DIFFERENT FASTENER FOR BLOCK!
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)805-6715

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-10-31 Cont ID  
Sent By dpalmer Date 2003-10-31 Time 12:55 Rev Time 0.33
Received By dpalmer Date 2003-10-31 Time 12:55 Sent To  
Notes
2003-10-31 00:00:00REV FOR FAN SYMBOL

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-09-17 Cont ID  
Sent By dpalmer Date 2003-09-17 Time 07:45 Rev Time 0.25
Received By dpalmer Date 2003-09-17 Time 07:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-06-10 Cont ID  
Sent By bstaples Date 2003-08-19 Time 09:03 Rev Time 0.50
Received By btrobaug Date 2003-06-10 Time 12:30 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-19 Cont ID  
Sent By bstaples Date 2003-08-19 Time 09:03 Rev Time 0.00
Received By bstaples Date 2003-08-19 Time 09:03 Sent To E
Notes
2003-08-19 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-27 Time 08:53 Rev Time 0.00
Received By shernand Date 2003-05-27 Time 08:53 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-07-02 Cont ID  
Sent By jleech Date 2003-06-21 Time 09:05 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2003-07-02 00:00:006/21/03 OK PER PH KRAUSS

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-07-12 Cont ID  
Sent By kstevens Date 2003-07-12 Time 10:37 Rev Time 0.33
Received By kstevens Date 2003-07-12 Time 10:37 Sent To  
Notes
2003-07-12 00:00:00REVISION OK - ADDED SINK IN GARAGE -
 CHANGED PIPE SIZE FOR BLDG DRAIN TO 4"

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-06-21 Cont ID  
Sent By btrobaug Date 2003-06-10 Time 12:38 Rev Time 0.25
Received By jleech Date 2003-06-21 Time 09:05 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-27 Time 08:53 Rev Time 1.00
Received By mmclean Date   Time   Sent To E
Notes
***NONE***