Plan Review Details - Permit 03051857
Plan Review Stops For Permit 03051857
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-09-17 Cont ID  
Sent By sthyng Date 2003-09-17 Time 15:50 Rev Time 0.50
Received By sthyng Date 2003-09-17 Time 15:50 Sent To  
Notes
2003-09-17 00:00:00REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-01 Cont ID  
Sent By jwitmer Date 2003-07-01 Time 08:47 Rev Time 1.00
Received By jwitmer Date 2003-07-01 Time 08:47 Sent To  
Notes
2003-07-01 00:00:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 03051857
 ADDRESS: 8719 S SAN ANDROS
 CONT: SIERRA CONT
 TELL # (786)236-5312
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 ******PROVIDO*****
 1)PROVIDE NEW PRODUCT APPROVAL AND
 REVISE PLANS FOR THE FRONT ENTRY DOOR
 BEFORE BUCK INSPECTION, TO COMPLY WITH:
 R-3 EGRESS DOOR/ 32" CLEAR:
 1003.2.1. THE WIDTH OF THE MEANS OF
 EGRESS SHALL BE DETERMINED FROM THE
 OCCUPANTS SERVED IN ACCORDANCE WITH
 TABLE 1004.R-3 MINIMUM CLEAR OPENING OF
 EXIT DOOR IS 32". 1012.1.1 EGRESS DOORS
 USED IN THE EXIT ACCESS SHALL PROVIDE A
 CLEAR OPENING OF NOT LESS THAN 32" WIDE.
 1012.1.7 REQUIRED EXIT DOORS SHALL BE
 OPENABLE FROM THE INSIDE WITHOUT THE USE
 OF A KEY OR TOOL, OR SPECIAL KNOWEDGE OR
 EFFORT. MANUALLY OPERATED FLUSH BOLTS OR
 SURFACE BOLTS ARE PROHIBITED. ALL HARD-
 WARE MUST BE DIRECT ACTING REQUIRING NO
 MORE THAN ONE OPERATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-20 Cont ID  
Sent By hmoser Date 2003-06-19 Time 19:59 Rev Time 1.25
Received By jwitmer Date 2003-06-20 Time 08:17 Sent To  
Notes
2003-06-20 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03051857
 ADD: 03051857
 CONT: SEIRRA
 TEL: (786)236-5312
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 THE TEST REPORT SUBMITTED IS FOR ANDROS
 ISLES PARCEL "E2" PLAT 1. THE PARCEL IN
 QUESTION IS "E2" PLAT 2.THE REPORT READS
 FOR PLAT 1, PLAT 2 IS NOT INCLUDED.
  
 3) TABLE 600 ISSUE, PROVIDE 1 HR RATING
 MANUFACTURES SPEC CONSIDERED WALL NOT
 OPENING SINCE 0-3' NO OPENINGS ALLOWED.
  
 4) PLANS INDICATE THE USE OF STORM
 SHUTTERS FOR WINDOWS AND SIDELITES,
 NO KEY PLAN NOR STORM SHUTTER SCHEDULE
 WAS PROVIDED INDICATING WHICH WINDOWS
 LARGE MISSLE PROTECTED OR SHUTTERED,
 THE STORM SHUTTER INFORMATION PROVIDED
 INDICATES THE USE OF 1/4" CALK-INS IN
 MASONARY, USING THE C-1 CONNECTION, THE
 PRODUCT TESTING REPORT DOES NOT ALLOW
 FOR IT.
  
 5) 1606.1.7 REQUIRED WIND DESIGN INFORMA
 TION, MISSING THE INTERNAL PRESSURE
 COEFFICIENT. WITHOUT THIS IT IS ONLY ASS
 UMED THAT THIS IS A CLOSED BUILDING.
 CLOSED BUILDING+-.18
 PARTIAL ENCLOSED+-.55
 OPEN+-.0
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-10-31 Cont ID  
Sent By dpalmer Date 2003-10-31 Time 09:24 Rev Time 0.33
Received By dpalmer Date 2003-10-31 Time 09:24 Sent To  
Notes
2003-10-31 00:00:00REV FOR FAN SYMBOL.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-09-16 Cont ID  
Sent By dpalmer Date 2003-09-16 Time 13:48 Rev Time 0.25
Received By dpalmer Date 2003-09-16 Time 13:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-06-05 Cont ID  
Sent By bstaples Date 2003-08-19 Time 08:53 Rev Time 0.50
Received By btrobaug Date 2003-06-05 Time 08:14 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-19 Cont ID  
Sent By bstaples Date 2003-08-19 Time 08:53 Rev Time 0.00
Received By bstaples Date 2003-08-19 Time 08:53 Sent To E
Notes
2003-08-19 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-02 Cont ID  
Sent By shernand Date 2003-06-02 Time 13:38 Rev Time 0.00
Received By shernand Date 2003-06-02 Time 13:38 Sent To E
Notes
2003-06-02 00:00:00NEEDS ELECTRICAL REVIEW, DP ON VACATION.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-27 Time 08:53 Rev Time 0.00
Received By shernand Date 2003-05-27 Time 08:53 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-19 Cont ID  
Sent By jleech Date 2003-06-17 Time 20:19 Rev Time 0.25
Received By hmoser Date 2003-06-19 Time 19:59 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-06-17 Cont ID  
Sent By btrobaug Date 2003-06-05 Time 08:31 Rev Time 0.25
Received By jleech Date 2003-06-17 Time 20:18 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-27 Time 08:54 Rev Time 1.00
Received By mmclean Date   Time   Sent To E
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved