Plan Review Details - Permit 03051851
Plan Review Stops For Permit 03051851
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-09-16 Cont ID  
Sent By sthyng Date 2003-09-16 Time 17:48 Rev Time 0.50
Received By sthyng Date 2003-09-16 Time 17:48 Sent To  
Notes
2003-09-16 00:00:00REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-09 Cont ID  
Sent By jwitmer Date 2003-07-09 Time 06:56 Rev Time 1.50
Received By jwitmer Date 2003-07-09 Time 06:54 Sent To  
Notes
2003-07-09 00:00:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 03051851
 ADDRESS: 8853 S. SAN ANDROS
 CONT: SIERRA
 TELL # (786)236-5312
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
 *****PROVISO******
 1) ZERO LOT SIDE OF PROPERTY REQUIRES A
 EGRESS ACCESS EASEMENT BEFORE C/O.
  
 2) PROVIDE NEW PRODUCT APPROVAL AND
 REVISE PLANS FOR THE FRONT ENTRY DOOR
 BEFORE BUCK INSPECTION, TO COMPLY WITH:
 R-3 EGRESS DOOR/ 32" CLEAR:
 1003.2.1. THE WIDTH OF THE MEANS OF
 EGRESS SHALL BE DETERMINED FROM THE
 OCCUPANTS SERVED IN ACCORDANCE WITH
 TABLE 1004.R-3 MINIMUM CLEAR OPENING OF
 EXIT DOOR IS 32". 1012.1.1 EGRESS DOORS
 USED IN THE EXIT ACCESS SHALL PROVIDE A
 CLEAR OPENING OF NOT LESS THAN 32" WIDE.
 1012.1.7 REQUIRED EXIT DOORS SHALL BE
 OPENABLE FROM THE INSIDE WITHOUT THE USE
 OF A KEY OR TOOL, OR SPECIAL KNOWEDGE OR
 EFFORT. MANUALLY OPERATED FLUSH BOLTS OR
 SURFACE BOLTS ARE PROHIBITED. ALL HARD-
 WARE MUST BE DIRECT ACTING REQUIRING NO
 MORE THAN ONE OPERATION.
  
 3) A) KEY PLAN FOR SHUTTER OPENINGS.
 B) BOTTOM FASTENER CAULK-IN, THE VALUE
 TAKEN IS FOR CONCRETE, NOT CEMENT BLOCK!
 THIS FASTENER MAY NOT BE USED IN BLOCK,
 OR IF THIS IS USED IN FILLED CELL, THE
 CAULK-IN MUST BE IN 2500 PSI CONCRETE
 (FILLED CELL). OTHER ALTERNATIVE IS A
 DIFFERENT FASTENER FOR BLOCK.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-19 Cont ID  
Sent By hmoser Date 2003-06-18 Time 18:42 Rev Time 1.50
Received By jwitmer Date 2003-06-19 Time 17:37 Sent To  
Notes
2003-06-19 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03051851
 ADD: 8853 S. SAN ANDROS
 CONT: SIERRA CONST
 TEL: (561)616-9686
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 THE TESING REPORT IS FOR ANDROS ISLES
 PARCEL "E2" PLAT1.THE PARCEL IN QUESTION
 IS "E2" PLAT2.
  
 3) TABLE 600 ISSUE, GLASS BLOCK, PROVIDE
 DOCUMENTATION FOR 1 HR RATING, 0-3' FROM
 THE PROPERTY LINE. THIS IS NOT CONSIDER-
 ED OPENING BUT WALL 1HR RATING.
  
 4) PLANS INDICATE THEUSE OF STORM
 SHUTTRS FOR WINDOWS AND SIDELITES BUT
 NO STORM SHUTTER INFORMATION ATTACHED.
 MISSING PRODUCT APPROVAL, KEY PLAN
 AND INSTALLATION SCHEDULE, SEE ATTACH-
 MENT FOR SAMPLE.
  
 4) 1606.1.7 REQUIRED WIND DESIGN
 INFORMATION, MISSING THE INTERNAL
 PRESSURE COEFFICIENT. WITHOUT THIS IT
 IS ONLY ASSUMED THAT IT IS A CLOSED
 BUILDING.
 CLOSED BUILDING+-.18
 PARTIAL ENCLOSED +-.55
 OPEN +-.0
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-10-31 Cont ID  
Sent By dpalmer Date 2003-10-31 Time 11:03 Rev Time 0.33
Received By dpalmer Date 2003-10-31 Time 09:55 Sent To  
Notes
2003-10-31 00:00:00REV FOR FAN SYMBOL

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-09-16 Cont ID  
Sent By dpalmer Date 2003-09-16 Time 16:07 Rev Time 0.25
Received By dpalmer Date 2003-09-16 Time 16:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-06-03 Cont ID  
Sent By bstaples Date 2003-08-19 Time 09:16 Rev Time 0.50
Received By btrobaug Date 2003-06-03 Time 13:49 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-19 Cont ID  
Sent By bstaples Date 2003-08-19 Time 09:16 Rev Time 0.00
Received By bstaples Date 2003-08-19 Time 09:15 Sent To E
Notes
2003-08-19 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-27 Time 08:56 Rev Time 0.00
Received By shernand Date 2003-05-27 Time 08:56 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-18 Cont ID  
Sent By jleech Date 2003-06-17 Time 18:34 Rev Time 0.50
Received By hmoser Date 2003-06-18 Time 18:42 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-06-17 Cont ID  
Sent By btrobaug Date 2003-06-03 Time 13:56 Rev Time 0.25
Received By jleech Date 2003-06-17 Time 18:34 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-27 Time 08:56 Rev Time 1.00
Received By mmclean Date   Time   Sent To E
Notes
***NONE***