Plan Review Details - Permit 03051829
Plan Review Stops For Permit 03051829
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-09-17 Cont ID  
Sent By sthyng Date 2003-09-17 Time 15:17 Rev Time 0.50
Received By sthyng Date 2003-09-17 Time 15:17 Sent To  
Notes
2003-09-17 00:00:00REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-03 Cont ID  
Sent By jwitmer Date 2003-07-03 Time 07:01 Rev Time 0.99
Received By jwitmer Date 2003-07-03 Time 07:01 Sent To  
Notes
2003-07-03 00:00:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 03051863
 ADDRESS: 2302 CURLEY CUT
 CONT: SIERRA CONST
 TELL # (786)236-5312
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 ******PROVISO******
  
 1)R-3 EGRESS DOOR/ 32" CLEAR:
 1003.2.1. THE WIDTH OF THE MEANS OF
 EGRESS SHALL BE DETERMINED FROM THE
 OCCUPANTS SERVED IN ACCORDANCE WITH
 TABLE 1004.R-3 MINIMUM CLEAR OPENING OF
 EXIT DOOR IS 32". 1012.1.1 EGRESS DOORS
 USED IN THE EXIT ACCESS SHALL PROVIDE A
 CLEAR OPENING OF NOT LESS THAN 32" WIDE.
 1012.1.7 REQUIRED EXIT DOORS SHALL BE
 OPENABLE FROM THE INSIDE WITHOUT THE USE
 OF A KEY OR TOOL, OR SPECIAL KNOWEDGE OR
 EFFORT. MANUALLY OPERATED FLUSH BOLTS OR
 SURFACE BOLTS ARE PROHIBITED. ALL HARD-
 WARE MUST BE DIRECT ACTING REQUIRING NO
 MORE THAN ONE OPERATION.
  
 REVIEW FRONT ENTRY,REVISE BEFORE
 BUCK INSPECTION.
  
 2) STORM SHUTTERS:
 A) MISSING KEY PLAN
 B) BOTTOM FASTENER CAULK-IN, THE VALUE
 TAKEN IS FOR CONCRETE, NOT CEMENT BLOCK!
 THIS FASTENER MAY NOT BE USED IN BLOCK!
 IF USED IN FILLED CELL, THE CAULK-IN
 MUST BE IN 2500 PSI CONCRETE (FILLED
 CELL). OTHERWISE ALLTERNATIVE IS A
 DIFFERENT FASTENER.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)805-6715

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-20 Cont ID  
Sent By hmoser Date 2003-06-19 Time 19:30 Rev Time 0.55
Received By jwitmer Date   Time   Sent To  
Notes
2003-06-20 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03051829
 ADD: 8771 S SAN ANDROS
 CONT: SIERRA
 TEL: (561)6616-9686
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
 SAME COMMENTS AS 03051835

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-10-31 Cont ID  
Sent By dpalmer Date 2003-10-31 Time 13:29 Rev Time 0.33
Received By dpalmer Date 2003-10-31 Time 13:29 Sent To  
Notes
2003-10-31 00:00:00REV FOR FAN SYMBOL

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-09-17 Cont ID  
Sent By dpalmer Date 2003-09-17 Time 06:54 Rev Time 0.25
Received By dpalmer Date 2003-09-17 Time 06:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-06-09 Cont ID  
Sent By bstaples Date 2003-08-19 Time 09:01 Rev Time 0.50
Received By btrobaug Date 2003-06-09 Time 11:41 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-19 Cont ID  
Sent By bstaples Date 2003-08-19 Time 09:01 Rev Time 0.00
Received By bstaples Date 2003-08-19 Time 09:01 Sent To E
Notes
2003-08-19 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-23 Cont ID  
Sent By shernand Date 2003-05-23 Time 16:47 Rev Time 0.00
Received By shernand Date 2003-05-23 Time 16:47 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-19 Cont ID  
Sent By jleech Date 2003-06-17 Time 20:19 Rev Time 0.25
Received By hmoser Date 2003-06-19 Time 19:29 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-06-17 Cont ID  
Sent By btrobaug Date 2003-06-09 Time 11:41 Rev Time 0.25
Received By jleech Date 2003-06-17 Time 20:19 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-23 Time 16:47 Rev Time 1.00
Received By mmclean Date   Time   Sent To E
Notes
***NONE***