Plan Review Details - Permit 03051808
Plan Review Stops For Permit 03051808
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-11-03 Cont ID  
Sent By sthyng Date 2003-11-03 Time 15:16 Rev Time 0.50
Received By sthyng Date 2003-11-03 Time 15:16 Sent To  
Notes
2003-11-03 00:00:00ELEC/PLUMB REVISION (A3&A6)

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status N Date 2003-07-16 Cont ID  
Sent By kstevens Date 2003-10-30 Time 17:26 Rev Time 0.50
Received By sthyng Date 2003-07-14 Time 12:41 Sent To  
Notes
2003-07-14 00:00:007/14/03
 IMPACT FEES PAID ON WRONG SQUARE FOOTAGE
  
  
 IMPACT FEES CORRECTED, 7/16/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-07-07 Cont ID  
Sent By shernand Date 2003-07-11 Time 16:43 Rev Time 3.00
Received By lhatten Date 2003-07-06 Time 18:04 Sent To  
Notes
2003-07-07 00:00:00REVIEW & STAMPED PLANS 07/06/2003

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-10-27 Cont ID  
Sent By btrobaug Date 2003-10-27 Time 17:18 Rev Time 0.50
Received By btrobaug Date 2003-10-27 Time 17:06 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-09-05 Cont ID  
Sent By csiegber Date 2003-10-24 Time 12:38 Rev Time 0.50
Received By btrobaug Date 2003-09-05 Time 12:19 Sent To P
Notes
2003-09-05 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE NOTE THAT THE RISER DIAGRAM
 SHOWS THE PANEL BEING FED DIRECTLY FROM
 THE METER AND THE PLAN INDICATES A
 METER MAIN ,PLEASE CORRELATE.
  
 PLEASE CORRECT THE ARCHITECTS TITLE
 BLOCK YO CONFORM WITH FAC. 61G1-16.004.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-06-05 Cont ID  
Sent By csiegber Date 2003-08-29 Time 15:49 Rev Time 0.50
Received By btrobaug Date 2003-06-05 Time 07:53 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-10-24 Cont ID  
Sent By csiegber Date 2003-10-24 Time 12:37 Rev Time 0.00
Received By csiegber Date 2003-10-24 Time 12:37 Sent To E
Notes
2003-10-24 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-29 Cont ID  
Sent By csiegber Date 2003-08-29 Time 15:49 Rev Time 0.00
Received By csiegber Date 2003-08-29 Time 15:49 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-11 Cont ID  
Sent By shernand Date 2003-07-11 Time 16:43 Rev Time 0.00
Received By shernand Date 2003-07-11 Time 16:43 Sent To B
Notes
2003-07-11 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-27 Time 09:04 Rev Time 0.00
Received By shernand Date 2003-05-27 Time 09:04 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-21 Cont ID  
Sent By jleech Date 2003-06-19 Time 19:11 Rev Time 0.50
Received By hmoser Date 2003-06-21 Time 06:41 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-10-30 Cont ID  
Sent By kstevens Date 2003-10-30 Time 17:26 Rev Time 0.50
Received By kstevens Date 2003-10-30 Time 17:26 Sent To B
Notes
2003-10-30 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-09-10 Cont ID  
Sent By btrobaug Date 2003-10-27 Time 17:18 Rev Time 0.50
Received By kstevens Date 2003-09-10 Time 16:20 Sent To  
Notes
2003-09-10 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 AMENDMENTS, CHAPT 1,
 FLORIDA ADMIN. CODE
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS, NOR DOES IT REFLECT
 THE FLOOR PLAN.
 A) SECTION 909.1 ONLY THE FIXTURES WITH
 IN THE BATHROOM GROUP SHALL CONNECT TO
 THE WET-VENTED HORIZONTAL BRANCH DRAIN.
 ANY ADDITIONAL FIXTURES SHALL DISCHARGE
 DOWNSTREAM OF THE WET VENT. THE W/M AND
 L/T SHALL CONNECT DOWNSTREAM OF BATHROOM
 FIXTURES.
 B) THE LAVS IN THE MASTER BATHROOM ARE
 ON DIFFERENT WALLS AND CANNOT DRAIN TO A
 COMMON STACK. 104.2.1
 C) MINIMUM TRAP SIZE FOR WASH MACHINE
 IS 2". TABLE 709.1
 2) ARCHITECT'S LICENSE NUMBER REQUIRED
 ON TITLE BLOCK. 61G1-16.004
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-06-19 Cont ID  
Sent By btrobaug Date 2003-09-05 Time 12:20 Rev Time 0.25
Received By jleech Date 2003-06-19 Time 19:11 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-27 Time 09:04 Rev Time 1.00
Received By mmclean Date   Time   Sent To E
Notes
***NONE***