Plan Review Details - Permit 03051780
Plan Review Stops For Permit 03051780
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-09-16 Cont ID  
Sent By sthyng Date 2003-09-16 Time 17:27 Rev Time 0.50
Received By sthyng Date 2003-09-16 Time 17:27 Sent To  
Notes
2003-09-16 00:00:00REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-07 Cont ID  
Sent By dbaxter Date 2003-08-28 Time 10:23 Rev Time 1.20
Received By jwitmer Date 2003-07-07 Time 10:32 Sent To  
Notes
2003-07-07 00:00:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 03051780
 ADDRESS: 2405 CURLEY CUT
 CONT: SIERRA CONSTRUCTION
 TELL # (786) 236-5312
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 ******PROVISO*******
  
 1) R-3 EGRESS DOOR/ 32" CLEAR:
 1003.2.1. THE WIDTH OF THE MEANS OF
 EGRESS SHALL BE DETERMINED FROM THE
 OCCUPANTS SERVED IN ACCORDANCE WITH
 TABLE 1004.R-3 MINIMUM CLEAR OPENING OF
 EXIT DOOR IS 32". 1012.1.1 EGRESS DOORS
 USED IN THE EXIT ACCESS SHALL PROVIDE A
 CLEAR OPENING OF NOT LESS THAN 32" WIDE.
 1012.1.7 REQUIRED EXIT DOORS SHALL BE
 OPENABLE FROM THE INSIDE WITHOUT THE USE
 OF A KEY OR TOOL, OR SPECIAL KNOWEDGE OR
 EFFORT. MANUALLY OPERATED FLUSH BOLTS OR
 SURFACE BOLTS ARE PROHIBITED. ALL HARD-
 WARE MUST BE DIRECT ACTING REQUIRING NO
 MORE THAN ONE OPERATION.
  
 2) STORM SHUTTERS:
 A) MISSING KEY PLAN
 B) BOTTOM FASTENER CAULK-IN, THE VALUE
 TAKEN IS FOR CONCRETE, NOT CEMENT BLOCK!
 THIS FASTENER MAY NOT BE USED IN BLOCK,
 OR IF THIS IS USED IN FILLED CELL, THE
 CAULK-IN MUST BE IN 2500 PSI CONCRETE
 (FILLED CELL). OTHER ALTERNATIVE IS A
 DIFFERENT FASTENER FOR BLOCK.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-20 Cont ID  
Sent By hmoser Date 2003-06-19 Time 18:53 Rev Time 0.55
Received By jwitmer Date 2003-06-20 Time 11:38 Sent To  
Notes
2003-06-20 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03051780
 ADD: 2405 CURLEY CUT
 CONT: SIERRA CONSTRUCTION
 TEL: (561)616-9686
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
 1) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 REPORT SUBMITTED IS FOR ANDROS ISLES
 PARCEL "E2" PLAT 1 NOT PLAT2.
  
 2) TABLE 600 ISSUE GLASS BLOCK, PROVIDE
 DOCUMENTATION FOR 1 HR. RATING, 0-3'
 FROM THE PROPERTY LINE ALLOWS FOR ZERO
 OPENINGS IN WALL SO DOCUMENTATION IS FOR
 1 HR NOT 3/4HR FOR OPENINGS.
  
 3) PLANS INDICATE THE USE OF STORM
 SHUTTERS FOR WINDOWS AND SIDELITES BUTNO
 FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.SEE SAMPLE SCHEDULE.
  
 4) 1606.1.7 REQUIRED WIND INFORMATION,
 MISSING THE INTERNAL PRESSURE COEFFI-
 CIENT. WITHOUT THIS IT IS ONLY ASSUMED ?
 CLOSED BUILDING+-.18
 PARTIAL +-.55
 OPEN +-.0
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2003-10-31 Cont ID  
Sent By dpalmer Date 2003-10-31 Time 08:37 Rev Time 0.33
Received By dpalmer Date 2003-10-31 Time 08:37 Sent To  
Notes
2003-10-31 00:00:00REV FOR FAN SYMBOL.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-09-30 Cont ID  
Sent By dpalmer Date 2003-09-30 Time 08:09 Rev Time 0.33
Received By dpalmer Date 2003-09-30 Time 08:07 Sent To  
Notes
2003-09-30 00:00:00REV FOR FLT LT.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2003-09-22 Cont ID  
Sent By csiegber Date 2003-09-24 Time 16:37 Rev Time 0.25
Received By dpalmer Date 2003-09-22 Time 20:19 Sent To  
Notes
2003-09-22 00:00:00***************** UNSAT **************
  
 1)NOTE: PLEASE SEE FS 471.025 AND FAC
 61G15-23.002. PLEASE SEE THAT LETTERS
 MUST HAVE ORIGINAL SIGNATURE/DATE.
 NOT COPIES. PLEASE ALSO INCLUDE THE
 CERTIFICATE OF AUTHORIZATION # ON TITLE
 BLOCK.
  
 2)NOTE: PLEASE ALSO SEE THE LETTERS ARE
 MADE OUT TO PALM BEACH COUNTY PZB, 100
 AUST AVE ETC.
 THIS IS UNDERTHE CITY OF WEST PALM
 BEACH, CONSTRUCTION SERVICES DEPT.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-09-17 Cont ID  
Sent By dpalmer Date 2003-09-17 Time 07:49 Rev Time 0.25
Received By dpalmer Date 2003-09-17 Time 07:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-06-05 Cont ID  
Sent By bstaples Date 2003-08-19 Time 09:12 Rev Time 0.50
Received By btrobaug Date 2003-06-05 Time 07:30 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-09-24 Cont ID  
Sent By csiegber Date 2003-09-24 Time 16:37 Rev Time 0.00
Received By csiegber Date 2003-09-24 Time 16:37 Sent To E
Notes
2003-09-24 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-08-28 Cont ID  
Sent By dbaxter Date 2003-08-28 Time 10:23 Rev Time 0.00
Received By dbaxter Date 2003-08-28 Time 10:23 Sent To B
Notes
2003-08-28 00:00:00TO JWITMER DESK.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-19 Cont ID  
Sent By bstaples Date 2003-08-19 Time 09:12 Rev Time 0.00
Received By bstaples Date 2003-08-19 Time 09:12 Sent To E
Notes
2003-08-19 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-02 Cont ID  
Sent By shernand Date 2003-06-02 Time 13:37 Rev Time 0.00
Received By shernand Date 2003-06-02 Time 13:37 Sent To E
Notes
2003-06-02 00:00:00NEEDS ELECTRICAL REVIEW, DP ON VACATION.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-23 Cont ID  
Sent By shernand Date 2003-05-23 Time 15:49 Rev Time 0.00
Received By shernand Date 2003-05-23 Time 15:49 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-19 Cont ID  
Sent By jleech Date 2003-06-19 Time 17:31 Rev Time 0.25
Received By hmoser Date 2003-06-19 Time 18:53 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-06-19 Cont ID  
Sent By btrobaug Date 2003-06-05 Time 07:52 Rev Time 0.25
Received By jleech Date 2003-06-19 Time 17:31 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-23 Time 15:49 Rev Time 1.00
Received By mmclean Date   Time   Sent To E
Notes
***NONE***