Plan Review Stops For Permit 03051635 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
N |
Date |
2003-08-26 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-08-26 |
Time |
13:11 |
Rev Time |
0.25 |
Received By |
sthyng |
Date |
2003-08-26 |
Time |
13:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-06-18 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-25 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-06-18 |
Time |
08:58 |
Sent To |
|
|
Notes |
2003-06-18 00:00:00 | ******PROVISO******** | | SUBMIT A REVISION FOR SHEET | | A4 USING 2003 CONNECTORS CATALOG | | FOR REVISED ANCHORS.INCLUDE | | DESIGN INFORMATION FBC1606.1.7. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-06-10 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-17 |
Time |
15:30 |
Rev Time |
2.00 |
Received By |
sthyng |
Date |
2003-06-10 |
Time |
17:45 |
Sent To |
|
|
Notes |
2003-06-10 00:00:00 | ******CORRECTIONS******* | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)SEPARATE PERMITS REQUIRED. | | | | 2.)ADDITIONAL FEES REQUIRED. | | | | 3.)WINDOW HEAD & SILL, WINDOW JAMB | | DETAILS; BUCK MUST COMPLY WITH FBC | | 1707.4.4.2.THE DETAILS ALSO CONFLICT | | WITH THE PRODUCT APPROVALS. | | | | 4.)FBC 3401.7.1, IN REGARDS TO | | ADDITIONS OF OVER 25%, SHOW BEDROOM | | EMERGENCY EGRESS AND SMOKE DETECTORS | | IN EXISTING BEDROOMS. | | | | 5.)ENERGY CALCS SPECIFY R5 INSULATION, | | WALL SECTION (A4) SHOWS R3. | | | | 6.)TRUSS ANCHORS UPLIFT EXCEED THE | | MAXIMUM UPLIFT SPECIFIED IN THE | | CATALOG.SEE USP 2003 CATALOG, AND ALSO | | READ PP 6-7 REGARDING STRESS INCREASES | | FOR STEEL. | | | | 7.)FIRESTOP REQUIRED, FBC 705.3. | | | | 8.)SHOW THE 4" ABOVE GRADE, 12" MIN. | | BELOW GRADE FOR THE FOOTER (WALL SECTION | | A4). | | | | 9.)SOFFIT VENTS REQUIRED, SPECIFY | | SIZE AND SPACING TO COMPLY WITH FBC | | 2309.7. | | | | 10.)1 1/2" WATERSTOP REQUIRED, CITY OF | | WEST PALM BEACH AMENDMENTS TO THE FBC, | | 2111.1.9. | | | | 11.)PROVIDE DESIGN INFORMATION ON THE | | PLAN FBC 1606.1.7. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-06-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-06-18 |
Time |
16:02 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2003-06-18 |
Time |
16:01 |
Sent To |
B |
|
Notes |
2003-06-18 00:00:00 | RESTAMPED./WRT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-05-27 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-27 |
Time |
08:46 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-05-27 |
Time |
16:41 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-12-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-16 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-16 |
Time |
10:36 |
Sent To |
M |
|
Notes |
2003-12-16 00:00:00 | TO PK BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-08-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-25 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-08-25 |
Time |
11:35 |
Sent To |
B |
|
Notes |
2003-08-25 00:00:00 | TO ST DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-06-17 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-17 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-17 |
Time |
15:30 |
Sent To |
B |
|
Notes |
2003-06-17 00:00:00 | STHYNG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-05-27 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-27 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-27 |
Time |
08:46 |
Sent To |
E |
|
Notes |
2003-05-27 00:00:00 | BT DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-05-21 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-05-27 |
Time |
07:51 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-21 |
Time |
14:14 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-12-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-12-18 |
Time |
10:20 |
Rev Time |
0.15 |
Received By |
pkrauss |
Date |
2003-12-18 |
Time |
09:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-05-30 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-16 |
Time |
10:36 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2003-05-30 |
Time |
10:15 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-05-29 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2001-05-29 |
Time |
06:44 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2003-05-29 |
Time |
15:27 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-05-27 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-21 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|