|
 |
 |
 |
 |
 |
Plan Review Details - Permit 03051112
Plan Review Stops For Permit 03051112 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-05-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-05-22 |
Time |
16:45 |
Rev Time |
0.75 |
Received By |
lsmith |
Date |
2003-05-23 |
Time |
11:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-05-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-05-22 |
Time |
09:10 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2003-05-22 |
Time |
16:33 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-05-27 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-27 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-27 |
Time |
16:22 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-05-14 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-14 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-14 |
Time |
10:51 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-05-31 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-05-31 |
Time |
08:58 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-05-31 |
Time |
08:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-05-22 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-27 |
Time |
16:22 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-05-22 |
Time |
09:07 |
Sent To |
E |
|
Notes |
2003-05-22 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | FORMATION REQUIRED FOR PLAN REVIEW | | 1) FBC-2001 424.2.14.1 SWIMMING POOL | | WATER HEATERS SHALL BEAR THE LABEL OF A | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | SHEETS REQUIRED. (SUBMITTAL) | | 2) FBC-2001 424.2.14.2 WATER RETENTION, | | PROVIDE A POSITIVE MEANS OF RETAINING | | WATER IN THE HEATER WHEN PUMP IS SHUT | | OFF. (MANUFACTURE CUT SHEETS SUBMITTAL) | | 3) FBC-2001 424.2.14.4 CONNECTIONS, ALL | | WATER HEATING EQUIPMENT SHALL BE INSTAL- | | LED WITH FLANGES OR UNION CONNECTIONS | | ADJACENT TO THE HEATER. (ADD TO NOTES) | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-05-20 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-14 |
Time |
10:51 |
Rev Time |
1.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |