Plan Review Details - Permit 03050683
Plan Review Stops For Permit 03050683
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-07 Cont ID  
Sent By lmartine Date 2003-07-07 Time 13:38 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-15 Cont ID  
Sent By shernand Date 2003-07-07 Time 12:38 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2003-05-15 00:00:00 
 BUILDING COMMENTS
 -------- --------
  
 1]
 RAMP REQUIRES 28' OF HORIZONTAL
 PROJECTION WITH A RISE OF 28" IN ORDER
 TO COMPLY WITH THE 1/12 PITCH
 REQUIREMENT. FBC 11-4.8.2.
  
 2]
 FBC 11-4.8.3[EXCEPTION] REQUIRES MIN.
 44" CLEAR WIDTH, PLAN CALLS FOR 36".
  
 3]
 FBC 11-4.8.5[3] REQUIRES A CLEAR WIDTH
 SEPERATION OF 1.5" BETWEEN HANDRAIL AND
 THE WALL.
  
 4]
 PROVIDE EDGE PROTECTION AS PER FBC
 11-4.8.7
  
 5]
 LANDING AT BOTTOM OF RAMP SHALL BE
 LOCATED WITHIN THE PROPERTY BOUNDARIES.
  
  
  
  
 L.MARTINEZ
 805-6710

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-17 Cont ID  
Sent By shernand Date 2003-07-17 Time 12:59 Rev Time 0.00
Received By shernand Date 2003-07-17 Time 12:59 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-07 Cont ID  
Sent By shernand Date 2003-07-07 Time 12:38 Rev Time 0.00
Received By shernand Date 2003-07-07 Time 12:38 Sent To B
Notes
2003-07-07 00:00:00LMARTINEZ DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-08 Cont ID  
Sent By shernand Date 2003-05-08 Time 14:32 Rev Time 0.00
Received By shernand Date 2003-05-08 Time 14:32 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2003-07-21 Cont ID  
Sent By mmclean Date 2003-07-21 Time 10:23 Rev Time 1.00
Received By mmclean Date   Time   Sent To  
Notes
2003-07-21 00:00:007/21/03 OK PER SHIRLEY GRAHAM MM

Review Stop Z ZONING
Rev No 2 Status F Date 2003-07-07 Cont ID  
Sent By shernand Date 2003-07-17 Time 12:59 Rev Time 1.00
Received By agiannio Date   Time   Sent To  
Notes
2003-07-07 00:00:00RAMP ENCROACHES OVER 50% OF FRONT
 SETBACK.HAVE CONTACTED APPLICANT WITH
 ALTERNATIVE SOLUTION.

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-12 Cont ID  
Sent By shernand Date 2003-05-08 Time 14:32 Rev Time 0.00
Received By sgraham Date   Time   Sent To B
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved