Plan Review Details - Permit 03050285
Plan Review Stops For Permit 03050285
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-06-24 Cont ID  
Sent By jwitmer Date 2003-06-24 Time 06:35 Rev Time 0.75
Received By jwitmer Date 2003-06-24 Time 06:34 Sent To  
Notes
2003-06-24 00:00:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 03050285
 ADDRESS: 6611 TRAVELERS RD
 CONT: INTELI HOMES
 TELL # (561)719-2651
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 ***********PROVISO****************
  
 FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 WHERE THE BEARING CAPACITY OF THE SOIL I
 S NOT DEFINITEY KNOWN, OR IS IN QUESTION
 THE BUILDING OFFICIAL MAY REQUIRE EXPLOR
 ATIONS, TEST OR OTHER ADEQUATE PROOF AS
 TO THE PERMISSIBLE SAFE BEARING
 CAPACITY. REQUIRED TEST AND RECOMMENDA-
 TIONS SUBMITTED TO VERIFY BEARING CAPA-
 CITY SHALL BE CERTIFIED BY A GEOTECH-
 NICALREPORT FROM A DESIGN PROFESSIONAL P
 ROPERLY LICENSED IN THE STATE OF
 FLORIDA.
 ****************************************
 CONTRACTOR CONTINUEING AT OWN RISK!!!!!!
 ****************************************
 ***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-16 Cont ID  
Sent By shernand Date 2003-06-19 Time 15:20 Rev Time 1.25
Received By jwitmer Date 2003-06-16 Time 07:04 Sent To  
Notes
2003-06-16 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03060285
 ADD: 6611 TRAVELER RD
 CONT: INTELLI HOMES
 TEL: (561)242-8877
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) MISSING IMPACT FEE SHEET.
  
 3) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 NO SOILS REPORT PROVIDED, REPORT TO
 STATE THE MINIMUM BEARING VALUE.
  
 4) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORT:
 A) OVERHEAD GARAGE DOOR
  
 5)1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
  
 6)A-6 WINDOW BUCK SLID.GLASS DOOR DETAIL
 1707.4.4.2 TAPERED BUCKS:
 SHALL EXTEND BEYOND THE INTERIOR FACE
 OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS SUPPORTED.
  
 7) SHEET A-2 DETAIL "D", REVISE DETAIL
 TO INDICATE BUCKET WITH FLOOR TRUSSES
 INTERSECTING AT 45 DEGREES.
  
 8) SSHEET S-2 DETAIL #1, HAS FIRE CUT AT
 WRONG POSITION.
  
 9)SHEET A-5 STUCCO NOTE# 5,CHAP.2504.2.2
 SHALL COMPLY WITH ASTM C-1063.
 RIB LATH SPACED @ 4" O.C. (EVERY RIB)
  
 10) SHEET A-5 STUCCO NOTE#7 CHAP2504.2.2
 SHALL COMPLY WITH 7.10.1.1 ATTACH ALL
 METAL PLASTER BASES TO SUPPORTS AT NO
 MORE THAN 7 IN. ALONG SUPPORTS EXCEPT
 FOR 3/8" RIB LATH THAT SHALL BE ATTACHED
 AT EACH RIB (4").
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)659-8096 X 8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-10-02 Cont ID  
Sent By dpalmer Date 2003-10-02 Time 07:39 Rev Time 0.50
Received By dpalmer Date 2003-10-02 Time 07:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-19 Cont ID  
Sent By csiegber Date 2003-09-23 Time 16:44 Rev Time 0.25
Received By dpalmer Date 2003-05-19 Time 06:09 Sent To P
Notes
2003-05-19 00:00:00*********** PROVISO /REVISION ********
  
 1) NOTE: PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2`,6`,12` RULE PER 210-52.
  
 2) NOTE: PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2`,6`,12` RULE PER 210-52.
 BR4
  
 3)NOTE PLEASE SEE MISSING DRYER LOAD
 IN CALCUALTIONS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW BEFORE ROUGH ELECTRICAL INSPECT-
 -ION. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-23 Cont ID  
Sent By csiegber Date 2003-09-23 Time 16:44 Rev Time 0.00
Received By csiegber Date 2003-09-23 Time 16:44 Sent To E
Notes
2003-09-23 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-19 Cont ID  
Sent By shernand Date 2003-06-19 Time 15:20 Rev Time 0.00
Received By shernand Date 2003-06-19 Time 15:20 Sent To B
Notes
2003-06-19 00:00:00JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-07 Cont ID  
Sent By shernand Date 2003-05-07 Time 15:08 Rev Time 0.00
Received By shernand Date 2003-05-07 Time 15:08 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-29 Cont ID  
Sent By kstevens Date 2003-05-23 Time 17:41 Rev Time 0.50
Received By hmoser Date 2003-05-29 Time 17:25 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-05-23 Cont ID  
Sent By dpalmer Date 2003-05-19 Time 06:09 Rev Time 0.25
Received By kstevens Date 2003-05-23 Time 17:41 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-15 Cont ID  
Sent By shernand Date 2003-05-07 Time 15:08 Rev Time 1.00
Received By mmclean Date   Time   Sent To E
Notes
***NONE***