Plan Review Stops For Permit 03050246 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2005-04-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-04-12 |
Time |
14:25 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2005-04-12 |
Time |
14:25 |
Sent To |
|
|
Notes |
2005-04-12 00:00:00 | REVISION DATED 3/28/05 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2004-02-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-02-20 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2004-02-20 |
Time |
14:09 |
Sent To |
|
|
Notes |
2004-02-20 00:00:00 | SEE PROVISO, PREVIOUS REVIEW | | | | PENDING ZONING STAMP | | ZONING STAMP OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2004-02-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-02-20 |
Time |
12:28 |
Rev Time |
3.00 |
Received By |
shill |
Date |
2004-02-20 |
Time |
12:28 |
Sent To |
|
|
Notes |
2004-02-20 00:00:00 | PROVISO | | | | SINKS REQUIRED TO BE ACCESSIBLE ARE TO | | COMPLY WITH FBC11-4.24, SUBMIT DETAILS. | | | | BALUSTER GUARDRAIL TO COMPLY WITH | | FBC1608.2.2. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2003-12-18 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-14 |
Time |
14:35 |
Rev Time |
3.00 |
Received By |
shill |
Date |
2003-12-18 |
Time |
13:41 |
Sent To |
|
|
Notes |
2003-12-18 00:00:00 | *****CORRECTIONS****** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)THE HANDRAIL DETAIL ON SHEET A1.1 | | IS TO COMPLY WITH 1608.2.1. | | | | 2.)INCLUDE A TITLE BLOCK ON SHEETS | | FS1,FS2,FS3 AND SEAL THE CONCRETE FLOOR | | SYSTEM SHEETS, FS61G15-23.002. | | | | 3.)SEE THE PREVIOUS LIST, HOW WILL | | THE #4@12" OC TERMINATE IN THE B1 BEAM | | FOR THE BALCONY SHOWN ON SHEET S1.1? | | NOT ADDRESSED. | | | | 4.)SEE THE PREVIOUS LIST IN REGARDS | | TO THE BALUSTRADE DETAIL.EMBEDMENT AT | | THE TOP WAS GIVEN BUT NOT EMBEDMENT AT | | THE BOTTOM.SEE 1608.2.2 FOR MINIMUM | | DESIGN LOADING AND PROVIDE SUPPORTING | | CALUCLATIONS TO DEMONSTRATE COMPLIANCE | | WITH SAME.SEE ALSO FBC1015 FOR MINIMUM | | GUARDRAIL DIMENSIONS AND NOTE SAME IN | | THE DESIGN CRITERIA. | | | | 5.)THE ENERGY CALC TOTAL SQUARE | | FOOTAGE DOES NOT APPEAR TO BE THE SAME | | AS THE A/C AREA ON THE PLAN.ADDRESS. | | | | 6.)WHEN MAKING CHANGES, IN ORDER TO | | EXPEDITE PLAN REVIEW, CLEARLY CLOUD AND | | NUMBER ALL REVISIONS.SUBMIT OLD SHEETS | | (APPROVED ZONING AND IMPACT FEE STAMP | | ARE NOT ON THIS SET AND ARE REQUIRED | | BEFORE THE PERMIT CAN BE ISSUED). | | | | 7.)SUBMIT THE FOLLOWING PRODUCT | | APPROVALS: | | MULLIONS | | FIXED GLASS | | GLASS BLOCK | | | | 8.)NOTICE OF COMMENCEMENT IS EXPIRED | | (90 DAYS WITHOUT COMMENCING WORK), | | FS713.13. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-09-30 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-09-30 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-09-30 |
Time |
13:28 |
Sent To |
|
|
Notes |
2003-09-30 00:00:00 | SHEET A1.0 NOW DECLARES UL DESIGN U 906 | | FOR THE FIRE RATED STAIRS.U 906 | | INVOKES 6" PROPRIETARY BLOCK FOR THE | | DESIGN. | | THE PLANS INDICATE 8" BLOCK FOR THE | | STRUCTURAL.PLEASE REVISE AS NECESSARY. | | | | SHEET A1.0 CALLS FOR HANDRAILS TO BE | | DESIGNED FOR 50 PLF IN ANY DIRECTION. | | THIS DOES NOT COMPLY WITH FBC 1608.2.1. | | | | THE 90# LIVE LOAD SHOWN FOR THE STORAGE | | AREA ON SHEET A2.0 IS LESS THAN THE | | MINIMUM 125# LIVE LOAD FOR LIGHT | | STORAGE IN FBC TABLE 1604.1. | | PLEASE REVISE AS NECESSARY. | | | | SHEET A1.1 MAKES NOTE OF FIRE | | SPRINKLERSIF THE BUILDING IS TO HAVE | | FIRE | | SPRINKLERS, THE DESIGN IS REQUIRED TO | | BE ON THE PERMIT PLANS.SEE FBC | | 104.3.1.1 #4. | | | | AS PREVIOUSLY NOTED, SEE FBC 104.2.1.1 | | FOR THE ROOF COVERING DESIGN | | INFORMATION NECESSARY ON THE PLANS. | | | | THE PREVIOUS CHECK LIST REQUESTED THE | | DESIGN INFORMATION FOR THE PRE-CAST | | CONCRETE FLOOR SYSTEM.SEE CHAPTER | | 61G15-30 RESPONSIBILITY RULES COMMON TO | | ALL ENGINEERS, OF THE FL ADMINISTRATIVE | | CODE AS PERTAINS TO DELEGATING | | ENGINEERING REQUIREMENTS. | | | | HOW WILL THE #4@12" OC TERMINATE IN | | THE B1 BEAM FOR THE BALCONY SHOWN ON | | SHEET S1.1? | | | | THE BALUSTRADE CONNECTION DETAIL ON | | SHEET A1.1 IS SOMEWHAT VAGUE WITH ITS | | >>1/2" DOWEL TOP AND BOTTOM <<.WHAT | | ISTHE EMBEDMENT DEPTH OF THE DOWEL(S)? | | WILL THEY BE CAST IN PLACE?SEE FBC | | 1608.2.2 FOR MINIMUM DESIGN LOADING AND | | PROVIDE SUPPORTING CALCULATIONS TO | | DEMONSTRATE COMPLIANCE WITH SAME. | | SEE ALSO, FBC 1015 FOR MINIMUM GUARD | | RAIL DIMENSIONS AND NOTE SAME IN THE | | DESIGN CRITERIA. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-06-09 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-06-09 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-06-06 |
Time |
15:08 |
Sent To |
|
|
Notes |
2003-06-09 00:00:00 | PLEASE PROVIDE A COPY OF THE PAID | | IMPACT FEE RECEIPT FROM PALM BEACH | | COUNTY. | | | | THE BUILDING WILL BE LOCATED IN AN A8 | | FLOOD ZONE WITH AN 15.0' BASE FLOOD | | ELEVATION RELATIVE TO NGVD. | | | | THE BUILDING WILL BE A TWO STORY MIXED | | OCCUPANCY OF B/M/S. | | | | PLEASE SHOW A LAYOUT OF THE PROPOSED | | RACK STORAGE CALLED OUT ON SHEET A1.0 | | SO THA EGRESS REQUIREMENTS MAY BE | | DETERMINED. ALSO, INDICATE THE | | QUANTITIES AND NATURE OF THE | | COMMODITIES TO BE STORED.SEE FBC | | 104.2. | | | | WHAT WILL THE ROOM SHOWN AS | | "CONSTRUCTION" BE USED FOR?WHERE IS | | THE EXIT DOOR? | | | | IS THE AREA SHOWN AS "CONCRETE LID" ON | | SHEET A2.0 INTENDED FOR STORAGE OR | | ANOTHER OCCUPANCY/USE?IF SO INDICATE | | THE MINIMUM DESIGN LOADS AND | | ACCESS/EGRESS. | | | | PLEASE PROVIDE DETAILS FOR THE STAIRS | | INCLUDING RISE, RUN, HANDRAILS, FIRE | | RATED ENCLOSURE PROTECTION,DESIGN | | LOADS AND CONNECTION DETAILS. | | | | SHEET S1.1.SHOW THE DIMENSIONS FOR | | THESECOND FLOOR BALCONY AND THE GUARD | | RAIL DETAILS. | | | | SHOW HOW HURRICANE MISSILE IMPACT | | RESISTANCE WILL BE ACCOMPLISHED FOR THE | | EXTERIOR GAZED PORTIONS OF THE | | BUILDINGS.SEEFBC 1606.1.4. | | | | PROVIDE THE STRUCTURAL INFORMATION ON | | THE PLANS CALLED FOR IN FBC 1606.1.7. | | | | PLEASE PROVIDE THE ROOF COVERING DETAILS | | IN ACCORDANCE WITH FBC 104.2.1.1. | | | | SHOW THE END BEARING DETAIL AND | | CONNECTION FOR THE BAR JOISTS. | | | | SHEET S1.1.HOW IS THE TS COLUMN | | ATTACHED TO THE WF BEAM? | | | | SHOW THE DESIGN SPECIFICATIONS FOR THE | | PRECAST CONCRETE AND THE CONNECTION | | BEARING DETAILS. | | | | SHOW A REINFORCEMENT DETAIL FOR THE | | CANTILEVERED 6" SLAB AND THE BALCONY. | | | | SHOW THE FIRE RATED DOORS FOR THE STAIR | | SHAFTS.SEE FBC TABLE 705.1.2. | | | | SHOW THE FIRE DESIGN NUMBER(S) FOR THE | | STAIR AND ELEVATOR SHAFTS. | | | | SHOW THE FIRE SEPARATION, AND FIRE | | DESIGN NUMBER FOR THE MIXED OCCUPANCY | | SEPARATION.SEE FBC 704.1.1. | | | | SHOW THE INSTALLATION INFORMATION FOR | | THE GLASS BLOCK.SEE FBC 2112.5. | | | | PLEASE PROVIDE SPECIFIC DESIGN | | INFORMATION FOR THE "UNISTRUT WITH 5/8 | | GYP BOARD" SHOWN ON SHEET A2.0. | | | | S1.1 AND S1.2.HOW IS THE TOP OF THE | | PARAPET WALL FINISHED?LATERAL | | REINFORCEMENT? |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
P |
Date |
2005-08-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-08-17 |
Time |
12:42 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2005-08-17 |
Time |
12:42 |
Sent To |
|
|
Notes |
2005-08-17 00:00:00 | ADDED REVISED SHEETS INTO SETS. | | | | SEE MECH COMMENTS, | | COMPUTER TO BE REVISED TO INCLUDE TENANT | | BLD-OUT UNDER THIS PERMIT AND ANY | | VALUATION ADJUSTMENT FOR TENANT BLD-OUT. | | THIS WAS OK'D PER LUIS MARTINEZ |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
F |
Date |
2005-08-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-08-04 |
Time |
17:50 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2005-08-04 |
Time |
17:50 |
Sent To |
|
|
Notes |
2005-08-04 00:00:00 | ********** UNSAT ********** | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | REVIEWS AND SEE NEW NOTES DUE TO CHNAGES | | IN PLANS. | | **PLEASE SEE PLANS ARE FOR FINAL/ CO AND | | ALL ON PLANS MUST BE CORRECTED AT 100%. | | | | 1)NOTE: PLEASE SEE NO "EQUIPMENT | | GROUNDING CONDUCTORS" ARE INSTALLED | | UNTIL AFTER THE FIRST MEANS OF | | DISCONNECT. PLEASE SEE 250.6,250.24, SEE | | RISER DIAGRAM. | | | | 2)NOTE: PLEASE SEE SEC'S SHOWN FROM FPL | | TO GUTTER?? PLEASE SEE 2-SETS OF 3/0'S | | ARE ONLY RATED FOR 400AS' AND SERVICE | | SHOWS MIN LOADS AFTER ALL DERATINGS OVER | | 400A'S. | | PLEASE SEE 240.4,310.16 FOR MIN SEC'S | | REQUIRED. | | | | 3)NOTE: PLEASESEE 250.66 FOR ANY | | ADJUSTMENT IN GROUNDINGELECTRODE | | CONDUCTOR? PLEASE SEE ORIGINAL SET WAS | | REDLINED DUE TO INCORRECT SIZE SHOWN. | | | | 4)NOTE: PLEASE SEE MISSING AIC RATING | | FOR MAIN DISCONNECT FEEDING PANEL "D". | | 110.9, 215.5 | | | | 5)NOTE: PLEASE CORRELATE PANEL "C" WITH | | RISER DIAGRAM. PLEASESEE A MCB IS | | REQUIRED FOR GROUPING OF MAINS ETC. | | 230.72,215.5 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2005-04-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-04-04 |
Time |
11:41 |
Rev Time |
1.50 |
Received By |
dpalmer |
Date |
2005-04-04 |
Time |
09:26 |
Sent To |
|
|
Notes |
2005-04-04 00:00:00 | ******* UNSAT ********* | | | | 1)NOTE: PLEASE SEE REVISION TO SPACE IS | | TO BE SUBMITTED UNDER A SEPARATE PERMIT | | AS NOTED ON ORIGINAL BLDG PLANS. | | | | 2)NOTE: PLEASE ALSO SUBMIT REVISED | | PLANS/RISER FOR BASE BLDGS. | | | | 3)NOTE: PLEASE SEE EQUIPMENT GROUNDING | | CONDUCTORS ARE ONLY INSTALLED AFTER THE | | FIRST MEANS OF DISCONNECT. 250.6,250.24 | | | | 4)NOTE: PLEASE SEE MIN GROUNDING | | ELECTRODE CONDUCTOR PER 250.66. | | THIS WAS ON ORIG THREE REVIEWS AND | | REDLINED ON PERMITTED PLANS. | | 250.66 MIN 1/0 (MISPRINT)? | | | | 5)NOTE: PLEASE VERIFY LOCATION OF NEW | | TRANSFER SWITCH. PLEASE SHOW AS EITHER | | MANUAL?AUTO? PLEASE SUBMIT SPECS | | SHEETS FOR TRANSFER SWITCH, SHOWONG IF | | IT IS "SERVICE ENT RATED" | | PLEASE VERIFY IF TRANSFER SWITCH IS | | INDEED ON LOAD SIDE OF SERVICE DISC? | | | | 6)NOTE: PLEASE INCLUDE ALL CONDUCTORS | | FROM GUTTER TO MAINS ETC. | | 215.5,310.16 | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | REVIEWERS WHICH MAY AFFECT ELECTRICAL | | PLANS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-02-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-02-19 |
Time |
11:34 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-02-19 |
Time |
11:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2003-11-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-11-05 |
Time |
15:13 |
Rev Time |
2.00 |
Received By |
dpalmer |
Date |
2003-11-05 |
Time |
15:13 |
Sent To |
|
|
Notes |
2003-11-05 00:00:00 | ************** UNSAT *********** | | | | PLEASE NOTE: OWES RESUB FEE, DID NOT | | GET ACCESSED WHEN RESUBMITTED. | | | | PLEASE NOTE: PER FS 713, IF WORK HAS | | NOT COMMENCED W/IN 90 DAYS OF RECORDING | | NOC, A NEW RECORDED NOC IS REQ'D BEFORE | | PICKING UP PERMIT. | | | | 1)NOTE: PLEASE SEE RISER DIAGRAM WHICH | | HAS NOW BEEN REVISED TO ADDRESS PREVIOUS | | COMMENTS. | | RISER NOW SHOWS EQUIPMENT GROUNDING | | CONDUCTORS BEFORE THE FIRST MEANS OF | | DISCONNECT WHICH IS NOW PARALLELING THE | | NEUTRAL? PLEASE SEE ORIG COMMENT, ASK | | FOR MISSING EQUIPMENT GROUNDING FROM | | MAIN DISC'S TO PANELS.250.110,250.122. | | PER 250.24 | | | | 2)NOTE: PLEASE SEE RISER, NOW SHOWS A | | #3 ALONG WITH THE 4 500MCM CONDUCTORS | | FROM GUTTER TO METER AND THEN TO GUTTER | | ON LOAD SIDE OF K-7? PLEASE CLARIFY | | WHAT THIS #3 CONDUCTOR IS??? | | PLEASE ALSO SEE 250.24 | | | | 3)NOTE: PLEASE SEE PLANS AND SHOW | | LOCATION OF SIGN CIRCUIT. IT IS NOTED | | THAT PANEL SCHEDULE SHOWS CIRCUIT | | HOWEVER THIS COULD NOT BE LOCATED ON | | PLANS. | | | | 4)NOTE: PLEASE SHOW ALL CIRCUITING ON | | PLANS. PLEASE ALSO SEE 700.12E | | PLEASE SEE ONE SET OF PLANS HAS A FEW | | OF THESE ITEMS HIGHLIGHTED. | | | | 5)NOTE: PLEASE CORRELATE SYMBOLS ON | | PLANS AND SYMBOL LIST. | | | | SOME OF THE ABOVE NOTES ARE FROM FIRST | | TWO REVIEW. A NOTICE WAS GIVEN ON PREVI- | | -OUS REVIEW IN REF TO FS 553.80(2)(B) | | PLEASE SEE AS PER FS A 4X FEE MUST NOW | | BE ASSESSED AND MUST BE PAID BEFORE | | RESUBMITTING FOR NEXT REVIEW. | | PLEASE SEE BZ ATTACHED $11,924.42, THIS | | FEE MAY BE ADJUSTED DUE TO VALUATION | | ADJUSTMENT ON PERMIT FEE. | | NEW COMMENT: | | 1)NOTE: PLEASE KNOW THAT PER FS 471.025 | | AND FAC 61G15-23.002, A NOTICE FROM THE | | FBPE'S HAS BEEN GIVEN TO THIS OFFICE | | AND REQUIRE'S ENGINEER TO SIGN PLANS | | WITH A SIGNATURE AND INITIALS ARE NOT | | ACCEPTABLE. MUST SIGN A MIN OF FIRST | | AND LAST NAME AS RECORDED ON SAID SEAL. | | | | PLEASE TAKE ALL OLD /VOIDED SHEETS OUT | | AND INSERT NEW SHEETS INTO COMPLETE | | SETS FOR REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW.IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-09-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-09-29 |
Time |
16:19 |
Rev Time |
2.00 |
Received By |
dpalmer |
Date |
2003-09-29 |
Time |
16:19 |
Sent To |
|
|
Notes |
2003-09-29 00:00:00 | ************* UNSAT ******************* | | | | PLEASE SEE THAT SOME NOTES FROM FIRST | | REVIEW NEED TO BE ADDRESSED. | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | PLANS AND CORRELATE WITH PANEL SCHEDULES | | SUBMITTED. | | IE, ACCU-1 ON ROOF SHOWN ON GFI RECEPT | | CIRCUIT. PLEASE GO THROUGH OTHERS. | | | | 2)NOTE: PLEASE SEE 700.12E FOR CIRCUIT- | | -ING OF EM/EXT LTS. | | PLEASE ALSO SEE 700.16 STAIRWAY? | | | | 3)NOTE: PLEASE SEE SERVICE LOCATION | | OUTSIDE, APPEARS TO ONLY SHOW ONE METER | | AND THREE PANELS/ORDISCS. | | | | 4)NOTE: PLEASE SEE /CLARIFY MEANS OF | | EEQUIPMENT GROUNDING FROM MAIN DISC'S TO | | PANELS. 250.24/250.110/250.122 | | | | 5)NOTE: PLEASE CLARIFY LOCATION OF REQ'D | | SIGN CIRCUIT 600.5 | | | | 6)NOTE: PLEASE SEE FIRE PLAN REVIEW | | NOTES THAT WILL HAVE AN AFFECT ON | | ELECTRICAL PLANS. | | | | 7)NOTE: CIRCUIT FOR OUTSIDE WALLPACKS | | IS NOW SHOWN ,HOWEVER HOW ARE THESE | | CONTROLLED? PC/TC? ARE THEY ON 24/7? | | | | 8)NOTE: PLEASE CLARIFY WHAT APPEARS TO | | BE A FAN OUTSIDE NEXT TO SERVICE? | | | | 9)NOTE: PLEASE CORRELATE SYMBOLS FOR | | EXIT LTS AND ANY OTHERS. | | PLEASE CLARIFY MEANS OF LIGHTING STAIR- | | WAY. LS 101 5-8 | | | | 10)NOTE: PLEASE SEE ATTACHED COPY OF | | FS 553.80(2)(B) WITH RESPECT TO DESIGN | | PROFESSIONALS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | PLEASE NOTE, MAX FUTURE TENANT TO BE | | 100A'S. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-05-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-05-13 |
Time |
06:46 |
Rev Time |
2.00 |
Received By |
dpalmer |
Date |
2003-05-13 |
Time |
06:46 |
Sent To |
|
|
Notes |
2003-05-13 00:00:00 | ************* UNSAT ****************** | | | | 1)NOTE: PLEASE INCLUDE LICENSE # IN | | TITLE BLOCK FOR ARCH OF RECORD AS REQ`D | | IN FS/ FAC 61G1-16.004/ 481 | | | | 2)NOTE: PLEASE PROVIDE ROOM DESIGNATION | | ON ALL SHEETS. PERMIT APPLICATION | | MENTIONS A SHOWROOM? | | | | 3)NOTE: PLEASE CLARIFY HEIGHTS OF GFI`S | | IN GARAGE. | | | | 4)NOTE: PLEASE SHOW ALL CIRCUITING ON | | PLANS AND CORRELATE W/ SUBMITTE PANEL | | SCHEDULES. PLEASE CIRCUIT ALL EM/ EXT LT | | -S PER 700-16E | | | | | | 5)NOTE: PLEASE SHOW CONTROL AND CIRCUIT- | | ING OF OUTSIDE LIGHTING. | | | | 6)NOTE: PLEASE SEE PLANS, THERE SEEMS | | TO BE CIRCUITING SHOWN IN AREAS THAT DO | | NOT GO TO ANYTHING? | | | | 7)NOTE: PLEASE COMPLETE LOAD CALCULATION | | -S. SHOWN BLANK? | | | | 8)NOTE: PLEASE SHOW MISSING EQUIPMENT | | GROUNDING CONDUCTORS FROM MAIN DISC`S TO | | PANELS. 250-110/250-122 | | | | 9)NOTE: PLEASE CLARIFY SIZE ALLOWED FOR | | FUTURE TENANT/METER AND MAIN DISC? | | PLEASE BE SURE TO SIZE SEC`S FOR FUTURE | | LOADS ALSO. SERVICE IS 400A`S AT PRESENT | | TIME. | | | | 10)NOTE: PLEASE SIZE GROUNDING ELECTRODE | | CONDUCTOR PER 250-66. BASED ON SEC`S | | 310-16 | | | | 11)NOTE: PLEASE SHOW GROUNDING ELECTRODE | | TO FOOTER STEEL AND COLD WATER ETC | | AS PER 250-50 AND ALSO ANY BLDG STEEL. | | | | 12)NOTE: PLEASE VERIFY OCP SHOWN FOR | | COND UNITS/ A/C. | | | | MIN 125%. | | PLEASE ALSO SIZE WIRE PER 310-16 (75~) | | | | 13)NOTE: PLEASE SEE LOADING OF TRACK | | LIGHTING CIRCUIT. | | | | 14)NOTE: PLEASE SHOW ALL CONTINUOUS AND | | MOTOR LOADS @125%. (EXT LTS).(ELEV) | | 215-3/230-42 | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | INSERT NEW SHEETS INTO TWO COMPLETE SETS | | FOR REVIEWING AND STAMPING.(MUST BE DONE | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2003-10-21 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2003-10-21 |
Time |
14:28 |
Rev Time |
0.50 |
Received By |
mamini |
Date |
2003-10-21 |
Time |
14:28 |
Sent To |
|
|
Notes |
2003-10-21 00:00:00 | PASSED: | | 1. SEE PERMIT # 03101164 FOR UNDERGROUND | | UTILITIES AND SITE WORK . | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2003-09-11 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2003-09-11 |
Time |
08:29 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2003-09-11 |
Time |
08:29 |
Sent To |
|
|
Notes |
2003-09-11 00:00:00 | FAILED: | | 1. RESPONSES TO THE PREVIOUS REVIEW | | COMMENTS STISFACTORY EXCEPT COMMENT NO. | | 6 THAT HAS NOT BEEN ADDRESSED. | | A) SUBMIT THREE SETS OF CIVIL PLANS ONLY | | (SHEET SP1.0, SP1.1,SP1.2,) TO THE | | PUBLIC UTILITIES & ENGINEERING AT 1000 | | 45TH STREET ATT: MANNY GONZALEZ | | B)SUBMIT TWO SETS OF THE SAME WITH | | APPROVED STAMP TO US WITH A SEPARATE | | APPLICATION AND APPROPRIATE FEES FOR | | "UNDERGROUND UTILITIES AND SITE WORK | | PERMIT". | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2003-05-06 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2003-05-06 |
Time |
14:59 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2003-05-06 |
Time |
14:59 |
Sent To |
|
|
Notes |
2003-05-06 00:00:00 | FAILED : | | 1. PLEASE PROVIDE STORM WATER | | CALCULATION (WATER QUALITIES) FOR OUR | | REVIEW. | | 2. DRIVEWAY APPROACHES MUST BE | | CONSTRUCTED PER CITY STANDARD, FROM CURB | | CUT TO PROPERTY LINE SHOULD BE 6" | | CONCRETE. | | 2. ALL PARKING STALLS MUST PAINTED WITH | | DOUBLE 4" STRIPES, PER CITY REQUIREMENT. | | 3. A BACKFLOW PREVENTER IN 1" WATER | | SERVICE IS REQUIRED. | | 3. A CLEAN OUT WILL NEED TO BE INSTALLED | | IN THE SANITARY SEWER LATERAL, ON THE | | PROPERTY AT BACK OF SIDEWALK, IF NOT | | ALREADY INSTALLED. | | 4. 6" SEWER LATERAL SHOULD BE CONNECTED | | TO MANHOLE? AS SHOWN DIRECTLY WITHOUT | | USE OF 8X6 REDUCER, PLEASE VERIFY. | | 5. POLLUTION/EROSION PLANS MUST BE ADDED | | TO CIVIL/SITE PLAN, DETAILS, SILT FENCE, | | NOTE TO GC, ECT.PLANS MUST BE | | INSTALLED IN FIELD PRIOR TO ANY EARTH/ | | CONSTRUCTION. | | 6. PLEASE NOTE THAT A SEPARATE PERMIT | | APPLICATION AND FEES FOR UNDERGROUND | | UTILITIES AND SITE WORK IS REQUIRED. | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
6 |
Status |
F |
Date |
2005-08-24 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-08-24 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-08-24 |
Time |
09:40 |
Sent To |
|
|
Notes |
2005-08-24 00:00:00 | ******DENIED****** | | | | | | | | PASSED ON PREVIOUS REVIEW. IT CAN'T BE | | DETERMINED IF REVISIONS HAVE IMPACT ON | | FIRE REVIEW AND LIFE SAFETY. PLEASE | | CLEARLY IDENTIFY CHANGES FOR FUTURE | | REVIEW PROCESS. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
P |
Date |
2005-04-11 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-04-11 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-04-11 |
Time |
16:00 |
Sent To |
|
|
Notes |
2005-04-11 00:00:00 | PASSED PROVISO | | | | 1) ALL REVIEW NOTES FROM 12/24/03 THAT | | HAVE NOT BEEN ADDRESSED, SHALL BE | | COMPLIED WITH PRIOR TO ANY FIELD | | INSPECTIONS. | | | | 2) SEPARATE PERMIT AND DRAWINGS ARE | | REQUIRED FOR AREAS NOT INCLUDED AND | | WITHIN THE SCOPE OF THIS PERMIT AND | | DRAWINGS. | | | | | | MIKE WENNERGREN, A/CAPTAIN | | WPBFR(561) 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2003-12-24 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-12-24 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-12-24 |
Time |
15:53 |
Sent To |
|
|
Notes |
2003-12-24 00:00:00 | 1) THE FIRE DEPARTMENT CONNECTION SHALL | | BE PROVIDED WITH 7'- 6" CLEARANCE. | | | | 2) THE FIRE DEPARTMENT CONNECTION SHALL | | BE WITHIN 150 FEET OF A FIRE HYDRANT. | | | | 3) SEPARATE PLANS AND PERMITS REQUIRED | | FOR FIRE SPRINKLER SYSTEM REMODEL. THE | | FIRE SPRINKLER SYSTEM AND ANY FIRE | | ALARM SYSTEM EQUIPMENT MUST BE UL | | LISTED FOR CENTRAL STATION SERVICE SINCE | | THIS BECAME EFFECTIVE AUGUST 1, 2003. | | | | 4) THE DESIGN TEAM AND OWNER RED-LINED | | THE DRAWINGS ON 12-24-03 AND MADE | | CORRECTIONS TO THE DRAWINGS. | | | | 5) THE BACKFLOW DEVICE FOR THE FIRE | | SPRINKLER SYSTEM IS REQUIRED TO HAVE | | TAMPER SWITCHES AND A CHAIN AND LOCK. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | BUREAU OF FIRE PREVENTION |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
F |
Date |
2003-11-24 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-11-24 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-11-24 |
Time |
16:27 |
Sent To |
|
|
Notes |
2003-11-24 00:00:00 | 1) ONE HOUR DOORS STILL SHOWN AT THE | | GARAGE. THESE DOORS SHALL BE AT LEAST | | 1 1/2 HOURS SINCE THE WALLS ARE | | REQUIRED TO BE AT LEAST TWO HOUR | | FIRE RATED. | | | | 2) DOORS # 13 AND 17 SHALL BE 45 MINUTE | | FIRE RATED. STORAGE IS NOT PERMITTED | | UNDER STAIRS UNLESS THE STORAGE AREA | | IS RATED THE SAME AS THE REQUIRED | | RATING FOR THE STAIRS. | | | | 3) DOOR HARDWARE ON DOORS # 23 AND 26 | | SHALL NOT REQUIRE THE USE OF A KEY, | | TOOL, SPECIAL KNOWLEDGE OR EFFORT. | | DOOR # 23 CANNOT BE LOCKABLE FROM | | WITHIN THE OFFICE. | | | | 4) KNOX-BOX SHOULD BE INSTALLED ON | | ELEVATION WHERE THE ADDRESS IS LOCATED. | | | | 5) FIRE SPRINKLER PLANS ARE REQUIRED | | AT TIME OF PERMIT. SHOP DRAWINGS | | ARE REQUIRED LATER. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2003-09-12 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-09-12 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-09-12 |
Time |
16:06 |
Sent To |
|
|
Notes |
2003-09-12 00:00:00 | 1) PLEASE PROVIDE A LIFE SAFETY PLAN. | | SOME PORTIONS OR AREAS HAVE A SINGLE | | MEANS OF EGRESS. PLEASE EXPLAIN | | RATIONALE. SOME AREAS HAVE A SINGLE | | MEANS OF EGRESS THAT INCLUDE THE RACK | | STORAGE, GARAGE AND FLOOR COVERING | | SHOWROOM. | | | | 2) NO EMERGENCY LIGHTS IN OFFICE, FIRST | | FLOOR. | | | | 3) NO FIRE SPRINKLER PLANS PROVIDED. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2003-06-05 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-06-05 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-06-05 |
Time |
15:30 |
Sent To |
|
|
Notes |
2003-06-05 00:00:00 | 1) DOOR SCHEDULE INDICATES NO RATED | | FIRE DOORS. PLEASE EXPLAIN RATIONALE. | | | | 2) DOORS 19 AND 20 OPPOSE ONE ANOTHER. | | | | 3) A KNOX-BOX WILL BE REQUIRED FOR THE | | BUILDING. | | | | 4) IN SOME OTHER LOCALES DOORS OPPOSE | | ONE ANOTHER. | | | | 5) PLEASE CLEARLY ILLUSTRATE ALL | | EMERGENCY LIGHTS. | | | | 6) PLEASE SHOW HANDRAILS ON BOTH SIDES | | OF ALL STAIRS. | | | | 7) PLEASE SHOW PRESCRIPTIVE STRENGTH | | REQUIREMENTS FOR HANDRAILS. | | | | 8) NO FIRE SPRINKLER PLANS PROVIDED WITH | | PLANS. DRAWINGS ILLUSTRATE A FIRE LINE | | ENTERING THE BUILDING. PLEASE PROVIDE | | REQUIRED INFORMATION. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8097,EXT.8497 | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2005-09-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-12 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-12 |
Time |
14:43 |
Sent To |
M |
|
Notes |
2005-09-12 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2005-08-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-16 |
Time |
08:13 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-16 |
Time |
08:13 |
Sent To |
|
|
Notes |
2005-08-16 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2005-08-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-02 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-02 |
Time |
13:28 |
Sent To |
|
|
Notes |
2005-08-02 00:00:00 | WAITING FOR "COMM" BD | | TO "COMM" BD#28 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2005-03-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-31 |
Time |
12:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-31 |
Time |
12:57 |
Sent To |
|
|
Notes |
2005-03-31 00:00:00 | TO "COMM" BD#36 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2004-02-11 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-11 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-11 |
Time |
15:53 |
Sent To |
|
|
Notes |
2004-02-11 00:00:00 | TO COMM BD#33 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2004-01-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-01-14 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2004-01-14 |
Time |
15:15 |
Sent To |
|
|
Notes |
2004-01-14 00:00:00 | SUBMITTALS PUT WITH PLANS WHICH HAVE | | NOT BEEN PICKED UP BY CONTRACTOR |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2004-01-14 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-14 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-14 |
Time |
14:35 |
Sent To |
B |
|
Notes |
2004-01-14 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-11-04 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-04 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-04 |
Time |
10:47 |
Sent To |
|
|
Notes |
2003-11-04 00:00:00 | TO COMM BD#36 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-09-09 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-09 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-09 |
Time |
11:24 |
Sent To |
|
|
Notes |
2003-09-09 00:00:00 | ON COMM BD#48 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-09-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-03 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-03 |
Time |
12:22 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-05-06 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-06 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-06 |
Time |
10:29 |
Sent To |
|
|
Notes |
2003-05-06 00:00:00 | COMM BOARD #35 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
7 |
Status |
P |
Date |
2005-09-19 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-09-19 |
Time |
12:42 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2005-09-19 |
Time |
10:22 |
Sent To |
|
|
Notes |
2005-09-19 00:00:00 | PROVISO: | | 1.FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | WITH NOTIFICATION TO ALARM/STROBE IS | | REQUIRED PER 2001 FBC(M)606.2.1. | | | | 2.NO COMBUSTIBLES ALLOWED ABOVE THE | | CEILING IN THE RETURN AIR PLENUM - 2001 | | FBC(M)602.2.1. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
F |
Date |
2005-08-17 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-08-17 |
Time |
07:36 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2005-08-17 |
Time |
07:14 |
Sent To |
E |
|
Notes |
2005-08-17 00:00:00 | DENIED: | | 1.PLAN SHEET A-3 , IN THE REVISIONS | | SUBMITTED APPEARS TO BE A NEW SHEET. | | THE ORIGINAL SUBMITTAL A-3.0 IS AN | | ELEVATION PLAN NOT A MECHANICAL HVAC | | PLAN.PLEASE CLARIFY IF THIS IS | | ADDITIONAL WORK THAT WAS NOT COVERED | | UNDER THE ORIGINAL SCOPE OF WORK. | | | | REVISIONS FOR PLAN SHEET MEP2.1, MEP2.2, | | & MEP3.0 ARE APPROVED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
F |
Date |
2005-04-11 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-04-11 |
Time |
14:52 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2005-04-11 |
Time |
14:44 |
Sent To |
|
|
Notes |
2005-04-11 00:00:00 | DENIED: | | PLANS SUBMITTED AS A REVISION.THIS | | SECTION OF THE BUILDING WAS NEVER | | REVIEWED UNDER THE REFERENCED PERMIT | | NUMBER.PLAN SHEET MEP1.1 INDICATES | | "THIS SPACE TO BE BUILT UNDER SEPARATE | | PERMIT". | | | | 1.PLEASE INDICATE LOCATION OF THE | | CONDENSING UNIT.PROVIDE INFORMATION | | FOR THE STAND IF LOCATED ON THE ROOF. | | SHOW COMPLIANCE WITH 2001 FBC 1511.7. | | | | 2.INDICATE ACCESS TO THE ROOF. | | | | 4.FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | REQUIRED PER 2001 FBC/M606.2.1 AND | | SHALL HAVE NOTIFICATION TO ALARM/STROBE | | IN NORMALLY OCCUPIED AREAS 606.4.1 #2. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2003-12-11 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-12-11 |
Time |
16:32 |
Rev Time |
0.20 |
Received By |
pkrauss |
Date |
2003-12-11 |
Time |
16:32 |
Sent To |
|
|
Notes |
2003-12-11 00:00:00 | PER CONVERSATION WITH PETE RUSSO, | | O.A. CALCS FOR ALL AREAS & EQUIPMENT | | SCHEDULE ON PLAN SHEET MEP-3.0. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2003-12-09 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-12-09 |
Time |
06:39 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2003-12-09 |
Time |
06:38 |
Sent To |
|
|
Notes |
2003-12-09 00:00:00 | DENIED: | | PLEASE NOTE COMMENTS 1 AND 2 FROM 1ST | | REVIEW NOT ADDRESSED. | | | | 1.PROVIDE O.A. CALCULATIONS PER 2001 | | FBC(M) 403.3. | | | | 2.PROVIDE CALCULATIONS FOR THE GARAGE | | PER 2001 FBC 411.4.2 MINIMUM OF 6 AIR | | CHANGES PER HOUR OR 403.4. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2003-09-24 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-09-24 |
Time |
07:13 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2003-09-24 |
Time |
07:13 |
Sent To |
|
|
Notes |
2003-09-24 00:00:00 | DENIED: | | 1. PLEASE CLARIFY OUTSIDE AIR TO AHU-1. | | NOTE ON PLAN SHEET MEP 2.1 INDICATES | | O.A. AT CEILING OF THE FIRE PUMP ROOM. | | OUTSIDE AIR NEEDS TO COME FROM OUTSIDE | | THE BUILDING. INTAKE OPENING SHALL BE | | LOCATED A MINIMUM OF 10 FT FROM LOT LINE | | OR BUILDINGS ON THE SAME LOT (2001 FBC/M | | 401.5.) | | | | CLARIFY RETURN AIR FOR AHU-1. WILL THE | | MECHANICAL ROOM BE USED AS A PLENUM? | | MECHANICAL CLOSETS/ROOMS TO COMPLY WITH | | 2001 FBC CHAPTER 13 SUB-SECTION 410.1.AB | | 410.1.ABCD.3.7. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-05-19 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-05-19 |
Time |
15:28 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2003-05-19 |
Time |
14:55 |
Sent To |
|
|
Notes |
2003-05-19 00:00:00 | DENIED:MECHANICAL PERMIT 03050253 | | | | 1.PLEASE PROVIDE OUTSIDE AIR CALCS | | AS PER 2001 FBC(M) TABLE 403.3. | | | | 2.PROVIDE CALCULATIONS FOR AIR CHANGES | | IN GARAGE AREA AS PER TABLE 403.3. | | | | 3.PLAN SHEET MEP3.0 INDICATES EF-1 | | TO RUN 15 MINUTES PER HOUR.AS PER 2001 | | FBC(M) 403.4 MECHANICAL VENTILATION NOT | | REQUIRED TO RUN CONTINUOUSLY WHERE THE | | SYSTEM IS ARRANGED TO OPERATE AUTO- | | MATICALLY UPON DETECTION OF A CONCENTRA- | | TIONOF CARBON MONOXIDE OF 25 (PPM) BY | | APPROVED AUTOMATIC DETECTION DEVICES. | | | | 4.CONDENSER UNIT STANDS ON ROOF SHALL | | COMPLY WITH 2001 FBC 1511.7 FOR THE | | DISTANCE BETWEEN THE ROOF FINISHED | | SURFACE AND THE BOTTOM OF THE SUPPORT | | RAIL. | | | | 5.FIRE DAMPERS ARE NOT INDICATED ON | | PLAN.PLEASE NOTE, FIRE DAMPERS ARE | | REQUIRED WHERE DUCTS PENETRATE A FIRE | | RATED WALL PARTITION OR FLOOR.PLEASE | | SHOW LOCATIONS OF ALL FIRE DAMPERS THAT | | ARE REQUIRED.2001 FBC(M) 607.6 | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. | | E |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2004-02-20 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-02-20 |
Time |
15:03 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2004-02-20 |
Time |
15:03 |
Sent To |
|
|
Notes |
2004-02-20 00:00:00 | PASSED/PROVISO | | | | REVISIONS REQUIRED FOR THE FOLLOWING | | - SHOW STARTING POINT FOR GUTTERS SLOP- | | ING TO DOWNSPOUTS. | | - SUBMIT DETAIL FOR BATHROOM ON SECOND | | FLOOR SHOWING SIZE OF OPENING FOR W/C, | | CLEAR FLOOR SPACE FOR LAV AND W/C, GRAB | | BARS FOR W/C, IF PARALLEL APPROACH FOR | | LAV., LAV TO BE 2' OFF WALL. | | - SUBMIT DETAIL FOR BAR SINK SHOWING | | CLEAR FLOOR SPACE AND IF PARALLEL APPRO- | | ACH SINK SHALL BE 2' OFF WALL TO CENTER | | OF 48" CFS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2004-02-19 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-02-19 |
Time |
16:19 |
Rev Time |
5.00 |
Received By |
kstevens |
Date |
2004-02-19 |
Time |
16:19 |
Sent To |
|
|
Notes |
2004-02-19 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1) FROM PREVIOUS REVIEWS. | | DISPLAY BATHROOM SHOWER DETAILS NOT | | SUBMITTED. SECTION 11-4.21 AND ALL SUB- | | SECTIONS. (COMMENT #2 FROM PREVIOUS RE- | | VIEWS). | | 2) FROM PREVIOUS REVIEWS. | | SUBMIT DETAIL FOR GRAB BARS FOR W/C, | | SHOW LAV HEIGHT AND CLEAR FLOOR SPACE | | FOR LAV AND WATER CLOSET. | | 3) FROM PREVIOUS REVIEWS. | | SUBMIT CALCULATIONS FOR ROOF GUTTERS AND | | DOWNSPOUTS. SHOW TOTAL SQUARE FOOTAGE | | FOR EACH ROOF AREA. AREA OF UPPER ROOF | | THAT DRAINS TO LOWER ROOF SHALL BE ADDED | | WHEN SIZING GUTTERS AND DOWN SPOUTS. | | SHOW IN CALCULATIONS. ALSO SHOW 1/2 AREA | | OF ALL VERTICAL WALLS INCLUDING PARAPETS | | ADDED TO CALCULATIONS. TABLE 1106.2 AND | | TABLE 1106.6. INDICATE PITCH (SLOPE) OF | | GUTTER AND SHOW WHERE THE PITCH TO EACH | | DOWNSPOUT STARTS. (HIGH POINT) | | 4) NEW COMMENT. BAR SINK SHALL COMPLY | | WITH 11-4.24 AND ALL SUBSECTIONS. PROVI- | | DE A DETAIL SHOWING HEIGHT, CLEAR FLOOR | | SPACE, KNEE CLEARANCE, DEPTH, EXPOSED | | PIPES, FAUCETS. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2003-12-06 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-12-06 |
Time |
04:45 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2003-12-06 |
Time |
04:45 |
Sent To |
|
|
Notes |
2003-12-06 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | FBC-2001 BLDG. | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | A) COMMENTS FROM PREVIOUS REVIEW NOT | | ADDRESSED. THE NUMBER SHALL STAY THE | | SAME FOR CLAIRITY. | | 2) IF BATHING ROOMS ARE PROVIDED, THEN | | EACH PUBLIC AND COMMON USE BATHING FAC- | | ILITY SHALL COMPLY WITH 11-4.23. SECTION | | 11-4.1.2(6) - SHOW ALL REQUIREMENTS FOR | | CLEAR FLOOR SPACE 11-4.23.3, SHOWER | | STALLS 11-4.21, SHOWER SEAT 11-4.21.3, | | SHOWER GRAB BARS 11-4.21.4, SHOWER CON- | | TROLS 11-4.21.5, SHOWER UNIT 11-4.21.6, | | CURBS 11-4.21.7, WATER CLOSETS 11-4.23.4 | | 3) SHT A1.0 LOUNGE AND KITCHEN SINKS | | SHALL COMPLY WITH 11-4.24 AND ALL SUB- | | SECTIONS. PROVIDE DETAIL. (THE ONLY DE- | | TAIL SHOWN IS COUNTER HEIGHT. PROVIDE | | DETAIL FOR ALL SUBSECTIONS). | | 4) SHT A1.0 ALL TOILET ROOMS SHALL | | COMPLY WITH 11-4.24, 11-4.16, 11-4.19 | | AND ALL SUBSECTIONS. PROVIDE DETAILS. | | (CLEAR FLOOR SPACE AND TURNING AREAS NOT | | SHOWN FOR ALL TOILET ROOMS). | | 5) SHT A1.1 SEE COMMENT #4. | | 6) SHTA1.2 SUBMIT CALCULATIONS FOR ROOF | | GUTTER AND DOWNSPOUTS. SHOW TOTAL SQUARE | | FOOTAGE FOR EACH ROOF AREA. AREA OF UP- | | PER ROOF THAT DRAINS TO LOWER ROOF SHALL | | BE ADDED WHEN SIZING GUTTERS AND DOWN- | | SPOUTS. SHOW IN CALCULATIONS. ALSO SHOW | | 1/2 AREA OF ALL VERTICAL WALLS INCLUDING | | PARAPETS ADDED TO CALCULATIONS. TABLE | | 1106.2 AND TABLE 1106.6. INDICATE PITCH | | (SLOPE) OF GUTTER AND SHOW WHERE THE | | PITCH TO EACH DOWNSPOUT STARTS. | | ---NEW COMMENTS | | 1B) SIGNATURE REQUIRED ON SEAL PER | | 61G15-23.002(1) - FS471.025 | | 2B) IRRIGATION PERMIT REQUIRED. | | *********WHEN RESUBMITTING PLANS******** | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. (THIS WAS NOT ADDRESSED) | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-10-01 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-10-01 |
Time |
07:54 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2003-09-30 |
Time |
18:51 |
Sent To |
|
|
Notes |
2003-10-01 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | FBC-2001 BUILDING | | FLORIDA ADMIN. CODE | | A) FOLLOWING COMMENTS HAVE NOT BEEN | | ADDRESSED FROM PREVIOUS REVIEW. THE | | NUMBER SHALL STAY THE SAME FOR CLAIRITY. | | 1) PLEASE SUBMIT CALCULATIONS FOR MINI- | | MUM FACILITIES. TABLE 403.1 - INDICATE | | TOTAL AREA FOR EACH OCCUPANCY AND TOTAL | | FIXTURES REQUIRED FOR EACH OCCUPANCY. | | 2) IF BATHING ROOMS ARE PROVIDED, THEN | | EACH PUBLIC AND COMMON USE BATHING FAC- | | ILITY SHALL COMPLY WITH 11-4.23. SECTION | | 11-4.1.2(6). | | 3) SHT A1.0 LOUNGE AND KITCHEN SINKS | | SHALL COMPLY WITH 11-4.24 AND ALL SUB- | | SECTIONS. PLEASE PROVIDE DETAILS. | | 4) SHT A1.0 ALL TOILET ROOMS SHALL | | COMPLY WITH 11-4.24, 11-4.16, 11-4.19 | | AND ALL SUBSECTIONS. PLEASE PROVIDE DE- | | TAILS. | | 5) SHT A1.1 SEE COMMENT #4. | | 6) SHT A1.2 SUBMIT CALCULATIONS FOR ROOF | | GUTTER AND SOWNSPOUTS. SHOW TOTAL SQUARE | | FOOTAGE FOR EACH ROOF AREA. AREA OF UP- | | PER ROOF THAT DRAINS TO LOWER ROOF SHALL | | BE ADDED WHEN SIZING GUTTERS AND DOWN- | | SPOUTS. SHOW IN CALCULATIONS. ALSO SHOW | | 1/2 AREA OF ALL VERTICAL WALLS INCLUDING | | PARAPETS ADD TO CALCULATIONS. TABLE | | 1106.2 AND TABLE 1106.6. INDICATE PITCH | | (SLOPE) OF GUTTER, AND SHOW WHERE THE | | PITCH TO EACH DOWNSPOUT STARTS. | | 7) DOWNSPOUTS SHALL TERMINATE A MINIMUM | | OF 1' FROM THE STRUCTURE SIDEWALL. SEC | | 1503.4.4. PROVIDE A DETAIL. | | 11) SHT MEP3.0 SANT RISER DIAGRAM, ONLY | | FIXTURES FROM THE BATHROOM GROUP SHALL | | DRAIN THROUGH THE HORIZONTAL WET VENT. | | SEC 909.1. 1ST FLOOR KITCHEN SINK SHALL | | CONNECT DOWNSTREAM OF THE TOILET ROOM | | FIXTURES. SEPARATE STACK FOR KITCHEN | | SINK REQUIRED. | | 12) SUPPLY TO HOSE BIBB IN ELECTRICAL | | ROOM IS NOT SHOWN ON SHT MEP2.3 NOR SHT | | MEP3.0 RISER.104.2.1 | | NEW COMMENTS: | | 13) SECTION 606.2(2) SHUTOFF VALVE RE- | | QUIRED FOR HOSE BIBB. | | 14) PLEASE BE AWARE OF FF 553.80(2)(B) | | CONCERNING DESIGN PROFESSIONALS AND PLAN | | REVIEWS. | | | | ---------WHEN RESUBMITTING PLANS-------- | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-06-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-06-04 |
Time |
14:13 |
Rev Time |
2.75 |
Received By |
kstevens |
Date |
2003-06-04 |
Time |
12:56 |
Sent To |
|
|
Notes |
2003-06-04 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) PLEASE SUBMIT CALCULATIONS FOR MINI- | | MUM FACILITIES. TABLE 403.1 - INDICATE | | TOTAL AREA FOR EACH OCCUPANCY AND TOTAL | | FIXTURES REQUIRED FOR EACH OCCUPANCE. | | (ALSO SEE TABLE 1003.1 BLDG CODE) | | 2) IF BATHING ROOMS ARE PROVIDED, THEN | | EACH PUBLIC AND COMMON USE TOILET ROOM | | SHALL COMPLY WITH 11-4.23 | | 3) SHT A1.0 LOUNGE AND KITCHEN SINKS | | SHALL COMPLY WITH 11-4.24 AND ALL SUB- | | SECTIONS. PLEASE PROVIDE DETAILS. | | 4) SHT A1.0 ALL TOILET ROOMS SHALL SHOW | | LENGTH AND WIDTH ON PLANS. ALL TOILET | | ROOMS SHALL COMPLY WITH 11-4.22 AND ALL | | SUBSECTIONS. PLEASE PROVIDE DETAILS. | | 5) SHT A1.1 - SEE COMMENT #4. | | 6) SHT A1.2 SUBMIT CALCULATIONS FOR ROOF | | GUTTER AND DOWNSPOUTS. SHOW SQUARE FOOT- | | AGE FOR EACH ROOF AREA. AREA OF UPPER | | ROOF THAT DRAINS TO LOWER ROOF SHALL BE | | ADDED WHEN SIZING GUTTERS AND DOWNSPOUTS | | OF LOWER ROOF. BE SURE TO SHOW THIS IN | | THE CALCULATIONS. TABLE 106.2 & TABLE | | 1106.6. INDICATE PITCH OF GUTTER, AND | | SHOW WHERE THE PITCH TO EACH DOWNSPOUT | | STARTS. | | 7) DOWNSPOUTS SHALL TERMINATE A MINIMUM | | OF 1' FROM BLDG WALL. SEC 1503.4.4 | | 8) SHT A1.2 SHOWS ROOF DRAIN ON RIGHT | | SIDE OF LOWER ROOF. IT STATES SEE MECH. | | DRAWINGS. UNABLE TO LOCATE ON MECH. | | DRAWINGS. PLEASE CLAIRFY. | | 9) SHT MEP2.4 PLUMBING NOTES #16, SEPAR- | | ATE PERMIT/PLANS REQD. FOR GAS. 104.1.1 | | 10) SHT MEP3.0 WATER HEATER IN LOUNGE TO | | BE ACCESSIBLE. SEC 501.4 - SUBMIT DETAIL | | 11) SHT MEP3.0 SANT RISER DIAGRAM, ONLY | | FIXTURES FROM THE BATHROOM GROUP SHALL | | DRAIN THROUGH THE HORIZONTAL WET VENT. | | SEC 909.1 - 1ST FLOOR KIT. SINK, SECOND | | FLOOR LOUNGE, & SECOND FLOOR BATHROOM | | SHALL ALL TIE IN DOWNSTREAM OF WET VENT. | | 12) SHT MEP3.0 WATER RISER DIAGRAM, 1ST | | FLOOR W/C AND LAV NOT SHOWN ON RISER. | | HOSE BIBB IN ELECTRIC ROOM? PLEASE | | CLAIRFY. IF H.B. IS FOR GROUND A HARD | | CAP IS SUGGESTED. NO SUPPLY TO H.B. IS | | SHOWN ON RISER DIAGRAM. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2003-09-09 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-09-09 |
Time |
09:38 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-09-09 00:00:00 | PROVISO: S/W EASEMENT MUST BE SUBMITTED | | BEFORE C/O ISSUED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2003-09-08 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-09-08 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-09-08 00:00:00 | DENIED, NEED INFORMAL SITE REVIEW | | CALLED 9-8-2003 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2003-05-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-03 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-05-16 00:00:00 | 5/16/03 DENIED NEED EASEMENT (1) INFO MM | 2003-05-12 00:00:00 | DENIED, NEED EASEMENT INFORMATION |
|
|