Plan Review Details - Permit 03050107
Plan Review Stops For Permit 03050107
Review Stop B BUILDING (STRUCTURAL)
Rev No 116 Status P Date 2006-10-28 Cont ID  
Sent By rbrown Date 2006-10-28 Time 21:32 Rev Time 0.00
Received By rbrown Date 2006-10-28 Time 21:32 Sent To  
Notes
2006-10-28 21:33:31SUBMITTAL ON 10/19/06 FOR ROOF LEVEL ACCESSIBLE RAMPS
 (ORIGINALLY SUBMITTED ON 10/3/06, BUT DENIED)

Review Stop B BUILDING (STRUCTURAL)
Rev No 115 Status P Date 2006-10-28 Cont ID  
Sent By rbrown Date 2006-10-28 Time 21:30 Rev Time 0.00
Received By rbrown Date 2006-10-28 Time 21:30 Sent To  
Notes
2006-10-28 21:31:35SUBMITTAL ON 10/13/06 FOR MECHANICAL PIPE STANDS

Review Stop B BUILDING (STRUCTURAL)
Rev No 114 Status F Date 2006-10-09 Cont ID  
Sent By rbrown Date 2006-10-11 Time 20:37 Rev Time 0.00
Received By rbrown Date 2006-10-09 Time 20:37 Sent To  
Notes
2006-10-09 21:00:41BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6652
 E-MAIL: [email protected]
  
 SUBMITTAL ON 10/3/06 FOR ROOF LEVEL ACCESSIBLE RAMPS.
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 1) 61G15-23.002(2)FL. ADMIN. CODE.
 THE ENGINEER'S SIGNATURE ON THE CLACULATIONS IS
 PHOTOCOPIED.ORIGINAL SIGNATURES ARE REQUIRED.ALSO,
 EITHER EACH SHEET OF THE CALCULATIONS SHALL BE SIGNED
 AND SEALED OR THE ENGINEER SHALL SIGN AND SEAL AN INDEX
 SHEET LISTING EACH SHEET NUMBER INCLUDED IN THE
 CALCULATION REPORT.
 (471.025 F.S. AND 471.023 F.S.).
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO TELEPHONE:
 (561) 805 6652ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 113 Status F Date 2006-08-27 Cont ID  
Sent By rbrown Date 2006-08-27 Time 15:41 Rev Time 0.00
Received By rbrown Date 2006-08-27 Time 15:41 Sent To  
Notes
2006-08-27 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6652
 E-MAIL: [email protected]
  
 REVISION SUBMITTED ON 8/18/06 FOR SHEET
 A.04.
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 1) FBC 704.2.4 AND 705.1.2EXIT ACCESS
 CORRIDOR.THE BUSINESS CENTER DOOR WAS
 SPECIFIED ON SHEET A.48 AS A MIN. 20
 MINUTE FIRE-RATED DOOR BECAUSE IT IS ON
 AN EXIT ACCESS CORRIDOR.THE DOOR SHALL
 NOT BE OMITTED.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6652ROBERT BROWN
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 112 Status P Date 2006-08-20 Cont ID  
Sent By rbrown Date 2006-08-20 Time 21:36 Rev Time 0.00
Received By rbrown Date 2006-08-20 Time 21:36 Sent To  
Notes
2006-08-20 00:00:00SUBMITTAL FOR EXTERIOR METAL STUD
 FRAMING SPECS.SIGNED AND SEALED
 ORIGINALS WERE STAMPED AND RETURNED ON
 6/25/06

Review Stop B BUILDING (STRUCTURAL)
Rev No 111 Status P Date 2006-08-20 Cont ID  
Sent By rbrown Date 2006-08-20 Time 21:13 Rev Time 0.00
Received By rbrown Date 2006-08-20 Time 21:13 Sent To  
Notes
2006-08-20 00:00:00SUBMITTAL ON 4/22/06 FOR METAL BIFOLD
 DOORS ON AC CLOSETS

Review Stop B BUILDING (STRUCTURAL)
Rev No 110 Status P Date 2006-08-20 Cont ID  
Sent By rbrown Date 2006-08-20 Time 21:12 Rev Time 0.00
Received By rbrown Date 2006-08-20 Time 21:12 Sent To  
Notes
2006-08-20 00:00:00ARCHITECTURAL REVISION SUBMITTED ON
 7/31/06

Review Stop B BUILDING (STRUCTURAL)
Rev No 109 Status P Date 2006-08-20 Cont ID  
Sent By rbrown Date 2006-08-20 Time 21:11 Rev Time 0.00
Received By rbrown Date 2006-08-20 Time 21:11 Sent To  
Notes
2006-08-20 00:00:00ARCHITECTURAL REVISION SUBMITTED ON
 6/30/06

Review Stop B BUILDING (STRUCTURAL)
Rev No 108 Status P Date 2006-08-20 Cont ID  
Sent By rbrown Date 2006-08-20 Time 19:57 Rev Time 0.00
Received By rbrown Date 2006-08-20 Time 19:57 Sent To  
Notes
2006-08-20 00:00:00ARCHITECTURAL REVISION SUBMITTED ON
 6/22/06

Review Stop B BUILDING (STRUCTURAL)
Rev No 107 Status P Date 2006-08-20 Cont ID  
Sent By rbrown Date 2006-08-20 Time 19:56 Rev Time 0.00
Received By rbrown Date 2006-08-20 Time 19:56 Sent To  
Notes
2006-08-20 00:00:00ARCHITECTURAL REVISION SUBMITTED ON
 4/11/06

Review Stop B BUILDING (STRUCTURAL)
Rev No 106 Status P Date 2006-06-25 Cont ID  
Sent By rbrown Date 2006-06-25 Time 14:33 Rev Time 0.00
Received By rbrown Date 2006-06-25 Time 14:33 Sent To  
Notes
2006-06-25 00:00:00STRUCTURAL SUBMITTAL FOR ALUMINUM
 TRELLIS AT COURTYARD

Review Stop B BUILDING (STRUCTURAL)
Rev No 105 Status P Date 2006-06-25 Cont ID  
Sent By rbrown Date 2006-06-25 Time 14:33 Rev Time 0.00
Received By rbrown Date 2006-06-25 Time 14:32 Sent To  
Notes
2006-06-25 00:00:00STRUCTURAL SUBMITTAL FOR SUPPORT OF
 GENERATOR EXHAUST EXTENSION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 104 Status P Date 2006-06-25 Cont ID  
Sent By rbrown Date 2006-06-25 Time 14:31 Rev Time 0.00
Received By rbrown Date 2006-06-25 Time 14:31 Sent To  
Notes
2006-06-25 00:00:00SUBMITTAL FOR EXTERIOR METAL STUD
 FRAMING AT ROOFTOP CABANA AND ELEVATOR
 LOBBIES

Review Stop B BUILDING (STRUCTURAL)
Rev No 103 Status P Date 2006-06-25 Cont ID  
Sent By rbrown Date 2006-06-25 Time 13:48 Rev Time 0.00
Received By rbrown Date 2006-06-25 Time 13:48 Sent To  
Notes
2006-06-25 00:00:00SUBMITTAL FOR CEILING IN ROOFTOP
 ELEVATOR LOBBIES

Review Stop B BUILDING (STRUCTURAL)
Rev No 102 Status P Date 2006-06-25 Cont ID  
Sent By rbrown Date 2006-06-25 Time 13:38 Rev Time 0.00
Received By rbrown Date 2006-06-25 Time 13:38 Sent To  
Notes
2006-06-25 00:00:00SUBMITTAL FOR ELEVATOR SHAFT ACCESS DOOR
 CUT DOWN.

Review Stop B BUILDING (STRUCTURAL)
Rev No 101 Status P Date 2006-06-25 Cont ID  
Sent By rbrown Date 2006-06-25 Time 13:31 Rev Time 0.00
Received By rbrown Date 2006-06-25 Time 13:31 Sent To  
Notes
2006-06-25 00:00:00SUBMITTAL FOR SPA SIGNAGE STAND MOUNTED
 ON POOL DEECK

Review Stop B BUILDING (STRUCTURAL)
Rev No 100 Status P Date 2006-06-25 Cont ID  
Sent By rbrown Date 2006-06-25 Time 13:26 Rev Time 0.00
Received By rbrown Date 2006-06-25 Time 13:26 Sent To  
Notes
2006-06-25 00:00:00SUBMITTAL FOR BILCO ROOF HATCH SHOP
 DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 99 Status P Date 2006-06-25 Cont ID  
Sent By rbrown Date 2006-06-25 Time 13:19 Rev Time 0.00
Received By rbrown Date 2006-06-25 Time 13:19 Sent To  
Notes
2006-06-25 00:00:00SUBMITTAL FOR GRATING AT VEHICLE RAMP
 AND LOADING DOCK

Review Stop B BUILDING (STRUCTURAL)
Rev No 98 Status P Date 2006-06-25 Cont ID  
Sent By rbrown Date 2006-06-25 Time 13:12 Rev Time 0.00
Received By rbrown Date 2006-06-25 Time 13:12 Sent To  
Notes
2006-06-25 00:00:00SUBMITTAL FOR POOL/SPA REINFORCING
 STEEL SHOP DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 97 Status P Date 2006-06-25 Cont ID  
Sent By rbrown Date 2006-06-25 Time 13:05 Rev Time 0.00
Received By rbrown Date 2006-06-25 Time 13:05 Sent To  
Notes
2006-06-25 00:00:00SUBMITTAL FOR WEST COURTYARD FORMWORK
 SHOP DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 96 Status P Date 2006-06-25 Cont ID  
Sent By rbrown Date 2006-06-25 Time 13:01 Rev Time 0.00
Received By rbrown Date 2006-06-25 Time 13:01 Sent To  
Notes
2006-06-25 00:00:00SUBMITTAL FOR POOL/SPA DECK FORMWORK
 SHOP DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 95 Status P Date 2006-06-25 Cont ID  
Sent By rbrown Date 2006-06-25 Time 12:57 Rev Time 0.00
Received By rbrown Date 2006-06-25 Time 12:56 Sent To  
Notes
2006-06-25 00:00:00SUBMITTAL FOR EXTERIOR METAL STUD
 FRAMING SPECS

Review Stop B BUILDING (STRUCTURAL)
Rev No 94 Status P Date 2006-06-25 Cont ID  
Sent By rbrown Date 2006-06-25 Time 12:50 Rev Time 0.00
Received By rbrown Date 2006-06-25 Time 12:49 Sent To  
Notes
2006-06-25 00:00:00STRUCTURAL SUBMITTAL FOR CHM REPORT ON
 DESIGN LOADS AT TIE CLOUMNS

Review Stop B BUILDING (STRUCTURAL)
Rev No 93 Status P Date 2006-04-14 Cont ID  
Sent By rbrown Date 2006-04-14 Time 18:50 Rev Time 0.00
Received By ssarley Date 2006-05-11 Time 11:36 Sent To  
Notes
2006-04-14 00:00:00ARCHITECTURAL SUBMITTAL ON 4/6/06 FOR
 STORAGE UNIT LOCKER DETAILS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 92 Status F Date 2006-04-06 Cont ID  
Sent By rbrown Date 2006-04-06 Time 11:57 Rev Time 0.00
Received By rbrown Date 2006-04-06 Time 11:57 Sent To  
Notes
2006-04-06 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6652
 E-MAIL: [email protected]
  
 NO OBJECTION TO PROPOSED TRANSFER DUCT
 AND FIRE DAMPER SOLUTION.MUST BE
 SUBMITTED FORMALLY AS A SIGNED AND
 SEALED REVISION.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 91 Status F Date 2006-03-11 Cont ID  
Sent By rbrown Date 2006-03-11 Time 23:13 Rev Time 0.00
Received By rbrown Date 2006-03-11 Time 23:13 Sent To  
Notes
2006-03-11 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6652
 E-MAIL: [email protected]
  
 ARCHITECTURAL REVISION SUBMITTED
 11/16/05.
  
 ALL ARCHITECTURAL SHEETS O.K. EXCEPT
 SHEETS A.04 AND A.11 TO A.15.SEE
 COMMENTS BELOW:
  
 1) SHEETS A.04 AND A.11 TO A.15 SHOW
 CHANGED SETBACK DIMENSIONS BETWEEN THE
 BUILDING AND THE PROPERTY LINE.IT WILL
 BE NECESSARY TO SUBMIT A REVISED SITE
 PLAN (SHEET A.01) FOR REVIEW BY PLANNING
 AND ZONING BEFORE SHEETS A.04 AND A.11
 TO A.15 CAN BE PASSED.ALL THREE SETS
 OF THESE SHEETS ARE BEING RETURNED,
 UNSTAMPED.
  
 2) FBC 1007.5SHEETS A-04 AND A.11.
 HANDRAILS ARE REQUIRED ON EACH SIDE OF
 THE STAIRWAY NOW SHOWN IN THE EXIT
 PASSAGEWAY LEADING FROM STAIR #3 TO
 FERN ST.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6652ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 90 Status P Date 2006-03-11 Cont ID  
Sent By rbrown Date 2006-03-11 Time 23:11 Rev Time 0.00
Received By rbrown Date 2006-03-11 Time 23:11 Sent To  
Notes
2006-03-11 00:00:00ARCHITECTURAL REVISION SUBMITTED 9/12/05
 FOR SHEETS A.21, A.21A, A.22, A.23, A.24
 AND A.24A

Review Stop B BUILDING (STRUCTURAL)
Rev No 89 Status F Date 2006-02-17 Cont ID  
Sent By rbrown Date 2006-02-17 Time 18:39 Rev Time 0.00
Received By rbrown Date 2006-02-17 Time 18:39 Sent To  
Notes
2006-02-17 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6652
 E-MAIL: [email protected]
  
 SUBMITTAL ON 2/1/06 FOR ROOFTOP CHAIN
 LINK FENCING.
  
 1) PLEASE ADDRESS THE ZONING PLAN
 REVIEWER'S COMMENT AND RESUBMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 88 Status P Date 2005-08-26 Cont ID  
Sent By rbrown Date 2005-08-26 Time 12:22 Rev Time 0.00
Received By rbrown Date 2005-08-26 Time 12:22 Sent To  
Notes
2005-08-26 00:00:00REVISION SUBMITTED 7/26/05 INCLUDING
 LANDSCAPE PLANS AND SHEETS A.41, A.42
 AND A.42A

Review Stop B BUILDING (STRUCTURAL)
Rev No 87 Status P Date 2005-08-22 Cont ID  
Sent By rbrown Date 2005-08-22 Time 08:49 Rev Time 0.00
Received By rbrown Date 2005-08-22 Time 08:49 Sent To  
Notes
2005-08-22 00:00:00STRUCTURAL SUBMITTAL ON 8/17/05 FOR
 SKYLINE STEEL GRATING SUPPORT SHOP
 DRAWING

Review Stop B BUILDING (STRUCTURAL)
Rev No 86 Status P Date 2005-08-19 Cont ID  
Sent By rbrown Date 2005-08-19 Time 18:25 Rev Time 0.00
Received By rbrown Date 2005-08-19 Time 09:08 Sent To  
Notes
2005-08-19 00:00:00REVISION SUBMITTED ON 7/18/05.
  
 NOTE:
  
 1) THE REVISED SHEET A.06 (3RD FLOOR
 PLAN) NOW SHOWS A LAYOUT FOR THE UNIT
 'C' DEN THAT IS DIFFERENT TO THAT SHOWN
 ON SHEET A-19
  
 2) THE REVISED SHEET A.06 (3RD FLOOR
 PLAN) SHOULD REFER TO SHEET A.16.1 (3RD
 FLOOR PARTIAL PLAN 'F') INSTEAD OF SHEET
 A.16 (TYPICAL FLOOR PARTIAL PLAN 'F')

Review Stop B BUILDING (STRUCTURAL)
Rev No 85 Status P Date 2005-08-09 Cont ID  
Sent By rbrown Date 2005-08-09 Time 14:45 Rev Time 0.00
Received By rbrown Date 2005-08-09 Time 14:45 Sent To  
Notes
2005-08-09 00:00:00SUBMITTAL ON 8/3/05 FOR 3M FIRE BARRIER
 WATER TIGHT SEALANT MATERIAL SPEC.

Review Stop B BUILDING (STRUCTURAL)
Rev No 84 Status P Date 2005-08-09 Cont ID  
Sent By rbrown Date 2005-08-09 Time 14:44 Rev Time 0.00
Received By rbrown Date 2005-08-09 Time 14:44 Sent To  
Notes
2005-08-09 00:00:00SUBMITTAL ON 7/18/05 FOR LATITE ROOFING
 -LIGHTWEIGHT INSULATING CONCRETE
 LETTER AND DOCS

Review Stop B BUILDING (STRUCTURAL)
Rev No 83 Status P Date 2005-08-09 Cont ID  
Sent By rbrown Date 2005-08-09 Time 14:02 Rev Time 0.00
Received By rbrown Date 2005-08-09 Time 14:01 Sent To  
Notes
2005-08-09 00:00:00SUBMITTAL ON 7/18/05 FOR LIGHTWEIGHT
 INSULATING CONCRETE ROOF SHOP DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 82 Status P Date 2005-07-27 Cont ID  
Sent By rbrown Date 2005-07-27 Time 14:05 Rev Time 0.00
Received By rbrown Date 2005-07-27 Time 12:44 Sent To  
Notes
2005-07-27 00:00:00STRUCTURAL SUBMITTAL ON 7/7/05 FOR UPPER
 ROOF LEVEL SHORING AND RE-SHORING SHOP
 DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 81 Status P Date 2005-07-27 Cont ID  
Sent By rbrown Date 2005-07-27 Time 12:34 Rev Time 0.00
Received By rbrown Date 2005-07-27 Time 12:34 Sent To  
Notes
2005-07-27 00:00:00STRUCTURAL SUBMITTAL ON 7/7/05 FOR
 GULFSTREAM GROUND FLOOR PLANTER WALL AND
 SLAB REINFORCEMENT SHOP DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 80 Status P Date 2005-07-27 Cont ID  
Sent By rbrown Date 2005-07-27 Time 11:37 Rev Time 0.00
Received By rbrown Date 2005-07-27 Time 11:37 Sent To  
Notes
2005-07-27 00:00:00STRUCTURAL SUBMITTAL ON 7/7/05 FOR
 GULFSTREAM PLANTER WALL AND ROOF SLAB
 REINFORCEMENT SHOP DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 79 Status P Date 2005-07-27 Cont ID  
Sent By rbrown Date 2005-07-27 Time 11:15 Rev Time 0.00
Received By rbrown Date 2005-07-27 Time 11:15 Sent To  
Notes
2005-07-27 00:00:00FURTHER SUBMITTAL ON 7/7/05 FOR B.C.
 INDUSTRIES (ERIC C. VANHORN, P.E.) SHIM
 SPACE AND FASTENER ANALYSIS FOR SUN
 METAL WINDOWS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 78 Status P Date 2005-07-27 Cont ID  
Sent By rbrown Date 2005-07-27 Time 10:40 Rev Time 0.00
Received By rbrown Date 2005-07-27 Time 10:40 Sent To  
Notes
2005-07-27 00:00:00SUBMITTAL ON 6/29/05 FOR B.C. INDUSTRIES
 (ERIC C. VANHORN, P.E.) SHIM SPACE AND
 FASTENER ANALYSIS FOR SUN METAL WINDOWS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 77 Status P Date 2005-07-27 Cont ID  
Sent By rbrown Date 2005-07-27 Time 10:27 Rev Time 0.00
Received By rbrown Date 2005-07-27 Time 10:27 Sent To  
Notes
2005-07-27 00:00:00STRUCTURAL SUBMITTAL ON 7/27/05 FOR CECO
 CONCRETE CONSTRUCTION LLC UPPER ROOF
 LEVEL FORMWORK SHOP DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 76 Status P Date 2005-07-27 Cont ID  
Sent By rbrown Date 2005-07-27 Time 10:23 Rev Time 0.00
Received By rbrown Date 2005-07-27 Time 10:23 Sent To  
Notes
2005-07-27 00:00:00STRUCTURAL SUBMITTAL ON 6/28/05 FOR CECO
 CONCRETE CONSTRUCTION LLC BUCKHOIST
 RE-SHORING PLANS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 75 Status P Date 2005-07-27 Cont ID  
Sent By rbrown Date 2005-07-27 Time 09:07 Rev Time 0.00
Received By rbrown Date 2005-07-27 Time 09:07 Sent To  
Notes
2005-07-27 00:00:00ARCHITECTURAL SUBMITTAL ON 6/28/05 FOR
 DRYWALL FRAMING, CAULKING, BACKING AND
 FIRE-TREATED WOOD.

Review Stop B BUILDING (STRUCTURAL)
Rev No 74 Status P Date 2005-07-26 Cont ID  
Sent By rbrown Date 2005-07-26 Time 14:44 Rev Time 0.00
Received By rbrown Date 2005-07-26 Time 14:43 Sent To  
Notes
2005-07-26 00:00:00STRUCTURAL SUBMITTAL ON 6/17/05 FOR
 PTE STRAND 8TH FLOOR POST-TENSION CABLE
 SHOP DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 73 Status P Date 2005-06-16 Cont ID  
Sent By rbrown Date 2005-06-16 Time 16:40 Rev Time 0.00
Received By rbrown Date 2005-06-16 Time 16:40 Sent To  
Notes
2005-06-16 00:00:00ARCHITECTURAL/STRUCTURAL REVISION (PART
 OF 145 SHEET B,M,E & P REVISION)
 SUBMITTED ON 4/6/05

Review Stop B BUILDING (STRUCTURAL)
Rev No 72 Status P Date 2005-06-15 Cont ID  
Sent By rbrown Date 2005-06-15 Time 14:09 Rev Time 0.00
Received By rbrown Date 2005-06-15 Time 14:09 Sent To  
Notes
2005-06-15 00:00:00STRUCTURAL SUBMITTAL ON 6/7/05 FOR
 GULFSTREAM ROOF SLAB REINFORCEMENT SHOP
 DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 71 Status P Date 2005-06-15 Cont ID  
Sent By rbrown Date 2005-06-15 Time 14:05 Rev Time 0.00
Received By rbrown Date 2005-06-15 Time 14:05 Sent To  
Notes
2005-06-15 00:00:00STRUCTURAL SUBMITTAL ON 6/7/05 FOR CECO
 ROOF LEVEL SHORING AND RE-SHORING SHOP
 DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 70 Status P Date 2005-06-15 Cont ID  
Sent By rbrown Date 2005-06-15 Time 14:02 Rev Time 0.00
Received By rbrown Date 2005-06-15 Time 14:02 Sent To  
Notes
2005-06-15 00:00:00STRUCTURAL SUBMITTAL ON 6/7/05 FOR POUR
 3, ROOF LEVEL SHORING INSPECTION
 LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 69 Status P Date 2005-06-15 Cont ID  
Sent By rbrown Date 2005-06-15 Time 14:00 Rev Time 0.00
Received By rbrown Date 2005-06-15 Time 13:57 Sent To  
Notes
2005-06-15 00:00:00STRUCTURAL SUBMITTAL ON 5/27/05 FOR POUR
 2, ROOF LEVEL SHORING INSPECTION
 LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 68 Status P Date 2005-06-15 Cont ID  
Sent By rbrown Date 2005-06-15 Time 13:51 Rev Time 0.00
Received By rbrown Date 2005-06-15 Time 13:51 Sent To  
Notes
2005-06-15 00:00:00STRUCTURAL SUBMITTAL ON 5/20/05 FOR POUR
 1, ROOF LEVEL SHORING INSPECTION
 LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 67 Status P Date 2005-06-15 Cont ID  
Sent By rbrown Date 2005-06-15 Time 13:43 Rev Time 0.00
Received By rbrown Date 2005-06-15 Time 13:43 Sent To  
Notes
2005-06-15 00:00:00STRUCTURAL SUBMITTAL ON 5/17/05 FOR
 GULFSTREAM ROOF SLAB REINFORCEMENT SHOP
 DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 66 Status P Date 2005-06-15 Cont ID  
Sent By rbrown Date 2005-06-15 Time 13:39 Rev Time 0.00
Received By rbrown Date 2005-06-15 Time 13:39 Sent To  
Notes
2005-06-15 00:00:00STRUCTURAL SUBMITTAL ON 5/14/05 FOR POUR
 3, 8TH LEVEL SHORING INSPECTION LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 65 Status P Date 2005-06-15 Cont ID  
Sent By rbrown Date 2005-06-15 Time 13:30 Rev Time 0.00
Received By rbrown Date 2005-06-15 Time 13:30 Sent To  
Notes
2005-06-15 00:00:00STRUCTURAL SUBMITTAL ON 5/17/05 FOR 8TH
 LEVEL CECO FORMWORK SHOP DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 64 Status P Date 2005-06-15 Cont ID  
Sent By rbrown Date 2005-06-15 Time 10:42 Rev Time 0.00
Received By rbrown Date 2005-06-15 Time 10:42 Sent To  
Notes
2005-06-15 00:00:00STRUCTURAL SUBMITTAL ON 5/11/05 FOR POUR
 2, 8TH LEVEL SHORING INSPECTION LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 63 Status P Date 2005-06-09 Cont ID  
Sent By rbrown Date 2005-06-09 Time 20:17 Rev Time 0.00
Received By rbrown Date 2005-06-09 Time 20:17 Sent To  
Notes
2005-06-09 00:00:00STRUCTURAL SUBMITTAL ON 5/5/05 FOR
 PTE STRAND 8TH FLOOR POST-TENSION CABLE
 SHOP DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 62 Status P Date 2005-06-09 Cont ID  
Sent By rbrown Date 2005-06-09 Time 20:10 Rev Time 0.00
Received By rbrown Date 2005-06-09 Time 20:10 Sent To  
Notes
2005-06-09 00:00:00STRUCTURAL SUBMITTAL ON 5/5/05 FOR 8TH
 LEVEL SHORING AND RE-SHORING SHOP
 DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 61 Status P Date 2005-06-09 Cont ID  
Sent By rbrown Date 2005-06-09 Time 20:07 Rev Time 0.00
Received By rbrown Date 2005-06-09 Time 20:07 Sent To  
Notes
2005-06-09 00:00:00STRUCTURAL SUBMITTAL ON 5/5/05 FOR
 GULFSTREAM 2ND TO 6TH FLOOR TIE COLUMN
 AND MASONRY STEEL REINFORCEMENT SHOP
 DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 60 Status P Date 2005-06-09 Cont ID  
Sent By rbrown Date 2005-06-09 Time 20:03 Rev Time 0.00
Received By rbrown Date 2005-06-09 Time 20:03 Sent To  
Notes
2005-06-09 00:00:00STRUCTURAL SUBMITTAL ON 5/5/05 FOR
 POUR #1, 8TH LEVEL SHORING INSPECTION
 LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 59 Status P Date 2005-05-06 Cont ID  
Sent By rbrown Date 2005-05-06 Time 13:05 Rev Time 0.00
Received By rbrown Date 2005-05-06 Time 13:04 Sent To  
Notes
2005-05-06 00:00:00STRUCTURAL SUBMITTAL ON 4/27/05 FOR POUR
 3, 7TH LEVEL SHORING INSPECTION LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 58 Status P Date 2005-05-06 Cont ID  
Sent By rbrown Date 2005-05-06 Time 13:04 Rev Time 0.00
Received By rbrown Date 2005-05-06 Time 12:41 Sent To  
Notes
2005-05-06 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 STRUCTURAL SUBMITTAL ON 4/27/05 FOR
 GULFSTREAM 1ST FLOOR MASONRY AND TIE
 COLUMN REINFORCEMENT SHOP DRAWINGS
  
 --PROVISO--
 COMPLY WITH ENGIEER OF RECORD COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 57 Status P Date 2005-05-06 Cont ID  
Sent By rbrown Date 2005-05-06 Time 12:36 Rev Time 0.00
Received By rbrown Date 2005-05-06 Time 12:36 Sent To  
Notes
2005-05-06 00:00:00STRUCTURAL SUBMITTAL ON 4/27/05 FOR
 GULF STREAM 8TH FLOOR REINFORCEMENT SHOP
 DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 56 Status P Date 2005-05-06 Cont ID  
Sent By rbrown Date 2005-05-06 Time 12:19 Rev Time 0.00
Received By rbrown Date 2005-05-06 Time 12:19 Sent To  
Notes
2005-05-06 00:00:00STRUCTURAL SUBMITTAL ON 4/27/05 FOR POUR
 2, 7TH LEVEL SHORING INSPECTION LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 55 Status P Date 2005-05-06 Cont ID  
Sent By rbrown Date 2005-05-06 Time 12:15 Rev Time 0.00
Received By rbrown Date 2005-05-06 Time 12:13 Sent To  
Notes
2005-05-06 00:00:00STRUCTURAL SUBMITTAL ON 4/27/05 FOR
 GROUND LEVEL RAMP TO PARKING LEVEL
 SHORING INSPECTION LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 54 Status P Date 2005-05-06 Cont ID  
Sent By rbrown Date 2005-05-06 Time 11:30 Rev Time 0.00
Received By rbrown Date 2005-05-06 Time 11:30 Sent To  
Notes
2005-05-06 00:00:00STRUCTURAL SUBMITTAL ON 4/26/05 FOR
 CECO CONCRETE CONSTRUCTION 3RD TO 7TH
 FLOOR SHORING SHOP DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 53 Status P Date 2005-05-06 Cont ID  
Sent By rbrown Date 2005-05-06 Time 11:29 Rev Time 0.00
Received By rbrown Date 2005-05-06 Time 11:00 Sent To  
Notes
2005-05-06 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 STRUCTURAL SUBMITTAL ON 4/26/05 FOR
 PTE STRAND 3RD TO 7TH FLOOR BANDED AND
 UNIFORM TENDON SHOP DRAWINGS.
  
 --PROVISO--
 COMPLY WITH ENGINEER OF RECORD COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 52 Status P Date 2005-04-27 Cont ID  
Sent By rbrown Date 2005-04-27 Time 18:10 Rev Time 0.00
Received By rbrown Date 2005-04-27 Time 18:10 Sent To  
Notes
2005-04-27 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 STRUCTURAL SUBMITTAL ON 4/12/05 FOR
 PTE STRAND 2ND TO 7TH FLOOR POST-TENSION
 CABLE SHOP DRAWINGS.
  
 --PROVISO--
 COMPLY WITH ENGIEER OF RECORD COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 51 Status P Date 2005-04-08 Cont ID  
Sent By rbrown Date 2005-04-08 Time 10:18 Rev Time 0.00
Received By rbrown Date 2005-04-08 Time 10:18 Sent To  
Notes
2005-04-08 00:00:00STRUCTURAL SUBMITTAL ON 3/31/05 FOR POUR
 1, 5TH LEVEL SHORING INSPECTION LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 50 Status P Date 2005-03-30 Cont ID  
Sent By rbrown Date 2005-03-30 Time 14:39 Rev Time 0.00
Received By rbrown Date 2005-03-30 Time 14:38 Sent To  
Notes
2005-03-30 00:00:00STRUCTURAL SUBMITTAL ON 3/4/05 FOR POUR
 1, 3RD LEVEL SHORING INSPECTION LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 49 Status P Date 2005-03-30 Cont ID  
Sent By rbrown Date 2005-03-30 Time 14:34 Rev Time 0.00
Received By rbrown Date 2005-03-30 Time 14:34 Sent To  
Notes
2005-03-30 00:00:00STRUCTURAL SUBMITTAL ON 3/4/05 FOR POUR
 3, 2ND LEVEL SHORING INSPECTION LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 48 Status P Date 2005-03-30 Cont ID  
Sent By rbrown Date 2005-03-30 Time 12:18 Rev Time 0.00
Received By rbrown Date 2005-03-30 Time 12:17 Sent To  
Notes
2005-03-30 00:00:00STRUCTURAL SUBMITTAL ON 3/24/05 FOR
 SKYLINE STEEL FABRICATORS, 1ST FLOOR AND
 POOL DECK, STEEL DECKING SHOP DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 47 Status P Date 2005-03-30 Cont ID  
Sent By rbrown Date 2005-03-30 Time 12:06 Rev Time 0.00
Received By rbrown Date 2005-03-30 Time 12:06 Sent To  
Notes
2005-03-30 00:00:00STRUCTURAL SUBMITTAL ON 3/21/05 FOR POUR
 1, 4TH LEVEL SHORING INSPECTION LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 46 Status P Date 2005-03-30 Cont ID  
Sent By rbrown Date 2005-03-30 Time 11:21 Rev Time 0.00
Received By rbrown Date 2005-03-30 Time 11:18 Sent To  
Notes
2005-03-30 00:00:00STRUCTURAL SUBMITTAL ON 3/16/05 FOR POUR
 3, 3RD LEVEL SHORING INSPECTION LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 45 Status F Date 2005-03-29 Cont ID  
Sent By rbrown Date 2005-03-29 Time 17:40 Rev Time 0.00
Received By rbrown Date 2005-03-29 Time 16:20 Sent To  
Notes
2005-03-29 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 STRUCTURAL SUBMITTAL ON 3/10/05 FOR
 SHARON STAIRS 'DROP-IN' STAIR SYSTEM
 SHOP DRAWINGS.
  
 1) THIS IS A STRUCTURAL SUBMITTAL AND
 NOTE 3 ON SHEETS D10 AND KLP STATES "THE
 ENGINEER OF RECORD SHALL CHECK THE
 ADEQUACY OF THE BUILDING COMPONENTS DUE
 TO........".
 THE ENGINEER OF RECORD SHALL REVIEW AND
 STAMP, OR PROVIDE A SIGNED AND SEALED
 COVER LETTER MAKING SPECIFIC REFERENCE
 TO, THE SUBMITTED STRUCTURAL
 DOCUMENT(S).
  
 2) 61G15-23.002(1)FL. ADMIN. CODE.
 THE SUBMITTED CALCULATION INDEX SHEET
 DOES NOT BEAR THE ORIGINAL SIGNATURE,
 RAISED SEAL OR PRINTED LICENSE NUMBER OF
 STEVEN W.SCHAUB, P.E.
 DOCUMENTS SUBMITTED BY AN ENGINEER FOR
 PUBLIC RECORD SHALL BEAR THE SIGNATURE
 AND SEAL OF THE ENGINEER. (471.025 F.S.)
  
 3) BECAUSE SHARON STAIRS DOES NOT HAVE A
 STATE ENGINEERING BUSINESS (CERTIFICATE
 OF AUTHORIZATION) NUMBER, STEVEN W.
 SCHAUB, P.E. IS THE SOLE RESPONSIBLE
 ENGINEER AND HIS PRINTED NAME, LICENSE
 NUMBER (P.E. #60509) AND ADDRESS (5800
 EAST THOMAS ROAD, STE 104, SCOTTSDALE
 ARIZONA85251) MUST BE INDICATED ON
 EACH SHEET.THIS INFORMATION MAY BE
 HANDWRITTEN OR STAMPED ON THE PLANS IF
 THE ENGINEER DOES NOT INCLUDE IT IN HIS
 TITLE BLOCK.TO EXPEDITE THIS SUBMITTAL
 ONLY, THE CONTRACTOR MAY OPT TO ADD THE
 ENGINEER'S NAME, LICENSE NUMBER AND
 ADDRESS TO EACH SHEET.
  
 NOTE:61G15-23.002(2)FL. ADMIN. CODE.
 PLANS SIGNED & SEALED BY A PROFESSIONAL
 ENGINEER SHALL INCLUDE EITHER THE NAME,
 ADDRESS AND LICENSE NUMBER OF THE
 ENGINEER OR, THE NAME AND LICENSE NUMBER
 OF THE ENGINEER AND THE NAME, ADDRESS
 AND CERTIFICATE OF AUTHORIZATION NUMBER
 OF THE ENGINEERING BUSINESS THROUGH
 WHICH THE ENGINEER IS PRACTICING
 (471.025 F.S. AND 471.023 F.S.).
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 44 Status P Date 2005-03-29 Cont ID  
Sent By rbrown Date 2005-03-29 Time 15:40 Rev Time 0.00
Received By rbrown Date 2005-03-29 Time 15:40 Sent To  
Notes
2005-03-29 00:00:00STRUCTURAL SUBMITTAL ON 3/10/05 FOR
 CECO CONCRETE CONSTRUCTION 2ND TO 7TH
 FLOOR SHORING SHOP DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 43 Status P Date 2005-03-29 Cont ID  
Sent By rbrown Date 2005-03-29 Time 15:36 Rev Time 0.00
Received By rbrown Date 2005-03-29 Time 15:36 Sent To  
Notes
2005-03-29 00:00:00STRUCTURAL SUBMITTAL ON 3/10/05 FOR
 KUREZ DR VOX DISSIPATING CONCRETE CURING
 COMPOUND MANUFACTURER'S DATA.

Review Stop B BUILDING (STRUCTURAL)
Rev No 42 Status P Date 2005-03-23 Cont ID  
Sent By rbrown Date 2005-03-23 Time 17:00 Rev Time 0.00
Received By rbrown Date 2005-03-23 Time 17:00 Sent To  
Notes
2005-03-23 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 STRUCTURAL SUBMITTAL ON 2/24/05 FOR
 PTE STRAND 3RD TO 7TH FLOOR POST-TENSION
 CABLE SHOP DRAWINGS.
  
 --PROVISO--
 COMPLY WITH ENGIEER OF RECORD COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 41 Status P Date 2005-03-23 Cont ID  
Sent By rbrown Date 2005-03-23 Time 16:48 Rev Time 0.00
Received By rbrown Date 2005-03-23 Time 16:48 Sent To  
Notes
2005-03-23 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 STRUCTURAL SUBMITTAL ON 2/24/05 FOR
 GULFSTREAM 3RD TO 7TH FLOOR
 REINFORCEMENT SHOP DRAWINGS
  
 --PROVISO--
 COMPLY WITH ENGIEER OF RECORD COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 40 Status P Date 2005-03-23 Cont ID  
Sent By rbrown Date 2005-03-23 Time 16:19 Rev Time 0.00
Received By rbrown Date 2005-03-23 Time 16:18 Sent To  
Notes
2005-03-23 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 STRUCTURAL SUBMITTAL ON 2/24/05 FOR
 GULFSTREAM 2ND FLOOR REINFORCEMENT SHOP
 DRAWINGS
  
 --PROVISO--
 COMPLY WITH ENGIEER OF RECORD COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 39 Status P Date 2005-03-23 Cont ID  
Sent By rbrown Date 2005-03-23 Time 15:40 Rev Time 0.00
Received By rbrown Date 2005-03-23 Time 15:39 Sent To  
Notes
2005-03-23 00:00:00STRUCTURAL SUBMITTAL ON 2/24/05 FOR POUR
 2, 2ND LEVEL SHORING INSPECTION LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 38 Status P Date 2005-02-18 Cont ID  
Sent By rbrown Date 2005-02-18 Time 10:39 Rev Time 0.00
Received By rbrown Date 2005-02-18 Time 10:39 Sent To  
Notes
2005-02-18 00:00:00STRUCTURAL SUBMITTAL ON 2/17/05 FOR
 POUR 1, 2ND LEVEL SLAB SHORING
 INSPECTION LETTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 37 Status F Date 2005-02-10 Cont ID  
Sent By rbrown Date 2005-02-10 Time 17:46 Rev Time 0.00
Received By rbrown Date 2005-02-10 Time 17:46 Sent To  
Notes
2005-02-10 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 STRUCTURAL SUBMITTAL ON 2/9/05 FOR PTE
 STRAND POST-TENSION SHOP DRAWINGS PT-1,
 02 AND 03 (GENERAL NOTES AND 2ND LEVEL
 PLANS).
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 1) FBC 3502SHEET PT-1, NOTE 2 -
 ANCHORAGES CITES TO OUTDATED
 REFERENCES,
 STANDARD BUILDING CODE AND ACI 318-83.
 THE APPLICABLE CODE IS FLORIDA BUILDING
 CODE 2001 AND THE CODE REFERENCED
 VERSION OF THE STANDARD FOR STRUCTURAL
 CONCRETE IS ACI 318-02.AMEND THE
 NOTES
 TO CITE TO THE CURRENT CODE AND
 STANDARD.
  
 2) 61G15-23.002(2)FL. ADMIN. CODE.
 ALL THREE COPIES OF SHEETS PT-02 AND
 PT-03 ARE PHOTOCOPIED AFTER
 SIGNATURE/SEAL.PLANS SIGNED & SEALED
 BY A PROFESSIONAL ENGINEER FOR PUBLIC
 RECORD SHALL INCLUDE THE ORIGINAL
 SIGNATURE AND SEAL OF THE ENGINEER
 (471.025 F.S.)
  
 3) 61G15-23.002(2)FL. ADMIN. CODE.
 IT
 IS NOTED THAT THE ADDRESS OF PTE STRAND
 CO., INC. IS STATED ON THE PLANS, BUT
 THE FIRM DOES NOT HAVE A CERTIFICATE OF
 AUTHORIZATION NUMBER, ISSUED BY THE
 BOARD OF ENGINEERS, SO THE ADDRESS OF
 MIAN A. HAMID P.E. MUST BE PRINTED ON
 THE PLANS.THIS CAN BE ADDED BY HAND.
 PLANS SIGNED & SEALED BY A PROFESSIONAL
 ENGINEER SHALL INCLUDE EITHER THE NAME,
 ADDRESS AND LICENSE NUMBER OF THE
 ENGINEER OR, THE NAME AND LICENSE
 NUMBER
 OF THE ENGINEER AND THE NAME, ADDRESS
 AND CERTIFICATE OF AUTHORIZATION NUMBER
 OF THE ENGINEERING BUSINESS THROUGH
 WHICH THE ENGINEER IS PRACTICING
 (471.025 F.S. AND 471.023 F.S.).
  
 4) THE ABOVE IS APPLICABLE TO ALL
 STRUCTURAL SHOP DRAWING SUBMITTALS
 REQUIRED TO BE SEALED BY THE
 RESPONSIBLE
 ENGINEER.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL
 INFO
 TELEPHONE: (561) 805 6716ROBERT
 BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 36 Status P Date 2005-02-08 Cont ID  
Sent By rbrown Date 2005-02-08 Time 09:57 Rev Time 0.00
Received By rbrown Date 2005-02-08 Time 09:57 Sent To  
Notes
2005-02-08 00:00:00STRUCTURAL SUBMITTAL ON 2/3/05 FOR CECO
 CONSTRUCTION 2ND THRU 7TH FLOOR SLAB
 FORMWORK DRAWINGS
  
 --PROVISO--
 COMPLY WITH THE ARCHITECT OF RECORD'S
 COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 35 Status P Date 2005-02-08 Cont ID  
Sent By rbrown Date 2005-02-08 Time 09:51 Rev Time 0.00
Received By rbrown Date 2005-02-08 Time 09:51 Sent To  
Notes
2005-02-08 00:00:00ARCHITECTURAL SUBMITTAL ON 2/3/05 FOR
 MANUFACTURER'S DATA ON DRYWALL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 34 Status P Date 2005-02-08 Cont ID  
Sent By rbrown Date 2005-02-08 Time 09:48 Rev Time 0.00
Received By rbrown Date 2005-02-08 Time 09:48 Sent To  
Notes
2005-02-08 00:00:00STRUCTURAL SUBMITTAL ON 2/3/05 FOR CECO
 CONSTRUCTION GROUND FLOOR TRANSFER SLAB
 SHORING DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 33 Status P Date 2005-02-08 Cont ID  
Sent By rbrown Date 2005-02-08 Time 09:40 Rev Time 0.00
Received By rbrown Date 2005-02-08 Time 09:40 Sent To  
Notes
2005-02-08 00:00:00STRUCTURAL SUBMITTAL ON 2/3/05 FOR GULF
 STREAM GROUND FLOOR TOP BAR FOR POURS 3
 & 4, ADDITIONAL TOP BARS AND COLUMN
 DOWELS.
  
 --PROVISO--
 COMPLY WITH THE ENGINEER OF RECORD'S
 COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 32 Status P Date 2005-02-07 Cont ID  
Sent By rbrown Date 2005-02-07 Time 18:28 Rev Time 0.00
Received By rbrown Date 2005-02-07 Time 18:28 Sent To  
Notes
2005-02-07 00:00:00ARCHITECTURAL SUBMITTAL ON 1/28/05 FOR
 COHEN FREEDMAN ENCINOSA AND ASSOCS
 LETTER DATED 1/13/05 RE: 3/4" SLAB
 DEPRESSION

Review Stop B BUILDING (STRUCTURAL)
Rev No 31 Status P Date 2005-02-07 Cont ID  
Sent By rbrown Date 2005-02-07 Time 18:27 Rev Time 0.00
Received By rbrown Date 2005-02-07 Time 18:27 Sent To  
Notes
2005-02-07 00:00:00STRUCTURAL SUBMITTAL ON 1/21/05 FOR
 GULF
 STREAM GROUND FLOOR TRANSFER SLAB SHEAR
 AND OPENING REINFORCEMENT.
  
 --PROVISO--
 COMPLY WITH THE ENGINEER OF RECORD'S
 COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 30 Status P Date 2005-02-07 Cont ID  
Sent By rbrown Date 2005-02-07 Time 18:25 Rev Time 0.00
Received By rbrown Date 2005-02-07 Time 18:25 Sent To  
Notes
2005-02-07 00:00:00STRUCTURAL SUBMITTAL ON 1/21/05 FOR
 GULF
 STREAM GROUND FLOOR TRANSFER SLAB
 BOTTOM
 REINFORCEMENT.
  
 --PROVISO--
 COMPLY WITH THE ENGINEER OF RECORD'S
 COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 29 Status P Date 2005-02-07 Cont ID  
Sent By rbrown Date 2005-02-07 Time 18:23 Rev Time 0.00
Received By rbrown Date 2005-02-07 Time 18:23 Sent To  
Notes
2005-02-07 00:00:00STRUCTURAL SUBMITTAL ON 1/21/05 FOR
 CECO
 CONSTRUCTION GROUND FLOOR TRANSFER SLAB
 FORMWORK DRAWINGS.
  
 --PROVISO--
 COMPLY WITH THE ARCHITECT OF RECORD'S
 COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 28 Status P Date 2005-01-18 Cont ID  
Sent By rbrown Date 2005-01-18 Time 15:09 Rev Time 0.00
Received By rbrown Date 2005-01-18 Time 14:44 Sent To  
Notes
2005-01-18 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 STRUCTURAL SUBMITTAL ON 1/14/05 FOR
 GULF STREAM SHEAR WALL AND COLUMN
 SCHEDULE AND COLUMN PLAN.
  
 --PROVISO--
 COMPLY WITH THE ENGINEER OF RECORD'S
 COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 27 Status P Date 2004-12-21 Cont ID  
Sent By rbrown Date 2004-12-21 Time 09:47 Rev Time 0.00
Received By rbrown Date 2004-12-21 Time 09:47 Sent To  
Notes
2004-12-21 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 STRUCTURAL SUBMITTAL ON 12/20/04 FOR
 CECO CONCRETE CONSTRUCTION SHOP
 DRAWINGS.
  
 --PROVIS0--
 BECAUSE CECO CONCRETE CONSTRUCTION DOES
 NOT HAVE A STATE ENGINEERING BUSINESS
 (CERTIFICATE OF AUTHORIZATION) NUMBER,
 AUBREY L. DUNHAM, P.E. IS THE SOLE
 RESPONSIBLE ENGINEER AND HIS ADDRESS
 MUST BE INDICATED ON EACH SHEET.FOR
 THIS SUBMITTAL ONLY, THE ADDRESS HAS
 BEEN ADDED AS A PROVISO.IF THE
 ENGINEER'S ADDRESS DOES NOT APPEAR ON
 FUTURE SUBMITTALS THEY WILL BE DENIED.
 THIS INFORMATION MAY BE HANDWRITTEN OR
 STAMPED ON THE PLANS IF THE ENGINEER
 DOES NOT INCLUDE IT IN HIS TITLE BLOCK.
  
 NOTE:61G15-23.002(2)FL. ADMIN. CODE.
 PLANS SIGNED & SEALED BY A PROFESSIONAL
 ENGINEER SHALL INCLUDE EITHER THE NAME,
 ADDRESS AND LICENSE NUMBER OF THE
 ENGINEER OR, THE NAME AND LICENSE NUMBER
 OF THE ENGINEER AND THE NAME, ADDRESS
 AND CERTIFICATE OF AUTHORIZATION NUMBER
 OF THE ENGINEERING BUSINESS THROUGH
 WHICH THE ENGINEER IS PRACTICING
 (471.025 F.S. AND 471.023 F.S.).

Review Stop B BUILDING (STRUCTURAL)
Rev No 26 Status P Date 2004-12-17 Cont ID  
Sent By rbrown Date 2004-12-17 Time 17:56 Rev Time 0.00
Received By rbrown Date 2004-12-17 Time 17:56 Sent To  
Notes
2004-12-17 00:00:00STRUCTURAL SUBMITTAL ON 12/13/04 FOR
 GULF STREAM B-1 LEVEL SLAB REINFORCEMENT
 SHOP DRAWING

Review Stop B BUILDING (STRUCTURAL)
Rev No 25 Status P Date 2004-12-17 Cont ID  
Sent By rbrown Date 2004-12-17 Time 17:54 Rev Time 0.00
Received By rbrown Date 2004-12-17 Time 17:54 Sent To  
Notes
2004-12-17 00:00:00STRUCTURAL SUBMITTAL ON 12/13/04 FOR
 FOUNDATION SLAB CONSTRUCTION JOINT
 LOCATIONS

Review Stop B BUILDING (STRUCTURAL)
Rev No 24 Status P Date 2004-12-17 Cont ID  
Sent By rbrown Date 2004-12-17 Time 17:54 Rev Time 0.00
Received By rbrown Date 2004-12-17 Time 17:53 Sent To  
Notes
2004-12-17 00:00:00STRUCTURAL SUBMITTAL ON 12/13/04 FOR
 GALVANIZED REINFORCING STEEL PRODUCT
 DATA

Review Stop B BUILDING (STRUCTURAL)
Rev No 23 Status P Date 2004-12-17 Cont ID  
Sent By rbrown Date 2004-12-17 Time 17:53 Rev Time 0.00
Received By rbrown Date 2004-12-17 Time 17:53 Sent To  
Notes
2004-12-17 00:00:00STRUCTURAL SUBMITTAL ON 12/13/04 FOR
 WELDED WIRE MESH PRODUCT DATA

Review Stop B BUILDING (STRUCTURAL)
Rev No 22 Status P Date 2004-12-17 Cont ID  
Sent By rbrown Date 2004-12-17 Time 17:50 Rev Time 0.00
Received By rbrown Date 2004-12-17 Time 17:50 Sent To  
Notes
2004-12-17 00:00:00STRUCTURAL SUBMITTAL ON 12/13/04 FOR
 GALVANIZED TIE WIRE PRODUCT DATA

Review Stop B BUILDING (STRUCTURAL)
Rev No 21 Status P Date 2004-12-02 Cont ID  
Sent By rbrown Date 2004-12-02 Time 10:37 Rev Time 0.00
Received By rbrown Date 2004-12-02 Time 10:36 Sent To  
Notes
2004-12-02 00:00:00STRUCTURAL REVISION SUBMITTED 11/19/04
 FOR SHEETS S-3, S-19 AND S-21

Review Stop B BUILDING (STRUCTURAL)
Rev No 20 Status P Date 2004-12-01 Cont ID  
Sent By rbrown Date 2004-12-01 Time 12:45 Rev Time 0.00
Received By rbrown Date 2004-12-01 Time 12:45 Sent To  
Notes
2004-12-01 00:00:00STRUCTURAL SUBMITTAL ON 12/1/04 FOR
 CONCRETE WATERSTOP PRODUCT INFO SHEETS

Review Stop B BUILDING (STRUCTURAL)
Rev No 19 Status P Date 2004-11-17 Cont ID  
Sent By rbrown Date 2004-11-17 Time 17:37 Rev Time 0.00
Received By rbrown Date 2004-11-17 Time 17:36 Sent To  
Notes
2004-11-17 00:00:00STRUCTURAL SUBMITTAL ON 11/16/04 FOR
 CECO CONCRETE CONSTRUCTION SHOP
 DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 18 Status P Date 2004-11-17 Cont ID  
Sent By rbrown Date 2004-11-17 Time 17:27 Rev Time 0.00
Received By rbrown Date 2004-11-17 Time 17:27 Sent To  
Notes
2004-11-17 00:00:00STRUCTURAL SUBMITTAL ON 11/16/04 FOR
 URS
 CORPORATION SHEET PILE WALL DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 17 Status P Date 2004-11-17 Cont ID  
Sent By rbrown Date 2004-11-17 Time 17:25 Rev Time 0.00
Received By rbrown Date 2004-11-17 Time 17:27 Sent To  
Notes
2004-11-17 00:00:00STRUCTURAL SUBMITTAL ON 11/16/04 FOR
 ARDAMAN ASSOCIATES LETTER DATED 11/11/04
 RE: 'HJ FOUNDATIONS' VIBROFLOTATION

Review Stop B BUILDING (STRUCTURAL)
Rev No 16 Status P Date 2004-11-17 Cont ID  
Sent By rbrown Date 2004-11-17 Time 17:22 Rev Time 0.00
Received By rbrown Date 2004-11-17 Time 17:22 Sent To  
Notes
2004-11-17 00:00:00STRUCTURAL SUBMITTAL ON 11/16/04 FOR
 ARDAMAN ASSOCIATES LETTER DATED 9/29/04
 RE: 'HJ FOUNDATIONS' VIBROFLOTATION

Review Stop B BUILDING (STRUCTURAL)
Rev No 15 Status P Date 2004-11-17 Cont ID  
Sent By rbrown Date 2004-11-17 Time 17:21 Rev Time 0.00
Received By rbrown Date 2004-11-17 Time 17:21 Sent To  
Notes
2004-11-17 00:00:00STRUCTURAL SUBMITTAL ON 11/16/04 FOR
 HILTI ANCHOR SPEC

Review Stop B BUILDING (STRUCTURAL)
Rev No 14 Status P Date 2004-11-17 Cont ID  
Sent By rbrown Date 2004-11-17 Time 17:18 Rev Time 0.00
Received By rbrown Date 2004-11-17 Time 17:18 Sent To  
Notes
2004-11-17 00:00:00STRUCTURAL SUBMITTAL ON 11/16/04 FOR
 CONCRETE REPAIR MORTAR SPEC

Review Stop B BUILDING (STRUCTURAL)
Rev No 13 Status P Date 2004-11-10 Cont ID  
Sent By rbrown Date 2004-11-10 Time 17:05 Rev Time 0.00
Received By rbrown Date 2004-11-10 Time 10:12 Sent To  
Notes
2004-11-10 00:00:00STRUCTURAL SUBMITTAL ON 11/2/04 FOR
 FOOTING AND PARKING LEVEL SLAB, WALL AND
 COLUMN REINFORCEMENT CUT SHEETS

Review Stop B BUILDING (STRUCTURAL)
Rev No 12 Status P Date 2004-11-10 Cont ID  
Sent By rbrown Date 2004-11-10 Time 17:02 Rev Time 0.00
Received By rbrown Date 2004-11-10 Time 17:02 Sent To  
Notes
2004-11-10 00:00:00STRUCTURAL SUBMITTAL ON 11/2/04 FOR
 CONCRETE MIX DESIGNS

Review Stop B BUILDING (STRUCTURAL)
Rev No 11 Status P Date 2004-11-10 Cont ID  
Sent By rbrown Date 2004-11-10 Time 16:59 Rev Time 0.00
Received By rbrown Date 2004-11-10 Time 16:59 Sent To  
Notes
2004-11-10 00:00:00STRUCTURAL SUBMITTAL ON 11/2/04 FOR SLAB
 CONSTRUCTION JOINT LOCATIONS

Review Stop B BUILDING (STRUCTURAL)
Rev No 10 Status P Date 2004-11-10 Cont ID  
Sent By rbrown Date 2004-11-10 Time 16:57 Rev Time 0.00
Received By rbrown Date 2004-11-10 Time 16:57 Sent To  
Notes
2004-11-10 00:00:00STRUCTURAL SUBMITTAL ON 11/2/04 FOR WALL
 WATERPROOFING BENTONITE PRODUCT INFO
 SHEETS

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status P Date 2004-11-10 Cont ID  
Sent By rbrown Date 2004-11-10 Time 16:49 Rev Time 0.00
Received By rbrown Date 2004-11-10 Time 16:49 Sent To  
Notes
2004-11-10 00:00:00STRUCTURAL SUBMITTAL ON 11/2/04 FOR WALL
 WATERPROOFING PRODUCT INFO SHEETS

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2004-10-08 Cont ID  
Sent By rbrown Date 2004-10-08 Time 15:36 Rev Time 0.00
Received By rbrown Date 2004-10-08 Time 15:35 Sent To  
Notes
2004-10-08 00:00:00STRUCTURAL REVISION SUBMITTED ON 9/30/04
 FOR CHM PLANS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2004-09-17 Cont ID  
Sent By csiegber Date 2004-10-05 Time 11:10 Rev Time 0.00
Received By rbrown Date 2004-09-17 Time 16:58 Sent To  
Notes
2004-09-17 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 STRUCTURAL SUBMITTAL ON 8/26/04 FOR
 SHEETPILE RETAINING WALL.
  
 --PROVISO--
 STRUCTURAL DRG/CALC SUBMITTALS SHALL BE
 REVIEWED AND STAMPED BY THE ENGINEER OF
 RECORD (CHM, MIAMI FL).

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2004-06-25 Cont ID  
Sent By csiegber Date 2004-08-26 Time 10:27 Rev Time 0.00
Received By rbrown Date 2004-06-25 Time 13:59 Sent To  
Notes
2004-06-25 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 NOTE:
 THREE COPIES OF ACHITECTURAL SHEETS
 A.02, A.03, A.35 AND LS.5 WERE AMENDED,
 SIGNED AND DATED BY GUILLERMO ENCINOSA
 (ARCHITECT OF RECORD) HY HAND ON 6/23/04
  
 --PROVISO--
 SUBMIT METAL LOUVERED DOOR PRODUCT
 APPROVALS FOR DOORS WITH DESIGN PRESSURE
 RATINGS OF AT LEAST +70 PSF AND -80 PSF.
 SHEET A.48, DOOR SCHEDULE, SHOWS
 LOUVERED DOORS (TYPE H AND G) FOR DOORS
 43, 93 AND 94 (TO THE GENERATOR, BOILER
 AND PUMP ROOMS).THE SUBMITTED CURRIES
 COMPANY PRODUCT APPROVAL NOA# 03-0319.04
 HAS A MAXIMUM DESIGN PRESSURE RATING OF
 ONLY +50 PSF AND -50 PSF.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2004-06-23 Cont ID  
Sent By rbrown Date 2004-06-23 Time 17:56 Rev Time 0.00
Received By rbrown Date 2004-06-23 Time 17:56 Sent To Z
Notes
2004-06-23 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 NOTE:
 THREE COPIES OF ARCHITECTURAL SHEETS
 A.02, A.03, A.35AND LS.5 WERE AMENDED,
 SIGNED AND DATED BY GUILLERMO ENCINOSA
 (ARCHITECT OF RECORD) BY HAND ON 6/23/04
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 4/16/04:
  
 1) THE COMMENT RESPONSE, DATED 5/8/04,
 IS NOTED.
 THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY COURTHOUSE
 AND A COPY SUBMITTED TO THIS OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2) THE COMMENT RESPONSE, DATED 5/8/04,
 IS NOTED.
 IMPACT FEES. THE PLANS SHALL BE TAKEN
 TO PALM BEACH COUNTY BUILDING DEPARTMENT
 FOR IMPACT FEE ASSESSMENT. THEY SHALL BE
 STAMPED AT THAT OFFICE AND A COPY OF THE
 PAID RECEIPT SUBMITTED TO THE CITY OF
 WEST PALM BEACH DEPT OF CONSTRUCTION
 SERVICES BEFORE A PERMIT CAN BE ISSUED.
  
 4) DECLARATION OF CONDOMINIUM BEFORE
 C.O. ISSUE.THE COMMENT RESPONSE, DATED
 5/8/04 IS NOTED.
  
 6) FBC* 105.13.1SPECIAL INSPECTOR.
 THIS COMMENT HAS NOT BEEN ADDRESSED. THE
 'SPECIAL INSPECTOR AGREEMENT' WAS NOT
 RE-SUBMITTED.REPEATING THE COMMENTS
 FROM THE PREVIOUS REVIEW, THE SUBMITTED
 'SPECIAL INSPECTOR AGREEMENT' IS MISSING
 THE LAST PAGE, WHICH IS TO BE SIGNED BY
 THE CONTRACTOR AND ARCHITECT/ENGINEER
 THE AGREEMENT SHALL ALSO BE SIGNEED BY T
 HE OWNER AND JOB INSPECTOR IN THE SPACE
 ALLOCATED.ALL SIGNATURES ARE TO BE
 NOTARIZED ORIGINALS.
  
 7) SEPARATE SWIMMING POOL PERMIT APPLIC.
 THE COMMENT RESPONSE, DATED 5/8/04, IS
 NOTED.
  
 9) FBC 13-103.1.2ENERGY CODE
 COMPLIANCE FORMS.THE COMMENT RESPONSE
 DATED 5/8/04, IS NOTED BUT SHEET 2 OF
 THE SUBMITTED ENERGY CODE COMPLIANCE
 FORMS SHALL BE SIGNED BY A KENCO
 COMMUNITIES REPRESENTATIVE AS 'OWNER',
 TO CERTIFY COMPLIANCE.
  
 11) PRODUCT APPROVALS.THIS COMMENT HAS
 NOT BEEN PROPERLY ADDRESSED.
 NO PRODUCT APPROVALS HAVE BEEN SUBMITTED
 FOR THE ROOFING PRODUCTS, STOREFRONT AND
 HOLLOW METAL, LOUVERED, FLUSH (SINGLE
 AND DOUBLE AND ALUMINUM GLAZED SWING
 (SINGLE AND DOUBLE) EXTERIOR DOORS.
  
 50) SHEET A.29PRE-CAST CONCRETE
 ARCHITECTURAL FEATURES/MOLDINGS.ONE
 OF THE THREE SETS OF PLANS STILL HAS
 THE 'OLD' REVISION OF SHEET A.29. INSERT
 THE LATEST REVISION AND REMOVE THE 'OLD'
 SHEET.
  
 52) FBC 412.5(3)SHEET M4.01, SMOKE
 CONTROL NOTE C.THIS COMMENT HAS NOT
 BEEN PROPERLY ADDRESSED.THE REVISION
 MADE IS NOTED BUT THE NOTE C STILL DOES
 NOT MAKE SENSE AND DOES NOT CLEARLY
 EXPRESS THE ENGINEER'S INTENT.PLEASE
 READ THE NOTE AND CONSIDER THAT IT MAY
 BE CLARIFIED BY:
 - DELETING THE WORDS "..THROUGH THE..."
 FROM THE SECOND SENTENCE.
 - REPLACING THE WORDS "TO CLOSE AND..."
 WITH "IT SHALL ALSO..." AT THE BEGINNING
 OF THE LAST SENTENCE.
  
 53) FBC 1005.6.9.9SHEET M4.01, SMOKE
 CONTROL NOTE 3B - STAIR BAROMETRIC
 RELIEF.THIS COMMENT HAS NOT BEEN
 PROPERLY ADDRESSED. THE REVISION MADE IS
 NOTED BUT THE NOTE SPECIFIES A MINIMUM
 PRESSURE DIFFERENCE OF 0.35"WG WHILE
 FBC 1005.6.9.9 REQUIRES A PRESSURE
 DIFFERENCE OF 0.05"WG MINIMUM AND
 0.35"WG MAXIMUM.AMEND THE NOTE TO
 DEMONSTRATE COMPLIANCE.
  
 54) TO EXPEDITE REVIEW OF A RESUBMITTAL
 WHICH REQUIRES NEW PLANS IN ORDER TO
 ADDRESS THE ABOVE COMMENTS, THE OLD
 SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHOULD BE STAPLED/CLIPPED TO THE
 REMAINING OLD SHEETS FOR COMPARISON OF
 REVISIONS WHEN REVIEWING THE RESUBMITTED
 PLANS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2004-04-16 Cont ID  
Sent By rbrown Date 2004-04-16 Time 16:50 Rev Time 0.00
Received By rbrown Date 2004-04-14 Time 10:44 Sent To  
Notes
2004-04-14 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 NOTE:
 CHAPTER 553.80(2)(B) FLORIDA STATUTES
 STATES THAT A LOCAL GOVERNMENT SHALL
 IMPOSE A FEE OF FOUR TIMES THE FEE FOR
 PLAN REVIEW, IF PLANS ARE REJECTED THREE
 OR MORE TIMES FOR REPEATED FAILURE TO
 CORRECT A CODE VIOLATION.
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 11/21/03:
  
 1) THE COMMENT RESPONSE, DATED 2/11/04,
 IS NOTED.
 THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY COURTHOUSE
 AND A COPY SUBMITTED TO THIS OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2) THE COMMENT RESPONSE, DATED 2/11/04,
 IS NOTED.
 IMPACT FEES. THE PLANS SHALL BE TAKEN
 TO PALM BEACH COUNTY BUILDING DEPARTMENT
 FOR IMPACT FEE ASSESSMENT. THEY SHALL BE
 STAMPED AT THAT OFFICE AND A COPY OF THE
 PAID RECEIPT SUBMITTED TO THE CITY OF
 WEST PALM BEACH DEPT OF CONSTRUCTION
 SERVICES BEFORE A PERMIT CAN BE ISSUED.
  
 3) UNITY OF TITLE. THE COMMENT RESPONSE,
 DATED 2/11/04, IS NOTED BUT THE COMMENT
 HAS NOT BEEN PROPERLY ADDRESSED.PALM
 BEACH COUNTY PROPERTY APPRAISERS OFFICE
 (HTTP://WWW.CO.PALM-BEACH.FL.US/PAPA/)
 SHOWS THE PROPOSED BUILDING STRUCTURE
 TRANSGRESSES LEGAL BOUNDARY LINES
 BETWEEN THREE LOTS (PCN: 74-43-43-21-01-
 033-0011, 74-43-43-21-01-033-0012 AND
 74-43-43-21-10-074-0010)WHICH FORM THE
 'THE SITE'.SUBMIT A COPY OF THE 'UNITY
 OF TITLE' DOCUMENT SO THAT FBC TABLE 600
 BOUNDARY LINE REQUIREMENTS MAY BE DEEMED
 NOT APPLICABLE.
  
 4) DECLARATION OF CONDOMINIUM BEFORE
 C.O. ISSUE.THE COMMENT RESPONSE, DATED
 2/11/04, IS NOTED.
  
 6)FBC* 105.13.1SPECIAL INSPECTOR.
 THIS COMMENT HAS NOT BEEN PROPERLY
 ADDRESSED.THE SUBMITTED 'SPECIAL
 INSPECTOR AGREEMENT' IS MISSING THE LAST
 PAGE, WHICH IS TO BE SIGNED BY THE
 CONTRACTOR AND ARCHITECT/ENGINEER.THE
 AGREEMENT SHALL ALSO BE SIGNED BY THE
 OWNER AND THE JOB INSPECTOR IN THE SPACE
 ALLOCATED.ALL SIGNATURES ARE TO BE
 NOTARIZED ORIGINALS.ALSO, ON SHEET S-0
 THE DRAWING LIST UNDER THE HEADING
 'THRESHOLD BUILDING INSPECTION PLAN
 SHALL INCLUDE ALL RELEVANT ARCHITECTURAL
 SHEETS SUCH AS A.68, A.69, A.70, A.71.
  
 7) SEPARATE SWIMMING POOL PERMIT APPLIC.
 THE COMMENT RESPONSE, DATED 2/11/04, IS
 NOTED.
  
 9) FBC 104.2.2ENERGY CODE COMPLIANCE
 FORMS.THE COMMENT RESPONSE, DATED
 2/11/04, IS NOTED. SHEET 2 OF THE
 SUBMITTED FORM SHALL HAVE THE ORIGINAL
 SEAL AND WET SIGNATURE OF ENGINEER THAT
 PREPARED IT (STEVEN FELLER P.E.).ALSO,
 SHEET 1 SHALL INCLUDE THE PERMIT NUMBER
 (03050107), ADDRESS (403 SAPODILLA AVE),
 ZIP (33401).THREE COPIES ARE REQUIRED.
  
 11) PRODUCT APPROVALS.THIS COMMENT HAS
 NOT BEEN PROPERLY ADDRESSED.NO PRODUCT
 APPROVALS HAVE BEEN SUBMITTED FOR THE
 ROOFING PRODUCTS.THE SUBMITTED MIAMI
 WALL SYSTEMS INC PRODUCT APPROVAL NOA'S
 FOR THE SINGLE HUNG WINDOWS AND SLIDING
 GLASS DOORS DO NOT INCLUDE THE DRAWING
 SHEETS WHICH FORM PART OF THE APPROVAL.
 THE SUBMITTED FLEMING DOOR PRODUCTS LTD
 OUTSWING COMMERCIAL STEEL DOOR PRODUCT
 APPROVAL NOA# 02-0523.06 INCLUDES
 DRAWINGS WHICH DO NOT INCLUDE THE
 REQUIRED MIAMI-DADE PRODUCT CONTROL
 DIVISION APPROVAL STAMP.ALSO, SUBMIT
 THREE COPIES OF COMPLETE PRODUCT
 APPROVALS FOR ALL OF THE PROPOSED
 WINDOW, STOREFRONT, EXTERIOR DOOR AND
 ROOF PRODUCTS.
  
 12) FBC* 104.2.1.2BUILDING DATA.THIS
 COMMENT HAS NOT BEEN PROPERLY ADDRESSED.
 SHEET A.01 SHOWS A NEW HEADING 'BUILDING
 AREA' BUT NO BUILDING AREA INFO, EXCEPT
 THE AREAS OF THE RESIDENTIAL UNIT TYPES,
 HAS BEEN ADDED.ADD THE BUILDING AREA
 INFO.
 NOTE:THE STATED VALUATION FOR PERMIT
 APPLICATION FEE CALCULATION HAS NOT YET
 BEEN REVIEWED DUE TO THE LACK OF THIS
 INFORMATION.ADDITIONAL FEES MAY BE
 DUE (SEE FBC* 104.6.5).
  
 13) FBC 1606.1.1WIND LOAD. THE COMMENT
 RESPONSE, DATED 2/11/04, IS NOTED.
 SUBMIT COPIES OF THE RWDI WIND TUNNEL
 TEST REPORT REFERENCED ON SHEET S-0
 UNDER THE TITLE 'WIND LOADS'.ADD A
 TITLE AND KEY TO SHEETS A.68, A.69,
 A.70 AND A.71 TO CLARIFY WHETHER THAT
 INFORMATION REPRESENTS COMPONENT AND
 CLADDING WIND PRESSURES IN PSF.
  
 18) FBC 412.6SHEETS A.02 AND A.03,
 PARKING LEVEL PLANS. IF DOOR #7 IS BEING
 PROVIDED IN FRONT OF EACH ELEVATOR, IN
 LIEU OF ELEVATOR LOBBIES, HOW IS THE
 REQUIREMENT FOR A SMOKE DETECTOR IN EACH
 ELEVATOR LOBBY (REF: FBC 412.6.3) GOING
 TO BE MET?AMEND THE PLANS (INCL.
 SHEETS LS.1 AND LS.2)
  
 34) FBC 411.2.3PARKING GARAGE LOADING.
 THE 2/11/04 COMMENT RESPONSE AND REVISED
 ARCHITECTURAL SHEET A.03 REFER TO THE
 STRUCTURAL PLANS FOR PARKING GARAGE
 IMPACT LOADING.NO REFERNCE TO THIS
 LOADING COULD BE FOUND ON THE STRUCTURAL
 PLANS.PLEASE CLARIFY.
  
 41) FBC 1010.1SHEETS LS.2 AND A.04.
 ROUTE TO EXIT DISCHARGE FROM STAIR #4.
 SHEET LS.2 SHOWS TWO STAIRS WHILE
 SHEET A.04 & A.15 SHOW ONE.ALSO, SHOW
 DIMENSIONS FOR THE WIDTH OF THE STAIRS
 AND ASSOCIATED GATE, AND PROVIDE TREAD/
 RISER DETAILS FOR THE STAIRS.
  
 42) SHEET S-17, UPPER LEVEL ROOF PLAN.
 AS THE RWDI WIND TUNNEL TEST REPORT HAS
 NOT BEEN SUBMITTED (SEE COMMENT 13) THE
 UPLIFTS ON THE ROOF TRUSSES CANNOT BE
 VERIFIED AT THIS TIME.
  
 45) 61G1-16.004FL. ADMIN. CODE.PLANS
 PREPARED BY A REGISTERED ARCHITECT SHALL
 INCLUDE THE PRINTED NAME OF THE
 ARCHITECT SEALING THE PLANS.THE
 PRINTED NAME AND LICENSE NUMBER ARE FOR
 GUILLERMO J. ENCINOSA BUT THE PLANS ARE
 SIGNED AND SEALED BY STUART COHEN.THE
 PRINTED NAME AND LICENSE NUMBER OF THE
 ARCHITECT MUST MATCH THE SIGNATURE AND
 SEAL ON THE PLANS.
  
 46) FBC 1003.3EGRESS CAPACITY.AMEND
 THE LIFE SAFETY PLANS LS.1 TO LS.5 (LS.2
 IN PARTICULAR) TO SHOW THE CALCULATED
 NUMBER OF OCCUPANT USING EACH EXIT.
  
 47) FBC 1012.1EXTERIOR DOOR (#78) TO
 SOUTH EAST PLAZA.THE WIDTH OF THE EXIT
 ROUTE IS RESTRICTED.AMENT SHEETS A.04,
 A.30 AND LS.2 TO SHOW THIS DOOR AS
 OUTSWING WITH THE HINGES ON THE WEST
 SIDE SUCH THAT THE WIDTH IS NO LONGER
 RESTRICTED BY THE PLANTING.
  
 48) FBC 11-4.13.4SHEET A.48, DOUBLE
 LEAF DOORWAYS 21, 27 & 31 (MIS-LABELLED
 ON SHEET A.04, A.11 & A.12 AS DOOR #22)
 DO NOT HAVE AT LEAST ONE LEAF WITH A
 CLEAR OPENING OF 32".AMEND THE PLANS.
  
 49) FBC 11-4.3.2SHEET A.O4.THE
 ACCESSIBLE RAMP TO THE PATH AROUND THE
 LAWN AREA OF THE COURTYARD IS TOO REMOTE
 FROM FITNESS, CONFERENCE ROOM AND CLUB
 ROOM.AMEND THE PLAN.
  
 50) SHEET A.29PRE-CAST CONCRETE
 ARCHITECTURAL FEATURES/MOLDINGS. PROVIDE
 ATTACHMENT DETAILS FOR THESE ITEMS.
  
 51) FBC 11-413.8DOOR THRESHOLDS. SHEET
 A.43 - DETAIL L AND SHEET A.44-DETAIL.
 THE THRESHOLDS AT EXTERIOR SLIDING DOORS
 SHALL NOT EXCEED 3/4" IN HEIGHT (SEE
 ALSO FAIR HOUSING ACT DESIGN MANUAL
 PAGE 4.14).AMEND THE PLANS.
  
 52) FBC 412.5(3)SHEET M4.01,SMOKE
 CONTROL NOTE C.THIS NOTE DOES NOT MAKE
 SENSE.AMEND THE NOTE TO DEMONSTRATE
 COMPLIANCE WITH FBC 412.5(3).
  
 53) FBC 1005.6.9.9SHEET M4.01, STAIR
 AND ELEVATOR PRESSURIZATION NOTES AND/OR
 SHEET M3.01, CORRIDOR/STAIR RISER
 DIAGRAMS SHALL STATE THE REQUIREMENT FOR
 MIN. 2,500 CFM DISCHARGE THROUGH THE
 RELIEF LOUVERS AND FOR A MAX. 0.35 WATER
 COLUMN COMBINED PRESSURE IN THE STAIR-
 WELLS. ANNOTATE THE PLANS TO DEMONSTRATE
 COMPLIANCE.
  
 54) TO EXPEDITE REVIEW OF A RESUBMITTAL
 WHICH REQUIRES NEW PLANS IN ORDER TO
 ADDRESS THE ABOVE COMMENTS, THE OLD
 SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHOULD BE STAPLED/CLIPPED TO THE
 REMAINING OLD SHEETS FOR COMPARISON OF
 REVISIONS WHEN REVIEWING THE RESUBMITTED
 PLANS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-02-11 Cont ID  
Sent By rbrown Date 2004-02-11 Time 16:35 Rev Time 0.00
Received By rbrown Date 2004-02-11 Time 16:35 Sent To  
Notes
2004-02-11 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 THE PLANS WERE WITHDRAWN BY APPLICANT
 AFTER FIRE AND PLUMBING PLAN REVIEWS, SO
 NO OTHER REVIEWS CAN BE CARRIED OUT.AS
 REVIEWS (TWO) WERE CARRIED OUT ON THE
 2ND RE-SUBMITTAL, AFTER THE ORIGINAL
 APPLICATION, IT SHALL STILL BE COUNTED
 AS THE 3RD REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-11-21 Cont ID  
Sent By rbrown Date 2003-11-21 Time 17:40 Rev Time 0.00
Received By rbrown Date 2003-11-21 Time 14:07 Sent To  
Notes
2003-11-21 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 ***SEE COMMENT #43***
  
 NOTE:
 MANY OF THE PREVIOUS BUILDING/STRUCTURAL
 PLAN REVIEW COMMENTS HAVE NOT BEEN
 ADDRESSED.
 CHAPTER 553.80(2)(B) FLORIDA STATUTES
 STATES THAT A LOCAL GOVERNMENT SHALL
 IMPOSE A FEE OF FOUR TIMES THE FEE FOR
 PLAN REVIEW, IF PLANS ARE REJECTED THREE
 OR MORE TIMES FOR REPEATED FAILURE TO
 CORRECT A CODE VIOLATION.
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 6/19/03:
  
 1) THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY COURTHOUSE
 AND A COPY SUBMITTED TO THIS OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2) IMPACT FEES. THE PLANS SHALL BE TAKEN
 TO PALM BEACH COUNTY BUILDING DEPARTMENT
 FOR IMPACT FEE ASSESSMENT. THEY SHALL BE
 STAMPED AT THAT OFFICE AND A COPY OF THE
 PAID RECEIPT SUBMITTED TO THE CITY OF
 WEST PALM BEACH DEPT OF CONSTRUCTION
 SERVICES BEFORE A PERMIT CAN BE ISSUED.
  
 3) THE PROPOSED BUILDING STRUCTURE
 TRANSGRESSES LEGAL BOUNDARY LINES
 BETWEEN THE LOTS WHICH COMBINE TO FORM
 'THE SITE'.SUBMIT A COPY OF THE 'UNITY
 OF TITLE' DOCUMENT SO THAT FBC TABLE 600
 BOUNDARY LINE REQUIREMENTS MAY BE DEEMED
 NOT APPLICABLE.
  
 4) CONDOMINIUM V APARTMENTS.IF THE
 DWELLING UNITS ARE TO BE SOLD AS
 CONDOMINIUMS, NO CERTIFICATE OF
 OCCUPANCY CAN BE ISSUED UNTIL A
 'DECLARATION OF CONDOMINIUM' HAS BEEN
 SUBMITTED TO THE STATE FOR APPROVAL, AND
 THEN RECORDED WITH THE CLERK OF THE
 COUNTY COURT.A RECORDED COPY SHALL BE
 SUBMITTED TO THE CITY FOR RECORDS,
 ADDRESSING PURPOSES, AND NOTIFICATION OF
 PALM BEACH COUNTY PROPERTY APPRAISER'S
 OFFICE.
  
 5) FBC* 104.4.5 SPECIAL FOUNDATION
 PERMIT. THE BUILDING OFFICIAL MAY, AT
 HIS DISCRETION, ISSUE A SPECIAL PERMIT
 FOR THE FOUNDATION ONLY, UPON WRITTEN
 REQUEST BY THE OWNER AND CONTRACTOR. THE
 HOLDER OF SUCH SPECIAL PERMIT IS PROCEED
 ING AT HIS/HER OWN RISK AND WITHOUT
 ASSURANCE THAT A PERMIT FOR THE
 REMAINDER OF THE WORK WILL BE GRANTED
 AND THAT CORRECTIONS WILL NOT BE
 REQUIRED IN ORDER TO MEET THE PROVISIONS
 OF THE TECHNICAL CODES.
  
 6) FBC* 105.13.1SPECIAL INSPECTOR.A
 STRUCTURAL INSPECTION PLAN MUST BE
 SUBMITTED PRIOR TO THE ISSUANCE OF A
 BUILDING PERMIT FOR THE CONSTRUCTION OF
 A THRESHOLD BUILDING.A THRESHOLD
 BUILDING IS ANY BUILDING WHICH IS
 GREATER THAN THREE STORIES OR 50 FEET IN
 HEIGHT, OR WHICH HAS AN ASSEMBLY
 OCCUPANCY WITH 5,000 SQFT AREA AND
 GREATER THAN 500 OCCUPANTS.THREE
 COPIES OF THE PLANS AND OTHER DOCUMENTS
 WILL BE REQUIRED FOR PERMITTING PURPOSES
  
 7) A SEPARATE PERMIT APPLICATION WILL BE
 REQUIRED FOR THE SWIMMING POOL.
  
 8) THIS COMMENT HAS NOT BEEN ADDRESSED.
 FBC* 1804.2.2SHEET S-0, FOUNDATIONS
 SUBMIT COPIES OF GFA INTERNATIONAL SOIL
 REPORT AS REFERENCED IN THE NOTES.
  
 9) THIS COMMENT HAS NOT BEEN ADDRESSED.
 FBC 13-103.1.1.1 AND 103.1.2SHEET 2
 OF THE SUBMITTED ENERGY CODE COMPLIANCE
 FORMS SHALL BE SIGNED BY THE OWNER (OR
 THE PROJECT ARCHITECT OR OTHER
 AUTHORIZED AGENT DESIGNATED BY THE
 OWNER) TO CERTIFY COMPLIANCE WITH THE
 CODE.ALSO THE ARCHITECT'S NAME AND
 REGISTRATION NUMBER SHALL BE ADDED ABOVE
 THAT OF THE MEP ENGINEER.
  
 10) FBC* F102.2.4FIRE DISTRICT.THE
 ROOF COVERING SHALL CONFORM TO CLASS A
 OR B AS DEFINED IN FBC 1505.AMEND THE
 PLANS TO DEMONSTRATE COMPLIANCE.
  
 11) THIS COMMENT HAS NOT BEEN ADDRESSED.
 SUBMIT PRODUCT APPROVALS FOR THE
 WINDOWS, STOREFRONTS, EXTERIOR DOORS AND
 ROOFING PRODUCTS.
  
 12) THIS COMMENT HAS NOT BEEN ADDRESSED.
 FBC* 104.2.1.2BUILDING DATA.THE
 BUILDING AREAS, CONSTRUCTION TYPE AND
 OTHER CODE/BUILDING DESIGN CRITERIA
 SHALL BE STATED ON THE PLANS(NOTE: TO
 COMPLY WITH TABLE 500 FOR A SPINKLERED,
 TWO STOREY ENCLOSED PARKING GARAGE
 >60,000 SQ FT, TYPE I CONSTRUCTION IS
 REQUIRED)
  
 13) FBC 1606.1.7WIND LOAD.THIS
 COMMENT HAS NOT BEEN PROPERLY ADDRESSED.
 IT IS NOTED THAT SHEET S-0 INCLUDES
 INFORMATION UNDER THE TITLE 'WIND LOADS'
 BUT THE WIND IMPORTANCE FACTOR, INTERIOR
 PRESSURE COEFFICIENT, EXTERIOR COMPONENT
 AND CLADDING WIND PRESSURES MUST ALSO BE
 ADDED.
  
 14) FBC* 104.2.1SHEET A.23.THE NORTH
 ELEVATION DOES NOT SHOW THE FIRST FLOOR
 DOOR #15 (BETWEEN GRIDS T.3 & T.4) TO
 THE VALET.AMEND/CLARIFY.
  
 17) FBC 705.1.2SHEETS LS.1 TO LS.4.
 THIS COMMENT HAS NOT BEEN PROPERLY
 ADDRESSED.AMEND THE LEGEND TO INDICATE
 THE REQUIRED ONE HOUR FIRE RATING FOR
 THE ELEVATOR LOBBIES AND TWO HOUR RATING
 FOR THE WALL TYPE SHOWN AROUND THE STAIR
 SHAFTS, TRASH CHUTE ETC.
  
 18) THIS COMMENT HAS NOT BEEN ADDRESSED.
 FBC 412.6SHEET A.02, PARKING LEVEL
 PLAN.AMEND THE PLAN TO CLARIFY THE
 PURPOSED (I.E. IN LIEU OF ELEVATOR
 LOBBY), CONSTRUCTION AND FIRE-RATING OF
 THE WALL/DOOR THAT HAS BEEN PROVIDED IN
 FRONT OF ELEVATORS 1 TO 3.
  
 20) THIS COMMENT HAS NOT BEEN ADDRESSED.
 FBC 411.2.6SHEETS A.03 & A.48.THE
 PUMP ROOM SHALL BE SEPARATED FROM THE
 PARKING GARAGE BY 1-HOUR FIRE
 RESISTANT CONSTRUCTION.AMEND THE PLANS
  
 23) THIS COMMENT HAS NOT BEEN ADDRESSED.
 FBC TABLES 704.2.4 & 705.1.2SHEETS
 A.04 & A.48.THE MANAGER'S OFFICE
 SUITE, THE CONFERENCE ROOM, CLUB ROOM,
 PANTRY AND FITNESS CENTER ARE ON THE
 EXIT ACCESS CORRIDOR AND SHALL BE AT
 LEAST 30-MINUTE FIRE-RATED WITH
 20-MINUTE FIRE-RATED DOORS (DOOR #'S 16,
 27, 32 AND THE PANTRY DOOR WHICH IS
 INCORRECTLY LABELLED AS DOOR #58). AMEND
 THE PLANS.
  
 26) FBC 11-4-13.6 SHEET A.12 & 13 GROUND
 LEVEL PLANS, MANEUVERING CLEARANCES AT
 DOORS. THE DOORS TO THE CARD ROOM (024),
 CONFERENCE ROOM (016) AND CONFERENCE
 WAITNG ROOM (016), SHALL HAVE A MINIMUM
 OF 18" CLEARANCE BETWEEN THE STRIKE EDGE
 OF THE DOOR AND THE ADJACENT WALL ON THE
 PULL SIDE OF THE DOOR (REF FIG.25A).
 AMEND THE PLANS.THIS COMMENT ALSO
 APPLIES TO THE RESIDENTIAL UNIT ENTRANCE
 DOORS (FOR EXAMPLE GROUND LEVEL UNITS
 A5, A5 MOD, B2.1, B4 AND B6)
  
 28) THIS COMMENT HAS NOT BEEN ADDRESSED.
 FBC 1012.1.4SHEET A.36.THE STOREY
 EXIT DOORS INTO STAIR #3 AT EACH LEVEL
 SHALL LEAVE, UNOBSTRUCTED, AT LEAST ONE
 HALF OF THE REQUIRED LANDING WIDTH.
 AMEND THE PLANS.
  
 29) THIS COMMENT HAS NOT BEEN ADDRESSED.
 FBC 1007.5.5SHEET A.34, STAIR #1 PLANS
 THE HANDRAILS SHALL EXTEND AT LEAST 12"
 HORIZONTALLY BEYOND THE TOP RISER OF
 EACH FLIGHT.THE STAIR #1 PLANS SHOW
 ONLY 11".AMEND THE PLANS.
  
 30) FBC 1015.4GUARDRAIL STRENGTH.THE
 PLANS SHALL BE AMENDED TO STATE THE
 STRENGTH REQUIREMENTS SET OUT IN
 FBC 1608.2
  
 33) THIS COMMENT HAS NOT BEEN ADDRESSED.
 FBC *104.2.1SHEET A.44, DETAIL M,
 SLIDING GLASS DOOR THRESHOLD.THE
 DETAIL SHALL MAKE REFERENCE TO 'THE DOOR
 PRODUCT APPROVAL' FOR ANCHOR
 SPECIFICATION.AMEND THE DETAIL.
  
 34) THIS COMMENT HAS NOT BEEN ADDRESSED.
 FBC 411.2.3AUTOMOBILE PARKING GARAGE,
 GUARDING.THE INTERIOR PARKING GARAGE
 WALLS ADJACENT THE VEHICLE RAMP, STAIR 2
 AND 4, AND THE FRONT WALL OF THE
 ELEVATOR SHAFTS (SEE SHEET S-3) SHALL BE
 DESIGNED TO WITHSTAND IMPACT LOADING IN
 ACCORDANCE WITH FBC 1608.2.3.PROVIDE
 STRUCTURAL DETAILS OF THE WALLS AT THESE
 LOCATIONS.
  
 35) FBC 2405.2THE SHOWER ENCLOSURE
 GLAZING IS IN A 'HAZARDOUS LOCATION' AND
 REQUIRED TO BE SAFETY GLASS SATISFYING
 THE REQUIREMENTS OF THE CONSUMER PRODUCT
 SAFETY COMMISSION 16, CODE OF FEDERAL
 REGULATIONS, PART 1201 (CPSC 16-CFR,
 PART 1201).AMEND THE PLANS TO
 DEMONSTRATE COMPLIANCE.
  
 39) THIS COMMENT HAS NOT BEEN ADDRESSED.
 FBC 11-4.15.2SHEET A.67,DRINKING
 FOUNTAIN SPOUT HEIGHT AND KNEE CLEARANCE
 THE HEIGHT FROM FINISHED FLOOR TO THE
 SPOUT (NOT THE TOP OF THE FOUNTAIN TRAY)
 SHALL BE 36" (REF: FIG. 27A).THE
 DIMENSIONS ARE SHOWN INCORRECTLY ON ONE
 OF THE TWO DETAILS.AMEND THE PLANS.
  
 41) FBC 1010.1SHEET LS.2WHAT IS THE
 ROUTE TO EXIT DISCHARGE FROM STAIR #4?
 AMEND THE PLANS TO CLARIFY.
  
 42) SHEET S-17, UPPER LEVEL ROOF PLAN
 MAKES A NUMBER OF REFERENCES TO HUGHES
 ANCHORS.THAT COMPANY NO LONGER
 SUPPLIES ANCHORS.AMEND THE PLANS TO
 SPECIFY VALID ANCHORS AND STATE THE
 NUMBER AND SIZE FASTENERS.
  
 43) MANY OF THE COMMENTS FROM THE
 PREVIOUS REVIEW HAVE NOT BEEN ADDRESSED.
 A FULL REVIEW HAS NOT BEEN CARRIED OUT
 BECAUSE NO COMMENT RESPONSE LETTERS, OLD
 PLANS OR REVISION CLOUDS/MARKERS WERE
 INCLUDED WITH THE RE-SUBMITTAL.TO
 EXPEDITE THE REVIEW, THE RE-SUBMITTAL
 SHALL INCLUDE AT LEAST ONE OF THE ABOVE
 MEANS OF DESCRIBING THE REVISIONS MADE.
  
 44) IF NEW PLAN SHEETS ARE REQUIRED, IN
 ORDER TO ADDRESS THE ABOVE COMMENTS, THE
 OLD SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHALL BE INCLUDED WITH THE
 RESUBMITTAL FOR COMPARISON OF REVISIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-20 Cont ID  
Sent By rbrown Date 2003-06-19 Time 13:49 Rev Time 0.00
Received By rbrown Date 2003-06-19 Time 13:49 Sent To  
Notes
2003-06-19 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, THE PLANS STAMPED BY THEM
 AND A COPY OF THE RECEIPT SUBMITTED TO
 THE CITY OF WEST PALM BEACH CONSTRUCTION
 SERVICES DEPARTMENT BEFORE A BUILDING
 PERMIT CAN BE ISSUED.
  
 3) THE BUILDING STRUCTURE TRANSGRESSES
 LEGAL BOUNDARY LINES BETWEEN THE LOTS
 WHICH COMBINE TO FORM 'THE SITE'. SUBMIT
 A COPY OF THE UNITIVE TITLE DOCUMENT SO
 THAT FBC TABLE 600 BOUNDARY LINE
 REQUIREMENTS MAY BE DEEMED NOT
 APPLICABLE.
  
 4) CONDOMINIUM V APARTMENTS.IF THE
 DWELLING UNITS ARE TO BE SOLD AS
 CONDOMINIUMS, NO CERTIFICATE OF
 OCCUPANCY CAN BE ISSUED UNTIL A
 'DECLARATION OF CONDOMINIUM' HAS BEEN
 SUBMITTED TO THE STATE FOR APPROVAL, AND
 THEN RECORDED WITH THE CLERK OF THE
 COUNTY COURT.A RECORDED COPY SHALL BE
 SUBMITTED TO THE CITY FOR RECORDS,
 ADDRESSING PURPOSES, AND NOTIFICATION OF
 PALM BEACH COUNTY PROPERTY APPRAISER'S
 OFFICE.
  
 5) FBC* 104.4.5 SPECIAL FOUNDATION
 PERMIT. THE BUILDING OFFICIAL MAY, AT
 HIS DISCRETION, ISSUE A SPECIAL PERMIT
 FOR THE FOUNDATION ONLY, UPON WRITTEN
 REQUEST BY THE OWNER AND CONTRACTOR. THE
 HOLDER OF SUCH SPECIAL PERMIT IS PROCEED
 ING AT HIS/HER OWN RISK AND WITHOUT
 ASSURANCE THAT A PERMIT FOR THE
 REMAINDER OF THE WORK WILL BE GRANTED
 AND THAT CORRECTIONS WILL NOT BE
 REQUIRED IN ORDER TO MEET THE PROVISIONS
 OF THE TECHNICAL CODES.
  
 6) FBC* 105.13.1SPECIAL INSPECTOR.A
 STRUCTURAL INSPECTION PLAN MUST BE
 SUBMITTED PRIOR TO THE ISSUANCE OF A
 BUILDING PERMIT FOR THE CONSTRUCTION OF
 A THRESHOLD BUILDING.A THRESHOLD
 BUILDING IS ANY BUILDING WHICH IS
 GREATER THAN THREE STORIES OR 50 FEET IN
 HEIGHT, OR WHICH HAS AN ASSEMBLY
 OCCUPANCY WITH 5,000 SQFT AREA AND
 GREATER THAN 500 OCCUPANTS.THREE
 COPIES OF THE PLANS AND OTHER DOCUMENTS
 WILL BE REQUIRED FOR PERMITTING.
  
 7) A SEPARATE PERMIT APPLICATION WILL BE
 REQUIRED FOR THE SWIMMING POOL.
  
 8) FBC* 1804.2.2SHEET S-0, FOUNDATIONS
 SUBMIT COPIES OF GFA INTERNATIONAL SOIL
 REPORT AS REFERENCED IN THE NOTES.
  
 9) FBC 13-103.1.1.1 AND 103.1.2SHEET 2
 OF THE SUBMITTED ENERGY CODE COMPLIANCE
 FORMS SHALL BE SIGNED BY THE OWNER (OR
 THE PROJECT ARCHITECT, OR OTHER
 AUTHORIZED AGENT DESIGNATED BY THE
 OWNER) TO CERTIFY COMPLIANCE WITH THE
 CODE.ALSO THE ARCHITECT'S NAME AND
 REGISTRATIONNUMBER SHALL BE ADDED
 ABOVE THAT OF THE MEP ENGINEER.
  
 10) FBC* F102.2.4FIRE DISTRICT.THE
 ROOF COVERING SHALL CONFORM TO CLASS A
 AND B AS DEFINED IN FBC 1505.AMEND THE
 PLANS TO DEMONSTRATE COMPLIANCE.
  
 11) SUBMIT PRODUCT APPROVALS FOR THE
 WINDOWS, STOREFRONTS, EXTERIOR DOORS AND
 ROOFING PRODUCTS.
  
 12) FBC* 104.2.1.2BUILDING DATA.THE
 BUILDING AREAS, CONSTRUCTION TYPE AND
 OTHER CODE/BUILDING DESIGN CRITERIA
 SHALL BE STATED ON THE PLANS.(NOTE: TO
 COMPLY WITH TABLE 500 FOR A SPRINKLERED,
 TWO STOREY, ENCLOSED PARKING GARAGE
 >60,000 SQ FT, TYPE I CONSTRUCTION IS
 REQUIRED)
  
 13) FBC 1606.1.7WIND LOAD.THE PLANS
 SHALL STATE THE BASIC WIND SPEED, WIND
 IMPORTANCE FACTOR, WIND EXPOSURE
 CATEGORY, INTERNAL PRESSURE COEFFICIENT,
 AND EXTERIOR COMPONENT AND CLADDING
 DESIGN WIND PRESSURES.
  
 14) FBC* 104.2.1SHEETS A.22 & A.23.
 THE SOUTH AND NORTH ELEVATIONS DO NOT
 APPEAR TO REPRESENT FENESTRATION AND
 OTHER ARCHITECTURAL FEATURES SHOWN ON
 THE PLANS.FOR EXAMPLE, THE NUMBER OF
 WINDOWS ON THE ELEVATIONS IS DIFFERENT
 TO THE PLANS.PLEASE AMEND/CLARIFY.
  
 15) FBC* 104.2.1SHEET A.02PARKING
 LEVELS B-1 & B-2. STAIR 4 IS INCORRECTLY
 LABELLED AS 'STAIR 2'.AMEND THE PLAN.
  
 16) FBC* 104.2.1SHEET A.35.THE STAIR
 2 PLANS ARE MIS-LABELLED AS 'STAIR 3'.
  
 17) FBC 705.1.2SHEETS LS.1 TO LS.4
 AMEND THE LEGEND TO INDICATE THE
 REQUIRED ONE HOUR RATING FOR THE
 ELEVATOR LOBBIES AND TWO HOUR RATING FOR
 THE WALL TYPE SHOWN AROUND THE STAIR
 SHAFTS, TRASH CHUTE ETC.
  
 18) FBC 412.6SHEET A.02, PARKING LEVEL
 PLAN.AMEND THE PLAN TO CLARIFY THE
 THE PURPOSE, CONSTRUCTION AND
 FIRE-RATING OF THE WALL/DOOR THAT HAS
 BEEN PROVIDED, IN FRONT OF ELEVATORS
 1 TO 3, IN LIEU OF ELEVATOR LOBBIES.
  
 19) FBC 411.4.2SHEET A.02, ENCLOSED
 PARKING GARAGES, MECHANICAL VENTILATION
 AND SMOKE EVACUATION.THE REFERENCE TO
 'STACKED FANS' IS NOTED.ANNOTATE THE
 PLANS TO CLARIFY THE PROVISION OF
 DEDICATED MECHANICAL VENTILATION AT EACH
 LEVEL OF THE PARKING GARAGE.
  
 20) FBC 411.2.6SHEETS A.02 & A.48THE
 PUMP ROOM SHALL BE SEPARATED FROM THE
 PARKING GARAGE BY 1-HOUR FIRE RESISTANT
 CONSTRUCTION.
  
 21) FBC 1012.1.2SHEET A.04, GROUND
 LEVEL PLAN.THE STAIR #2 DOOR SHALL
 OPEN IN THE DIRECTION OF EGRESS.AMEND
 THE PLAN.
  
 22) FBC 1010.3SHEET A.04, GROUND LEVEL
 PLAN, MAIN LOBBY.THE EXIT DISCHARGE
 FROM STAIR #2 IS THROUGH THE MAIN LOBBY
 WHICH MUST THEREFOR SATISFY THE
 REQUIREMENTS OF THE EXCEPTION UNDER
 FBC 1010.3.RECOMMENDATION: PROVIDE TWO
 1-1/2 HOUR CROSS-CORRIDOR DOORS, ONE
 BETWEEN THE STUDIO 'S2' KITCHEN WALL AND
 THE UNIT 'C1' POWDER ROOM WALL OPPOSITE
 AND ONE BETWEEN THE RECEPTION
 ADMINISTRATION AREA AND ELEVATOR #2.
 THIS WOULD LIMIT THE SIZE OF THE EXIT
 DISCHARGE AREA AND SO LIMIT THE
 POTENTIAL RISK OF FIRE/SMOKE INGRESS
 INTO THE EXIT DISCHARGE.
  
 23) FBC TABLES 704.2.4 & 705.1.2SHEETS
 A.04 & A.48. THE RECEPTION ADMINISTRAT'N
 OFFICE, CONFERENCE RM, BUSINESS CENTER,
 FIRE COMMAND CENTER, CLUB ROOM AND
 HEALTH CLUB ARE IN THE EXIT ACCESS
 CORRIDOR AND SHALL BE AT LEAST 30-MINUTE
 FIRE-RATED WITH 20-MINUTE FIRE-RATED
 DOORS (DOOR #'S 16, 17, 18, 20, 26 & 27)
  
 24) SHEET A.04 & A.48THE CA/TV ROOM
 DOOR IS SHOWN AS DOOR REF #30.SHOULD
 THIS BE #38 (SEE DOOR SCHEDULE)?
  
 25) FBC TABLE 704.1SHEET A.13 & A.14
 GROUND LEVEL (PARTIAL) PLAN.THE WALL
 BETWEEN THE CONFERENCE ROOM AND
 UNIT 'A6' IS SHOWN AS TYPE 13, WHICH IS
 NOT A FIRE-RATED WALL TYPE.AMEND THE
 PLAN TO SHOW A MINIMUM OF 1-HOUR FIRE-
 RATING FOR THIS WALL.
  
 26) FBC 11-4.13.6SHEET A.11, GROUND
 LEVEL PLANS, MANEUVERING CLEARANCES AT
 DOORS.THE MEN'S AND WOMEN'S TOILET
 ROOM DOORS FROM CORRIDOR 027 SHALL HAVE
 A MINIMUM OF 18" CLEARANCE BETWEEN THE
 LEADING EDGE OF THE DOOR AND THE
 ADJACENT PERPENDICULAR WALL ON THE PULL
 SIDE OF THE DOOR.AMEND THE PLANS
  
 27) FBC 11-4.13.6 MANEUVERING CLEARANCES
 AT DOORS.THE CONFERENCE ROOM LOBBY,
 BUSINESS CENTER, CLUB ROOM AND HEALTH
 CLUB ENTRANCE DOORS FROM CORRIDOR 027
 (SHEET A.13, GROUND LEVEL) SHALL HAVE A
 MINIMUM 12" CLEARANCE BETWEEN THE
 LEADING EDGE OF THE DOOR AND THE
 ADJACENT RECESSED WALL ON THE PUSH SIDE
 OF THE DOOR IF IT HAS BOTH A CLOSER AND
 A LATCH.AMEND THE PLANS.THIS COMMENT
 ALSO APPLIES TO ALL RESIDENTIAL UNIT
 RECESSED ENTRANCE DOORS (FOR EXAMPLE
 GROUND FLOOR UNITS 'A2' AND 'A4'), IF
 THEY HAVE BOTH A CLOSER AND A LATCH.
  
 28) FBC 1012.1.4SHEET A.36THE STOREY
 EXIT DOORS INTO STAIR #3 AT EACH LEVEL
 SHALL LEAVE UNOBSTRUCTED AT LEAST ONE
 HALF OF THE REQUIRED WIDTH OF THE
 LANDING.AMEND THE PLAN.
  
 29) FBC 1007.5.5SHEET A.34, STAIR #1
 PLANS.THE HANDRAILS SHALL EXTEND AT
 LEAST 12" HORIZONTALLY BEYOND THE TOP
 RISER OF EACH FLIGHT.THE STAIR #1
 PLANS SHOW ONLY 11", AMEND THE PLANS.
  
 30) FBC 1015.4GUARDRAIL STRENGTH.THE
 PLANS SHALL BE AMENDED TO STATE THE
 STRENGTH REQUIREMENTS SET OUT IN
 FBC 1608.2.
  
 31) FBC 1015.3SHEET A.34, A.35 & A.36
 THE PLANS SHALL STATE THE REQUIREMENT
 FOR THE BOTTOM RAIL OF THE GUARDING TO
 BE POSITIONED SUCH THAT A 6" DIAMETER
 SPHERE CANNOT PASS THROUGH THE
 TRIANGULAR OPENING THAT IT FORMS WITH
 THE TREAD AND THE RISER.
  
 32) FBC 1015.3SHEET A.44, DETAIL J.
 THE GUARDRAIL DETAIL SHALL MAKE
 REFERENCE TO THE REQUIREMENTS FOR THE
 SPACING BETWEEN PICKETS TO REJECT THE
 PASSAGE OF A 4" DIAMETER SPHERE, AND FOR
 THE BOTTOM RAIL POSITIONING TO REJECT
 THE PASSAGE OF A 2" DIAMETER SPHERE.
  
 33) FBC* 104.2.1SHEET A.44, DETAIL M,
 SLIDING GLASS DOOR THRESHOLD. THE DETAIL
 SHALL MAKE REFERENCE TO A PRODUCT
 APPROVAL FOR ANCHOR SPECIFICATION.
  
 34) FBC 411.2.3AUTOMOBILE PARKING
 GARAGE, GUARDING.THE INTERIOR PARKING
 GARAGE WALLS ADJACENT THE VEHICLE RAMP,
 STAIR 2 AND 4, AND THE FRONT WALL OF THE
 ELEVATOR SHAFTS SHALL BE DESIGNED TO
 WITHSTAND IMPACT LOADING IN ACCORDANCE
 WITH FBC 1608.2.3.PROVIDE STRUCTURAL
 DETAILS OF THE WALLS AT THESE LOCATIONS.
  
 35) FBC 2405.2THE SHOWER ENCLOSURE
 GLAZING IS IN A 'HAZARDOUS LOCATION' AND
 REQUIRED TO BE SAFETY GLASS SATISFYING
 THE REQUIREMENTS OF THE CONSUMER PRODUCT
 SAFETY COMMISSION 16, CODE OF FEDERAL
 REGULATIONS, PART 1201 (CPSC 16-CFR,
 PART 1201).AMEND THE PLANS TO
 DEMONSTRATE COMPLIANCE.
  
 36) FBC* 104.2.1THE SUBMITTED
 STRUCTURAL PLANS DO NOT PROVIDE A
 COMPLETE DESCRIPTION OF THE STRUCTURE.
 SUBMIT FURTHER STRUCTURAL DETAILS.
  
 37) FBC 11-4.16.4SHEET A.67, GRAB BARS
 AT WATER CLOSETS.THE SIDE GRAB BAR
 SHALL BE A MINIMUM OF 3'6" LONG SUCH
 THAT IT EXTENDS TO NO LESS THAN 54" FROM
 THE REAR WALL (REF: FIGURE 29(B)).THE
 DIMENSIONS ARE SHOWN INCORRECTLY ON ONE
 OF THE TWO DETAILS.AMEND THE PLANS.
  
 38) FBC 11-4.16.2SHEET A.67, CLEAR
 FLOOR SPACE AT WATER CLOSETS.THE
 LAVATORY SHALL BE AT LEAST 18" FROM THE
 CENTER-LINE OF THE W.C. AND 36" FROM THE
 SIDE WALL (REF: FIGURE 28).AMEND THE
 PLANS.
  
 39) FBC 11-4.15.2SHEET A.67, SPOUT
 HEIGHT AND KNEE CLEARANCE.THE HEIGHT
 FROM FINISHED FLOOR TO THE SPOUT (NOT
 THE TOP OF THE FOUNTAIN TRAY) SHALL BE A
 MAXIMUM OF 36" (REF: FIGURE 27(A)).THE
 DIMENSIONS ARE SHOWN INCORRECTLY ON ONE
 OF THE TWO DETAILS.AMEND THE PLANS.
  
 40) IF NEW PLAN SHEETS ARE REQUIRED, IN
 ORDER TO ADDRESS THE ABOVE COMMENTS, THE
 OLD SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHALL BE INCLUDED WITH THE
 RESUBMITTAL FOR COMPARISON OF REVISIONS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 19 Status P Date 2006-10-05 Cont ID  
Sent By dpalmer Date 2006-10-05 Time 09:19 Rev Time 0.00
Received By dpalmer Date 2006-10-05 Time 08:02 Sent To PC
Notes
2006-10-05 00:00:00ARDDRESS COMMENTS FROM REV'S FROM THE
 PREVIOUS YEAR.

Review Stop E ELECTRICAL
Rev No 18 Status N Date 2006-08-05 Cont ID  
Sent By dpalmer Date 2006-08-05 Time 15:06 Rev Time 0.00
Received By dpalmer Date 2006-08-05 Time 15:06 Sent To FIRE
Notes
2006-08-05 00:00:00REVISED FIRE ALARM DEVICES.

Review Stop E ELECTRICAL
Rev No 17 Status F Date 2006-07-05 Cont ID  
Sent By dpalmer Date 2006-07-05 Time 20:40 Rev Time 0.00
Received By dpalmer Date 2006-07-05 Time 20:14 Sent To  
Notes
2006-07-05 00:00:00******** UNSAT *********
  
 1) NOTE: PLEASE SEE ALL REVIEWS I AM
 ATTACHING TO THESE REVIEWS NOTES.
 PLEASE SEE AT LEAST 7 SETS OF REVISIONS
 DATING BACK TO 7/12/05 WHICH HAVE NOT
 BEEN ADDRESSED TO DATE. THIS SEVEN
 REVIEWS ARE STILL BEING SHOWN IN A
 "FALIED" STATUS.
 PLEASE SEE SOME REVISIONS WERE
 SUBMITTED AND PASSED (THREE DATING
 1/4/06,1/5/06, AND 5/17/06). PLEASE SEE
 THAT THESE REVIEWS FOR REVISIONS WHICH
 WERE PLACED INTO A "P" STATUS WERE FOR
 OTHER SHEETS AND NOT FOR THE
 PLANS/REVISIONS WHICH HAD PREVIOUS
 COMMENTS.
  
 ** PLEASE KNOW THAT NO FURTHER
 ELECTRICAL REVISIONS WILL BE REVIEWED
 UNTIL COMPLETE REVISIONS ARE SUBMITTED
 ADDRESSING ALL COMMENTS.
  
 ** PLEASE KNOW A PERMANANT CERTIFICATE
 OF OCCUPANCY WILL NOT BE GRANTED UNTIL
 ALL REVISIONS ARE ADDRESSED 100%.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 16 Status P Date 2006-06-02 Cont ID  
Sent By dpalmer Date 2006-06-02 Time 07:36 Rev Time 0.00
Received By dpalmer Date 2006-06-02 Time 07:25 Sent To  
Notes
2006-06-02 00:00:00REV FOR SHEET 4.01 ONLY.
 REVISED PLANS FOR OTHER ELECTRICAL
 COMMENTS FROM PREVIOUS REVIEW WERE NOT
 SUBMITTED AS OF THIS REVIEW.

Review Stop E ELECTRICAL
Rev No 15 Status F Date 2006-05-17 Cont ID  
Sent By dpalmer Date 2006-05-17 Time 22:35 Rev Time 0.00
Received By dpalmer Date 2006-05-17 Time 22:26 Sent To  
Notes
2006-05-17 00:00:00** UNSAT**
  
 1) NOTE: PLEASE SEE SHEETS 2.01-2.05,
 MANY OF THE RECEPTS FOR LV PLUG IN
 TRANSFORMERS ARE STILL BEING SHOWN ABOVE
 COMBUSTIBLES AND SHELVING AREAS. THIS
 WAS NOTED ON PREVIOUS REVIEWS DATING
 BACK TO INTO "05".PLEASE CLARIFY
 UNITS, AND WHERE THESE PLUG IN
 TRANSFORMER ARE INSTALLED.
  
 PLEASE REVISE AND SUBMIT.
  
 IF THERE ARE ANY QUESTIONS, OR IF THIS
 CNA BE GONE OVER ON THE PHONE, PLEASE
 CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 14 Status P Date 2006-05-17 Cont ID  
Sent By dpalmer Date 2006-05-17 Time 22:26 Rev Time 0.00
Received By dpalmer Date 2006-05-17 Time 22:02 Sent To  
Notes
2006-05-17 00:00:00REV'S IN ELEC FOR REVIEW.
 SHEETS STAMPED,
  
 101,102,103,104,110,111,112,206,301,
 401 AND 402.
  
 PLANS UNSAT ENTERED IN NEXT REVIEW WERE
 SHEETS 201-205

Review Stop E ELECTRICAL
Rev No 13 Status P Date 2006-01-05 Cont ID  
Sent By dpalmer Date 2006-01-05 Time 14:20 Rev Time 0.00
Received By dpalmer Date 2006-01-05 Time 14:20 Sent To FIRE
Notes
2006-01-05 00:00:00REV'S FOR COMMON AREA HALLS, SHEETS
 1.05-1.10 ONLY.
 COMMENTS FOR UNITS STILL NEED TO BE
 ADDRESSED.

Review Stop E ELECTRICAL
Rev No 12 Status P Date 2006-01-04 Cont ID  
Sent By dpalmer Date 2006-01-04 Time 13:10 Rev Time 0.00
Received By dpalmer Date 2006-01-04 Time 13:10 Sent To  
Notes
2006-01-04 00:00:00REV FOR 1.04,1.11,AND 4.02 ONLY.
 NO RESIDENTIAL UNITS.

Review Stop E ELECTRICAL
Rev No 11 Status F Date 2005-12-24 Cont ID  
Sent By dpalmer Date 2005-12-24 Time 14:16 Rev Time 0.00
Received By dpalmer Date 2005-12-24 Time 13:28 Sent To  
Notes
2005-12-24 00:00:00********** UNSAT **********
  
 ** PLEASE SEE REVISONS FOR SOME UNITS
 WHICH WERE STAMPED ON 10/9/05 HAVE SINCE
 BEEN VOIDED.
  
 ** PLEASE SEE NOTE # 3 FROM SECOND
 REVIEW ON 10/9/05 HAS BEEN RECENDED.
 DOOR LOCATED TO SEPARATE BATHRM FROM
 BEDRM FOR UNITS3
  
 ** PLEASE SEE THE FOLLOWING NOTES,
 PLEASE CORRELATE ALL UNITS AND SUBMIT
 REVISIONS FOR ALL UNITS.
  
  
 1)NOTE: PLEASE SEE 210.52C1, C3, C4 FOR
 KITCHEN GFI RECEPT SPACING. PLEASE SEE
 SOME UNITS CONTAIN ADDED RECEPTS FOR
 AREA OF 12' OR MORE WALL SPACE AND
 PENINSULAR, HOWEVER SOME UNITS DO NOT
 SHOW THESE.
 PLEASE SEE ONLY ONE UNIT INDICATES A
 NOTE WITH RESPECT TO 12" OR MORE OF
 SPACE REQUIRING THE ADDITIONAL GFI.
 PLEASE SEE SOME UNITS SEEM TO CLEARLY
 INDICATE 12" OR MORE.
  
 2)NOTE: PLEASE SEE WALL RECEPT MISSING
 IN B1C1 KIT WALL.
 210.52
  
 3)NOTE: PLEASE SEE MANY UNITS HAVE BEEN
 REVISED TO LOCATE THE RECEPT FOR THE LV
 CONTROL PANEL ABOVE DOOR AND PLANS
 INCLUDE A NOTE FOR THIS ALSO, HOWEVER
 PLEASE SEE SOME UNITS WERE NOT CHANGED,
 PLEASE SEE MOST ALL UNITS STILL INDICATE
 A RECEPT IN PANEL AND SOME UNITS EVEN
 MOVED THE RECEPT ABOVE DOOR IN
 LAUNDRY/UTILITY RM? PLEASE KNOW, IF
 THESE PANELS ARE IN THE UTILITY ROOM
 THIS MOVING OF RECEPT ABOVE DOOR IS NOT
 REQUIRED.
 PLEASE ALSO CLARIFY WHY THERE IS A NOTE
 WHICH MENTIONS FOR GROUND FLR UNITS
 ONLY??
 THIS WOULD BE REQUIRED IN ALL UNITS.
  
 110.26.240.24 ETC
  
 PLEASE CALL TO GO OVER COMMENTS.
 WIRING TO UNITS SHOULD BE LIMITED UNTIL
 PLANS ARE CORRECTED AND CLEARED.
  
 A NOTICE WILL BE SENT TO THE CHEIF
 ELECTRICAL INSPECTOR AND ELECTRICAL
 INSPECTOR TO NOTIFY OF CORRECTIONS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 10 Status F Date 2005-10-09 Cont ID  
Sent By dpalmer Date 2005-10-09 Time 12:44 Rev Time 0.70
Received By dpalmer Date 2005-10-09 Time 12:36 Sent To  
Notes
2005-10-09 00:00:00************* UNSAT ***********
  
 ** PLEASE ALSO SEE REVIEW DATED 10/9/05
 WHICH SHEETS 2.01,2.02,2.03 AND 2.04
 HAVE BEEN VOIDED.
 THE FOLLOWING NOTES ARE FOR SHEETS 1.10,
 1.11,1.12,2.05,4.02
  
  
 1)NOTE: PLEASE VERIFY CIRCUITING FOR
 ELEVATOR EQUIPMENT RMS FOR RECEPTS AND
 LTS.
 620.23
 PLEASE SEE 1.10,
 PLEASE ALSO INDICATE FIXTURE TYPE BEING
 BATTERY BACK UP OR PLEASE ADD BATTERY
 BACK UP FIXTURE.
  
 2)NOTE: PLEASE VERIFY FIXTURE TYPE SHOWN
 FOR STAIRWAYS. PLEASE SEE ORIGINAL
 FIXTURE SHCEDULE ON FILE DOES NOT
 CORRELATE WITH FIX TYPE "H">?
 PLEASE ALSO VERIFY IF EVERY OTHER ONE IS
 BATTERY BACK UP.
 PLEASE KNOW THIS WAS NOT A COMMENT ON
 ORIGINAL REVIEWS, HOWEVER FIRE MARSHALS
 OFFICE AND AHJ HAS DETERMIND A BATTERY
 BACK UP FIXTURE WILL BE REQUIRED TO
 MEET MIN FT CANDLES UNDER EMERGENCY
 EXITING. 7.9.2.2, NFPA-101 2000
  
  
  
 4)NOTE: PLEASE VEIFY LANSCAPE LIGHTING
 FIXTURE LOCATIONS.
 120V TO BE A MIN OF 5' FROM WATERS EDGE.
 (GFI PROTECTED)
 LV LTS, MUST BE A MIN OF 10' FROM WATERS
 EDGE. 411.4
  
  
 PLEASE SEE REDLINED PANELS ON 2.02,
 UNITS "B-6 AND B-4
 110.26, 30" MIN WIDTH.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE NAY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 9 Status F Date 2005-12-24 Cont ID  
Sent By dpalmer Date 2005-10-09 Time 12:36 Rev Time 1.00
Received By dpalmer Date 2005-10-08 Time 18:29 Sent To  
Notes
2005-10-09 00:00:00ELECTRICAL REVISIONS , FOR SHEETS
 201,202,203, AND 204 ONLY.
 VOIDED ALL SHEETS PREVIOUSLY STAMPED
 ***************************************
 PLEASE SEE REVIEW ALSO DATED 10/9/05 FOR
 NOTES ON SHEETS
 1.10,1.11,1.12,2.05,4.02.
 **************************************
2005-10-08 00:00:00REV'S IN ELECTRICAL FOR REVIEW.
 NOTES TO FOLLOW ON SOME SHEETS.

Review Stop E ELECTRICAL
Rev No 8 Status F Date 2005-08-09 Cont ID  
Sent By dpalmer Date 2005-08-09 Time 18:23 Rev Time 1.00
Received By dpalmer Date 2005-08-09 Time 18:23 Sent To  
Notes
2005-08-09 00:00:00********* UNSAT *********
  
 REV'S FOR SHEETS E 2.01,2.03,2.04
  
 1)NOTE: PLEASE SEE SOME UNITS, SD'S
 SHALL BE INSTALLED WITHIN 3' OF THE PEAK
 OF A CEILING. PLEASE SEE AREAS IN UNITS
 WHERE SD'S ARE SHOWN ON "LOWERED"
 CEILING AREAS.
 NFPA-72 8-1.4
  
 2)NOTE: PLEASE SEE LT FIXTURES SHOWN
 ABOVE MASTER BATH/ BATH TUBS DOES NOT
 INDICATE ANY CIRCUITING, CONTROL ETC.?
 215.5
  
 3)NOTE: PLEASE SEE 210.52C1 FOR KITCHEN
 COUNTERSPACE MIN RECEPT SPACING.
 UNIT B-2,A-1 MOD, PLEASE SEE ANY OTHER.
 210.52C1-C5
  
 4)NOTE: PLEASE ADJUST "DINING/LIVING"
 RM/AREAS SHOWN ON MOST OF THE "A" UNITS.
 PLEASE SEE LIVING RM IS SHOWN WHERE
 DINING RM CIRCUITS ARE SHOWN AND DINING
 RM WHERE LIVING RM IS SHOWN.
 215.5
  
 ***PLEASE SEE THAT WHEN PLANS ARE
 SUBMITTED, PLEASE SUBMIT THREE COMPLETE
 SETS WITH ALL SHEETS INSERTED INTO SETS
 IN ORDER. A AND E SHEETS WERE PLACED IN
 ORDER AND INTO THREE SETS BY THIS OFFICE
 ON THIS SUBMITTAL. PLEASE BE SURE ALL
 FUTURE PLANS ARE DONE IN ORDER TO
 EXPEDITE THE PLAN REVIEW PROCESS AND
 AVOID ANY POSSIBLE DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REIVEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 7 Status F Date 2005-08-09 Cont ID  
Sent By dpalmer Date 2005-08-09 Time 17:38 Rev Time 0.50
Received By dpalmer Date 2005-08-09 Time 17:21 Sent To  
Notes
2005-08-09 00:00:00** UNSAT **
  
 REV TO SHEET E1.11 AND LANSCAPE PLANS.
  
 PLEASE SEE SOME NOTES FROM PREVIOUS
 REVIEW.
  
 1)NOTE: PLEASE PROVIDE ROOM DESIGNATIONS
 ON ROOF TOP PLANS. PLEASE SEE
 RESUBMITTED PLANS STILL DO NOT INDICATE
 ALL ROOMS?
 PLEASE SEE CIRCUITING AND LOCATIONS OF
 EQUIPMENT TO BE VERIFIED.
 PLEASE SEE THE FOLLOWING COMMENT.215.5
  
 2)NOTE: PLEASE SEE 620.23,620.24 FOR
 REQUIRED DEDICATED BRANCH CIRCUITS FOR
 EACH OF THE ELEVATOR MACHINE ROOMS.
 THESE CIRCUITS MAY NOT BE SHARED WITH
 OTHER AREAS AS SHOWN.
  
 3)NOTE: PLEASE SEE680.22B, NO LIGHTING
 FIXTURES ARE PERMITTED WITHIN THE 5'
 EXTENDING OUTWARD FROM POOL'S WATER
 EDGE. PLEASE SEE LANDSCAPE PLANS ALSO.
 PLEASE ALSO SEE NO LOW VOLTAGE TYPE
 LIGHT FIXTURES ARE PERMITTED WITHIN 10'
 OF WATERS EDGE. THIS IS DUE TO NO
 EQUIPMENT GROUNDING IN LV TYPE FIXTURES
 AND LV SIDE OF TRANSFORMERS.
 411.4
 PLEASE SEE LANSCAPE LIGHTING FIXTURES.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 6 Status F Date 2005-07-12 Cont ID  
Sent By dpalmer Date 2005-07-12 Time 17:40 Rev Time 1.00
Received By dpalmer Date 2005-07-12 Time 17:18 Sent To  
Notes
2005-07-12 00:00:00******** UNSAT *********
  
 1)NOTE: PLEASE SEE MIN ALTERNATING
 CIRCUITS REQUIRED IN EGRESS HALLWAYS, OR
 AN ALTERNATE METHOD TO INSTALL A BATTERY
 BACK UP FIXTURE IN ALTERNATING
 LOCATIONS.
 PLEASE SEE LS 101 7-9, ALTERNATING THE
 HALLS EGRESS CIRCUITS WILL HELP
 ALLEAVIATE LEAVING ANY ONE AREA IN TOTAL
 DARKNESS UPON THE TRIPPING OF ONE
 BREAKER ETC.
 PLEASE ALSO SEE SPEACIAL USEAGE RMS,
 ELEC, FIRE PUMP, FIRE COMMAND RM ETC.
 GEN RM ALREADY SHOWS BATT BACK UP
 FIXTURES ON EM CIRCUIT.
 PLEASE SEE STAIR TOWERS ARE ALREADY
 SHOWN WITH ALTERNATING EM CIRCUITS.
 700.16 ALSO.
  
 2)NOTE: PLEASE PROVIDE ROOM DESIGNATIONS
 ON ROOF TOP PLANS.
 PLEASE SEE THE FOLLOWING COMMENT.
  
 3)NOTE: PLEASE SEE 620.23,620.24 FOR
 REQUIRED DEDICATED BRANCH CIRCUITS FOR
 EACH OF THE ELEVATOR MACHINE ROOMS.
 THESE CIRCUITS MAY NOT BE SHARED WITH
 OTHER AREAS AS SHOWN.
  
 4)NOTE: PLEASE SEE680.22B, NO LIGHTING
 FIXTURES ARE PERMITTED WITHIN THE 5'
 EXTENDING OUTWARD FROM POOL'S WATER
 EDGE.
 PLEASE SEE LANSCAPE LIGHTING FIXTURES.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2005-05-04 Cont ID  
Sent By dpalmer Date 2005-05-04 Time 13:25 Rev Time 4.00
Received By dpalmer Date 2005-05-04 Time 09:56 Sent To  
Notes
2005-05-04 00:00:00REV'S AS LISTED.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-06-15 Cont ID  
Sent By dpalmer Date 2004-06-15 Time 17:01 Rev Time 2.00
Received By dpalmer Date 2004-06-15 Time 16:18 Sent To  
Notes
2004-06-15 00:00:00***NOTE ***
  
 ANY AND ALL LIGHTNING PROTECTION SYSTEM
 SHALL BE UNDER SEPARATE PERMIT AND SHALL
 MEET NFPA-780.
  
 PLANS STAMPED AND SIGNED.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-04-18 Cont ID  
Sent By dpalmer Date 2004-04-18 Time 15:10 Rev Time 2.50
Received By dpalmer Date 2004-04-08 Time 15:08 Sent To  
Notes
2004-04-18 00:00:00************** UNSAT ****************
  
 1)NOTE: PLEASE SEE NOTE FROM LAST REVIEW
 PERTAINING TO INFORMATION REQ'D ON TITLE
 BLOCK FOR ENGINEER AND ENGINEERING FIRM.
 PLEASE SEE FAC 61G15-23.002,NAME OF
 ENGINEER, CERTIFICATE OF AUTHORIZATION
 IS REQ'D. PLEASE SEE FS 471.023
  
 2)NOTE: IT IS NOTED ON RISER FOR A
 MANUAL MEANS OF DISC FOR ATS/FIRE PUMP
 CONTROLLER BEFORE OPENING OF UNIT,
 HOWEVER SPECS SUBMITTED SHOW ONLY A
 POWER OPERATED MEANS OF DISC.
 PLEASE SEE 230.76/ 230.79/110.27
 OPENING OF EQUIPMENT IS NOT PERMITTED
 BY FIRE DEPT PERSONNEL.
 PLEASE CLARIFY SIGNAGE NOTES AS REQ'D
 PER 230.2 REQUESTED ON PREVIOUS REVIEW.
  
  
 3)NOTE: PLEASE SEE LOAD CALCULATIONS
 METER CENTERS SHOWN ON E3.01, THESE
 DO NOT SEEM TO CORRELATE WITH LOADS ON
 E4.01 DPS AND DPN.
 DEMAND KVA DEFERS FROM EACH SHEET.
 NEW COMMENT.
  
 4)NOTE: PLEASE SEE CIRCUITS SHOWN FOR
 DINING RMM RECEPTS, 14,OR15?. PLEASE
 SEE 210.52B1 DINING RM CIRCUIT REQ'D
 TO BE 20A/ #12.
 NEW COMMENT.
  
  
 5)NOTE: ONLY A NOTE, REDLINED RECEPT
 W/IN 6' OF DOOR UNIT"C1" E2.05
  
 6)NOTE: PLEASE SEE NOTE #10 FROM PREVI-
 -OUS REVIEW. NOTES NEED TO BE ADDED FOR
 HARDWARE AND DOORS PER 110.26
 RESPONSE MENTIONS DOORS TO BE LOACKED
 AND ACCESSIBLE TO QUALIFIED PERSONNEL.
 PLEASE SEE THIS IS ONLY ONE OF THE
 REQ'MENTS. 110.26CNEEDS TO BE NOTED.
  
 PLEASE SEE FS 553.80(2)(B), A 4X FEE
 FOR PLAN REVIEW HAS BEEN ADDED TO TO
 ANY OF THE SAME COMMENTS FOR THREE OR
 MORE REVIEWS. PLEASE SEE BLDG REVIEW
 COMMETS. THIS FEE IS REQ'D TO BE PAID
 BEFORE RESUBMITTAL OF PLANS. PLEASE
 ALSO NOTE AN ADDITIONAL 10% RESUB FEE
 WILL ALSO BE DUE.
 THE AMOUNTS ARE AS FOLLOWS.
 $133,200.00 4X FEE FOR PLAN REVIEW FS553
 $22,050.00 FOR 10% RE-SUB FEE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-11-04 Cont ID  
Sent By dpalmer Date 2003-11-04 Time 11:21 Rev Time 5.00
Received By dpalmer Date 2003-11-04 Time 11:21 Sent To  
Notes
2003-11-04 00:00:00******************** UNSAT *************
  
 PLEASE SEE NOTES FROM OTHER REVIEWERS
 THAT MAY HAVE AN AFFECT ON ELECTRICAL
 PLANS.
  
 1)NOTE: PLEASE SEE 700.16 FOR LIGHTING
 IN ELECTRICAL RMS AND THE LIKE.
  
 2)NOTE: PLEASE SEE NOTE FOR LIGHTNING
 PROTECTIONS SYSTEM REFERENCES NFPA 78,
 SHOULD READ 780. (MISPRINT).
  
 3)NOTE: PLEASE CLARIFY MEANS OF EGRESS
 LIGHING ON GRADE LEVEL ACCESS FROM
 GROUND FLR UNITS EXITING TO STREET.
 210.70 AND LS 101
  
 4)NOTE: PLEASE SEE THAT POOL PERMIT WILL
 BE REQ'D TO BE UNDER SEPARATE PERMIT
 ANDWILL REQUIRE A WIRING DIAGRAM FOR
 POOL EQUIPMENT AT THAT TIME.
  
 5)NOTE: PLEASE SEE PLANS FOR UNITS,
 STARTING AT E2.01. KEYNOTES MENTION FOR
 RECEPTS TO HAVE ARC FAULT PROETCTION,
 HOWEVER, PANEL SCHEDULES MENTION TO SEE
 NOTES AND THOSE NOTES MENTION LTS AND
 RECEPTS? PLEASE SEE 210.12.
 PLEASE SEE THE STATE ADOPTED THE 2002
 NEC ON 7/1/03.
  
 6)NOTE: PLEASE SEE THAT WHEN BATHROOMS
 ARE WIRED TO HAVE ALL LIGHTING AND GFI
 RECEPT ON ONE CIRCUIT AS PERMITTED UNDER
 210.11C3, NO OTHER AREAS INCLUDING
 ADDTIONAL BATH(S) MAY BE FED. PLEASE
 ADJUST ALL CIRCUITING ON PLANS AND
 PANEL SCHEDULES.
 PLEASE ALSO SEE 210.52D FOR A COUPLE OF
 MISSING GFI RECEPTS. (B-5)
  
 7)NOTE: PLEASE SEE 210.52 FOR RECEPT
 SPACING. PLEASE SEE 2' OF WALL SPACES
 IN MANY UNITS. ONE SET HAS MANY HIGH-
 -LIGHTED ON YELLOW.
  
 8)NOTE: PLEASE PROVIDE INFORMATION FOR
 FIRE PUMP OCP ETC PER 695.4B
 DISC MEANS? SIGNAGE/NOTES ETC. 230.2,
 230.72 ETC.
 PLEASE SEE THAT THIS INFORMATION IS
 REQ'D ON THESE PLANS. PLEASE ALSO NOTE
 IF ALL SUBMITTALS FOR GENERATOR SYSTEM
 IS NOT SUBMITTED WITH THIS PACKAGE THEN
 GENERATOR SYSTEM WILL BE REQ'D TO BE
 UNDER SEPARATE PERMITS AND ALL ADDTIONAL
 FEES WILL BE REQ'D AT THAT TIME ALSO.
  
 9)NOTE: PLEASE PROVIDE INFORMATION FOR
 MSBR, SHOWN AS HAVING 3 SPACES? AS THIS
 EQUIPMENT IS A MLO UNIT. PLEASE CLARIFY
  
 10)NOTE: PLEASE PROVIDE A NOTE ON ELEC-
 -TRICAL AND BLDG PLANS FOR REQUIREMENTS
 OF 110.26 AND TYPE OF HARDWARE REQ'D
 ON ELECTRICAL ROOM DOORS THAT MEET.
 110.26
  
 11)NOTE: PLEASE SHOW ALL CONTINUOUS LOAD
 -S AT 125% PER 215.3,230.42 ETC.
 INCLUDING LARGEST MOTOR LOADS.
  
 12)NOTE: PLEASE CLARIFY HOW BOTH PANEL
 "H" AND "HA" ARE SHOWN AS SEC 1O2.
  
 13)NOTE: PLEASE CLARIFY METHOD OF
 WATER HEATER?
  
 14)NOTE: PLEASE SEE FAC 61G15-23.002 AND
 PLEASE INCLUDE ALL INFORMATION SET FORTH
 AND REQUIRED PER THIS AND FS 471
 THIS IS REQ'D FOR ALL TRADES WEATHER OR
 NOT COMMENTED ON.
  
 15)NOTE: PLEASE SEE COPY OF FS 553.80(2)
 (B) ATTACHED. THIS IS REQ'D TO GO OUT
 ON ANY PROJECT OF REVIEW THAT HAS HAD
 ONE/OR ANY OF THE PREVIOUS COMMENTS THE
 SECOND TIME. THIS IS ONLY A NOTICE.
  
 PLEASE NOTE: A RESPONSE LETTER WILL
 USUALLY HELP THE PROCESS OF PLAN REVIEW
 AND BEING ABLE TO ISSUE PERMIT.
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 INSERT NEW SHEETS INTO TWO COMPLETE SETS
 FOR REVIEW AND STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-05-13 Cont ID  
Sent By dpalmer Date 2003-05-13 Time 15:36 Rev Time 3.00
Received By dpalmer Date 2003-05-13 Time 15:36 Sent To  
Notes
2003-05-13 00:00:00*********** UNSAT ******************
  
 PLEASE COMPLETE PLANS FOR SUFFICIENT
 REVIEW.
  
 PLANS MISSING CIRCUIT #`S,MISSING ITEMS
 LOADS/WIRE/OCP ON PANEL SCHEDULES.
  
 PLEASE SUBMIT MORE INFORMATION FOR FIRE
 PUMP/CONTROLLER ETC. 695-4B,,,,,
 LOCATION OF DISC MEANS, SIGNAGE NOTES,
 ETC. 230-2/-230-72
  
 PLEASE NOTE, FEEDER SCHEDULE IS SHOWN
 ON RISER, HOWEVER, (#) NOTES ARE NOT
 COMPLETED ON RISER?
  
 PLEASE SEE MISSING CIRCUITING FOR EF`S
 ETC.
  
 PLEASE SEE A COUPLE OF SD`S MISSING.
 TO BE INSIDE AND OUTSIDE ALL SLEEPING
 ROOMS. NFPA-72 8-1.4.2
  
 PLEASE CLARIFY HOW ALL UNITS SHOW SAME
 LOAD AND UNITS ARE DIFFERENT SIZES??
  
  
  
  
 PLEASE NOTE, MOST OF THE ABOVE PERTAIN
 TO ART 215-5
 PLEASE ALSO NOTE, ONCE PLANS ARE
 COMPLETED, THERE MAY BE OTHER COMMENTS
 TO FOLLOW.
 PLEASE SUBMIT ALL OF THE ABOVE INFORMAT-
 -ION FOR REVIEW. PLEASE TAKE OUT ALL OLD
 /VOIDED SHEETS AND SUBMIT COMPLETE SETS
 FOR REVIEW.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 9 Status   Date   Cont ID  
Sent By   Date 2006-05-11 Time   Rev Time 0.00
Received By   Date 2006-05-11 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 8 Status   Date   Cont ID  
Sent By   Date 2006-05-11 Time   Rev Time 0.00
Received By   Date 2006-05-11 Time   Sent To  
Notes
2006-05-11 00:00:00STILL TESTING

Review Stop ENG ENGINEERING CSD
Rev No 7 Status   Date   Cont ID  
Sent By   Date 2006-05-11 Time   Rev Time 0.00
Received By   Date 2006-05-11 Time   Sent To  
Notes
2006-05-11 00:00:00SYSTEM TEST
 SYSTEM TEST

Review Stop ENG ENGINEERING CSD
Rev No 6 Status N Date 2006-05-11 Cont ID  
Sent By lmartine Date 2006-05-11 Time 09:42 Rev Time 0.00
Received By lmartine Date 2006-05-11 Time 09:41 Sent To  
Notes
2006-05-11 00:00:00TEST NOTES FOR REVIEWER
 TESTING SYSTEM

Review Stop ENG ENGINEERING CSD
Rev No 5 Status P Date 2006-01-20 Cont ID  
Sent By mamini Date 2006-01-20 Time 11:00 Rev Time 0.50
Received By mamini Date 2006-01-20 Time 11:00 Sent To  
Notes
2006-01-20 00:00:00PASSED:
  
 1. REVIEWED FOR REVISION SHEETS C-5-C
 AND C-5-D.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 4 Status P Date 2005-04-25 Cont ID  
Sent By mamini Date 2005-04-25 Time 15:35 Rev Time 0.50
Received By mamini Date 2005-04-25 Time 15:34 Sent To  
Notes
2005-04-25 00:00:00PASSED:
  
 1. REVIEWED FOR THE REVISIONS.
  
 2. PLEASE NOTE THAT WORK WITHIN PUBLIC
 R.O.W REQUIRES PERMIT (R.O.W PERMIT)
 FROM PUBLIC UTILITIES AND ENGINEERING,
 CONTACT WINDEL PALMER 494-1086.PLEASE
 SUBMIT M.O.T PLANS AT THE TIME OF
 APPLICATION.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2004-04-13 Cont ID  
Sent By mamini Date 2004-04-13 Time 10:46 Rev Time 1.00
Received By mamini Date 2004-04-13 Time 10:46 Sent To  
Notes
2004-04-13 00:00:00PASSED WITH PROVISOS:
 1. INSTALLATION OF SHEET PILLING IN
 PUBLIC R.O.W, REQUIRES A FOOTING AND
 ARIAL FACADE EASEMENT AGREEMENT WITH
 PLANNING DEPARTMENT, 659-8031.
 2. WORKING IN PUBLIC R.O.W REQUIRES
 PERMIT FROM CITY ENGINEER, RECHARD
 PITTMAN. M.O.T PLANS ALSO MUST BE
 APPROVED PRIOR TO BEGIN WORK.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2003-11-06 Cont ID  
Sent By mamini Date 2003-11-06 Time 08:36 Rev Time 1.00
Received By mamini Date 2003-11-06 Time 08:36 Sent To  
Notes
2003-11-06 00:00:00FAILED:
 1. PLEASE NOTE THAT A SEPARATE PERMIT
 APPLICATION AND FEES FOR "UNDERGRPOUND
 UTILITIES AND SITE WORK" PERMIT IS
 REQUIRED, SUBMIT TWO SETS OF CIVIL PLANS
 ONLY SIGNED & SEALED, APPROVED & STAMPED
 BY THE PUBLIC UTILITIES AND ENGINEERING.
 2. PLEASE STATE THAT IF DRANAGE SYSTEM
 FOR THE ENTIRE SITE IS APPROVED BY
 STEVE SARLEY, DRANAGE ENGINEER.HOWEVER
 PERVIOUS AND IMPERVIOUS AREA CALC.
 AND TOTAL SITE AREA MUST BE SUBMITTED AT
 THE TIME OF ACTUAL PERMITTING.
 3. SHEET C-5 DOES NOT SHOW THE EXISTING
 INLETS AT CORNERS OF S. SAPODILLA AND
 GARDENIA, ARE THEY REMOVED,RELOCATED ?
 4. WORKING IN PUBLIC R.O.W REQUIRES
 PERMIT FROM CITY ENGINEER, RECHARD
 PITTMAN.M.O.T PLANS FOR WORKING IN
 PUBLIC R.O.W MUST ALSO BE APPROVED BY
 CITY ENGINEER PRIOR TO WORK BEGINS
 659-8040.
 5.INSTALLATION OF SHEET PILING IN PUBLIC
 R.O.W AS SHOWN, SHEET C-5 REQUIRES A
 FOOTING AND AERIAL FACADE EASEMENT
 AGREEMENT WITH PLANNING DEPARTMENT,
 659-8031.
 6. INSTALLATION OF 8' SAFETY FENCE ALL
 AROUND THE SITE DURING THE CONSTRUCTION
 IS REQUIRED.
 7. ACCESSIBLE CURB RAMPS AT ALL INTER-
 SECTION CORNERS MUST PROVIDED.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2003-05-06 Cont ID  
Sent By mamini Date 2003-05-06 Time 08:57 Rev Time 1.00
Received By mamini Date 2003-05-06 Time 08:57 Sent To  
Notes
2003-05-06 00:00:00FAILED:
 1. PLEASE NOTE THAT A SEPARATE PERMIT
 APPLICATION AND FEES FOR UNDERGROUND
 UTILITIES AND SITE WORK IS REQUIRED.
 2. PLEASE SUBMIT CALCULATION FOR STORM
 WATER AND INCLUDE PERVIOUS & IMPERVIOUS
 AREA FOR ENTIRE SITE.
 3. ALL CONNECTION TO CITY SERVICES AND
 REMOVAL/ABANDONING OF EXISTING SERVICES
 MUST BE APPROVED BY PUBLIC UTILITIES.
 4. WORK IN PUBLIC R.O.W REQUIRES A
 SEPARATE PERMIT FROM CITY ENGINEER'
 OFFICE, ATT. RICHARD PITTMAN
 5. M.O.T PLANS FOR CONSTRUCTION WITHIN
 PUBLIC R.O.W OR ANY LANE CLOSURE MUST BE
 SUBMITTED TO CITY ENGINEER' OFFICE FOR
 APPROVAL PRIOR TO BEGINNING THE WORK.
 6. ALL SIDEWALKS, CURB & GUTTERS, H.C
 RAMPS ALONGE THE PROPERTY (ALL SIDE)
 THAT ARE REMOVED/DAMAGED MUST BE
 REPLACED PER CITY REQUIREMENTS AND
 DIRECTION.
 7. POLLUTION/ EROSION PLANS AS SHOWN ON
 SHEET C-11 MUST BE INSTALLED IN FIELD
 PRIOR TO ANY SITE WORKS.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 21 Status P Date 2006-08-21 Cont ID  
Sent By mawillia Date 2006-08-21 Time 11:26 Rev Time 0.00
Received By mawillia Date 2006-08-21 Time 11:26 Sent To  
Notes
2006-08-21 00:00:00**APPROVED**
  
  
  
  
 PLANS REVIEWED AND OKAYED WERE FA1.01,
 FA1.02 AND FA1.10.

Review Stop FIRE FIRE DEPARTMENT
Rev No 20 Status P Date 2006-08-21 Cont ID  
Sent By nmccray Date 2006-08-21 Time 10:46 Rev Time 0.00
Received By nmccray Date 2006-08-21 Time 10:20 Sent To  
Notes
2006-08-21 00:00:00FIRE ALARM REVISIONS DATED 06/19/06

Review Stop FIRE FIRE DEPARTMENT
Rev No 19 Status P Date 2006-08-14 Cont ID  
Sent By mawillia Date 2006-08-14 Time 11:22 Rev Time 0.00
Received By mawillia Date 2006-08-14 Time 11:22 Sent To  
Notes
2006-08-14 00:00:00**RECEIVED**
  
  
  
 1.) SPECS AND CUT SHEETS ON FIRE ALARM
 DEVICES.

Review Stop FIRE FIRE DEPARTMENT
Rev No 18 Status P Date 2006-06-23 Cont ID  
Sent By mwennerg Date 2006-06-23 Time 14:52 Rev Time 0.00
Received By mwennerg Date 2006-06-23 Time 14:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 17 Status N Date 2006-06-16 Cont ID  
Sent By mwennerg Date 2006-06-16 Time 11:45 Rev Time 0.00
Received By mwennerg Date 2006-06-16 Time 11:45 Sent To  
Notes
2006-06-16 00:00:00NO NEW FIRE PROTECTION SHEETS SUBMITTED
 SINCE LAST FIRE REVIEW. ANY REVISIONS
 SUBMITTED FOR FIRE PROTECTION SYSTEMS
 SHALL BE SUBMITTED AS SHOP DRAWINGS
 UNDER THE APPROPRIATE PERMIT.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 16 Status F Date 2006-04-06 Cont ID  
Sent By mwennerg Date 2006-04-06 Time 13:45 Rev Time 0.00
Received By mwennerg Date 2006-04-06 Time 13:45 Sent To  
Notes
2006-04-06 00:00:00******DENIED******
  
 REVISION
  
 1) PLEASE SEE BUILDING REVIEW COMMENT
 REGARDING SIGNING AND SEALING
 REQUIREMENTS.
  
 2) NEW ARRANGEMENT MUST BE INSPECTED,
 TESTED AND APPROVED BY THIS OFFICE UPON
 INSTALLATION.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 15 Status P Date 2006-01-05 Cont ID  
Sent By mwennerg Date 2006-01-05 Time 14:13 Rev Time 0.00
Received By mwennerg Date 2006-01-05 Time 14:12 Sent To  
Notes
2006-01-05 00:00:00REVISION ELECTRICAL SHTS

Review Stop FIRE FIRE DEPARTMENT
Rev No 14 Status P Date 2005-12-30 Cont ID  
Sent By mwennerg Date 2005-12-30 Time 14:03 Rev Time 0.00
Received By mwennerg Date 2005-12-30 Time 14:03 Sent To  
Notes
2005-12-30 00:00:00REVISION DATED 10/19/05

Review Stop FIRE FIRE DEPARTMENT
Rev No 13 Status P Date 2005-10-12 Cont ID  
Sent By mwennerg Date 2005-10-12 Time 16:03 Rev Time 0.00
Received By mwennerg Date 2005-10-12 Time 16:03 Sent To  
Notes
2005-10-12 00:00:00REVISIONS DATED 8/16/05, 8/25/05, 9/6/05
 8/10/05, 8/3/05, 8/29/05 FOR SHTS A.21,
 A.21A, A.22, A.23, A.24, A.24A, E.1.10,
 E.1.11, E.1.12, E.2.01, E.2.02, E.2.03,
 E.2.04, E.2.05, E.4.02, P.1.03, P.1.10,
 M.2.03, M.2.04.

Review Stop FIRE FIRE DEPARTMENT
Rev No 12 Status P Date 2005-08-29 Cont ID  
Sent By nmccray Date 2005-08-29 Time 15:45 Rev Time 0.00
Received By nmccray Date 2005-08-29 Time 15:45 Sent To  
Notes
2005-08-29 00:00:00REV A.41,A.42, & A.42A - E1.11 DATED
 07/22/05

Review Stop FIRE FIRE DEPARTMENT
Rev No 11 Status F Date 2005-08-16 Cont ID  
Sent By mwennerg Date 2005-08-16 Time 13:12 Rev Time 0.00
Received By mwennerg Date 2005-08-16 Time 13:12 Sent To  
Notes
2005-08-16 00:00:00******DENIED******
  
 PLEASE SEE ELECTRICAL REVIEW COMMENT
 REF: TO LOCATION OF SOME SMOKE
 DETECTORS.
  
  
 MIKE WENNERGREN, CAPTAIN
 WPBFR(561) 804-4756
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 10 Status F Date 2005-07-20 Cont ID  
Sent By mwennerg Date 2005-07-20 Time 15:10 Rev Time 0.00
Received By mwennerg Date 2005-07-20 Time 15:10 Sent To  
Notes
2005-07-20 00:00:00******DENIED******
  
 1) PLEASE SEE COMMENT BY ELECTRICAL PLAN
 REVIEW IN REGARDS TO EMERGENCY LIGHTING
 IN REQUIRED MEANS OF EGRESS.
  
  
 MIKE WENNERGREN, CAPTAIN
 WPBFR(561) 805-6722 OR 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 9 Status P Date 2005-06-03 Cont ID  
Sent By nmccray Date 2005-06-03 Time 12:50 Rev Time 0.00
Received By nmccray Date 2005-06-03 Time 12:50 Sent To  
Notes
2005-06-03 00:00:00FIRE PUMP SUBMITTAL OK

Review Stop FIRE FIRE DEPARTMENT
Rev No 8 Status P Date 2005-06-02 Cont ID  
Sent By nmccray Date 2005-06-02 Time 15:21 Rev Time 0.00
Received By nmccray Date 2005-06-02 Time 15:21 Sent To  
Notes
2005-06-02 00:00:00FIRE PUMP SUBMITTALS APPROVED 6-02-05

Review Stop FIRE FIRE DEPARTMENT
Rev No 7 Status P Date 2005-05-09 Cont ID  
Sent By mwennerg Date 2005-05-09 Time 12:58 Rev Time 0.00
Received By mwennerg Date 2005-05-09 Time 12:58 Sent To  
Notes
2005-05-09 00:00:001) REVISION DATED 5/5/05

Review Stop FIRE FIRE DEPARTMENT
Rev No 6 Status P Date 2005-02-14 Cont ID  
Sent By nmccray Date 2005-02-14 Time 11:10 Rev Time 0.00
Received By nmccray Date 2005-02-14 Time 11:09 Sent To  
Notes
2005-02-14 00:00:00FIRE ALARM SUBMITTAL 02/03/05

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2004-06-23 Cont ID  
Sent By mcarsill Date 2004-06-16 Time 14:20 Rev Time 0.00
Received By mcarsill Date 2004-06-16 Time 14:20 Sent To  
Notes
2004-06-16 00:00:001) ELECTRONIC SWITCHES, CHAIN AND LOCK
 REQUIRED ON FIRE LINE BACKFLOW DEVICE.
  
 2) TACTILE SIGNAGE REQUIRED AT ALL
 EXITS.
  
 3) PLEASE LABEL ALL STRETCHER ACCESSIBLE
 ELEVATORS WITH SIGNAGE.
  
 4) EXIT SIGN NEEDED ADJACENT TO
 BUSINESS CENTER TO DIRECT PERSONS TO
 EXIT SIGN NEAR MAIL ROOM.
  
 5) VERIFY DOOR SWINGS. DOUBLE DOORS NEAR
 ASST. MANAGER OFFICE SWINGING IN THE
 RIGHT DIRECTION. CORRIDOR 027 SWINGS
 IN.
  
 6) NO ELECTRIC OR EQUIPMENT ALLOWED WITH
 STAIRWELLS EXCEPT THAT IS ALLOWED UNDER
 NFPA 101, LIFE SAFETY CODE, 2000 EDITION
 CHAPTER SEVEN.
  
 7) ALL SMOKE DETECTORS SHALL BE A
 MINIMUM OF THREE FEET OF AC DIFFUSERS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status F Date 2004-03-19 Cont ID  
Sent By mcarsill Date 2004-03-19 Time 14:20 Rev Time 0.00
Received By mcarsill Date 2004-03-19 Time 14:20 Sent To  
Notes
2004-03-19 00:00:001) HANDRAIL MISSING FROM ONE SIDE OF
 STAIR ON THE EXTERIOR OF THE GENERATOR
 ROOM.
  
 2) HANDRAILS REQUIRED AT ARCH-6 AT
 SOUTH ELEVATION ON PAGE A.22.
  
 3) NOTE ON PAGE A-48 IS INCORRECT. ALL
 DOORS MUST COMPLY WITH NFPA 101, CHAPTER
 SEVEN.
  
 4) DOOR SWINGS IN CORRIDOR ADJACENT TO
 ASST. MGR OFFICE DO NOT APPEAR TO
 SWING IN THE PROPER DIRECTION.
  
 5) IT APPEARS THAT ADDITIONAL STRIPING
 WILL BE REQUIRED ON THE LOADING DOCK
 ADJACENT TO THE EXIT DOOR LOCATED ON
 THE WEST SIDE.
  
 6) THE PLACEMENT OF EXIT SIGNS SHALL
 NOT EXCEED 100 FEET.
  
 7) EXITING FROM THE MAIN ROOF SHALL BE
 OBVIOUS AND DIRECT.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2004-02-10 Cont ID  
Sent By mcarsill Date 2004-02-10 Time 14:28 Rev Time 0.00
Received By mcarsill Date 2004-02-10 Time 14:28 Sent To  
Notes
2004-02-10 00:00:001) PLEASE EXPLAIN HOW STAIRS ON THE
 LOADING DOCK CAN ACCOMODATE THE
 OCCUPANT LOAD FROM STAIR # 1. ALSO
 HOW WILL EXIT DISCHARGE BE MAINTAINED
 FROM THE EXIT DOOR OF STAIR # 1 THROUGH
 THE LOADING DOCK.
  
 2) PLEASE EXPLAIN COMMENT PERMIT
 RESPONSE # 9. PLEASE CLARIFY.
  
 3) FIRE ALARM NOTE ON PAGE FA1.03 IS
 INCORRECT. THE FIRE ALARM SYSTEM
 SHALL BE LISTED FOR CENTRAL STATION
 SERVICE. PLEASE REVISE.
  
 4) ITEMS # 15 AND # 16 SHALL BE
 INDICATED ON THE PLANS. PLEASE REVISE.
  
 5) NOTE # 18 PERMIT COMMENT RESPONSE
 NEEDS FURTHER CLARIFICATION. ANY
 ELECTRONIC LOCKS ON EXIT DOORS SHALL
 COMPLY WITH ACCESS CONTROL OR
 DELAYED EGRESS. PLEASE REVIEW
 APPLICABLE CODE SECTIONS AND ANNOTE
 PLANS.
  
 6) HANDRAILS SHALL BE PROVIDED ON ALL
 NEW STAIRS. ALSO HANDRAILS ARE REQUIRED
 WITHIN 30" OF ALL REQUIRED WIDTHS USED
 FOR EXITING.
  
 7) EXIT SIGN MISSING AT EXTERIOR DOOR
 OF STAIR # 3.
  
 8) ONLY ONE FIRE HYDRANT SHOWN ON C-5.
 PLEASE CLARIFY.
  
 9) NOTE # 29, NO PERMIT RESPONSE
 PROVIDED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2003-10-30 Cont ID  
Sent By mcarsill Date 2003-10-28 Time 16:59 Rev Time 0.00
Received By mcarsill Date 2003-10-28 Time 16:59 Sent To  
Notes
2003-10-30 00:00:001) STAIR # 4 DOOR ON PAGE A.02 SWINGS
 IN THE WRONG DIRECTION. DOOR SWINGS
 OUT, SHOULD SWING IN. B-2 LEVEL.
  
 2) SAME CONDITION, SAME LOCATION OCCURS
 ON PAGE A.03. B-1 LEVEL.
  
 3) PLEASE EXPLAIN EXITING RATIONALE
 FROM THE BUILDING. PLEASE INDICATE
 WHICH STAIRS LEAD DIRECTLY TO THE
 EXTERIOR AT GROUND LEVEL.
  
 4) COURTYARD AREA DISPLAYS STAIRS ABSENT
 OF HANDRAILS.
  
 5) PLEASE EXPLAIN HOW EXITING OCCURS
 NEAR THE BIKE STORAGE AREA. IT APPEARS
 THRU THE LOADING DOCK. PLEASE EXPLAIN
 RATIONALE.
  
 6) STAIR # 1 APPEARS TO DISCHARGE ONTO
 THE LOADING DOCK. PLEASE EXPLAIN.
  
 7) KNOX-BOX NOT REQUIRED IN FIRE
 COMMAND ROOM. KNOX-BOXES ARE REQUIRED
 TO GAIN ACCESS FROM THE EXTERIOR OF
 THE BUILDING. THEY ARE NOTED ON THE
 DRAWINGS.
  
 8) ALL PREVIOUSLY PLAN REVIEW COMMENTS
 NOTED ON JUNE 6, 2003 HAVE NOT BEEN
 ADEQUATELY ADDRESSED.
  
 9) PLEASE EXPLAIN "SMOKE DETECTOR NOTE
 ON FA1.10 CONNECT DELUGE SYSTEM TO
 FIRE ALARM PANEL AS REQUIRED".
  
 10) FIRE ALARM EQUIPMENT NOTED IN
 STAIR # 2. PLEASE REVIEW CODE SECTIONS
 FOR ITEMS ALLOWED IN STAIRWELL.
  
 11) ALL FIRE ALARM SYSTEMS THAT
 SUPERVISE AUTOMATIC FIRE SPRINKLER
 SYSTEMS AS OF AUGUST 1, 2003, MUST BE
 UL LISTED FOR CENTRAL STATION SERVICE.
  
 12) FPS.02 DISPLAYS THREE FIRE
 DEPARTMENT CONNECTIONS. ONLY TWO ARE
 NEEDED.
  
 13) NOTE # 29 ON FP3.01 IS INCORRECT.
 STANDPIPES ERECTED DURING CONSTRUCTION
 ARE REQUIRED WHEN CONSTRUCTION REACHES
 30 FEET NOT 50 FEET.
  
 14) ALL SPRINKLERS SHALL BE QUICK
 RESPONSE TYPE.
  
 15) TACTILE SIGNAGE REQUIRED AT ALL
 STAIRWELLS.
  
 16) HOW IS THE 4" PIPING FOR THE
 STANDPIPE SYSTEM THAT RUNS BELOW
 THE POOL DECK GOING TO BE INSPECTED
 OR MAINTAINED IN THE FUTURE.
  
 17) SMOKE CONTROL NOTES SHALL MENTION
 ANTICIPATED STACK EFFECT.
  
 18) PLEASE EXPLAIN MAGNETIC LOCKS TIED
 TO FIRE ALARM SYSTEM. LOCKING
 DEVICES ON EXIT DOORS TO COMPLY WITH
 ACCESS CONTROLLED EGRESS WITH ALL
 CODE PARAMETERS BEING MET.
  
 19) NO REVISIONS COULD BE LOCATED
 ON THE DRAWINGS.
  
 20) PLEASE PROVIDE PRODUCT APPROVALS
 FOR INSULATION PLANNED FOR AROUND
 TRASH CHUTE.
  
 21) PLEASE PROVIDE STRENGTH REQUIREMENTS
 FOR HANDRAILS.
  
 22) ALL CONCRETE STAIRS ON RECREATION
 DECK SHALL BE EQUIPPED WITH HANDRAILS
 ON BOTH SIDES.
  
 23) HANDRAILS ARE REQUIRED FOR STAIRS
 ON UPPER PLAZA.
  
 24) PROVIDE CONSTRUCTION DATA.
  
 25) BUILDING ADDRESS REQUIRED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-06-06 Cont ID  
Sent By mcarsill Date 2003-06-06 Time 15:53 Rev Time 0.00
Received By mcarsill Date 2003-06-06 Time 15:53 Sent To  
Notes
2003-06-06 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO, DURING, AND AFTER CONSTRUCTION.
  
 2) TEMPORARY STANDPIPES ARE REQUIRED
 WHEN CONSTRUCTION REACHES THREE STORIES
 OR THIRTY FEET IN HEIGHT.
  
 3) EXIT STAIRS ARE REQUIRED DURING
 CONSTRUCTION.
  
 4) ALL CONSTRUCTION WORK IS TO COMPLY
 WITH NFPA 241.
  
 5) DOOR AT STAIR # 2 SWINGS OUTWARD
 INSTEAD OF INWARD.
  
 6) BOTH STAIRS ON L.S.1 ARE LABELED
 STAIR # 2.
  
 7) PLEASE INDICATE ALL DEVICES AND
 EQUIPMENT THAT WILL BE CONTAINED
 IN THE FIRE COMMAND ROOM. PLEASE SEE
 FBC 412.4.1.
  
 8) PLEASE PROVIDE MORE DETAILS ON
 SECRUITY LOCKS PLANNED FOR EXIT
 DOORS.
  
 9) ALL STAIRS AND RAMPS ARE REQUIRED
 TO HAVE HANDRAILS ON BOTH SIDES.
  
 10) STAIR # 2 AT GROUND LEVEL SWINGS
 INWARD INSTEAD OF OUTWARD.
  
 11) PLEASE PROVIDE PRESCRIPTIVE STRENGTH
 REQUIREMENTS FOR ALUMINUM AND RAILINGS.
  
 12) LOCATION MAY BE LOCATED IN THE
 CITY FIRE LIMITS. CERTAIN RESTRICTIONS
 MAY APPLY.
  
 13) BUILDING ADDRESS REQUIRED ON PROPER
 ELEVATION.
  
 14) A TWO HOUR FIRE SEPARATION IS
 REQUIRED BETWEEN THE PARKING GARAGE
 AND THE BUILDING.
  
 15) PROVIDE INFORMATION ON INSULATION
 PLANNED FOR THE TRASH CHUTE.
  
 16) WHY ARE STAIR # 2 AND STAIR # 3
 POSITIONED SO CLOSE TOGETHER.
  
 17) INDICATE TYPE OF CONSTRUCTION.
  
 18) INDICATE CODE DATA.
  
 19) VICINITY SPELLED WRONG ON PLANS.
  
 20) WHY IS THE FIRE PUMP ROOM LOCATED
 ON PARKING LEVEL B-2.
  
 21) NO EMERGENCY LIGHT NOTED IN FIRE
 PUMP ROOM.
  
 22) ELECTRICAL CONDUITS NOTED IN STAIR
 # 2. THE STAIR CANNOT BE USED AS A CHASE
 FOR EQUIPMENT.
  
 23) WHY IS THERE NO EXIT SIGN NEAR
 EXTERIOR DOORS NEAR THE MAIL ROOM.
  
 24) SMOKE DETECTOR MISSING FROM BEDROOM
 UNIT B-4.
  
 25) SMOKE DETECTOR MISSING FROM BEDROOM
 UNIT B-3.
  
 26) FOUR FDC'S SHOWN. THIS OFFICE ONLY
 REQUIRES TWO OF THEM.
  
 27) FSP # 2 IS LOCATED IN THE ELEVATOR
 LOBBY. IT SHOULD BE RELOCATED FROM
 THIS LOCALE.
  
 28) CIVIL DRAWINGS SHOW A 6" FIRE LINE.
 THIS LINE IS TWO SMALL.
  
 29) TAMPER SWITCHES REQUIRED ON FIRE
 LINE BACKFLOW DEVICE.
  
 30) PLEASE CLEARLY ILLUSTRATE EXISTING
 FIRE HYDRANT LOCATIONS ON SITE PLAN.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910
 659-8096,EXT.8497

Review Stop I INCOMING/PROCESSING
Rev No 130 Status N Date 2006-10-20 Cont ID  
Sent By adarroug Date 2006-10-20 Time 16:45 Rev Time 0.00
Received By adarroug Date 2006-10-20 Time 16:45 Sent To B
Notes
2006-10-20 16:46:01TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 129 Status N Date 2006-10-05 Cont ID  
Sent By adarroug Date 2006-10-05 Time 14:04 Rev Time 0.00
Received By adarroug Date 2006-10-05 Time 14:04 Sent To B
Notes
2006-10-05 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 128 Status N Date 2006-10-02 Cont ID  
Sent By adarroug Date 2006-10-02 Time 08:55 Rev Time 0.00
Received By adarroug Date 2006-10-02 Time 08:55 Sent To B
Notes
2006-10-02 00:00:00TO "HPISKURA" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 127 Status N Date 2006-09-23 Cont ID  
Sent By adarroug Date 2006-09-23 Time 19:20 Rev Time 0.00
Received By adarroug Date 2006-09-23 Time 19:20 Sent To E
Notes
2006-09-23 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 126 Status N Date 2006-09-09 Cont ID  
Sent By adarroug Date 2006-09-09 Time 16:13 Rev Time 0.00
Received By adarroug Date 2006-09-09 Time 16:13 Sent To P
Notes
2006-09-09 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 125 Status N Date 2006-09-06 Cont ID  
Sent By adarroug Date 2006-09-06 Time 16:55 Rev Time 0.00
Received By adarroug Date 2006-09-06 Time 16:55 Sent To  
Notes
2006-09-06 00:00:00WAITING FOR "COMM" BD-REV

Review Stop I INCOMING/PROCESSING
Rev No 124 Status N Date 2006-08-28 Cont ID  
Sent By pkrauss Date 2006-08-28 Time 11:24 Rev Time 0.00
Received By pkrauss Date 2006-08-28 Time 11:24 Sent To  
Notes
2006-08-28 00:00:00LETTER TO HAROLD PISKURA TO EXTEND TCO.
  

Review Stop I INCOMING/PROCESSING
Rev No 123 Status N Date 2006-08-18 Cont ID  
Sent By adarroug Date 2006-08-18 Time 16:51 Rev Time 0.00
Received By adarroug Date 2006-08-18 Time 16:51 Sent To  
Notes
2006-08-18 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 122 Status N Date 2006-08-16 Cont ID  
Sent By adarroug Date 2006-08-16 Time 11:26 Rev Time 0.00
Received By adarroug Date 2006-08-16 Time 11:26 Sent To M
Notes
2006-08-16 00:00:00TO "M" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 121 Status N Date 2006-08-14 Cont ID  
Sent By adarroug Date 2006-08-14 Time 09:02 Rev Time 0.00
Received By adarroug Date 2006-08-14 Time 09:02 Sent To M
Notes
2006-08-14 00:00:00TO "M" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 120 Status N Date 2006-08-03 Cont ID  
Sent By adarroug Date 2006-08-03 Time 16:54 Rev Time 0.00
Received By adarroug Date 2006-08-03 Time 16:54 Sent To B
Notes
2006-08-03 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 119 Status N Date 2006-08-01 Cont ID  
Sent By adarroug Date 2006-08-01 Time 14:33 Rev Time 0.00
Received By adarroug Date 2006-08-01 Time 14:33 Sent To B
Notes
2006-08-01 00:00:001 "BLDG" REV AND 1 "BLDG" SUBMITTAL TO
 "RBROWN" DESK

Review Stop I INCOMING/PROCESSING
Rev No 118 Status N Date 2006-08-01 Cont ID  
Sent By adarroug Date 2006-08-01 Time 14:31 Rev Time 0.00
Received By adarroug Date 2006-08-01 Time 14:31 Sent To E
Notes
2006-08-01 00:00:00TO "DPALMER" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 117 Status N Date 2006-07-24 Cont ID  
Sent By adarroug Date 2006-07-24 Time 10:29 Rev Time 0.00
Received By adarroug Date 2006-07-24 Time 10:29 Sent To M
Notes
2006-07-24 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 116 Status N Date 2006-07-15 Cont ID  
Sent By adarroug Date 2006-07-15 Time 09:38 Rev Time 0.00
Received By adarroug Date 2006-07-15 Time 09:38 Sent To M
Notes
2006-07-15 00:00:00TO "M" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 115 Status N Date 2006-07-13 Cont ID  
Sent By adarroug Date 2006-07-13 Time 16:34 Rev Time 0.00
Received By adarroug Date 2006-07-13 Time 16:34 Sent To M
Notes
2006-07-13 00:00:00TO "M" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 114 Status N Date 2006-07-13 Cont ID  
Sent By adarroug Date 2006-07-13 Time 14:45 Rev Time 0.00
Received By adarroug Date 2006-07-13 Time 14:45 Sent To B
Notes
2006-07-13 00:00:00REV. TAKEN FROM "COMM" BD#56 AND ROUTED
 TO "RBROWN" DESKADARROUGH

Review Stop I INCOMING/PROCESSING
Rev No 113 Status N Date 2006-07-07 Cont ID  
Sent By adarroug Date 2006-07-07 Time 11:28 Rev Time 0.00
Received By adarroug Date 2006-07-07 Time 11:28 Sent To M
Notes
2006-07-07 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 112 Status N Date 2006-07-06 Cont ID  
Sent By adarroug Date 2006-07-06 Time 09:49 Rev Time 0.00
Received By adarroug Date 2006-07-06 Time 09:49 Sent To Z
Notes
2006-07-06 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 111 Status N Date 2006-07-05 Cont ID  
Sent By adarroug Date 2006-07-05 Time 10:16 Rev Time 0.00
Received By adarroug Date 2006-07-05 Time 10:16 Sent To B
Notes
2006-07-05 00:00:00TO "RBROWN" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 110 Status N Date 2006-06-30 Cont ID  
Sent By adarroug Date 2006-05-13 Time 11:49 Rev Time 0.00
Received By adarroug Date 2006-05-13 Time 11:49 Sent To FIRE
Notes
2006-06-30 00:00:00TO "F" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 109 Status N Date 2006-06-26 Cont ID  
Sent By adarroug Date 2006-06-26 Time 11:00 Rev Time 0.00
Received By adarroug Date 2006-06-26 Time 11:00 Sent To B
Notes
2006-06-26 00:00:00TO "RBROWN" DESK/SUBMITTAL
 TCO PLAN RE-ROUTED TO HAROLD PISKURA
 6/26/06
  
  

Review Stop I INCOMING/PROCESSING
Rev No 108 Status N Date 2006-06-26 Cont ID  
Sent By adarroug Date 2006-06-26 Time 10:55 Rev Time 0.00
Received By adarroug Date 2006-06-26 Time 10:55 Sent To P
Notes
2006-06-26 00:00:00TO "P" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 107 Status N Date 2006-06-23 Cont ID  
Sent By adarroug Date 2006-06-23 Time 16:15 Rev Time 0.00
Received By adarroug Date 2006-06-23 Time 16:15 Sent To  
Notes
2006-07-05 00:00:00TO "COMM" BD#4
2006-06-23 00:00:00WAITING FOR "COMM" BD-REV

Review Stop I INCOMING/PROCESSING
Rev No 106 Status N Date 2006-06-21 Cont ID  
Sent By adarroug Date 2006-06-21 Time 12:36 Rev Time 0.00
Received By adarroug Date 2006-06-21 Time 12:36 Sent To B
Notes
2006-06-21 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 105 Status N Date 2006-06-14 Cont ID  
Sent By adarroug Date 2006-06-14 Time 15:35 Rev Time 0.00
Received By adarroug Date 2006-06-14 Time 15:35 Sent To M
Notes
2006-06-14 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 104 Status N Date 2006-05-15 Cont ID  
Sent By adarroug Date 2006-05-15 Time 14:59 Rev Time 0.00
Received By adarroug Date 2006-05-15 Time 14:59 Sent To B
Notes
2006-05-15 00:00:00TO "RBROWN" DESK/ 2 SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 103 Status N Date 2006-05-11 Cont ID  
Sent By adarroug Date 2006-05-11 Time 12:51 Rev Time 0.00
Received By adarroug Date 2006-05-11 Time 12:51 Sent To Z
Notes
2006-05-11 00:00:00TO "Z" BOX-REV

Review Stop I INCOMING/PROCESSING
Rev No 102 Status N Date 2006-05-03 Cont ID  
Sent By adarroug Date 2006-05-03 Time 09:44 Rev Time 0.00
Received By adarroug Date 2006-05-03 Time 09:44 Sent To  
Notes
2006-05-24 00:00:00TO "COMM" BD#33
2006-05-03 00:00:00WAITING FOR "COMM" BD-REV

Review Stop I INCOMING/PROCESSING
Rev No 101 Status N Date 2006-04-29 Cont ID  
Sent By adarroug Date 2006-04-29 Time 15:01 Rev Time 0.00
Received By adarroug Date 2006-04-29 Time 15:00 Sent To B
Notes
2006-04-29 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 100 Status N Date 2006-04-24 Cont ID  
Sent By adarroug Date 2006-04-24 Time 16:37 Rev Time 0.00
Received By adarroug Date 2006-04-24 Time 16:37 Sent To B
Notes
2006-04-24 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 99 Status N Date 2006-04-24 Cont ID  
Sent By adarroug Date 2006-04-24 Time 16:31 Rev Time 0.00
Received By adarroug Date 2006-04-24 Time 16:31 Sent To Z
Notes
2006-04-24 00:00:00TO "Z" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 98 Status N Date 2006-04-18 Cont ID  
Sent By adarroug Date 2006-04-18 Time 14:27 Rev Time 0.00
Received By adarroug Date 2006-04-18 Time 14:27 Sent To  
Notes
2006-05-04 00:00:00TO "COMM" BD#14-REV
2006-04-18 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 97 Status N Date 2006-04-14 Cont ID  
Sent By adarroug Date 2006-04-14 Time 08:59 Rev Time 0.00
Received By adarroug Date 2006-04-14 Time 08:59 Sent To  
Notes
2006-05-03 00:00:00TO "COMM" BD#56-REV
2006-04-14 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 96 Status N Date 2006-03-24 Cont ID  
Sent By dpalmer Date 2006-03-24 Time 18:15 Rev Time 0.00
Received By dpalmer Date 2006-03-24 Time 18:15 Sent To B
Notes
2006-03-24 00:00:00TO RB'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 95 Status N Date 2006-03-01 Cont ID  
Sent By adarroug Date 2006-03-01 Time 13:04 Rev Time 0.00
Received By adarroug Date 2006-03-01 Time 13:04 Sent To E
Notes
2006-03-01 00:00:00TO "F" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 94 Status N Date 2006-03-01 Cont ID  
Sent By adarroug Date 2006-03-01 Time 12:56 Rev Time 0.00
Received By adarroug Date 2006-03-01 Time 12:56 Sent To M
Notes
2006-03-01 00:00:00TO "M" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 93 Status N Date 2006-02-28 Cont ID  
Sent By adarroug Date 2006-02-28 Time 18:17 Rev Time 0.00
Received By adarroug Date 2006-02-28 Time 18:17 Sent To M
Notes
2006-02-28 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 92 Status N Date 2006-02-16 Cont ID  
Sent By adarroug Date 2006-02-16 Time 08:35 Rev Time 0.00
Received By adarroug Date 2006-02-16 Time 08:35 Sent To B
Notes
2006-02-16 00:00:00TO "RBROWN" DESK/SUB

Review Stop I INCOMING/PROCESSING
Rev No 91 Status N Date 2006-02-03 Cont ID  
Sent By adarroug Date 2006-02-03 Time 12:45 Rev Time 0.00
Received By adarroug Date 2006-02-03 Time 12:45 Sent To P
Notes
2006-02-03 00:00:00TO "P" BOX/ 2 SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 90 Status N Date 2006-02-02 Cont ID  
Sent By adarroug Date 2006-02-02 Time 18:59 Rev Time 0.00
Received By adarroug Date 2006-02-02 Time 18:57 Sent To Z
Notes
2006-02-02 00:00:00TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 89 Status N Date 2006-01-22 Cont ID  
Sent By adarroug Date 2006-01-22 Time 11:12 Rev Time 0.00
Received By adarroug Date 2006-01-22 Time 11:12 Sent To M
Notes
2006-01-22 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 88 Status N Date 2006-01-18 Cont ID  
Sent By adarroug Date 2006-01-18 Time 16:43 Rev Time 0.00
Received By adarroug Date 2006-01-18 Time 16:43 Sent To  
Notes
2006-05-26 00:00:00TO "RBROWN" DESK FROM "COMM" BD #1
2006-02-09 00:00:00TO "COMM" BD#1-REV
2006-01-18 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 87 Status N Date 2006-01-13 Cont ID  
Sent By adarroug Date 2006-01-13 Time 15:48 Rev Time 0.00
Received By adarroug Date 2006-01-13 Time 15:48 Sent To B
Notes
2006-01-13 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 86 Status N Date 2005-12-29 Cont ID  
Sent By adarroug Date 2005-12-29 Time 08:26 Rev Time 0.00
Received By adarroug Date 2005-12-29 Time 08:26 Sent To E
Notes
2005-12-29 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 85 Status N Date 2005-12-13 Cont ID  
Sent By adarroug Date 2005-12-13 Time 11:34 Rev Time 0.00
Received By adarroug Date 2005-12-13 Time 11:34 Sent To M
Notes
2005-12-13 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 84 Status N Date 2005-12-07 Cont ID  
Sent By adarroug Date 2005-12-07 Time 09:25 Rev Time 0.00
Received By adarroug Date 2005-12-07 Time 09:25 Sent To M
Notes
2005-12-07 00:00:00TO "M" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 83 Status N Date 2005-12-06 Cont ID  
Sent By adarroug Date 2005-12-06 Time 16:05 Rev Time 0.00
Received By adarroug Date 2005-12-06 Time 16:05 Sent To  
Notes
2006-01-03 00:00:00TO "COMM" BD#21
2005-12-06 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 82 Status N Date 2005-11-18 Cont ID  
Sent By adarroug Date 2005-11-18 Time 16:28 Rev Time 0.00
Received By adarroug Date 2005-11-18 Time 16:28 Sent To  
Notes
2005-12-06 00:00:00TO "COMM" BD#60
2005-11-18 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 81 Status N Date 2005-11-15 Cont ID  
Sent By adarroug Date 2005-11-15 Time 13:33 Rev Time 0.00
Received By adarroug Date 2005-11-15 Time 13:33 Sent To B
Notes
2005-11-15 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 80 Status N Date 2005-10-11 Cont ID  
Sent By adarroug Date 2005-10-11 Time 13:53 Rev Time 0.00
Received By adarroug Date 2005-10-11 Time 13:53 Sent To B
Notes
2005-10-11 00:00:00TO "RBROWN" DESK/3 SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 79 Status N Date 2005-10-05 Cont ID  
Sent By adarroug Date 2005-10-05 Time 11:16 Rev Time 0.00
Received By adarroug Date 2005-10-05 Time 11:16 Sent To B
Notes
2005-10-05 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 78 Status N Date 2005-09-13 Cont ID  
Sent By adarroug Date 2005-09-13 Time 09:56 Rev Time 0.00
Received By adarroug Date 2005-09-13 Time 09:56 Sent To  
Notes
2005-09-13 00:00:00TO "COMM" BD#17

Review Stop I INCOMING/PROCESSING
Rev No 77 Status N Date 2005-08-25 Cont ID  
Sent By adarroug Date 2005-08-25 Time 09:12 Rev Time 0.00
Received By adarroug Date 2005-08-25 Time 09:12 Sent To M
Notes
2005-08-25 00:00:00TO "HMOSER"/REV

Review Stop I INCOMING/PROCESSING
Rev No 76 Status N Date 2005-08-18 Cont ID  
Sent By adarroug Date 2005-08-18 Time 17:47 Rev Time 0.00
Received By adarroug Date 2005-08-18 Time 17:47 Sent To B
Notes
2005-08-18 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 75 Status N Date 2005-08-18 Cont ID  
Sent By adarroug Date 2005-08-18 Time 15:49 Rev Time 0.00
Received By adarroug Date 2005-08-18 Time 15:49 Sent To M
Notes
2005-08-18 00:00:00TO "M" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 74 Status N Date 2005-08-03 Cont ID  
Sent By adarroug Date 2005-08-03 Time 11:17 Rev Time 0.00
Received By adarroug Date 2005-08-03 Time 11:17 Sent To B
Notes
2005-08-03 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 73 Status N Date 2005-07-27 Cont ID  
Sent By adarroug Date 2005-07-27 Time 09:53 Rev Time 0.00
Received By adarroug Date 2005-07-27 Time 09:53 Sent To  
Notes
2005-07-27 00:00:00TO "COMM" BD#64

Review Stop I INCOMING/PROCESSING
Rev No 72 Status N Date 2005-07-19 Cont ID  
Sent By adarroug Date 2005-07-19 Time 13:54 Rev Time 0.00
Received By adarroug Date 2005-07-19 Time 13:54 Sent To  
Notes
2005-07-20 00:00:00TO "COMM" BD#60
2005-07-19 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 71 Status N Date 2005-07-19 Cont ID  
Sent By adarroug Date 2005-07-19 Time 08:45 Rev Time 0.00
Received By adarroug Date 2005-07-19 Time 08:45 Sent To B
Notes
2005-07-19 00:00:00TO "RBROWN" DESK/ 2 SUMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 70 Status N Date 2005-07-08 Cont ID  
Sent By adarroug Date 2005-07-08 Time 11:25 Rev Time 0.00
Received By adarroug Date 2005-07-08 Time 11:25 Sent To B
Notes
2005-07-08 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 69 Status N Date 2005-07-08 Cont ID  
Sent By adarroug Date 2005-07-08 Time 11:23 Rev Time 0.00
Received By adarroug Date 2005-07-08 Time 11:23 Sent To B
Notes
2005-07-08 00:00:00TO "RBROWN" DESK/3 SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 68 Status N Date 2005-07-08 Cont ID  
Sent By adarroug Date 2005-07-08 Time 11:20 Rev Time 0.00
Received By adarroug Date 2005-07-08 Time 11:20 Sent To P
Notes
2005-07-08 00:00:00TO "P" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 67 Status N Date 2005-06-30 Cont ID  
Sent By adarroug Date 2005-06-30 Time 16:23 Rev Time 0.00
Received By adarroug Date 2005-06-30 Time 16:23 Sent To B
Notes
2005-06-30 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 66 Status N Date 2005-06-29 Cont ID  
Sent By adarroug Date 2005-06-29 Time 10:19 Rev Time 0.00
Received By adarroug Date 2005-06-29 Time 10:18 Sent To B
Notes
2005-06-29 00:00:00TO "RBROWN" DESK/3 BLDG SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 65 Status N Date 2005-06-22 Cont ID  
Sent By adarroug Date 2005-06-22 Time 10:47 Rev Time 0.00
Received By adarroug Date 2005-06-22 Time 10:47 Sent To  
Notes
2005-06-27 00:00:00TO "COMM" BD#12
2005-06-22 00:00:00WAITING FOR SPACE ON "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 64 Status N Date 2005-06-21 Cont ID  
Sent By adarroug Date 2005-06-21 Time 14:35 Rev Time 0.00
Received By adarroug Date 2005-06-21 Time 14:35 Sent To FIRE
Notes
2005-06-21 00:00:00TO "NMCRAY" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 63 Status N Date 2005-06-20 Cont ID  
Sent By shill Date 2005-06-20 Time 15:29 Rev Time 0.00
Received By shill Date 2005-06-20 Time 15:29 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 62 Status N Date 2005-06-20 Cont ID  
Sent By shill Date 2005-06-20 Time 15:01 Rev Time 0.00
Received By shill Date 2005-06-20 Time 15:01 Sent To B
Notes
2005-06-20 00:00:00TO RB DESK

Review Stop I INCOMING/PROCESSING
Rev No 61 Status N Date 2005-06-08 Cont ID  
Sent By shill Date 2005-06-08 Time 10:55 Rev Time 0.00
Received By shill Date 2005-06-08 Time 10:55 Sent To B
Notes
2005-06-08 00:00:00TO RB DESK

Review Stop I INCOMING/PROCESSING
Rev No 60 Status   Date 2005-05-31 Cont ID  
Sent By adarroug Date 2005-05-31 Time 13:34 Rev Time 0.00
Received By adarroug Date 2005-05-31 Time 13:34 Sent To B
Notes
2005-05-31 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 59 Status N Date 2005-05-24 Cont ID  
Sent By adarroug Date 2005-05-24 Time 17:42 Rev Time 0.00
Received By adarroug Date 2005-05-24 Time 17:42 Sent To B
Notes
2005-05-24 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 58 Status N Date 2005-05-19 Cont ID  
Sent By adarroug Date 2005-05-19 Time 12:47 Rev Time 0.00
Received By adarroug Date 2005-05-19 Time 12:47 Sent To B
Notes
2005-05-19 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 57 Status N Date 2005-05-19 Cont ID  
Sent By adarroug Date 2005-05-19 Time 12:46 Rev Time 0.00
Received By adarroug Date 2005-05-19 Time 12:46 Sent To B
Notes
2005-05-19 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 56 Status N Date 2005-05-19 Cont ID  
Sent By adarroug Date 2005-05-19 Time 12:43 Rev Time 0.00
Received By adarroug Date 2005-05-19 Time 12:43 Sent To B
Notes
2005-05-19 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 55 Status N Date 2005-05-17 Cont ID  
Sent By adarroug Date 2005-05-17 Time 11:01 Rev Time 0.00
Received By adarroug Date 2005-05-17 Time 11:01 Sent To FIRE
Notes
2005-05-17 00:00:00TO "F" BOX

Review Stop I INCOMING/PROCESSING
Rev No 54 Status N Date 2005-05-12 Cont ID  
Sent By adarroug Date 2005-05-12 Time 16:24 Rev Time 0.00
Received By adarroug Date 2005-05-12 Time 16:24 Sent To FIRE
Notes
2005-05-12 00:00:00TO "F" BOX

Review Stop I INCOMING/PROCESSING
Rev No 53 Status N Date 2005-05-12 Cont ID  
Sent By adarroug Date 2005-05-12 Time 16:22 Rev Time 0.00
Received By adarroug Date 2005-05-12 Time 16:22 Sent To B
Notes
2005-05-12 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 52 Status N Date 2005-05-06 Cont ID  
Sent By adarroug Date 2005-05-06 Time 16:06 Rev Time 0.00
Received By adarroug Date 2005-05-06 Time 16:06 Sent To B
Notes
2005-05-06 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 51 Status N Date 2005-05-06 Cont ID  
Sent By adarroug Date 2005-05-06 Time 16:05 Rev Time 0.00
Received By adarroug Date 2005-05-06 Time 16:05 Sent To B
Notes
2005-05-06 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 50 Status N Date 2005-05-06 Cont ID  
Sent By adarroug Date 2005-05-06 Time 16:04 Rev Time 0.00
Received By adarroug Date 2005-05-06 Time 16:04 Sent To B
Notes
2005-05-06 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 49 Status N Date 2005-05-06 Cont ID  
Sent By adarroug Date 2005-05-06 Time 16:03 Rev Time 0.00
Received By adarroug Date 2005-05-06 Time 16:03 Sent To B
Notes
2005-05-06 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 48 Status N Date 2005-05-03 Cont ID  
Sent By adarroug Date 2005-05-03 Time 13:40 Rev Time 0.00
Received By adarroug Date 2005-05-03 Time 13:40 Sent To B
Notes
2005-05-03 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 47 Status N Date 2005-04-29 Cont ID  
Sent By adarroug Date 2005-04-29 Time 08:54 Rev Time 0.00
Received By adarroug Date 2005-04-29 Time 08:54 Sent To B
Notes
2005-04-29 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 46 Status N Date 2005-04-29 Cont ID  
Sent By adarroug Date 2005-04-29 Time 08:53 Rev Time 0.00
Received By adarroug Date 2005-04-29 Time 08:53 Sent To B
Notes
2005-04-29 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 45 Status N Date 2005-04-29 Cont ID  
Sent By adarroug Date 2005-04-29 Time 08:52 Rev Time 0.00
Received By adarroug Date 2005-04-29 Time 08:52 Sent To B
Notes
2005-04-29 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 44 Status N Date 2005-04-29 Cont ID  
Sent By adarroug Date 2005-04-29 Time 08:52 Rev Time 0.00
Received By adarroug Date 2005-04-29 Time 08:52 Sent To B
Notes
2005-04-29 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 43 Status N Date 2005-04-28 Cont ID  
Sent By adarroug Date 2005-04-28 Time 10:53 Rev Time 0.00
Received By adarroug Date 2005-04-28 Time 10:53 Sent To B
Notes
2005-04-28 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 42 Status N Date 2005-04-28 Cont ID  
Sent By adarroug Date 2005-04-28 Time 10:52 Rev Time 0.00
Received By adarroug Date 2005-04-28 Time 10:52 Sent To B
Notes
2005-04-28 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 41 Status N Date 2005-04-25 Cont ID  
Sent By adarroug Date 2005-04-25 Time 11:24 Rev Time 0.00
Received By adarroug Date 2005-04-25 Time 11:24 Sent To ENG
Notes
2005-04-25 00:00:00TO "MAMINI" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 40 Status N Date 2005-04-15 Cont ID  
Sent By adarroug Date 2005-04-15 Time 15:26 Rev Time 0.00
Received By adarroug Date 2005-04-15 Time 15:26 Sent To  
Notes
2005-04-15 00:00:00TO "COMM" BD#38 W/ PLANS THAT CAME IN ON
 4/6/05ADARROUGH

Review Stop I INCOMING/PROCESSING
Rev No 39 Status N Date 2005-04-12 Cont ID  
Sent By adarroug Date 2005-04-12 Time 17:26 Rev Time 0.00
Received By adarroug Date 2005-04-12 Time 17:26 Sent To B
Notes
2005-04-12 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 38 Status N Date 2005-04-08 Cont ID  
Sent By adarroug Date 2005-04-08 Time 08:25 Rev Time 0.00
Received By adarroug Date 2005-04-08 Time 08:25 Sent To  
Notes
2005-04-08 00:00:00TO "COMM" BD#38

Review Stop I INCOMING/PROCESSING
Rev No 37 Status N Date 2005-04-04 Cont ID  
Sent By adarroug Date 2005-04-04 Time 16:40 Rev Time 0.00
Received By adarroug Date 2005-04-04 Time 16:40 Sent To B
Notes
2005-04-04 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 36 Status N Date 2005-03-29 Cont ID  
Sent By adarroug Date 2005-03-29 Time 11:27 Rev Time 0.00
Received By adarroug Date 2005-03-29 Time 11:27 Sent To M
Notes
2005-03-29 00:00:00TO "PKRAUSS" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 35 Status N Date 2005-03-25 Cont ID  
Sent By adarroug Date 2005-03-25 Time 09:20 Rev Time 0.00
Received By adarroug Date 2005-03-25 Time 09:20 Sent To B
Notes
2005-03-25 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 34 Status N Date 2005-03-21 Cont ID  
Sent By adarroug Date 2005-03-21 Time 16:50 Rev Time 0.00
Received By adarroug Date 2005-03-21 Time 16:50 Sent To B
Notes
2005-03-21 00:00:00TO "RBROWN"DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 33 Status N Date 2005-03-17 Cont ID  
Sent By adarroug Date 2005-03-17 Time 09:50 Rev Time 0.00
Received By adarroug Date 2005-03-17 Time 09:50 Sent To B
Notes
2005-03-17 00:00:00TO "RBROWN"DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 32 Status N Date 2005-03-15 Cont ID  
Sent By adarroug Date 2005-03-15 Time 14:07 Rev Time 0.00
Received By adarroug Date 2005-03-15 Time 14:07 Sent To B
Notes
2005-03-15 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 31 Status N Date 2005-03-15 Cont ID  
Sent By adarroug Date 2005-03-15 Time 14:01 Rev Time 0.00
Received By adarroug Date 2005-03-15 Time 14:01 Sent To B
Notes
2005-03-15 00:00:00TO "RBROWN"DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 30 Status N Date 2005-03-11 Cont ID  
Sent By adarroug Date 2005-03-11 Time 10:33 Rev Time 0.00
Received By adarroug Date 2005-03-11 Time 10:33 Sent To B
Notes
2005-03-11 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 29 Status N Date 2005-02-25 Cont ID  
Sent By adarroug Date 2005-02-25 Time 15:34 Rev Time 0.00
Received By adarroug Date 2005-02-25 Time 15:34 Sent To B
Notes
2005-02-25 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 28 Status N Date 2005-02-25 Cont ID  
Sent By adarroug Date 2005-02-25 Time 14:56 Rev Time 0.00
Received By adarroug Date 2005-02-25 Time 14:56 Sent To B
Notes
2005-02-25 00:00:00TO "RBROWN"DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 27 Status N Date 2005-02-25 Cont ID  
Sent By adarroug Date 2005-02-18 Time 14:55 Rev Time 0.00
Received By adarroug Date 2005-02-18 Time 08:35 Sent To B
Notes
2005-02-18 00:00:00TO RBROWN DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 26 Status N Date 2005-02-14 Cont ID  
Sent By adarroug Date 2005-02-14 Time 15:33 Rev Time 0.00
Received By adarroug Date 2005-02-18 Time 08:35 Sent To B
Notes
2005-02-14 00:00:00TO RBROWN DESK

Review Stop I INCOMING/PROCESSING
Rev No 25 Status N Date 2005-02-10 Cont ID  
Sent By mjacobs Date 2005-02-10 Time 10:31 Rev Time 0.00
Received By mjacobs Date 2005-02-10 Time 10:31 Sent To B
Notes
2005-02-10 00:00:00TO "RB" DESK/SUBMITTALS.

Review Stop I INCOMING/PROCESSING
Rev No 24 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By pschmitz Date 2005-02-05 Time 06:45 Sent To  
Notes
2005-02-05 00:00:00REVISION,P-TRAPS AT 30" TRANSFERE SLAB.

Review Stop I INCOMING/PROCESSING
Rev No 23 Status N Date 2005-02-04 Cont ID  
Sent By adarroug Date 2005-02-04 Time 14:44 Rev Time 0.00
Received By adarroug Date 2005-02-04 Time 14:44 Sent To B
Notes
2005-02-04 00:00:00TO RBROWN DESK

Review Stop I INCOMING/PROCESSING
Rev No 22 Status N Date 2005-02-04 Cont ID  
Sent By adarroug Date 2005-02-04 Time 14:16 Rev Time 0.00
Received By adarroug Date 2005-02-04 Time 14:16 Sent To B
Notes
2005-02-04 00:00:00TO RBROWN DESK

Review Stop I INCOMING/PROCESSING
Rev No 21 Status N Date 2005-02-04 Cont ID  
Sent By adarroug Date 2005-02-04 Time 14:10 Rev Time 0.00
Received By adarroug Date 2005-02-04 Time 14:10 Sent To B
Notes
2005-02-04 00:00:00TO RBROWN DESK

Review Stop I INCOMING/PROCESSING
Rev No 20 Status N Date 2005-02-04 Cont ID  
Sent By adarroug Date 2005-02-04 Time 14:22 Rev Time 0.00
Received By adarroug Date 2005-02-04 Time 14:22 Sent To B
Notes
2005-02-04 00:00:00TO "F"BOX/SUBMITTAL
 TO R.BROWN DESK

Review Stop I INCOMING/PROCESSING
Rev No 19 Status N Date 2005-01-21 Cont ID  
Sent By mjacobs Date 2005-01-21 Time 16:43 Rev Time 0.00
Received By mjacobs Date 2005-01-21 Time 16:43 Sent To B
Notes
2005-01-21 00:00:00TO "RB" DESK/SUBMITTALS.

Review Stop I INCOMING/PROCESSING
Rev No 18 Status N Date 2005-01-14 Cont ID  
Sent By mjacobs Date 2005-01-14 Time 15:31 Rev Time 0.00
Received By mjacobs Date 2005-01-14 Time 15:31 Sent To B
Notes
2005-01-14 00:00:00TO "RB" DESK./SUBMITTALS.

Review Stop I INCOMING/PROCESSING
Rev No 17 Status N Date 2005-01-11 Cont ID  
Sent By mjacobs Date 2005-01-11 Time 16:07 Rev Time 0.00
Received By mjacobs Date 2005-01-11 Time 16:07 Sent To P
Notes
2005-01-11 00:00:00TO "P" BOX./SUBMITTAL.

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2004-12-20 Cont ID  
Sent By mjacobs Date 2004-12-20 Time 14:10 Rev Time 0.00
Received By mjacobs Date 2004-12-20 Time 14:09 Sent To B
Notes
2004-12-20 00:00:00SENT TO "RB" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2004-12-20 Cont ID  
Sent By mjacobs Date 2004-12-20 Time 13:29 Rev Time 0.00
Received By mjacobs Date 2004-12-20 Time 13:29 Sent To P
Notes
2004-12-20 00:00:00SENT TO "P" BOX./REV.

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2004-12-14 Cont ID  
Sent By mjacobs Date 2004-12-14 Time 10:31 Rev Time 0.00
Received By mjacobs Date 2004-12-14 Time 10:31 Sent To B
Notes
2004-12-14 00:00:00SENT TO "RB" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2004-11-24 Cont ID  
Sent By mjacobs Date 2004-11-24 Time 16:13 Rev Time 0.00
Received By mjacobs Date 2004-11-24 Time 16:13 Sent To P
Notes
2004-11-24 00:00:00SENT TO "P" BOX./REV.

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2004-11-22 Cont ID  
Sent By mjacobs Date 2004-12-20 Time 14:11 Rev Time  
Received By mjacobs Date 2004-11-22 Time 08:07 Sent To  
Notes
2004-11-22 00:00:00SENT TO COMM BD#35/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2004-11-22 Cont ID  
Sent By mjacobs Date 2004-11-22 Time 08:00 Rev Time 0.00
Received By mjacobs Date 2004-11-22 Time 08:01 Sent To B
Notes
2004-11-22 00:00:00SENT TO RB DESK

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2004-11-15 Cont ID  
Sent By csiegber Date 2004-11-15 Time 09:25 Rev Time 0.00
Received By csiegber Date 2004-11-15 Time 09:25 Sent To B
Notes
2004-11-15 00:00:00TO RB DESK/2 SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2004-11-02 Cont ID  
Sent By csiegber Date 2004-11-02 Time 16:40 Rev Time 0.00
Received By csiegber Date 2004-11-02 Time 16:40 Sent To B
Notes
2004-11-02 00:00:00TO RB DESK/SUBMITTAL
 WATERPROOFING-THORSEAL 0002-07900-0
 WATERPROOFING BENTONITE 0001-07900-0
 CONCRETE SLAB JOINTS 0004-03100-0
 CONCRETE MIXDESIGNS 0001-03300-0
 CONCRETE REINFORCEMENT 0001-03200-1

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2004-10-05 Cont ID  
Sent By csiegber Date 2004-10-05 Time 11:10 Rev Time 0.00
Received By csiegber Date 2004-10-05 Time 11:10 Sent To B
Notes
2004-10-05 00:00:00TO RB DESK/REV
 PER LETTER ATTACHED/HURRICAN HELP

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-08-26 Cont ID  
Sent By csiegber Date 2004-08-26 Time 10:27 Rev Time 0.00
Received By csiegber Date 2004-08-26 Time 10:27 Sent To B
Notes
2004-08-26 00:00:00TO RB DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-06-03 Cont ID  
Sent By csiegber Date 2004-06-03 Time 15:14 Rev Time 0.00
Received By csiegber Date 2004-06-03 Time 15:14 Sent To  
Notes
2004-06-03 00:00:00TO COMM BD#9

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-03-12 Cont ID  
Sent By csiegber Date 2004-03-12 Time 10:01 Rev Time 0.00
Received By csiegber Date 2004-03-12 Time 10:01 Sent To  
Notes
2004-03-12 00:00:00TO COMM BD#3

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-02-06 Cont ID  
Sent By csiegber Date 2004-02-06 Time 12:43 Rev Time 0.00
Received By csiegber Date 2004-02-06 Time 12:43 Sent To  
Notes
2004-02-06 00:00:00TO COMM BD#26 INCLUDING Z

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-24 Cont ID  
Sent By csiegber Date 2003-10-24 Time 14:05 Rev Time 0.00
Received By csiegber Date 2003-10-24 Time 14:05 Sent To  
Notes
2003-10-24 00:00:00TO COMM BD#51/PLANS ON TO SHELF RIGHT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-10-17 Cont ID  
Sent By csiegber Date 2003-10-16 Time 16:41 Rev Time 0.00
Received By csiegber Date 2003-10-16 Time 16:41 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-05 Cont ID  
Sent By shernand Date 2003-05-05 Time 13:04 Rev Time 0.00
Received By shernand Date 2003-05-05 Time 13:04 Sent To  
Notes
2003-05-05 00:00:00COMM BOARD #24.PLANS NEXT TO CONF ROOM

Review Stop M MECHANICAL (A/C)
Rev No 27 Status P Date 2006-09-12 Cont ID  
Sent By pkrauss Date 2006-09-12 Time 11:43 Rev Time 0.00
Received By pkrauss Date 2006-09-12 Time 11:43 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 26 Status P Date 2006-08-25 Cont ID  
Sent By pkrauss Date 2006-08-25 Time 09:16 Rev Time 0.00
Received By pkrauss Date 2006-08-25 Time 09:16 Sent To  
Notes
2006-08-25 00:00:00REVISED SHEET M1.03 -
 1) REVISED THE INSULATION JACKET FOR THE
 MUFFLER TO THE EMERGENCY GENERATOR.
  
 2) REVISED THE BUSINESS CENTER ROOM,
 REMOVED DOOR TO ELIMATE THE RETURN AIR
 DUCT.

Review Stop M MECHANICAL (A/C)
Rev No 25 Status F Date 2006-08-18 Cont ID  
Sent By pkrauss Date 2006-08-18 Time 14:11 Rev Time 0.00
Received By pkrauss Date 2006-08-18 Time 14:07 Sent To  
Notes
2006-08-18 00:00:00DENIED:
 CODE SPECIFICALLY STATES MAXIMUM LENGTH
 25FT WITH REDUCTIONS FOR 90 DEGREE BENDS
 WITH THE EXCEPTION "PER MANUFACTURER'S
 SPECIFICATIONS", OR SHAFT ENCLOSURE.
 THIS SUBMITTAL DOES NOT COMPLY WITH ANY
 OF THE OPTIONS ALLOWED BY CODE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719 OR
 E-MAIL [email protected].
  

Review Stop M MECHANICAL (A/C)
Rev No 24 Status P Date 2006-07-10 Cont ID  
Sent By tgordon Date 2006-07-10 Time 08:26 Rev Time 0.45
Received By tgordon Date 2006-07-10 Time 08:26 Sent To  
Notes
2006-07-10 00:00:00REVISION TO MECH. PLANS PAGE M4.01 AND
 M7.01 .

Review Stop M MECHANICAL (A/C)
Rev No 23 Status P Date 2006-06-19 Cont ID  
Sent By hmoser Date 2006-06-19 Time 11:20 Rev Time 0.00
Received By hmoser Date 2006-06-19 Time 10:55 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 22 Status P Date 2006-06-19 Cont ID  
Sent By hmoser Date 2006-06-19 Time 10:35 Rev Time 0.00
Received By hmoser Date 2006-06-19 Time 10:35 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 21 Status P Date 2006-06-16 Cont ID  
Sent By tgordon Date 2006-06-16 Time 09:00 Rev Time 1.00
Received By tgordon Date 2006-06-16 Time 09:00 Sent To  
Notes
2006-06-16 00:00:00MECH. REVISION TO PAGE M1.03 & M2.05 .

Review Stop M MECHANICAL (A/C)
Rev No 20 Status P Date 2006-06-02 Cont ID  
Sent By tgordon Date 2006-06-02 Time 16:05 Rev Time 0.30
Received By tgordon Date 2006-06-02 Time 16:04 Sent To  
Notes
2006-06-02 00:00:00REVISION TO MECH. PLAN PAGE M1.03 .

Review Stop M MECHANICAL (A/C)
Rev No 19 Status F Date 2006-04-12 Cont ID  
Sent By hmoser Date 2006-04-12 Time 10:46 Rev Time 0.00
Received By hmoser Date 2006-04-12 Time 10:45 Sent To  
Notes
2006-04-12 00:00:00PLAN DENIED
 1) REVISON MUST BE SIGNED AND SEALED.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 18 Status N Date 2006-03-12 Cont ID  
Sent By hmoser Date 2006-03-12 Time 09:26 Rev Time 0.00
Received By hmoser Date 2006-03-12 Time 09:26 Sent To P
Notes
2006-03-12 00:00:00ALL LETTERS PROVIED ARE FOR PLUNBING NOT
 MECHANICAL.3/12/05 HM.

Review Stop M MECHANICAL (A/C)
Rev No 17 Status P Date 2006-03-02 Cont ID  
Sent By pkrauss Date 2006-03-02 Time 06:35 Rev Time 0.00
Received By pkrauss Date 2006-03-02 Time 06:35 Sent To  
Notes
2006-03-02 00:00:00PROVISO:REVISED SHEETS M2.06 & M2.07
  
 PLANS INDICATE NO COMBUSTIBLES ALLOWED
 IN THE RETURN AIR PLENUM.PLEASE NOTE,
 THIS INCLUDES THE DOOR AND THE DOOR
 FRAME.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 16 Status P Date 2006-02-10 Cont ID  
Sent By hmoser Date 2006-02-10 Time 07:34 Rev Time 0.00
Received By hmoser Date 2006-02-10 Time 07:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 15 Status P Date 2006-02-03 Cont ID  
Sent By hmoser Date 2006-02-03 Time 13:23 Rev Time 0.00
Received By hmoser Date 2006-02-03 Time 13:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 14 Status P Date 2006-01-24 Cont ID  
Sent By pkrauss Date 2006-01-24 Time 15:16 Rev Time 0.00
Received By pkrauss Date 2006-01-24 Time 13:59 Sent To  
Notes
2006-01-25 00:00:00REVISED SHEETS M1.09, M1.10, M4.02.

Review Stop M MECHANICAL (A/C)
Rev No 13 Status P Date 2006-01-05 Cont ID  
Sent By hmoser Date 2006-01-05 Time 11:12 Rev Time 0.00
Received By hmoser Date 2006-01-05 Time 11:12 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 12 Status P Date 2005-12-29 Cont ID  
Sent By hmoser Date 2005-12-29 Time 09:56 Rev Time 0.00
Received By hmoser Date 2005-12-29 Time 09:56 Sent To  
Notes
2005-12-29 00:00:00PASS PRIVISO
 PLEASE REMOVE FIRE DAMPER FROM STAIRWELL
 PRESSURIZATION DUCT IN AIR INTAKE WELL
 ON THE PLANS PAGE M1.01.PLEASE RESUBMIT
 THIS PAGE FOR REVISION.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 11 Status P Date 2005-11-09 Cont ID  
Sent By hmoser Date 2005-11-09 Time 10:48 Rev Time 0.00
Received By hmoser Date 2005-11-09 Time 10:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 10 Status P Date 2005-08-26 Cont ID  
Sent By hmoser Date 2005-08-26 Time 11:48 Rev Time 0.00
Received By hmoser Date 2005-08-26 Time 10:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 9 Status P Date 2005-08-01 Cont ID  
Sent By hmoser Date 2005-08-01 Time 07:47 Rev Time 0.00
Received By hmoser Date 2005-08-01 Time 07:47 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 8 Status P Date 2005-07-18 Cont ID  
Sent By hmoser Date 2005-07-18 Time 13:26 Rev Time 0.00
Received By hmoser Date 2005-07-18 Time 13:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 7 Status F Date 2005-06-04 Cont ID  
Sent By hmoser Date 2005-06-04 Time 07:44 Rev Time 0.00
Received By hmoser Date 2005-06-04 Time 07:45 Sent To  
Notes
2005-06-04 00:00:001 PAGE M1.01 CAN NOT TAKE AIR FRON
 GARAGE TO PRESSUREISE STAIR TOWERS.
 2 PLEASE PROVIDE DOOR SCHEDULE PAGE A-48
 MISSING FROM PLANS.PLEASE PROVIDE TYPE
 OF DOOR USED FOR A/C CLOSITS IN SUITES.
 3 PLEASE SHOWDETAIL ON PLANS FOR
 RETURN AIR IN THE SUITES,FROM RETURN AIR
 GRILL TO A/C. UNITS.
 4 PAGE M2.05 STUDIO 1 SHOWES BOOSTER FAN
 IN DRYER EXHAUEST.REFER TO SECTION 504.6
 DOMESTIC CLOTHES DRYER DUCT,BOOSTER FANS
 ARE NOT AN EXCEPTION.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 6 Status N Date 2005-03-01 Cont ID  
Sent By pkrauss Date 2005-03-01 Time 09:54 Rev Time 0.55
Received By pkrauss Date 2005-03-01 Time 09:22 Sent To  
Notes
2005-03-01 00:00:00SUBMITTAL LETER DATED 2-7-05, RE:
 BATHROOM & LAUNDRY EXHAUST
 1.DRYER BOOSTER FANS WILL HAVE TO BE
 SUBMITTED UNDER "ALTERNATE MATERIALS AND
 METHODS" PER 2001 FBC 103.7.1.PROVIDE
 THE FOLLOWING DOCUMENTATION FOR REVIEW
 BY NEIL MELICK, BUILDING OFFICAL:
 1.SUBMITTAL DATA/INSTALLATION
 INSTRUCTIONS FOR THE DRYER.
  
 2.SIGNED, SEALED AND DATED LETTER BY
 THE ENGINEER FROM THE MANUFACTURER
 INDICATING THAT THIS APPLICATION IS
 APPROVED BY THE MANUFACTURER AND WILL
 NOT VOID THE WARRANTY OF THE DRYER.
  
 3.SUBMITTAL DATA/INSTALLATION
 INSTRUCTIONS FOR THE BOOSTER FAN.
  
 CONCERNING THE ISSUE OF THE TERMINATION
 OF THE BATHROOM AND LAUNDRY EXHAUST
 TERMINATING ONTO THE BALCONY, THIS MUST
 BE RESOLVED WITH HAROLD MOSER, CHIEF
 MECHANICAL INSPECTOR AS I HAD APPROVED
 THIS ON THE PLAN REVIEW.
  

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2004-06-24 Cont ID  
Sent By pkrauss Date 2004-06-24 Time 11:22 Rev Time 0.40
Received By pkrauss Date 2004-06-24 Time 11:01 Sent To  
Notes
2004-06-24 00:00:00JACK NEDLIN, ENGINEER (STEVEN FELLER,
 INC) CORRECTED PLAN SHEETS M1.01, M1.02
 AND REPLACED IN SUBMITTED SET.PLAN
 SHEETS M1.03 & M1.04, ENGINEER MADE
 NOTES & SIGNED.M1.03, DUCT AT CEILING
 OF STAIRWELL - THIS WILL HAVE A MINIMUM
 OF 1 HR LID AND WILL NOT IMPEDE THE
 STAIRWELL.PLAN SHEET M1.04, CHANGED
 NOTE INDICATING PROPER WG. (MIN 0.05"
 WG TO 0.35 " WG MAX).CHANGED SEQUENCE
 FOR THE DAMPERS ON SMOKE CONTROL.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2004-06-18 Cont ID  
Sent By pkrauss Date 2004-06-18 Time 14:15 Rev Time 0.55
Received By pkrauss Date 2004-06-18 Time 14:15 Sent To  
Notes
2004-06-18 00:00:00DENIED:
 PLAN SHEETS M1.01 THROUGH M1.03:
 M1.01 GRILLE AT 2 HR WALL, FIRE DAMPER
 REQUIRED.
  
 M1.02, CW PIPE PENTRATING STAIRWELL.
 PENETRATION PROHIBITED PER 2001 FBC
 1006.1.3.1.
  
 M1.03, DUCT THROUG STAIRWELL,
 PENETRATION PROHIBITED PER 2001 FBC
 1006.1.3.1.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2004-04-20 Cont ID  
Sent By pkrauss Date 2004-04-10 Time 10:12 Rev Time 3.00
Received By pkrauss Date 2004-04-10 Time 10:12 Sent To  
Notes
2004-04-10 00:00:00DENIED:
 REFERENCE RESPONSE #12:
 1.PLAN SHEET M6.03 VERTICAL HEAT PUMP
 DETAIL, PER 2001 FBC(M) 307.2.4, THE
 CODE IS VERY SPECIFIC DRAIN PANS ARE TO
 BE BE INSTALLED WHERE POSSIBLE, THE
 ALTERNATIVE IS A DRAIN PAN SECURED ALONG
 SIDE THE UNIT WITH A DRAIN LINE OR A
 LEVEL DETECTOR.THE LEVEL DETECTOR IS
 NOT TO BE INSTALLED IN THE PRIMARY DRAIN
 PAN AS INDICATED.
  
 REFERENCE RESPONSE #13:
 1.PLANS INDICATE CO SENSORS PLANS DO
 NOT INDICATE AT WHAT LEVEL (PPM) THE
 SENSORS ARE SET.PER 2001 FBC 411.4.2
 & 412.5 THE MECHANICAL SYSTEM IS TO
 PROVIDE A MINIMUM OF 6 AIR CHANGES PER
 HOUR & BE CONTINUOUSLY VENTILATED WITH
 SUPPLY AND EXHAUST.
  
 2.PLEASE NOTE, RE-LOCATION OF EXHAUST
 FANS FOR GARAGE VENTILATION.WILL THIS
 BE EFFECTIVE FOR REMOVAL OF CARBON
 MONOXIDE?PLEASE PROVIDE INFORMATION
 AS TO HOW THE CO SENSORS WILL BE
 TESTED.
  
 3.PLANS INDICATE OUTSIDE AIR FOR THE
 CONDO UNITS BY INFILTRATION.PER 2001
 FBC(M) 403.3, VENTILATION SYSTEMS FOR
 OTHER THAN ONE & TWO FAMILY DWELLING
 SHALL BE DESIGNED TO SUPPLY THE MINIMUM
 OF OUSTIDE AIR PER TABLE 403.3.
 PER 2001 FBC(M) 403.2.1 #1 VENTILATION
 AIR SHALL NOT BE RECIRCULATED FROM ONE
 OCCUPANCY TYPE TO ANOTHER.
  
 REFERENCE RESPONSE #11:
 1.PLAN SHEET M4.01 NOTE C, PLEASE
 CLARIFY, WHEN BUILDING GOES INTO ALARM,
 EXHAUST FIRE/SMOKE DAMPERS ON ALL FLOORS
 FOR THE CORRIDORS WILL OPEN & THE SUPPLY
 FIRE/SMOKE DAMPERS WILL CLOSE ON THE
 FLOOR OF INCIDENCE IS THIS CORRECT?
  
 2.FLOOR PLAN INDICATES OA 1 & 2 FOR
 OUTSIDE AIR TO CORRIDORS THE SCHEDULE
 INDICATES RTU'S.PLEASE CORRELATE
 RISERS WITH THE SCHEDULE.
  
 3.PLAN SHEET M1.03 THROUGH M1.09
 INDICATES "CEA" FOR THE CORRIDOR EXHAUST
 & EXHAUST SCHEDULE (M5.02) INDICATES
 "SEF". PLEASE CORRELATE RISERS WITH
 THE SCHEDULE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-11-19 Cont ID  
Sent By pkrauss Date 2003-11-19 Time 09:21 Rev Time 8.00
Received By pkrauss Date 2003-11-05 Time 16:49 Sent To  
Notes
2003-11-19 00:00:00DENIED:
 PLEASE PROVIDE TRANSMITTAL LETTER WITH
 RESPONSES TO COMMENTS TO HELP EXPEDITE
 PLANS IN A MORE TIMELY MANNER.
  
 1.PLAN SHEET A.45B DETAIL G, DRYER
 VENT TO BE NON-SCREENED WITH A BACKDRAFT
 DAMPER AND SHALL NOT PASS THRU PLENUMS
 PER 2001 FBC(M) 504.4.
  
 2.PLAN SHEET M1.03 CLARIFY MAKE-UP AIR
 NEXT TO STAIRWELL PRESSURE RELIEF
 (EXHAUST).
  
 3.M1.03-INDICATES FLAMEBAR DUCT IN
 STAIRWELL. PER 2001 FBC 1006.1.3.1, NO
 DUCT PENETRATIONS THROUGH A STAIRWELL
 EXCEPT FOR STAIRWELL PRESSURIZATION.
 PLEASE PROVIDE SUBMITTAL FOR THE
 FLAMEBAR DUCT.
  
 4.M1.03-PROVIDE MANUFACTURER SUBMITTAL
 DATA ON THE GENERATOR WILL THERE BE A
 FILL TANK OR STORAGE?
  
 5.SUPPLY DUCT FROM HP-G-1 APPEARS TO
 PENETRATE A RATED WALL AT THE ELEVATOR
 LOBBY AREA.FIRE DAMPERS ARE NOT
 REQUIRED AS LONG AS ALL THE CONDITIONS
 OF 607.1.3.
  
 6.FLOORS 2 THRU 8 SUPPLY DUCT FROM
 HP-C-1 REQUIRE A FIRE DAMPER AT THE
 PENETRATION THRU THE WALL TO THE
 CORRIDOR.
  
 7.M1.03 THRU M1.09 INDICATE DOORS WITH
 UNDERCUTS AND LOUVERS ARE THESE FIRE
 RATED CORRIDORS?PLEASE CLARIFY.
  
 8.M1.03 FIRE/SMOKE DAMPERS MISSING
 FROM HP-G-5 WHERE DUCT PASSES THRU RATED
 WALLS.PLEASE CLARIFY.
  
 9.M2.01 & OTHERS INDICATE EXHAUST ON
 TERMINATING ONTO THE TERRANCE PLEASE
 NOTE PER 2001 FBC(M) 401.5.2, EXHAUST
 OPENINGS SHALL BE LOCATED SO AS NOT
 CREATE A NUISANCE. EXHAUST AIR SHALL NOT
 DIRECTED ONTO WALKWAYS.
  
 10. M2.01 NOTE ON PLAN INDICATES SPECFIC
 DRYERS TO BE INSTALLED FOR INCREASED
 VENTING CAPABILITY.PLEASE PROVIDE
 MANUFACTURER SPECS FOR DRYER.DRYERS
 TO BE INSTALLED FOR FINAL INSPECTION.
  
 11. M.401 SMOKE CONTROL - PRESSURIZATION
 OF CORRIDOR PLEASE CLARIFY HOW THIS
 COMPLYS WITH 2001 FBC 412.5.WHERE WILL
 THE SMOKE ON THE FLOOR OF INCIDENT BE
 MIDIGATED TO?
  
 12. AUXILIARY DRAIN PANS REQUIRED PER
 2001 FBC(M) 307.2.3.
  
 13. PROVIDE OUTSIDE AIR CALCULATIONS FOR
 ALL AREAS COMMON AND RESIDENTIAL PER
 2001 FBC(M) 403.3.
  
 14. PROVIDE CALCULATIONS FOR COMBUSTION
 AIR IN THE BOILER ROOM.PROVIDE MIMINUM
 AIR REQUIREMENTS FOR ALL THE MECHANICAL
 ROOMS.INDICATE CALCULATIONS ON PLAN.
  
 15. PLEASE NOTE EXHAUST CONTAINING
 NOXIOUS FUMES, DUST PARTICALS OR SMOKE
 SHALL BE LOCATED A MINIMUM OF 10 FT
 FROM ANY FRESH AIR INTAKE (INCLUDING
 DOORS AND WINDOWS).
  
 16. PLEASE INDICATE IF ANY OF THE
 APPLIANCES ARE GAS.
  
 17. PLEASE NOTE AS PER FS 471.025 AND
 FAC 61G15-23.003, ALL PLANS SHALL BE
 SIGNED (NOT INITIALED), SEALED AND DATED
 BY THE ENGINEER OF RECORD.PLEASE
 REVISE PLANS TO COMPLY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-05-24 Cont ID  
Sent By pkrauss Date 2003-05-24 Time 10:41 Rev Time 4.00
Received By pkrauss Date 2003-05-24 Time 10:40 Sent To  
Notes
2003-05-24 00:00:00DENIED:MECHANICAL PERMIT 03050109
 PLEASE PROVIDE THE FOLLOWING INFORMATION
 FOR REVIEW:
  
 1.PLAN SHEET M1.03 DUCTS PENETRATING
 WALLS WITH 1 HR RATING AT THE LOCATION
 OF THE MAIL RM, STORAGE RM & PUBLIC
 BATHROOMS.PLEASE INDICATE LOCATION OF
 THE FIRE DAMPERS.
  
 2.PLAN SHEET 2.01, LINT TRAP WITH FAN
 BOOSTER INDICATED ON PLAN.PLAN SHEET
 M6.21 INDICATES A SUB-DUCT.PLEASE
 CLARIFY WHICH WILL BE USED. PLEASE NOTE,
 SHOULD THE SUBDUCT METHOD BE USED CLEAN-
 OUTS & SPRINKLER SYSTEM REQUIRED IN THE
 2 HR SHAFT.SHOULD THE BOOSTER FAN
 METHOD BE USED PLEASE PROVIDE DETAIL
 OF "LINT TRAP".BOOSTER FAN MUST HAVE
 SOME TYPE OF NOTIFICATION IF IT FAILS.
  
 4.PLEASE PROVIDE ELEVATION AT WHICH
 THE MUFFLER EXHAUST FROM THE GENERATOR
 WILL TERMINATE.
  
 5.PLEASE PROVIDE OUTSIDE AIR CALCS
 FOR ALL AREAS COMMON AS WELL AS
 RESIDENTIAL.RESIDENTIAL CAN BE BY
 NATURAL MEANS AS PER 2001 FBC(M) 402.2
 OR MECHANICAL TABLE 403.3.
  
 6.A MINIMUM OF 4" CLEARANCE REQUIRED
 AROUND THE VERTICAL AHU AS PER 2001 FBC
 (M) 603.1.3.
  
 7.AS PER 2001 FBC 411.4.2, THE
 MECHANICAL SYSTEM SHALL BE CAPABLE OF
 PROVIDING AT LEAST 6 AIR CHANGES PER
 HOUR FOR EACH LEVEL.
  
 8.PLEASE PROVIDE CALCULATIONS FOR
 GARAGE, BOILER ROOM AND ALL EQUIPMENT
 AND MECHANICAL ROOMS.
  
 9.PLEASE NOTE, MASTER BATHROOMS WHERE
 THE TOILET ROOM IS SEPARATE FROM THE
 BATHING AREA, A FAN WILL BE REQUIRED
 IN THE SHOWER AREA AS WELL AS THE TOILET
 AREA AS PER 2001 FBC(M) 402.3.1.

Review Stop P PLUMBING
Rev No 22 Status P Date 2006-07-26 Cont ID  
Sent By kstevens Date 2006-07-26 Time 10:22 Rev Time 0.00
Received By kstevens Date 2006-07-26 Time 10:22 Sent To  
Notes
2006-07-26 00:00:00REVISIONS APPROVED - SHTS (8.5X11) SK-3,
 SK-4, & SK-5 PLANTER DRAIN 2 NE PLAZA
 WITH RISER CHANGE TO REFLECT CHANGES TO
 SHEETS P1.02, P1.03, & P3.09

Review Stop P PLUMBING
Rev No 21 Status P Date 2006-06-21 Cont ID  
Sent By kstevens Date 2006-06-21 Time 16:55 Rev Time 0.00
Received By kstevens Date 2006-06-21 Time 16:55 Sent To  
Notes
2006-06-21 00:00:00REVISION OK - SHTS P101, P102, P103,
 P301C, P302, P305, P309, P310

Review Stop P PLUMBING
Rev No 20 Status P Date 2006-06-21 Cont ID  
Sent By kstevens Date 2006-06-21 Time 16:53 Rev Time 0.00
Received By kstevens Date 2006-06-21 Time 16:53 Sent To  
Notes
2006-06-21 00:00:00REVISION OK - SHTS P101, P102, P103,
 P103C, P305, P401, P402.

Review Stop P PLUMBING
Rev No 19 Status P Date 2006-03-14 Cont ID  
Sent By pschmitz Date 2006-03-14 Time 10:18 Rev Time 0.00
Received By pschmitz Date 2006-03-14 Time 10:18 Sent To PC
Notes
2006-03-14 00:00:00SUBMITTAL FOR APPROVAL, LOCATION OF BACK
 FLOW PREVENTERS OVER EXHAUST GRATING.
 PRIOR APPROVAL FROM WPBUD, PRE ORVILLE
 POLK.

Review Stop P PLUMBING
Rev No 18 Status F Date 2006-03-08 Cont ID  
Sent By kstevens Date 2006-03-08 Time 09:52 Rev Time 0.00
Received By kstevens Date 2006-03-08 Time 09:52 Sent To  
Notes
2006-03-08 00:00:00REVISION DENIES
  
  
 SHTS P1.03, P3.02, AND P3.06 DELETED THE
 DRINKING FOUNTAIN, DWV PIPING AND THE
 WATER SUPPLY TO DRINKING FOUNTAIN. THIS
 ARE REQUIRED PER TABLE 403.1 FBC-2001
 AND CAN NOT BE DELETED.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 17 Status N Date 2006-02-11 Cont ID  
Sent By kstevens Date 2006-02-11 Time 11:10 Rev Time 0.60
Received By kstevens Date 2006-02-11 Time 11:10 Sent To  
Notes
2006-02-11 00:00:00REVISION - NO PLUMBING PLANS SUBMITTED

Review Stop P PLUMBING
Rev No 16 Status P Date 2005-09-29 Cont ID  
Sent By pschmitz Date 2005-09-29 Time 14:32 Rev Time 0.00
Received By pschmitz Date 2005-09-29 Time 14:30 Sent To  
Notes
2005-09-29 00:00:00REV DATED 8-3,8-10,

Review Stop P PLUMBING
Rev No 15 Status P Date 2005-08-20 Cont ID  
Sent By pschmitz Date 2005-08-20 Time 13:44 Rev Time 0.00
Received By pschmitz Date 2005-08-20 Time 13:44 Sent To B
Notes
2005-08-20 00:00:00REVISIONS OK PES

Review Stop P PLUMBING
Rev No 14 Status F Date 2005-08-02 Cont ID  
Sent By kstevens Date 2005-08-02 Time 09:19 Rev Time 3.81
Received By kstevens Date 2005-08-02 Time 09:19 Sent To M
Notes
2005-08-02 00:00:00REVISION DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1. SHT P1.02 REVISION #6 NOT FOUND, AND
 OTHER REVISIONS TO SHEET NOT CLOUDED OR
 NUMBERED. (CONDENSATE DRAIN LINES, STORM
 DRAIN LINES, BACKWATER VALVE ECT.). -
 NUMBER 44, BACKFLOW PREVENTION REQUIRED
 ON NEW IRRIGATION LINE. SECTION 608.13.2
 2. SHT P1.09 REVISION #1 NOT FOUND.
 REVISIONS REQUIRED FOR ALL RISER
 DIAGRAMS CHANGED ON THIS REVISION. -
 CONDENSATE AND STORM LINES DELETED FROM
 PLANS. - WILL THESE BE SHOWN ON ANOTHER
 SHEET? PLEASE CLARIFY SECTION 104.2.1.
 3. SHT P1.09 INDICATE HOW THE LISTING
 FOR FIRE RATINGS FOR SEPARATION WALLS
 WILL BE MAINTAINED WITH THE LAUNDRY
 BOXES IN TENANT SEPARATION WALLS BETWEEN
 UNITS B1A.1/B1A.1, B1.2/B1.2, &
 B1C.2/B1C.2. ALSO UNIT B2.2 AND THE EXIT
 CORRIDOR.
 4. SHT P1.09 UNABLE TO READ INFORMATION
 AT W/H-A/C CLOSETS AT UNITS B1C.2 AND
 B1D. SECTION 104.2.1.
 5. SHT P1.10 REVISION #2 NOT FOUND AND
 MANY REVISIONS NOT CLOUDED OR NUMBERED.
 SECTION 104.2.1.
 5. P3.01C NEW SHEET WITH REVISIONS?
 PLEASE CLARIFY. WHAT IS THE INTENT OF
 THIS SHEET? THIS SHEET DOES NOT REFLECT
 THE INFORMATION OF THE PREVIOUS SHEET
 SHOWING THE SANITARY COLLECTION SYSTEM.
 ONLY SHOWS ONE CHANGE CLOUDED AND
 NUMBERED. ALL RISER DESIGNATIONS ARE
 CHANGED AND AS SUCH WILL HAVE TO BE
 CHANGED ON ALL SHEETS FOR ALL FLOORS TO
 REFLECT THIS CHANGE. BUILDING DRAIN
 LAYOUT IS CHANGED WITHOUT CLOUDS OR
 REVISION NUMBERS. IF THIS REVISION IS A
 REVISION TO SHEET P3.01, (WHICH IT
 APPEARS TO BE), SIMPLY REVISE SHE P3.01.
 A NEW SHEET NUMBER IS NOT REQUIRED AND
 ONLY CAUSES CONFUSION BECAUSE TWO
 COLLECTION ISOMETRICS WILL BE SHOWN FOR
 ONE SYSTEM. SECTION 104.2.1.
 6. SHT P3.01C STUDOR VENT WILL REQUIRE A
 RELEIF VENT PER SECTION 917.3.2. -
 STUDOR VENTS AT THE LIFT STATIONS ARE
 NOT APPROVED. - INFORMATION ON P3.01C
 WILL DELETE RISER "A" IF THIS SHEET
 SUPERCEEDS SHEET P3.01. PLEASE CLARIFY.
 SECTION 104.2.1.
 7. REVISIONS 5, 6, & 7 ARE NOT FOUND.
 PLEASE CLARIFY. SECTION 104.2.1. MANY
 CHANGES FOUND ON NEW SHEET ARE NOT
 CLOUDED OR NUMBERED/. NO REVIEW OF SHEET
 UNTILL ALL CHANGES TO SHEET FOLLOWING
 THE SHEET SIGNED/SEALED 12-17-04 ARE
 CLOUDED AND NUMBERED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 13 Status P Date 2005-07-12 Cont ID  
Sent By jleech Date 2005-07-12 Time 14:49 Rev Time 0.50
Received By jleech Date 2005-07-12 Time 14:49 Sent To  
Notes
2005-07-12 00:00:00PRODUCT APPROVAL ONLY PRO SET SYSTEM
 FIRE STOPPING.

Review Stop P PLUMBING
Rev No 12 Status F Date 2005-06-13 Cont ID  
Sent By kstevens Date 2005-06-13 Time 10:41 Rev Time 14.33
Received By kstevens Date 2005-06-13 Time 10:41 Sent To  
Notes
2005-06-13 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 1
  
  
 1. SHT P1.01 REVISION 7 NOT FOUND.
 PLEASE CLOUD AND NUMBER EACH REVISION.
 SECTION 104.2.1.
 2. SHT P1.02 REVISION 6 NOT FOUND.
 PLEASE CLOUD AND NUMBER EACH REVISION.
 SECTION 104.2.1.
 3. SHT P1.03 FOLLOWING TO NOT MEET CODE:
 A. TUB NOT VENTED UNIT B1.1 BATH #2
 B. INDICATE WHERE S/14 RISER CONNECTS
 TO THE BLDG. DRAIN. SECTION 104.2.1.
 C. UNIT STUDIO "S2" TOILET IS NOT
 VENTED. LAV SHOULD VENT THE BATHROOM
 FIXTURES AND KITCHEN SINK/WASH MACHINE
 SHALL DISCHARGE DOWNSTREAM OF THE WET
 VENT. SECTIONS 901.2.1 & 909.1.
 D. 2" PIPE FEEDING THE HOSE BIBB?
 PLEASE CLARIFY. SECTION 104.2.1.
 E. UNIT A2 UNABLE TO READ RISER
 DESIGNATION OVER A/C UNIT. SECTION
 104.2.1.
 F. REVISIONS 2, 3, & 4 NOT FOUND.
 PLEASE CLOUD AND NUMBER EACH REVISION.
 SECTION 104.2.1.
 4. SHT P1.04 REVISION #1 NOT FOUND.
 PLEASE CLOUD AND NUMBER ALL REVISIONS.
 SECTION 104.2.1. - SEE UNIT "B2" LAV
 CONNECTION TO BRANCH LINE NOT DIRECTING
 WASTE IN DIRECTIONS OF FLOW. SECTION
 706.3. (COL. LINE W.K)
 5. SHT P1.05 REVISION #1 NOT FOUND.
 PLEASE CLOUD AND NUMBER ALL REVISIONS.
 SECTION 104.2.1. - TWO NUMBER 46 RISERS
 BUT NO NUMBER 47. PLEASE CLARIFY.
 6. SHT P1.06 REVISION #1 NOT FOUND.
 PLEASE CLOUD AND NUMBER ALL REVISIONS.
 SECTION 104.2.1. - SHEET INDICATES
 "TYPICAL FLOOR PLAN - PLUMBING" FOR
 WHICH FLOORS? SECTION 104.2.1. - TWO #46
 SANT. RISERS AND NO #47 SANT. RISER.
 PLEASE CLARIFY.
 7. SHT P1.07 REVISION #1 NOT FOUND.
 PLEASE CLOUD AND NUMBER ALL REVISIONS.
 SECTION 104.2.1. - TWO #46 RISERS AND NO
 #47 RISER FOUND. PLEASE CLARIFY.
 8. SHT P1.08 REVISION #1 NOT FOUND.
 PLEASE CLOUD AND NUMBER ALL REVISIONS.
 SECTION 104.2.1. - SHOW ALL RISER
 DESIGNATION NUMBERS. SECTION 104.2.1.
 9. SHT P1.09 REVISION #1 NOT FOUND.
 PLEASE CLOUD AND NUMBER ALL REVISIONS.
 SECTION 104.2.1. - TWO NUMBER 46 SANT.
 RISERS AND NO #47 RISER FOUND. PLEASE
 CLARIFY.
 10. SHT P1.10 THE FOLLOWING SANT. RISERS
 SHOW UP ON THIS SHEET, BUT WERE NOT
 NOTED ON THE PREVIOUS SHEETS FROM THE
 GROUND FLOOR UP. S/16, S/33, S/51, &
 S/63 PLEASE CLARIFY.-INDICATE THE
 LOCATION OF VTR FOR SANT. RISER 74. -
 RISER S/63 DOES NOT REFLECT THE ROOF
 PLAN. THE FLOOR DRAIN IS NOT SHOWN ON
 RISER. PLEASE CORRELATE RISER WITH FLOOR
 PLAN. - FLOOR DRAIN BY S/64 NOT PIPED TO
 ANY SANT. RISER. PLEASE CLARIFY. SECTION
 104.2.1.
 11. SHT P3.01 SANT. RISER S/8 OFFSET
 VENT REQUIRED. SECTION 915 - VENT STACK
 SHALL CONNECT AT OR BELOW THE THE LOWEST
 HORIZONTAL BRANCH. SECTION 903.4. -
 STACK VENT SHALL RUN UNDIMINISHED IN
 SIZE AND AS DIRECTLY AS POSSIBLE FROM
 THE BUILDING DRAIN THROUGH TO THE OPEN
 AIR. SECTION 903.1.
 12 SHT P3.01 SANT. RISER S/1 A VENT
 STACK IS REQUIRED PER SECTION 903.2 -
 VENT STACK CONNECTION APPEARS TO BE A
 HORIZONTAL DRY VENT. THIS IS NOT
 APPROVED PER SECTIONS 905.3 & 905.4.
 13. SHT P3.01 SANT. RISER S/6-W/7, THE
 FITTING DOWNSTREAM OF STACKS PICKING UP
 THE W/M & TUB DOES NOT DIRECT THE WASTE
 IN THE DIRECTION OF FLOW AS REQUIRED IN
 SECTION 706.3.
 14. SHT P3.01A SANT. RISER S/76
 INDICATES FLOORS 3 THRU 7 TWICE, BUT NO
 FLOOR 8. PLEASE CLARIFY. SECTION
 104.2.1.
 15. SHT P301A SANT. RISER S/19 DOES NOT
 REFLECT THE FLOOR PLAN. SHOWER MISSING
 FROM RISER AND TUB SHOWN IN DIFFERENT
 LOCATION. PLEASE CORRELATE FLOOR PLAN &
 RISER DIAGRAM. SECTION 104.2.1.
 16. SHT P3.01A FLOOR DRAIN NEAR SANT.
 RISER S/69 REQUIRES A RELIEF VENT FOR
 THE AIR ADMITTANCE VALVE. SECTION
 917.3.2.
 17. SHT P3.01C AIR ADMITTANCE VALVE NOT
 APPROVED FOR LIFT STATION. ONLY APPROVED
 FOR NEGATIVE PRESSURE. PLEASE SUBMIT
 MANUFACTURE SPECIFICATION AND
 INSTALLATION SHEETS FOR VALVE INDICATING
 APPROVAL FOR INSTALLATION FOR THIS TYPE
 OF APPLICATION.SECTION 303.2
 18. SHT P3.01C FLOOR SINK FOR INDIRECT
 WASTE FROM 3" FSP THE AIR ADMITTANCE
 VALVE REQUIRES A RELIEF VENT. SECTION
 917.3.2.
 19. SHT P3.01C BUILDING DRAIN LINES DO
 NOT REFLECT THE FLOOR PLAN DOWNSTREAM OF
 RISERS I, J, & K. ALSO THE PIPE SIZING
 FOR I, J, & K DO NOT REFLECT WHAT IS
 STATED IN KEY NOTES #10 WHICH IS 4".
 20. SHT P3.01C INDICATE IF FLOOR DRAIN
 PIPING TO THE LIFT STATION. IT APPEARS
 TO BE ON THE FLOOR ABOVE. PLEASE
 CLARIFY. SECTION 104.2.1. - ALSO ALL
 THREE FLOOR DRAINS TO LIFT STATIONS ARE
 NOT VENTED. SECTION 901.2.1.
 21. SHT P3.02 SANT. RISER S/30, TUB NOT
 VENTED AT THE BASE OF SANT. RISER.
 SECTION 901.2.1.
 22. SHT P3.02 TOILET ROOM DOWNSTREAM OF
 RISERS 2/37-S/67 DOES NOT REFLECT THE
 FLOOR PLAN. LAV NOT SHOWN. CORRELATE
 FLOOR PLAN AND RISER. SECTION 104.2.1. -
 REVISIONS 2 & 3 NOT FOUND. PLEASE CLOUD
 AND NUMBER EACH REVISION.
 23. SHT P3.02 SANT. RISER DIAGRAM, A
 VENT STACK IS REQUIRED, AND AN OFFSET
 VENT IS REQUIRED. SECTIONS 903.3 & 915.
 24. SHT P3.02A BATHROOM DOWNSTREAM OF
 RISER S/53, THE LAV IS MISSING ON THE
 RISER DIAGRAM. THE LAV SHOULD VENT THE
 BATHROOM GROUP AND THE KITCHEN SHOULD
 CONNECT TO THE LINE WITH THE WASH
 MACHINE AND SHOULD NOT DRAIN THROUGHT
 THE HORIZONTAL WET VENT OF THE BATHROOM
 FIXTURES. SECTION 909.1. - THIS IS A NEW
 SHEET AND SHOWS 4 DIFFERENT REVISIONS.
 PLEASE CLARIFY.
 25. SHT P3.03 SANT. RISER S/44 DOES NOT
 REFLECT THE FLOOR PLAN. WASH MACHINE IS
 MISSING. SECTION 104.2.1. - REVISIONS 2
 & 3 NOT FOUND. PLEASE CLOUD AND NUMBER
 EACH REVISION. SECTION 104.2.1.
 26. SHT P3.04 SANT. RISER S/58 DOES NOT
 REFLECT THE FLOOR PLAN, AND THE FIXTURES
 ARE MISLABLED AS LAVS. KITCHEN SINK
 MISSING 2ND FLOOR. SECTION 104.2.1. -
 REVISIONS 2 & 3 NOT FOUND. PLEASE CLOUD
 AND NUMBER EACH REVISION. SECTION
 104.2.1.
 27. SHT P3.09 REVISIONS 5 & 6 NOT FOUND.
 PLEASE CLOUD AND NUMBER EACH REVISIONS.
 SECTION 104.2.1.
 28. SHT P3.11 NATURAL GAS ISOMETRIC:
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS CODE.
 28. SHT P3.12 REVISIONS 2 & 3 NOT FOUND.
 PLEASE CLOUD AND NUMBER ALL REVISIONS.
 SECTION 104.2.1.
 29. SHT P4.01 REVISION #2 NOT FOUND.
 PLEASE CLOUD AND NUMBER EACH REVISIONS.
 SECTION 104.2.1.
 30. THE FOLLOWING SHEETS WERE APPROVED
 AND ONE HAS BEEN ATTACHED TO FILE SET.
 P.1.11, P2.01. [2.02, P2.03, P2.04,
 P3.01B, P3.05, P3.06, & P4.02.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 11 Status F Date 2005-01-13 Cont ID  
Sent By kstevens Date 2005-01-13 Time 07:40 Rev Time 0.25
Received By kstevens Date 2005-01-13 Time 07:40 Sent To  
Notes
2005-01-13 00:00:00DENIED
 REFERENCE: FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
  
 SUBMITTAL DENIED - EACH SHEET SHALL BE
 SIGNED, SEALED, AND DATED. ALL TITLE
 BLOCK INFORMATION TO BE ON EACH SHEET
 61G15-23.002(1)(2) & FS 471.025
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 10 Status P Date 2005-01-11 Cont ID  
Sent By kstevens Date 2005-01-11 Time 15:22 Rev Time 1.75
Received By kstevens Date 2005-01-11 Time 15:22 Sent To  
Notes
2005-01-11 00:00:00REVISION OK - SHTS P1.01, P1.02, P3.09,
 & P3.10

Review Stop P PLUMBING
Rev No 9 Status F Date 2004-12-15 Cont ID  
Sent By kstevens Date 2004-12-15 Time 07:26 Rev Time 0.50
Received By kstevens Date 2004-12-15 Time 07:26 Sent To  
Notes
2004-12-15 00:00:00DENIED
  
 SEE COMMENTS FROM REVISION REVIEW DATED
 12-13-4ATTACHED TO THIS SHEET.
 KSTEVENS

Review Stop P PLUMBING
Rev No 8 Status F Date 2004-12-13 Cont ID  
Sent By kstevens Date 2004-12-13 Time 18:22 Rev Time 2.00
Received By kstevens Date 2004-12-13 Time 18:22 Sent To  
Notes
2004-12-13 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT P1.02 SANITARY LINE FROM HUB
 DRAINS FOR FIRE LINE DRAINS SHOWS
 DIRECTION OF FLOW IN TWO DIRECTIONS NEAR
 THE AIR INTAKE WELL. PLEASE CLARIFY.
 SECTION 104.2.1
 2) SHT P3.09 ACCUMULATED SQUARE FOOTAGE
 IN THE STORM SYSTEM IS NOT CORRECT. SEE
 AREA BY REVISION #3, 12" (20205) PLUS
 FORCED MAIN FROM BELOW (6900) SHOULD BE
 TOTAL OF 27105 SQ.FT., BUT PLANS SHOW
 39385 SQ.FT. SECTION 104.2.1
 3) SHT P3.09 PIPING AT RISER "C" SHOWS
 10" PIPE (9650), AND 8" (7960). 8"
 SHOULD READ (5380) AND 10" SHOULD READ
 (12980). SECTION 104.2.1.
 4) SHT P3.10 FROM PREVIOUS COMMENT,
 PLEASE CORRECT THE SQ.FT. FROM RISER "C"
 TO READ 12,980 SQ.FT. AND 22,440
 UPSTREAM OF THE STORM DRAIN LIFT
 STATION. SECTOPM 104.2.1.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 7 Status F Date 2004-12-02 Cont ID  
Sent By kstevens Date 2004-12-02 Time 11:16 Rev Time 1.75
Received By kstevens Date 2004-12-02 Time 11:16 Sent To  
Notes
2004-12-02 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT P1.01 COL. LINE P.4/P.B INDICATES
 THE PIPING TO (14) IS DELETED, BUT THE
 RISER IS STILL SHOWN. PLEASE CLARIFY.
 SECTION 104.2.1.
 2) STORM DRAIN LINE #9 BY ELEVATOR #1 BY
 COL. LINE P.4. PLEASE INDICATE WHERE
 THIS BRANCH LINE TIES INTO THE STACK.
 SECTION 104.2.1.
 3) REVISIONS ON THE SANITARY SYSTEM
 SHOWN ON SHT P1.01 SHALL BE REFLECTED ON
 THE SANITARY RISER DIAGRAM. PLEASE
 CORRELATE THE RISER DIAGRAM WITH THE
 FLOOR PLAN. SECTION 104.2.1.
 4) SHT P1.01 SANITARY LINE BY THE
 CLEANOUT NEAR COL.LINE P.5. PLEASE
 INDICATE WHERE THIS LINE TIES INTO.
 SECTION 104.2.1.
 5) SHT P3.10 THE STORM RISER DIAGRAM
 DOES NOT REFLECT THE LAYOUT ON SHEET
 P1.01. THE 3" PAD IS SHOWN CONNECTING
 BETWEEN THE TRENCH DRAINS ON THE LAYOUT
 SHEET, BUT DOWN STREAM OF BOTH TRENCH
 DRAINS ON THE STORMDRAIN ISOMETRIC.
 PLEASE CORRELATE THE RISER WITH THE
 LAYOUT. SECTION 104.2.1
  
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 6 Status P Date 2004-06-24 Cont ID  
Sent By mjacobs Date 2004-11-24 Time 16:14 Rev Time 1.00
Received By kstevens Date 2004-06-24 Time 15:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status F Date 2004-06-17 Cont ID  
Sent By kstevens Date 2004-06-17 Time 16:11 Rev Time 2.00
Received By kstevens Date 2004-06-17 Time 16:11 Sent To  
Notes
2004-06-17 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
 FHA-98 DESIGN MANUAL
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) FROM PREVIOUS REVIEW: SHTS A.51 THRU
 A.66 CALCULATIONS FOR 20GA METAL BACKING
 ALL SHEETS SHALL BE SIGNED, SEALED AND
 DATED. ALL INFORMATION FOR TITLE BLOCK
 IS REQUIRED ON ALL SHEETS. ONLY ONE SET
 HAS SEAL/SIGNATURE/DATE OTHER SETS ARE
 COPIES. FAC 61G15-23.002(1)(2) - FS 471.
 025 - ALSO ABOVE MENTIONED SHEETS
 STILL SHOW 20 GA METAL BACKING WHILE THE
 CALCULATIONS INDICATE 16GA METAL BACKING
 CORRELATE PLANS WITH CALCULATIONS. ALSO
 SEE DETAILS ON SHT A.67. SEC 104.2.1
 2) SHT A.63 CLEAR FLOOR SPACE FOR LAV IS
 NOT SHOWN. ALSO LAV SHALL BE CENTERED ON
 THE 48" SIDE OF THE 30"X48" CLEAR FLOOR
 SPACE.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 4 Status F Date 2004-04-12 Cont ID  
Sent By kstevens Date 2004-04-10 Time 18:38 Rev Time 5.50
Received By kstevens Date 2004-04-10 Time 18:38 Sent To  
Notes
2004-04-10 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FBC-2001 BUILDING
 FHA-AMEND. 98 DESIGN MANUAL
  
 A) COMMENTS FROM FIRST TWO REVIEWS NOT
 ADDRESSED SUFFICIENTLY.
 1) SHTS A.11 & A.12 ALL PUBLIC & COMMON
 USE TOILET ROOMS SHALL COMPLY WITH SEC.
 11-4.22 AND ALL SUBSECTIONS. CLEAR FLOOR
 SPACE IS NOT SHOWN FOR WATER CLOSET AND
 LAV IN ACCESSIBLE STALLS IN MENS AND
 WOMENS TOILET ROOMS. (019)
 2) PLEASE SUBMIT CALCULATIONS FOR MINI-
 MUM FIXTURE FACILITIES PER TABLE 403.1.
 MORE INFORMATION REQUIRED. INDICATE ROOM
 NUMBER, ROOM USAGE, AND SQUARE FEET FOR
 EACH ROOM. (EXAMPLE - MAIL ROOM - MGR
 ROOM ECT)
 3) INDICATE LOCATION OF SCUPPER DETAIL
 THAT SHOWS HEIGHT AND WIDTH. DETAIL ON
 SHEET A.45 DOES NOT SHOW HEIGHT OR THE
 WIDTH.
 4) SHTS A.51 THRU A.66 UNIT NOTES #7,
 CALCULATIONS FOR 20GA METAL BACKING.
 RESPONSE "SEE CHM CALCULATIONS" WHERE
 ARE THE CHM CALCULATIONS LOCATED? ALSO
 WHAT ARE CHM CALCULATIONS? IS THERE A
 SHEET WITH THE ABBREVIATIONS SHOWN?
 5) SHT A.11 BAR SINK SHALL COMPLY WITH
 11-4.24 AND ALL SUBSECTIONS. PROVIDE A
 DETAIL. - RESPONSE STATES SHOWN ON SHEET
 A.68 - A.68 SHOWS OUTSIDE ELEVATIONS.
 NO BAR SINK ELEVATIONS SHOWN. (3B)
 6) SCUPPER DETAIL DOES NOT SHOW HEIGHT
 OR WIDTH. THIS INFORMATION IS REQUIRED
 TO DETERMINE THE SIZE OF THE SCUPPER.
 (4B)
 7) SHTS A.51 THRU A.66 SHOW CLEAR FLOOR
 SPACE FOR ALL ACCESSIBLE FIXTURES PER
 FHA DESIGN MANUAL PAGE 7.43 - ALL FIX-
 TURES OF ALL UNITS DO NOT SHOW CLEAR
 FLOOR SPACE.
 8) IT APPEARS THAT SOME OF THESE COMM-
 ENTS HAVE BEEN REJECTED AT LEAST 3 TIMES
 AND A 4 TIMES THE FEE MAY BE ACCESSED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 3 Status F Date 2004-02-11 Cont ID  
Sent By kstevens Date 2004-02-10 Time 17:13 Rev Time 10.00
Received By kstevens Date 2004-02-10 Time 17:12 Sent To  
Notes
2004-02-10 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FHA-AMEND. 98 DESIGN MANUAL
  
 A) COMMENTS FROM THE FIRST AND SECOND
 REVIEW HAVE NOT BEEN ADDRESSED AND NO
 COMMENT RESPONSE NOTED. COMMENT NUMBERS
 FROM FIRST AND SECOND REVEIW WILL REMAIN
 THE SAME FOR CLAIRTY.
 2) PLEASE SUBMIT CALCULATIONS FOR MINI-
 MUM FIXTURE FACILITIES PER TABLE 403.1
 FOR THE BUSINESS/COMMON AREAS GROUND
 FLOOR LEVEL. INCLUDE MGR, ASST. MGR,
 CONFERENCE ROOMS, HEALTH CLUB, FIRE CON-
 TROL, SEC. DESK, VALET, MAIL ROOM, MAIN
 LOBBY, CARD ROOM, FITNESS CENTER, BAR,
 PANTRY, ECT. (NO RESPONSE NOTED)
 3) SUBMIT CALCULATIONS FOR PRIMARY AND
 SECONDARY ROOF DRAINS. SHOW 1/2 AREA OF
 ALL VERTICAL WALLS INCLUDING PARAPETS &
 AREA OF ROOFS THAT DRAIN FROM ABOVE. IN-
 DICATE HOW THE INTERNAL ROOF AREAS,
 (WITHOUT SCUPPERS), ADD TO SCUPPER SIZE
 OF ADJACENT AREAS. SECTIONS 1106 & 1107
 AND ALL SUBSECTIONS. (NO RESPONSE NOTED)
 6) SHEETS A.51 THRU A.61 LAV. ELEVATIONS
 MAXIMUM 34" TO TOP. FHA DESIGN MANUAL
 PAGE 7.52. (NO RESPONSE NOTED - STILL AT
 36" TO TOP).
 8) SHTS A.51 THRU A.66 UNIT PLAN NOTES
 #7, SUBMIT CALCULATIONS FOR 20GA BACKING
 SHOW COMPLIANCE WITH SECTIONS 11-4.26.3,
 11-4.26.3(1), 11-4.26.3(2), 11-4.26.3(3)
 AND 11-4.26.34). (NO RESPONSE NOTED)
 9) SHEETS A.51 THRU A.66 SHOW OPENING
 SIZE FOR ALL WATER CLOSETS. MINIMUM 33".
 (18" OFF WALL WHERE LOCATED NEXT TO ONE,
 AND MINIMUM OF 18" OFF FIXTURE) - THE
 FOLLOWING UNITS DO NOT SHOW SIZE OPENING
 SHT A.52 UNIT A2, SHT A.53 UNIT A5 W/C
 TO BE 1'6" OFF WALL NOT 1'7", SHT A.56
 UNIT B1B, SHT A.57 UNIT B1E, SHT A.59
 UNIT B1E, SHT A.61 UNIT B3, SHT A.62
 UNIT B5, AND SHT A.63 UNIT C1.
 10) SHT P1.01 SHOW PIPE SIZES AND CLEAN-
 OUT LOCTIONS. TABLE 710.1(1) & SECTIONS
 708.3, 708.3.1, AND 708.3.5. (NO RESPON-
 SE NOTED. THE PIPE SIZE CAN BE LOCATED
 ON THE SANT. RISER DIAGRAM, BUT THE C/O
 LOCATIONS SHALL BE SHOWN PER CODE).
 *************FROM 2ND REVIEW************
 3B) SHT A.11 BAR SINK SHALL COMPLY WITH
 11.4.24 AND ALL SUBSECTIONS. PROVIDE A
 DETAIL. (RESPONSE STATES SHOWN ON SHEET
 A.68, BUT NO SHEET A.68 SUBMITTED).
 5B) SHEETS A.51 THRU A.66 SHOW CLEAR
 FLOOR SPACE FOR ALL ACCESSIBLE FIXTURES
 PER FHA DESIGN MANUAL PAGE 7.43. (RES-
 PONSE NOTED BUT ON SHT A.51 THE CLEAR
 FLOOR SPACE FOR THE LAV AND W/C ARE NOT
 ON PLANS. AND FOR SHTS A.52 THRU A.66
 THE CLEAR FLOOR SPACE FOR THE WATER
 CLOSETS ARE NOT ON PLANS).
 37B) 4 TIMES THE FEE FOR PLAN REVIEW
 SHALL NOW BE CHARGED PER FLORIDA STATUTE
 533.80(2)(B) - $133,200.00 IS DUE.
 ******NEW COMMENTS******
 1C) SHT A.55 UNITS B1 & B1.1 INDICATES
 TYPE 'B' BUT BATH #2 IS A TYPE 'A' LAY-
 OUT. PLEASE CLAIRFY.
 2C) SHTS A.56, A.57, A.58, A.59, A.60,
 A.61, A.62, AND A.63 ALL THESE UNITS
 SHOW TYPE 'B', BUT IN EACH SPACE BOTH
 BATHROOMS SHOW CLEAR FLOOR SPACE. WHICH
 BATHROOM WILL BE ADAPTABLE? PLEASE
 CLAIRFY.
 3C) SHTS A.51 THRU A.66 ALL UNITS THAT
 HAVE PARALLEL APPROACH TO LAVS, THE LAVS
 SHALL BE CENTERED ON THE 48" DIMENSION.
 4C) ORIGINAL PERMIT APPLICATION SHALL BE
 SUBMITTED TO ISSUE PERMIT.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-11-18 Cont ID  
Sent By kstevens Date 2003-11-18 Time 09:30 Rev Time 23.00
Received By kstevens Date 2003-11-14 Time 18:54 Sent To  
Notes
2003-11-18 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FHA-98 DESIGN MANUAL
 FLORIDA STATUTES
 FLORIDA ADMINISTRATIVE CODE
 CITY WPB CODE
  
 A) MANY COMMENTS FROM THE FIRST REVIEW
 WERE NOT ADDRESSED AND NO COMMENT RES-
 PONSE NOTED. COMMENT NUMBERS FROM FIRST
 REVIEW WILL BE SHOWN FOR CLAIRITY.
 1) SHTS A.11 & A.12, ALL PUBLIC & COMMON
 USE TOILET ROOMS SHALL COMPLY WITH SEC.
 11-4.22 AND ALL SUBSECTIONS. (CLEAR
 FLOOR SPACE, HEIGHTS, GRAB BARS, ECT.).
 2) PLEASE SUBMIT CALCULATIONS FOR MINI-
 MUM FIXTURE FACILITIES PER TABLE 403.1
 FOR THE BUSINESS/COMMON AREAS GROUND
 FLOOR LEVEL, INCLUDE MGR, ASST. MGR,
 CONFERENCE ROOMS, HEALTH CLUB, FIRE
 CONTROL, SEC. DESK, VALET, MAIL ROOM,
 MAIN LOBBY, CARD ROOM, FITNESS CENTER,
 BAR, PANTRY, ECT.
 3) SUBMIT CALCULATIONS FOR PRIMARY AND
 SECONDARY ROOF DRAINS. SHOW 1/2 AREA OF
 ALL VERTICAL WALLS INCLUDING PARAPETS
 AND AREA OF ROOFS THAT DRAIN FROM ABOVE
 ON TO ROOF ADDED TO SQUARE FOOTAGE OF
 ROOF. SHOW HOW EACH AREA WILL BE AFFECT-
 ED BY VERTICAL WALLS AND ROOF DRAINING
 FROM ABOVE, INDICATE HOW THE INTERNAL
 ROOF AEAS, (WITHOUT SCUPPERS), ADD TO
 SCUPPER SIZE OF ADJACENT AREAS. SECTIONS
 1106 & 1107 AND ALL SUBSECTIONS.
 4) SHT A.09, INDICATE LOCATION OF SECON-
 DARY DRAINS FOR THE DECK AREA AROUND THE
 POOL, AND DECK AREAS BELOW THE POOL DECK
 AREA.
 6) SHTS A.51 THRU A.66, LAV ELEVATIONS
 MAXIMUM 34" TO TOP. FHA DESIGN MANUAL
 PAGE 7.52.
 7) SHTS A.51 THRU A.66, SPECIFICATION
 "A" OR "B" SHALL BE NOTED ON PLANS FOR
 BATHROOMS PER FHA DESIGN MANUAL PAGE
 7.35.
 8) SHTS A.51 THRU A.66, UNIT PLAN NOTES:
 #7, SUBMIT CALCULATIONS FOR 20GA METAL
 BACKING. SHOW COMPLIANCE WITH SECTIONS
 AA-4.26.3, 11-4.26.3(1), 11-4.26.3(2),
 11-4.26.3(3), & 11-4.26.3(4).
 9) SHTS A.51 THRU A.66 SHOW OPENING SIZE
 FOR ALL WATER CLOSETS. MINIMUM SIZE 33".
 (18" OFF WALL WHERE LOCATED NEXT TO ONE,
 AND MINIMUM OF 18" OFF FIXTURE).
 10) SHT P1.01 SHOW PIPE SIZES AND CLEAN-
 OUT LOCATIONS. TABLE 710.1(1) & SECTIONS
 708.3, 708.3.1, 708.3.3, 708.3.5.
 23) SEPARATE GAS PERMIT REQUIRED. THE
 FOLLOWING INFORMATION IS REQUIRED FOR A
 PERMIT.
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS CODE. - NOT ALL SECTIONS INDIC-
 ATE THE LENGTHS.
 B. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED.
 C. TYPE OF GAS, (LP OR NATURAL)
 E. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2001 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES (A)(3). - RECHECK
 DISTANCE.
 F. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2001 FUEL
 GAS CODE SECTION 304.
 G. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2001 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 I. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2001 FUEL GAS CODE SEC 402.2
 J. CLEARLY SHOW THE LOCATION AND CAP-
 ACITY OF LP TANK(S), TYPE OF TANK (DOT
 OR ASME), THE DISTANCE OF THE TANK FROM
 THE BUILDING AND ADJACENT PROPERTY LINES
 THE DISTANCE OF THE TANK FROM ALL SOUR-
 CES OF IGNITION, OTHER CONTAINERS, BUILD
 INGS, AND THE LOCATION OF ANY BUILDING
 OPENINGS BELOW THE RELIEF VALVE OF THE
 TANK PER NFPA 58, TABLE 3-2.2.2.
 K. CLEARLY INDICATE ON THE PLAN IF THE
 LP TANK IS ABOVE OR BELOW GROUND, AND
 SHOW REQUIRED PROTECTION OF THE TANK AND
 APPURTENANCES PER NFPA 58. IF THE TANK
 IS BELOW GROUND THE CONTAINER SHALL BE
 SECURILY ANCHORED PER NFPA 58 SECTION
 3-2.2.7(H).
 *********WHEN RESUBMITTING PLANS********
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 ****************************************
 NEW COMMENTS
 1B) SHT A.12 WALLS IN MEN'S & WOMEN'S
 TOILET ROOMS APPEAR TO BE IN TURNING
 CIRCLE AND IN HDCP STALLS. PLEASE REMOVE
 2B) SUBMIT A DETAIL FOR ACCESSIBLE
 TOILET ROOMS PER 11-4.16, 11-4.19, AND
 11-4.22 AND ALL SUBSECTIONS.
 3B) SHT A.11 BAR SINK SHALL COMPLY WITH
 11-4.24 AND ALL SUBSECTIONS. PROVIDE A
 DETAIL.
 4B) SHT A.45 OVERFLOW SCUPPER DETAIL.
 SCUPPER SHALL BE PLACED IN WALLS OR
 PARAPETS WITH THE INLET FLOW LINE NOT
 LESS THAN 2 INCHES ABOVE THE ROOF SUR-
 FACE, EXCLUDING SUMPS, OR MORE THAN 4
 INCHES ABOVE THE ROOF SURFACE AND SHALL
 BE LOCATED AS CLOSE AS PRACTICAL TO REQ-
 UIRED VERTICAL LEADERS.
 5B) SHTS A.51 THRU A.66 SHOW CLEAR FLOOR
 SPACE FOR ALL ACCESSIBLE FIXTURES PER
 FHA DESIGN MANUAL PAGE 7.43
 6B) SHTS A.51 THRU A.66 UNIT PLAN NOTES:
 #6 STATE 1996 FHA - UPDATE TO READ AMEND
 ED 1998 FHA.
 7B) SHT P1.01 KEY NOTES: #8 & STORM
 DRAIN, 3" FIRE STAND PIPE DRAIN NOT APP-
 ROVED TO STORM. DRAIN SHALL CONNECT TO
 SANITARY VIA INDIRECT WASTE. CITY CODE
 SECTION 90-233(A).
 8B) SHTS P1.01 & P1.02 MORE INFORMATION
 REQUIRED FOR PAD RISER. SEE #'S 14 & 37
 KEY NOTES.
 9B) SHT P1.02 FLOOR DRAINS FOR FIRE AND
 DOMESTIC PUMP ROOMS SHALL CONNECT TO
 SANITARY, NOT STORM. CITY CODE 90-233(A)
 10B) 61G15-23.002(1) SIGNATURE REQUIRED
 ON SEAL. PER FBPE INITALS ARE NOT TO BE
 ACCEPTED. THE SIGNATURE THAT WAS SIGNED
 ON THE ENGINEERS LICENSE SHALL BE RE-
 QUIRED ON EACH SHEET.
 11B) SHT P1.04 RISER DIAGRAM DOES NOT
 REFLECT THE FLOOR PLAN FOR UNIT 1.
 SECTION 104.2.1
 12B) SUBMIT RISER DIAGRAMS FOR RELIEF
 VALVE DISCHARGE LINE (P&T) FOR W/HEATERS
 THE DISCHARGE LINE FOR RELIEF VALVE
 SHALL NOT HAVE ANY TRAPPED SECTIONS AND
 SHALL HAVE A VISIBLE AIR GAP OR AIR GAP
 FITTING IN THE SAME ROOM AS THE WATER
 HEATER. SEC 504.7.1
 13B) SHT P3.01 12" @ 3085 DFU'S AND 12"
 @ 3419 DFU'S NOT APPROVED PER TABLE
 710.1(1).
 14B) SHT P3.03 RISER S/19, 3" REQUIRED
 TO SHOWER. TABLE 909.3
 15B) BACKFLOW PROTECTION REQUIRED FOR
 TRASH CHUTE RING. SECTION 608.13 SUBMIT
 DETAIL.
 16B) SHT P3.05 KEY NOTES: #22, CLAIRFY
 15TH FLOOR. #17 NOT FOUND. (2) # 19'S
 17B) SHT P3.05 SUBMIT CALCULATIONS FOR
 WATER PRESSURE AT BOTTOM OF DROPS FOR
 UNITS TO DETERMINE OF A PRESSURE REGULA-
 TOR IS REQUIRED.
 18B) SHT P3.06 FILTER FOR ICE MACHINE
 SHALL COMPLY WITH NSF STANDARD FOR WATER
 FILTERS. SUBMIT MANUFACTURE SPECIFICAT-
 ION SHEETS. SECTION 303.4
 19B) SHT P3.06 WATER HAMMER ARRESTORS
 REQUIRED AND ICE MACHINE AND DISHWASHER.
 SECTION 604.9
 20B) SHT P3.09 STORM DRAIN COLLECTION
 ISOMETRIC, DOWNSTREAM OF RWL'S 24 & 25
 SHOWS 6"(5280 SF). MINIMUM 8" PIPE REQD.
 21B) SHT P3.09 STORM DRAIN COLLECTION
 ISO., DOWNSTREAM OF (A) SHOWS 6" (2840
 SF) THEN SHOWS 4" PLEASE REVISE. 704.2.
 22B) SHT P3.09 STORM DRAIN COLLECTION
 ISO., PLANTER DRAINS SHOW 40SF PLUS 200
 SF, BUT ONLY ADDS UP TO 80SF. AND AFTER
 6" DD (3300SF) PLUS (240SF) SHOWS (3380
 SF) BUT SHOULD READ (3540SF) PLEASE RE-
 VISE. - INDICATE SF FOR FORCE MAIN FROM
 BELOW. - ALSO DOWNSTREAM OF PD (1040SF)
 SHOWS (900 SF) REVISE.
 23B) PROVIDE INFORMATION FOR FSP DRAIN.
 WHAT TYPE OF DRAIN IS THIS AND WHAT DOES
 IT DRAIN?
 24B) SHT P3.10 PROVIDE MANUF. SPECC.
 SHEETS ON STORM DRAIN LIFT STATION.
 25B) SHT P3.10 FIRE STAND PIPE DRAIN
 SHALL NOT DRAIN TO STORM. CONNECT TO
 SANITARY SYSTTEM.
 26B) SHT P3.11 PROVIDE CUT PIECE MEAS-
 URMENTS FROM METER TO FIRST GAS RISER &
 MEASURMENTS FOR ALL CUT PIECES IN BOILER
 ROOM.
 27B) SHT P3.11 GAS ISOMETRIC, INDICATE
 WHY GAS LINE TO POOL EQUIPMENT ROOM IS
 SLEEVED. PIPING SHALL NOT BE INSTALLED
 IN SOLID FLOOR SLABS. SECTION 404.6
 28B) SHT P3.11 NFPA-54 HAS NOT BEEN
 ADOPTED. SIZE PIPE PER FBC-2001 FUEL GAS
 DELETE REFERENCE.
 29B) SHT P3.12 CONDENSATE COLLECTION ISO
 MINIMUM 2" PIPE UNDERGROUND. SECTION
 710.3
 30B) SHT P3.12 COND. COLLECTION ISO., A
 RELIEF VENT IS REQUIRED AS CONDENSATE
 EXITS THE BLDG.
 31B) SHTS P1.03, THRUP1.09, & P2.01
 UNIT "A", RISER S/70 RISER NOT FOUND AND
 RISER S/18 DOES NOT REFLECT THE FLOOR
 PLAN. SHT P3.04
 32B) SHT P3.03 RISER S/19 TABLE 909.3
 3" REQUIRED TO SHOWER.
 33B) SHTS P1.03 THRU P1.09 & P2.01 UNIT
 "A" MOD, RISER S/71 NOT FOUND AND RISER
 S/53 DOES NOT REFLECT THE FLOOR PLAN.
 SHT P3.04.
 34B) SHT P3.04 RISER S/59 DOES NOT RE-
 FLECT THE FLOOR PLAN.
 35B) SHT P3.04 RISER S/62 DOES NOT RE-
 FLECT THE FLOOR PLAN.
 36B) SUBMIT MANUF. SPEC. SHEET FOR SIM-
 PLEX AND TRIPLES PUMP SYSTEMS.
 37B) SEE ATTACHED SHEET CONCERNING
 FS 533.80(2)(B) DESIGN PROFESSIONAL DOC-
 UMENTS.
 *********WHEN RESUBMITTING PLANS********
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-06-06 Cont ID  
Sent By kstevens Date 2003-06-05 Time 18:08 Rev Time 11.00
Received By rbrown Date 2003-06-04 Time 12:21 Sent To  
Notes
2003-06-05 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 11
 FBC-2001 BUILDING
 FHA-AMEND. 98 DESIGN MANUAL
  
 1) SHTS A.11 & A.12, ALL PUBLIC & COMMON
 USE TOILET ROOMS SHALL COMPLY WITH SEC.
 11-4.22 AND ALL SUB SECTIONS. (5' TURN-
 ING CIRCLE, CLEAR FLOOR SPACE ECT) SEC.
 11-4.1.3(11). (4 TOILET ROOMS #019)
 2) PLEASE SUBMIT CALCULATIONS FOR MINI-
 MUM FIXTURE FACILITIES PER TABLE 403.1
 FOR THE BUSINESS/COMMON AREAS GROUND
 FLOOR LEVEL.
 3) PLEASE SUBMIT CALCULATIONS FOR PRIM-
 ARY AND SECONDARY ROOF DRAINS. PLEASE
 SHOW 1/2 AREA OF ALL VERTICAL WALLS, AND
 SHOW AREA OF ROOFS THAT DRAIN TO ROOF
 DRAINS FROM ABOVE, AND SHOW HOW EACH
 AREA WILL BE AFFECTED BY WALLS AND UPPER
 ROOFS. INDICATE HOW THE INTERNAL ROOF
 AREAS, (WITHOUT SCUPPERS), ADD TO SCUPP-
 ER SIZE OF ADJACENT AREAS. SEC. 1106 &
 1107 AND ALL SUBSECTIONS.
 4) SHT A.09, PLEASE INDICATE LOCATION OF
 SECONDARY DRAINS FOR DECK AREA AROUND
 THE POOL, AND DECK AREAS BELOW THE POOL
 DECK AREA.
 5) SHT A.09 PLEASE INDICATE WHERE THE
 AREA FOR THE COOLING TOWERS WILL DRAIN
 AND IF 1/2 AREA OF ALL VERTICAL WALLS
 WILL BE ADDED TO THAT AREA.
 6) SHTS A.51 THRU A.66, LAV ELEVATIONS
 MAXIMUM 34" TO TOP. FHA DESIGN MANUAL
 PAGE 7.52.
 7) SHTS A.51 THRU A.66, SPECIFICATION
 "A" OR "B" SHALL BE NOTED ON PLANS FOR
 BATHROOMS PER FHA DESIGN MANUAL PAGE
 7.35.
 8) SHTS A.51 THRU A.66, UNIT PLAN NOTES:
 #7, SUBMIT CALCULATIONS FOR 20GA METAL
 BACKING. SHOW COMPLIANCE WITH SECTIONS
 11-4.26.3, 11-4.26.3(1), 11-4.26.3(2),
 11-4.26.3(3), & 11-4.26.3(4). SEE AT-
 TACHED SHEET.
 9) SHTS A.51 THRU A.66 SHOW OPENING
 SIZE FOR ALL WATER CLOSETS. MINIMUM SIZE
 33". (18" OFF WALL WHERE LOCATED NEXT TO
 ONE, AND MINIMUM 18" OFF FIXTURE.)
 10) SHT P1.01 PLEASE SHOW PIPE SIZES AND
 CLEANOUT LOCATIONS. TABLE 710.1(1) AND
 SECTION 708.3, 708.3.1, 708.3.3, 708.3.5
 11) PLEASE SUBMIT SETS OF PLANS WITH ALL
 SHEETS INCLUDED. THE FOLLOWING SHEETS
 REFERENCED ON SHT P1.01 WERE NOT FOUND.
 P3.01, P3.03, P3.05, P3.06, P3.07, P3.08
 P3.09, P3.10, & P3.11.
 12) SHT P1.01 PLEASE SHOW PIPE SIZES AND
 C/0'S REQUIRED BY SEC 104.2.1 AND SEC
 708.3.
 13) SHT P1.07 FLOOR DRAINS REQUIRED IN
 TOILET ROOMS FOR POOL. SEC 424.1.6.1.3
 14) SHT P2.01 UNIT A-2, WASH MACHINE
 SHALL NOT DRAIN THROUGH WET VENT FOR
 BATHROOM FIXTURES. SEC 909.1
 15) SHT P205 NO PIPING LAYOUT IN STUDIO
 UNITS 1, 2, & 3. PLEASE CLAIRFY.
 16) SUBMIT A SANITARY HORIZONTAL ISOMET-
 RIC. PLEASE SHOW ALL PIPE SIZES, SLOP OF
 PIPE, INDICATE WHERE RISERS TIE IN, FIX-
 TURE UNITS AS THEY ACCUMULATE, AND CLEAN
 OUTS. SEC 104.2.1
 17) SUBMIT A STORM WATER ISOMETRIC.
 PLEASE SHOW ALL PIPE SIZES, SLOP OF PIPE
 INDICATE WHERE RISERS TIE IN, SQUARE
 FOOTAGE AS IT ACCUMULATES, AND TERMIN-
 ATION. SEC 104.2.1
 18) SUBMIT A WATER AND SANT. RISER DIA-
 GRAM FOR FOR TYPICAL UNITS AND COMMON
 AREAS. SHOW ALL PIPE SIZES, LOCATION OF
 WATER HAMMER ARRESTORS, ECT. SEC 104.2.1
 19) SHT P4.01 SEPARATE PERMIT/PLANS RE-
 QUIRED FOR POOL/POOL EQUIPMENT ROOM.
 PLANS TO BE REVIEWED AND STAMPED BY THE
 HEALTH DEPT. PRIOR TO SUBMITTING TO CITY
 FOR REVIEW.
 20) SHT 4.02 PLUMBING GENERAL NOTES #16,
 WATER HAMMER ARRESTORS SHALL BE LOCATED
 AT THE ICE MAKER, AND DISHWASHER ALSO,
 SEC 604.9. W.H.A'S SHALL BE LOCATED NEAR
 THE FIXTURE, IN AN "EFFECTIVE RANGE" PER
 PDI-WH 201 AND MANUF. INSTALL. INSTRUCT.
 NOT AT TOP OF DROP, IN THE CEILING.
 21) SUBMIT A CONDENSATE ISOMETRIC FOR
 REVIEW. PLEASE SHOW ALL PIPES SIZES AND
 INDICATE TERMINATION POINT. CONDENSATE
 SHALL RUN SEPARATELY OUT OF BLDG. AND
 TIE INTO STORM LINE OR CATCH BASIN. A
 RELIEF VENT IS REQUIRED AS CONDENSATE
 LINE EXITS THE BLDG.
 22) SHT P4.01 DOMESTIC BOILER SYSTEM DE-
 TAIL, SAFETY PAN ARE REQUIRED FOR THE
 HEATERS AND THE STORAGE TANK. SEC 504.8
 PLEASE SHOW HOW PAN DRAIN LINES WILL BE
 RUN. SUPPLY RISER DIAGRAM IF REQUIRED,
 AND INDICATE SIZE OF PIPING, & MATERIAL
 FOR PIPING. SEC 104.2.1
 23) SEPARATE GAS PERMIT REQUIRED. THE
 FOLLOWING INFORMATION IS REQUIRED FOR
 PERMIT.
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS CODE.
 B. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED.
 PER FBC-2001 FUEL GAS CODE SEC 402.3
 C. TYPE OF GAS, (LP OR NATURAL) SEC402.3
 D. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2001 FUEL GAS CODE SECS. 401.8
 THRU 402.5.2 AND TABLES 402(1) THRU
 402(34).
 E. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2001 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES (A)(3).
 F. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2001 FUEL
 GAS CODE SECTION 304.
 G. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2001 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 H. SUBMIT A DETAIL SHOWING THE TYPE,
 LOCATION, SIZE AND TERMINATION OF THE
 GAS VENTS PER FBC-2001 FUEL GAS CODE
 SECS. 502 THRU 506.
 I. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2001 FUEL GAS CODE SEC 402.2
 J. CLEARLY SHOW THE LOCATION AND CAP-
 ACITY OF LP TANK(S), TYPE OF TANK (DOT
 OR ASME), THE DISTANCE OF THE TANK FROM
 THE BUILDING AND ADJACENT PROPERTY LINES
 THE DISTANCE OF THE TANK FROM ALL SOUR-
 CES OF IGNITION, OTHER CONTAINERS, BUILD
 INGS, AND THE LOCATION OF ANY BUILDING
 OPENINGS BELOW THE RELIEF VALVE OF THE
 TANK PER NFPA 58, TABLE 3-2.2.2.
 K. CLEARLY INDICATE ON THE PLAN IF THE
 LP TANK IS ABOVE OR BELOW GROUND, AND
 SHOW REQUIRED PROTECTION OF THE TANK AND
 APPURTENANCES PER NFPA 58. IF THE TANK
 IS BELOW GROUND THE CONTAINER SHALL BE
 SECURILY ANCHORED PER NFPA 58 SECTION
 3-2.2.7(H).
 *********WHEN RESUBMITTING PLANS********
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 11 Status P Date 2006-07-19 Cont ID  
Sent By aaponte Date 2006-07-19 Time 12:11 Rev Time 0.00
Received By aaponte Date 2006-07-19 Time 12:11 Sent To  
Notes
2006-07-19 00:00:00LANDSCAPE CHANGES APPROVED

Review Stop Z ZONING
Rev No 10 Status F Date 2006-06-26 Cont ID  
Sent By aaponte Date 2006-06-26 Time 11:47 Rev Time 0.00
Received By aaponte Date 2006-06-26 Time 12:07 Sent To  
Notes
2006-06-26 00:00:00LANDSCAPE COMMENTS:
 1. TREES ALONG GARDENIA STREET AND FERN
 STREET SHALL BE REPLACED BY HIGH RISE
 LIVE OAKS. ONLY THE 3 TREES CLOSER TO
 THE BUILDING ALONG FERN STREET CAN BE
 REPLACED BY DAHOON HOLLY.
 2. BY LANDSCAPE PLANNER COMMENT, PLEASE
 CHANGE PLANTING DIAGRAM TO SHOWED ON
 WWW.WPB.ORG/SUGGESTEDTREELIST.PDF, WHEN
 POSSIBLE.

Review Stop Z ZONING
Rev No 9 Status P Date 2006-06-14 Cont ID  
Sent By aaponte Date 2006-06-14 Time 13:21 Rev Time 0.00
Received By aaponte Date 2006-06-07 Time 13:21 Sent To  
Notes
2006-06-14 00:00:00REVISIONS ARE APPROVED. THE FOLLOWING
 COMMENTS ARE FOR CLARIFICATION AND
 CONSISTENCY ON DRAWINGS.
 1. SHEET A.04 SHOWS AN 8 FEET SIDEWALK
 ALONG THE NORHT SIDE OF SAPODILLA,
 HOWEVER SITE PLAN ON SHEET A.01 SHOWS 9
 FEET 1 INCH. PLEASE VERIFY DIMENSION AND
 MODIFY SHEET A.04 TO REFLECT APPROVED
 SITE PLAN.

Review Stop Z ZONING
Rev No 8 Status F Date 2006-05-08 Cont ID  
Sent By aaponte Date 2006-05-08 Time 15:45 Rev Time 0.00
Received By aaponte Date 2006-05-08 Time 15:45 Sent To  
Notes
2006-05-08 00:00:008 INCHES OF LANDSCAPE IS NOT BIG ENOUGH
 TO GROW PLANTS. PLEASE EXTEND THE
 SIDEWALK TO THE FACE OF THE BUILDING.

Review Stop Z ZONING
Rev No 7 Status F Date 2006-02-27 Cont ID  
Sent By astelly Date 2006-02-27 Time 09:16 Rev Time 0.00
Received By astelly Date 2006-02-27 Time 09:15 Sent To  
Notes
2006-02-27 00:00:00PLEASE CONFINE PAVING TO PROPERTY. DO
 NOT EXTEND TO CURB.

Review Stop Z ZONING
Rev No 6 Status F Date 2006-02-14 Cont ID  
Sent By astelly Date 2006-02-14 Time 09:09 Rev Time 0.00
Received By astelly Date 2006-02-14 Time 09:09 Sent To  
Notes
2006-02-17 00:00:00SUBMITTAL FOR ROOFTOP CHAIN LINK FENCE:
  
2006-02-14 00:00:00PLEASE DESIGN SCREENING AS AN INTEGRAL
 PART OF THE BUILDING AS PER
 SEC.94-114(F)(10)OF THE ZONING CODE.

Review Stop Z ZONING
Rev No 5 Status F Date 2005-08-18 Cont ID  
Sent By aaponte Date 2005-08-18 Time 15:06 Rev Time 0.00
Received By aaponte Date 2005-08-18 Time 15:06 Sent To  
Notes
2005-08-18 00:00:00COMMENTS INCLUDED ON THE APPROVAL
 06/24/2004 HAVE NOT BEEN ADDRESSED.IN
 ADDITION, THE PROPOSED CHANGES ON THE
 LANDSCAPE ALONG SAPODILLA ARE AFFECTING
 THE MINIMUM 8 FEET CLEAR SIDEWALK
 REQUIRED. PLEASE MODIFY THE PROPOSED
 LANDSCAPE.

Review Stop Z ZONING
Rev No 4 Status P Date 2004-06-24 Cont ID  
Sent By mmclean Date 2004-06-24 Time 08:41 Rev Time 0.00
Received By mmclean Date 2004-06-24 Time 08:41 Sent To  
Notes
2004-06-24 00:00:00PROVISO:
 1. PLEASE UPDATE DRAWING A-01 TO REFLECT
 CHANGES ON THE SIDEWALK DIMENSION.THE
 NORTH SIDE OF SAPODILLA HAS TO BE 8FT
 AS PRESENTED ON THE GROUND FLOOR
 DRAWINGS.
 2. PLEASE USE LIVE OAK ON FERN STREET
 AND GARDENIA STREET & MEET WITH ALAN
 BARRATTA FROM THE PLANNING DEPT AT
 659-8031 FOR LANDSCAPE PLANTING
 INSTRUCTIONS.
 3. CONFIRM THAT SIGN IS REMOVED FROM
 PLANTER IN THE NORTH PLAZA.
 ANY QUESTION, PLEASE CALL 659-8031,
 ANA MARIE

Review Stop Z ZONING
Rev No 3 Status F Date 2004-04-01 Cont ID  
Sent By rbrown Date 2004-06-23 Time 22:03 Rev Time 0.00
Received By aaponte Date 2004-04-01 Time 16:24 Sent To  
Notes
2004-04-01 00:00:00ACCORDING WITH ARTICLE IV SECTION 94-113
 (B)(7) THE SIDEWALK SHOULD BE MINIMUM 8'
 WIDE. THE SIDEWALK ON THE NORTH SIDE OF
 SAPODILLA IS 6'7".
 SIGN FACES ON NORTH PLAZA PLANTER ARE
 NOT INCLUDED. SIGNS MUST BE MOUNTED ON
 BUILDING, NOT PLANTER.
 THE TRIM SHOULD BE CONSISTENT ALL AROUND
 THE BUILDING. THE TRIM IS NOT SHOWN ON
 THE NORTH ELEVATION (SHEET A23).
 REGARDING LIGHTS ON SAPODILLA,IF REMOVED
 SHALL BE RETURNED TO CURRENT LOCATION BY
 CONTRACTOR AFTER THE JOB IS FINISHED.
 NEW LIGHTS ON FERN AND GARDENIA SHALL
 MATCH THE EXISTING ONES IN SAPODILLA.
 SHADE TREES ON FERN SHALL MATCH EXISTING
 SHADE TREES EAST OF SAPODILLA IN FRONT
 OF CITY PLACE.

Review Stop Z ZONING
Rev No 2 Status F Date 2003-11-04 Cont ID  
Sent By agiannio Date 2003-11-04 Time 15:38 Rev Time 6.00
Received By agiannio Date   Time   Sent To  
Notes
2003-11-04 00:00:00IN RELATION WITH THE PUBLIC OPEN SPACES
 WE HAVE THE FOLLOWING COMMENTS:
 1. PURSUANT TO ARTICLE IV SECTION 94-115
 (E)(5), THE SOUTH PLAZA MUST BE AT SIDE
 WALK GRADE.
 2. PURSUANT TO ARTICLE IV SECTION 94-115
 (E)(1)PUBLIC OPEN SPACE SHALL CONFORM
 TO THE OPEN SPACE DESIGN GUIDELINES. CON
 SIDERING THE INTENTIONS OF THE PUBLIC OP
 EN SPACE GUIDELINES, THE SOUTH PLAZA SHO
 ULD BE MORE INVITING FOR THE GENERAL PUB
 LIC-THE LANDSCAPE DESIGN IN CONJUCTION W
 ITH THE GRADE ACTS AS A BARRIER.
 3.THE DRAWINGS SHOULD DEPICT DETAILS OF
 THE BENCHES OR SEATING AREA AS WELL AS T
 HE LOCATION OF THE DRINKING FOUNTAINS AS
 REQUIRED BY THE PUBLIC OPEN SPACE DESIG
 N GUIDELINES.
 4. PLEASE CONFIRM THAT THE PROPOSED STRE
 ET LIGH LOCATION AND TREE SPECIES AND LO
 CATIONS CONFORM TO THE EXISTING STREETSC
 APE ON SAPODILLA AVENUE.
  
 IN RELATION WITH THE BUILDING PLACEMENT
 WE HAVE THE FOLLOWING COMMENTS:
 1. ACCORDING WITH ARTICLE IV SECTION 94-
 113 (B)(7) THE SIDEWALK SHOULD BE MINIMU
 M 8' WIDE. THE SIDE WALK ON GARDENIA STR
 EET IS 5'9" (AS DEPICTED IN DRAWING A-01
 ).
  
 IN RELATION WITH THE ARCHITECTURAL DESIG
 N GUIDELINES WE HAVE THE FOLLOWING COMME
 NTS:
 1. TO FURTHER DIFFERENTIATE THE "CAP" FR
 OM THE "MIDDLE" OF THE BUILDING, BALCONY
 RAILINGS ON THE EIGHT FLOOR SHOULD BE T
 HE FULL METAL DESIGN CONSISTENT WITH THE
 SMALLER BALCONIES.
 2. BALCONIES ON SOUTH AND NORTH ELEVATIO
 N SHOULD BE ARCHED CONSISTENT WITH THE E
 AST ELEVATION.
 3.THE BALCONIES ON THE 7TH FLOOR SHOULD
 ALL HAVE THE SAME PROPORTION OPENING (US
 E THE TALLER VERSION).
 4.THE TRIM SHOULD BE CONSISTENT ALL AROU
 ND THE BUILDING. IT STOPS OVER THE NORTH
 PLAZA (SHEET A-21A).
 5. THE BRACKETS UNDER THE BALCONIES NEED
 TO BE CREDIBLE SUPPORTS; PLEASE REVISE
 DETAIL.
  
 IN RELATION WITH THE ROOF TERRACE WE HAV
 E THE FOLLOWING COMMENTS:
 1.THE OVERALL ROOF TERRACE HAS TO BE 15%
 LANDSCAPED.
 2. THE PERCENTAGE OF COVERED AREA SHOULD
 NOT EXCEED 30% OF THE GROSS ROOF AREA.
 3.PLEASE PROVIDE A TABLE WITH THE PERCEN
 TAGE OF LANDSCAPED AREA AND THE PERCENTA
 GE OF COVERED AREA.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-03-29 Cont ID  
Sent By csiegber Date 2003-10-17 Time 15:19 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
2003-05-20 00:00:00DENIED, NEED TO MEET ANTHEA G ABOUT
 THE PROCESS


Account Summary | Usage Policy | Privacy Policy