Plan Review Stops For Permit 03050107 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
116 |
Status |
P |
Date |
2006-10-28 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-10-28 |
Time |
21:32 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-10-28 |
Time |
21:32 |
Sent To |
|
|
Notes |
2006-10-28 21:33:31 | SUBMITTAL ON 10/19/06 FOR ROOF LEVEL ACCESSIBLE RAMPS | | (ORIGINALLY SUBMITTED ON 10/3/06, BUT DENIED) |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
115 |
Status |
P |
Date |
2006-10-28 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-10-28 |
Time |
21:30 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-10-28 |
Time |
21:30 |
Sent To |
|
|
Notes |
2006-10-28 21:31:35 | SUBMITTAL ON 10/13/06 FOR MECHANICAL PIPE STANDS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
114 |
Status |
F |
Date |
2006-10-09 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-10-11 |
Time |
20:37 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-10-09 |
Time |
20:37 |
Sent To |
|
|
Notes |
2006-10-09 21:00:41 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6652 | | E-MAIL: [email protected] | | | | SUBMITTAL ON 10/3/06 FOR ROOF LEVEL ACCESSIBLE RAMPS. | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | F.S.= FLORIDA (STATE) STATUTE | | | | 1) 61G15-23.002(2)FL. ADMIN. CODE. | | THE ENGINEER'S SIGNATURE ON THE CLACULATIONS IS | | PHOTOCOPIED.ORIGINAL SIGNATURES ARE REQUIRED.ALSO, | | EITHER EACH SHEET OF THE CALCULATIONS SHALL BE SIGNED | | AND SEALED OR THE ENGINEER SHALL SIGN AND SEAL AN INDEX | | SHEET LISTING EACH SHEET NUMBER INCLUDED IN THE | | CALCULATION REPORT. | | (471.025 F.S. AND 471.023 F.S.). | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO TELEPHONE: | | (561) 805 6652ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
113 |
Status |
F |
Date |
2006-08-27 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-08-27 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-08-27 |
Time |
15:41 |
Sent To |
|
|
Notes |
2006-08-27 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6652 | | E-MAIL: [email protected] | | | | REVISION SUBMITTED ON 8/18/06 FOR SHEET | | A.04. | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | F.S.= FLORIDA (STATE) STATUTE | | | | 1) FBC 704.2.4 AND 705.1.2EXIT ACCESS | | CORRIDOR.THE BUSINESS CENTER DOOR WAS | | SPECIFIED ON SHEET A.48 AS A MIN. 20 | | MINUTE FIRE-RATED DOOR BECAUSE IT IS ON | | AN EXIT ACCESS CORRIDOR.THE DOOR SHALL | | NOT BE OMITTED. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6652ROBERT BROWN | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
112 |
Status |
P |
Date |
2006-08-20 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-08-20 |
Time |
21:36 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-08-20 |
Time |
21:36 |
Sent To |
|
|
Notes |
2006-08-20 00:00:00 | SUBMITTAL FOR EXTERIOR METAL STUD | | FRAMING SPECS.SIGNED AND SEALED | | ORIGINALS WERE STAMPED AND RETURNED ON | | 6/25/06 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
111 |
Status |
P |
Date |
2006-08-20 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-08-20 |
Time |
21:13 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-08-20 |
Time |
21:13 |
Sent To |
|
|
Notes |
2006-08-20 00:00:00 | SUBMITTAL ON 4/22/06 FOR METAL BIFOLD | | DOORS ON AC CLOSETS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
110 |
Status |
P |
Date |
2006-08-20 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-08-20 |
Time |
21:12 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-08-20 |
Time |
21:12 |
Sent To |
|
|
Notes |
2006-08-20 00:00:00 | ARCHITECTURAL REVISION SUBMITTED ON | | 7/31/06 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
109 |
Status |
P |
Date |
2006-08-20 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-08-20 |
Time |
21:11 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-08-20 |
Time |
21:11 |
Sent To |
|
|
Notes |
2006-08-20 00:00:00 | ARCHITECTURAL REVISION SUBMITTED ON | | 6/30/06 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
108 |
Status |
P |
Date |
2006-08-20 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-08-20 |
Time |
19:57 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-08-20 |
Time |
19:57 |
Sent To |
|
|
Notes |
2006-08-20 00:00:00 | ARCHITECTURAL REVISION SUBMITTED ON | | 6/22/06 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
107 |
Status |
P |
Date |
2006-08-20 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-08-20 |
Time |
19:56 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-08-20 |
Time |
19:56 |
Sent To |
|
|
Notes |
2006-08-20 00:00:00 | ARCHITECTURAL REVISION SUBMITTED ON | | 4/11/06 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
106 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-25 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-25 |
Time |
14:33 |
Sent To |
|
|
Notes |
2006-06-25 00:00:00 | STRUCTURAL SUBMITTAL FOR ALUMINUM | | TRELLIS AT COURTYARD |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
105 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-25 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-25 |
Time |
14:32 |
Sent To |
|
|
Notes |
2006-06-25 00:00:00 | STRUCTURAL SUBMITTAL FOR SUPPORT OF | | GENERATOR EXHAUST EXTENSION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
104 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-25 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-25 |
Time |
14:31 |
Sent To |
|
|
Notes |
2006-06-25 00:00:00 | SUBMITTAL FOR EXTERIOR METAL STUD | | FRAMING AT ROOFTOP CABANA AND ELEVATOR | | LOBBIES |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
103 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-25 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-25 |
Time |
13:48 |
Sent To |
|
|
Notes |
2006-06-25 00:00:00 | SUBMITTAL FOR CEILING IN ROOFTOP | | ELEVATOR LOBBIES |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
102 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-25 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-25 |
Time |
13:38 |
Sent To |
|
|
Notes |
2006-06-25 00:00:00 | SUBMITTAL FOR ELEVATOR SHAFT ACCESS DOOR | | CUT DOWN. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
101 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-25 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-25 |
Time |
13:31 |
Sent To |
|
|
Notes |
2006-06-25 00:00:00 | SUBMITTAL FOR SPA SIGNAGE STAND MOUNTED | | ON POOL DEECK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
100 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-25 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-25 |
Time |
13:26 |
Sent To |
|
|
Notes |
2006-06-25 00:00:00 | SUBMITTAL FOR BILCO ROOF HATCH SHOP | | DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
99 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-25 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-25 |
Time |
13:19 |
Sent To |
|
|
Notes |
2006-06-25 00:00:00 | SUBMITTAL FOR GRATING AT VEHICLE RAMP | | AND LOADING DOCK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
98 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-25 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-25 |
Time |
13:12 |
Sent To |
|
|
Notes |
2006-06-25 00:00:00 | SUBMITTAL FOR POOL/SPA REINFORCING | | STEEL SHOP DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
97 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-25 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-25 |
Time |
13:05 |
Sent To |
|
|
Notes |
2006-06-25 00:00:00 | SUBMITTAL FOR WEST COURTYARD FORMWORK | | SHOP DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
96 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-25 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-25 |
Time |
13:01 |
Sent To |
|
|
Notes |
2006-06-25 00:00:00 | SUBMITTAL FOR POOL/SPA DECK FORMWORK | | SHOP DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
95 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-25 |
Time |
12:57 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-25 |
Time |
12:56 |
Sent To |
|
|
Notes |
2006-06-25 00:00:00 | SUBMITTAL FOR EXTERIOR METAL STUD | | FRAMING SPECS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
94 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-25 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-25 |
Time |
12:49 |
Sent To |
|
|
Notes |
2006-06-25 00:00:00 | STRUCTURAL SUBMITTAL FOR CHM REPORT ON | | DESIGN LOADS AT TIE CLOUMNS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
93 |
Status |
P |
Date |
2006-04-14 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-04-14 |
Time |
18:50 |
Rev Time |
0.00 |
Received By |
ssarley |
Date |
2006-05-11 |
Time |
11:36 |
Sent To |
|
|
Notes |
2006-04-14 00:00:00 | ARCHITECTURAL SUBMITTAL ON 4/6/06 FOR | | STORAGE UNIT LOCKER DETAILS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
92 |
Status |
F |
Date |
2006-04-06 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-04-06 |
Time |
11:57 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-04-06 |
Time |
11:57 |
Sent To |
|
|
Notes |
2006-04-06 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6652 | | E-MAIL: [email protected] | | | | NO OBJECTION TO PROPOSED TRANSFER DUCT | | AND FIRE DAMPER SOLUTION.MUST BE | | SUBMITTED FORMALLY AS A SIGNED AND | | SEALED REVISION. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
91 |
Status |
F |
Date |
2006-03-11 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-03-11 |
Time |
23:13 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-03-11 |
Time |
23:13 |
Sent To |
|
|
Notes |
2006-03-11 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6652 | | E-MAIL: [email protected] | | | | ARCHITECTURAL REVISION SUBMITTED | | 11/16/05. | | | | ALL ARCHITECTURAL SHEETS O.K. EXCEPT | | SHEETS A.04 AND A.11 TO A.15.SEE | | COMMENTS BELOW: | | | | 1) SHEETS A.04 AND A.11 TO A.15 SHOW | | CHANGED SETBACK DIMENSIONS BETWEEN THE | | BUILDING AND THE PROPERTY LINE.IT WILL | | BE NECESSARY TO SUBMIT A REVISED SITE | | PLAN (SHEET A.01) FOR REVIEW BY PLANNING | | AND ZONING BEFORE SHEETS A.04 AND A.11 | | TO A.15 CAN BE PASSED.ALL THREE SETS | | OF THESE SHEETS ARE BEING RETURNED, | | UNSTAMPED. | | | | 2) FBC 1007.5SHEETS A-04 AND A.11. | | HANDRAILS ARE REQUIRED ON EACH SIDE OF | | THE STAIRWAY NOW SHOWN IN THE EXIT | | PASSAGEWAY LEADING FROM STAIR #3 TO | | FERN ST. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6652ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
90 |
Status |
P |
Date |
2006-03-11 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-03-11 |
Time |
23:11 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-03-11 |
Time |
23:11 |
Sent To |
|
|
Notes |
2006-03-11 00:00:00 | ARCHITECTURAL REVISION SUBMITTED 9/12/05 | | FOR SHEETS A.21, A.21A, A.22, A.23, A.24 | | AND A.24A |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
89 |
Status |
F |
Date |
2006-02-17 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-02-17 |
Time |
18:39 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-02-17 |
Time |
18:39 |
Sent To |
|
|
Notes |
2006-02-17 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6652 | | E-MAIL: [email protected] | | | | SUBMITTAL ON 2/1/06 FOR ROOFTOP CHAIN | | LINK FENCING. | | | | 1) PLEASE ADDRESS THE ZONING PLAN | | REVIEWER'S COMMENT AND RESUBMIT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
88 |
Status |
P |
Date |
2005-08-26 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-08-26 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-08-26 |
Time |
12:22 |
Sent To |
|
|
Notes |
2005-08-26 00:00:00 | REVISION SUBMITTED 7/26/05 INCLUDING | | LANDSCAPE PLANS AND SHEETS A.41, A.42 | | AND A.42A |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
87 |
Status |
P |
Date |
2005-08-22 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-08-22 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-08-22 |
Time |
08:49 |
Sent To |
|
|
Notes |
2005-08-22 00:00:00 | STRUCTURAL SUBMITTAL ON 8/17/05 FOR | | SKYLINE STEEL GRATING SUPPORT SHOP | | DRAWING |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
86 |
Status |
P |
Date |
2005-08-19 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-08-19 |
Time |
18:25 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-08-19 |
Time |
09:08 |
Sent To |
|
|
Notes |
2005-08-19 00:00:00 | REVISION SUBMITTED ON 7/18/05. | | | | NOTE: | | | | 1) THE REVISED SHEET A.06 (3RD FLOOR | | PLAN) NOW SHOWS A LAYOUT FOR THE UNIT | | 'C' DEN THAT IS DIFFERENT TO THAT SHOWN | | ON SHEET A-19 | | | | 2) THE REVISED SHEET A.06 (3RD FLOOR | | PLAN) SHOULD REFER TO SHEET A.16.1 (3RD | | FLOOR PARTIAL PLAN 'F') INSTEAD OF SHEET | | A.16 (TYPICAL FLOOR PARTIAL PLAN 'F') |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
85 |
Status |
P |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-08-09 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-08-09 |
Time |
14:45 |
Sent To |
|
|
Notes |
2005-08-09 00:00:00 | SUBMITTAL ON 8/3/05 FOR 3M FIRE BARRIER | | WATER TIGHT SEALANT MATERIAL SPEC. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
84 |
Status |
P |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-08-09 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-08-09 |
Time |
14:44 |
Sent To |
|
|
Notes |
2005-08-09 00:00:00 | SUBMITTAL ON 7/18/05 FOR LATITE ROOFING | | -LIGHTWEIGHT INSULATING CONCRETE | | LETTER AND DOCS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
83 |
Status |
P |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-08-09 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-08-09 |
Time |
14:01 |
Sent To |
|
|
Notes |
2005-08-09 00:00:00 | SUBMITTAL ON 7/18/05 FOR LIGHTWEIGHT | | INSULATING CONCRETE ROOF SHOP DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
82 |
Status |
P |
Date |
2005-07-27 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-07-27 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-07-27 |
Time |
12:44 |
Sent To |
|
|
Notes |
2005-07-27 00:00:00 | STRUCTURAL SUBMITTAL ON 7/7/05 FOR UPPER | | ROOF LEVEL SHORING AND RE-SHORING SHOP | | DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
81 |
Status |
P |
Date |
2005-07-27 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-07-27 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-07-27 |
Time |
12:34 |
Sent To |
|
|
Notes |
2005-07-27 00:00:00 | STRUCTURAL SUBMITTAL ON 7/7/05 FOR | | GULFSTREAM GROUND FLOOR PLANTER WALL AND | | SLAB REINFORCEMENT SHOP DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
80 |
Status |
P |
Date |
2005-07-27 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-07-27 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-07-27 |
Time |
11:37 |
Sent To |
|
|
Notes |
2005-07-27 00:00:00 | STRUCTURAL SUBMITTAL ON 7/7/05 FOR | | GULFSTREAM PLANTER WALL AND ROOF SLAB | | REINFORCEMENT SHOP DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
79 |
Status |
P |
Date |
2005-07-27 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-07-27 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-07-27 |
Time |
11:15 |
Sent To |
|
|
Notes |
2005-07-27 00:00:00 | FURTHER SUBMITTAL ON 7/7/05 FOR B.C. | | INDUSTRIES (ERIC C. VANHORN, P.E.) SHIM | | SPACE AND FASTENER ANALYSIS FOR SUN | | METAL WINDOWS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
78 |
Status |
P |
Date |
2005-07-27 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-07-27 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-07-27 |
Time |
10:40 |
Sent To |
|
|
Notes |
2005-07-27 00:00:00 | SUBMITTAL ON 6/29/05 FOR B.C. INDUSTRIES | | (ERIC C. VANHORN, P.E.) SHIM SPACE AND | | FASTENER ANALYSIS FOR SUN METAL WINDOWS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
77 |
Status |
P |
Date |
2005-07-27 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-07-27 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-07-27 |
Time |
10:27 |
Sent To |
|
|
Notes |
2005-07-27 00:00:00 | STRUCTURAL SUBMITTAL ON 7/27/05 FOR CECO | | CONCRETE CONSTRUCTION LLC UPPER ROOF | | LEVEL FORMWORK SHOP DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
76 |
Status |
P |
Date |
2005-07-27 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-07-27 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-07-27 |
Time |
10:23 |
Sent To |
|
|
Notes |
2005-07-27 00:00:00 | STRUCTURAL SUBMITTAL ON 6/28/05 FOR CECO | | CONCRETE CONSTRUCTION LLC BUCKHOIST | | RE-SHORING PLANS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
75 |
Status |
P |
Date |
2005-07-27 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-07-27 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-07-27 |
Time |
09:07 |
Sent To |
|
|
Notes |
2005-07-27 00:00:00 | ARCHITECTURAL SUBMITTAL ON 6/28/05 FOR | | DRYWALL FRAMING, CAULKING, BACKING AND | | FIRE-TREATED WOOD. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
74 |
Status |
P |
Date |
2005-07-26 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-07-26 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-07-26 |
Time |
14:43 |
Sent To |
|
|
Notes |
2005-07-26 00:00:00 | STRUCTURAL SUBMITTAL ON 6/17/05 FOR | | PTE STRAND 8TH FLOOR POST-TENSION CABLE | | SHOP DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
73 |
Status |
P |
Date |
2005-06-16 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-16 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-16 |
Time |
16:40 |
Sent To |
|
|
Notes |
2005-06-16 00:00:00 | ARCHITECTURAL/STRUCTURAL REVISION (PART | | OF 145 SHEET B,M,E & P REVISION) | | SUBMITTED ON 4/6/05 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
72 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-15 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-15 |
Time |
14:09 |
Sent To |
|
|
Notes |
2005-06-15 00:00:00 | STRUCTURAL SUBMITTAL ON 6/7/05 FOR | | GULFSTREAM ROOF SLAB REINFORCEMENT SHOP | | DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
71 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-15 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-15 |
Time |
14:05 |
Sent To |
|
|
Notes |
2005-06-15 00:00:00 | STRUCTURAL SUBMITTAL ON 6/7/05 FOR CECO | | ROOF LEVEL SHORING AND RE-SHORING SHOP | | DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
70 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-15 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-15 |
Time |
14:02 |
Sent To |
|
|
Notes |
2005-06-15 00:00:00 | STRUCTURAL SUBMITTAL ON 6/7/05 FOR POUR | | 3, ROOF LEVEL SHORING INSPECTION | | LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
69 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-15 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-15 |
Time |
13:57 |
Sent To |
|
|
Notes |
2005-06-15 00:00:00 | STRUCTURAL SUBMITTAL ON 5/27/05 FOR POUR | | 2, ROOF LEVEL SHORING INSPECTION | | LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
68 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-15 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-15 |
Time |
13:51 |
Sent To |
|
|
Notes |
2005-06-15 00:00:00 | STRUCTURAL SUBMITTAL ON 5/20/05 FOR POUR | | 1, ROOF LEVEL SHORING INSPECTION | | LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
67 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-15 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-15 |
Time |
13:43 |
Sent To |
|
|
Notes |
2005-06-15 00:00:00 | STRUCTURAL SUBMITTAL ON 5/17/05 FOR | | GULFSTREAM ROOF SLAB REINFORCEMENT SHOP | | DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
66 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-15 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-15 |
Time |
13:39 |
Sent To |
|
|
Notes |
2005-06-15 00:00:00 | STRUCTURAL SUBMITTAL ON 5/14/05 FOR POUR | | 3, 8TH LEVEL SHORING INSPECTION LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
65 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-15 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-15 |
Time |
13:30 |
Sent To |
|
|
Notes |
2005-06-15 00:00:00 | STRUCTURAL SUBMITTAL ON 5/17/05 FOR 8TH | | LEVEL CECO FORMWORK SHOP DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
64 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-15 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-15 |
Time |
10:42 |
Sent To |
|
|
Notes |
2005-06-15 00:00:00 | STRUCTURAL SUBMITTAL ON 5/11/05 FOR POUR | | 2, 8TH LEVEL SHORING INSPECTION LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
63 |
Status |
P |
Date |
2005-06-09 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-09 |
Time |
20:17 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-09 |
Time |
20:17 |
Sent To |
|
|
Notes |
2005-06-09 00:00:00 | STRUCTURAL SUBMITTAL ON 5/5/05 FOR | | PTE STRAND 8TH FLOOR POST-TENSION CABLE | | SHOP DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
62 |
Status |
P |
Date |
2005-06-09 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-09 |
Time |
20:10 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-09 |
Time |
20:10 |
Sent To |
|
|
Notes |
2005-06-09 00:00:00 | STRUCTURAL SUBMITTAL ON 5/5/05 FOR 8TH | | LEVEL SHORING AND RE-SHORING SHOP | | DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
61 |
Status |
P |
Date |
2005-06-09 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-09 |
Time |
20:07 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-09 |
Time |
20:07 |
Sent To |
|
|
Notes |
2005-06-09 00:00:00 | STRUCTURAL SUBMITTAL ON 5/5/05 FOR | | GULFSTREAM 2ND TO 6TH FLOOR TIE COLUMN | | AND MASONRY STEEL REINFORCEMENT SHOP | | DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
60 |
Status |
P |
Date |
2005-06-09 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-06-09 |
Time |
20:03 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-06-09 |
Time |
20:03 |
Sent To |
|
|
Notes |
2005-06-09 00:00:00 | STRUCTURAL SUBMITTAL ON 5/5/05 FOR | | POUR #1, 8TH LEVEL SHORING INSPECTION | | LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
59 |
Status |
P |
Date |
2005-05-06 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-05-06 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-05-06 |
Time |
13:04 |
Sent To |
|
|
Notes |
2005-05-06 00:00:00 | STRUCTURAL SUBMITTAL ON 4/27/05 FOR POUR | | 3, 7TH LEVEL SHORING INSPECTION LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
58 |
Status |
P |
Date |
2005-05-06 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-05-06 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-05-06 |
Time |
12:41 |
Sent To |
|
|
Notes |
2005-05-06 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | STRUCTURAL SUBMITTAL ON 4/27/05 FOR | | GULFSTREAM 1ST FLOOR MASONRY AND TIE | | COLUMN REINFORCEMENT SHOP DRAWINGS | | | | --PROVISO-- | | COMPLY WITH ENGIEER OF RECORD COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
57 |
Status |
P |
Date |
2005-05-06 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-05-06 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-05-06 |
Time |
12:36 |
Sent To |
|
|
Notes |
2005-05-06 00:00:00 | STRUCTURAL SUBMITTAL ON 4/27/05 FOR | | GULF STREAM 8TH FLOOR REINFORCEMENT SHOP | | DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
56 |
Status |
P |
Date |
2005-05-06 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-05-06 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-05-06 |
Time |
12:19 |
Sent To |
|
|
Notes |
2005-05-06 00:00:00 | STRUCTURAL SUBMITTAL ON 4/27/05 FOR POUR | | 2, 7TH LEVEL SHORING INSPECTION LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
55 |
Status |
P |
Date |
2005-05-06 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-05-06 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-05-06 |
Time |
12:13 |
Sent To |
|
|
Notes |
2005-05-06 00:00:00 | STRUCTURAL SUBMITTAL ON 4/27/05 FOR | | GROUND LEVEL RAMP TO PARKING LEVEL | | SHORING INSPECTION LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
54 |
Status |
P |
Date |
2005-05-06 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-05-06 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-05-06 |
Time |
11:30 |
Sent To |
|
|
Notes |
2005-05-06 00:00:00 | STRUCTURAL SUBMITTAL ON 4/26/05 FOR | | CECO CONCRETE CONSTRUCTION 3RD TO 7TH | | FLOOR SHORING SHOP DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
53 |
Status |
P |
Date |
2005-05-06 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-05-06 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-05-06 |
Time |
11:00 |
Sent To |
|
|
Notes |
2005-05-06 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | STRUCTURAL SUBMITTAL ON 4/26/05 FOR | | PTE STRAND 3RD TO 7TH FLOOR BANDED AND | | UNIFORM TENDON SHOP DRAWINGS. | | | | --PROVISO-- | | COMPLY WITH ENGINEER OF RECORD COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
52 |
Status |
P |
Date |
2005-04-27 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-04-27 |
Time |
18:10 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-04-27 |
Time |
18:10 |
Sent To |
|
|
Notes |
2005-04-27 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | STRUCTURAL SUBMITTAL ON 4/12/05 FOR | | PTE STRAND 2ND TO 7TH FLOOR POST-TENSION | | CABLE SHOP DRAWINGS. | | | | --PROVISO-- | | COMPLY WITH ENGIEER OF RECORD COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
51 |
Status |
P |
Date |
2005-04-08 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-04-08 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-04-08 |
Time |
10:18 |
Sent To |
|
|
Notes |
2005-04-08 00:00:00 | STRUCTURAL SUBMITTAL ON 3/31/05 FOR POUR | | 1, 5TH LEVEL SHORING INSPECTION LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
50 |
Status |
P |
Date |
2005-03-30 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-30 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-30 |
Time |
14:38 |
Sent To |
|
|
Notes |
2005-03-30 00:00:00 | STRUCTURAL SUBMITTAL ON 3/4/05 FOR POUR | | 1, 3RD LEVEL SHORING INSPECTION LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
49 |
Status |
P |
Date |
2005-03-30 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-30 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-30 |
Time |
14:34 |
Sent To |
|
|
Notes |
2005-03-30 00:00:00 | STRUCTURAL SUBMITTAL ON 3/4/05 FOR POUR | | 3, 2ND LEVEL SHORING INSPECTION LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
48 |
Status |
P |
Date |
2005-03-30 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-30 |
Time |
12:18 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-30 |
Time |
12:17 |
Sent To |
|
|
Notes |
2005-03-30 00:00:00 | STRUCTURAL SUBMITTAL ON 3/24/05 FOR | | SKYLINE STEEL FABRICATORS, 1ST FLOOR AND | | POOL DECK, STEEL DECKING SHOP DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
47 |
Status |
P |
Date |
2005-03-30 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-30 |
Time |
12:06 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-30 |
Time |
12:06 |
Sent To |
|
|
Notes |
2005-03-30 00:00:00 | STRUCTURAL SUBMITTAL ON 3/21/05 FOR POUR | | 1, 4TH LEVEL SHORING INSPECTION LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
46 |
Status |
P |
Date |
2005-03-30 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-30 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-30 |
Time |
11:18 |
Sent To |
|
|
Notes |
2005-03-30 00:00:00 | STRUCTURAL SUBMITTAL ON 3/16/05 FOR POUR | | 3, 3RD LEVEL SHORING INSPECTION LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
45 |
Status |
F |
Date |
2005-03-29 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-29 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-29 |
Time |
16:20 |
Sent To |
|
|
Notes |
2005-03-29 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | STRUCTURAL SUBMITTAL ON 3/10/05 FOR | | SHARON STAIRS 'DROP-IN' STAIR SYSTEM | | SHOP DRAWINGS. | | | | 1) THIS IS A STRUCTURAL SUBMITTAL AND | | NOTE 3 ON SHEETS D10 AND KLP STATES "THE | | ENGINEER OF RECORD SHALL CHECK THE | | ADEQUACY OF THE BUILDING COMPONENTS DUE | | TO........". | | THE ENGINEER OF RECORD SHALL REVIEW AND | | STAMP, OR PROVIDE A SIGNED AND SEALED | | COVER LETTER MAKING SPECIFIC REFERENCE | | TO, THE SUBMITTED STRUCTURAL | | DOCUMENT(S). | | | | 2) 61G15-23.002(1)FL. ADMIN. CODE. | | THE SUBMITTED CALCULATION INDEX SHEET | | DOES NOT BEAR THE ORIGINAL SIGNATURE, | | RAISED SEAL OR PRINTED LICENSE NUMBER OF | | STEVEN W.SCHAUB, P.E. | | DOCUMENTS SUBMITTED BY AN ENGINEER FOR | | PUBLIC RECORD SHALL BEAR THE SIGNATURE | | AND SEAL OF THE ENGINEER. (471.025 F.S.) | | | | 3) BECAUSE SHARON STAIRS DOES NOT HAVE A | | STATE ENGINEERING BUSINESS (CERTIFICATE | | OF AUTHORIZATION) NUMBER, STEVEN W. | | SCHAUB, P.E. IS THE SOLE RESPONSIBLE | | ENGINEER AND HIS PRINTED NAME, LICENSE | | NUMBER (P.E. #60509) AND ADDRESS (5800 | | EAST THOMAS ROAD, STE 104, SCOTTSDALE | | ARIZONA85251) MUST BE INDICATED ON | | EACH SHEET.THIS INFORMATION MAY BE | | HANDWRITTEN OR STAMPED ON THE PLANS IF | | THE ENGINEER DOES NOT INCLUDE IT IN HIS | | TITLE BLOCK.TO EXPEDITE THIS SUBMITTAL | | ONLY, THE CONTRACTOR MAY OPT TO ADD THE | | ENGINEER'S NAME, LICENSE NUMBER AND | | ADDRESS TO EACH SHEET. | | | | NOTE:61G15-23.002(2)FL. ADMIN. CODE. | | PLANS SIGNED & SEALED BY A PROFESSIONAL | | ENGINEER SHALL INCLUDE EITHER THE NAME, | | ADDRESS AND LICENSE NUMBER OF THE | | ENGINEER OR, THE NAME AND LICENSE NUMBER | | OF THE ENGINEER AND THE NAME, ADDRESS | | AND CERTIFICATE OF AUTHORIZATION NUMBER | | OF THE ENGINEERING BUSINESS THROUGH | | WHICH THE ENGINEER IS PRACTICING | | (471.025 F.S. AND 471.023 F.S.). | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
44 |
Status |
P |
Date |
2005-03-29 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-29 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-29 |
Time |
15:40 |
Sent To |
|
|
Notes |
2005-03-29 00:00:00 | STRUCTURAL SUBMITTAL ON 3/10/05 FOR | | CECO CONCRETE CONSTRUCTION 2ND TO 7TH | | FLOOR SHORING SHOP DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
43 |
Status |
P |
Date |
2005-03-29 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-29 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-29 |
Time |
15:36 |
Sent To |
|
|
Notes |
2005-03-29 00:00:00 | STRUCTURAL SUBMITTAL ON 3/10/05 FOR | | KUREZ DR VOX DISSIPATING CONCRETE CURING | | COMPOUND MANUFACTURER'S DATA. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
42 |
Status |
P |
Date |
2005-03-23 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-23 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-23 |
Time |
17:00 |
Sent To |
|
|
Notes |
2005-03-23 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | STRUCTURAL SUBMITTAL ON 2/24/05 FOR | | PTE STRAND 3RD TO 7TH FLOOR POST-TENSION | | CABLE SHOP DRAWINGS. | | | | --PROVISO-- | | COMPLY WITH ENGIEER OF RECORD COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
41 |
Status |
P |
Date |
2005-03-23 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-23 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-23 |
Time |
16:48 |
Sent To |
|
|
Notes |
2005-03-23 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | STRUCTURAL SUBMITTAL ON 2/24/05 FOR | | GULFSTREAM 3RD TO 7TH FLOOR | | REINFORCEMENT SHOP DRAWINGS | | | | --PROVISO-- | | COMPLY WITH ENGIEER OF RECORD COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
40 |
Status |
P |
Date |
2005-03-23 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-23 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-23 |
Time |
16:18 |
Sent To |
|
|
Notes |
2005-03-23 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | STRUCTURAL SUBMITTAL ON 2/24/05 FOR | | GULFSTREAM 2ND FLOOR REINFORCEMENT SHOP | | DRAWINGS | | | | --PROVISO-- | | COMPLY WITH ENGIEER OF RECORD COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
39 |
Status |
P |
Date |
2005-03-23 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-23 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-23 |
Time |
15:39 |
Sent To |
|
|
Notes |
2005-03-23 00:00:00 | STRUCTURAL SUBMITTAL ON 2/24/05 FOR POUR | | 2, 2ND LEVEL SHORING INSPECTION LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
38 |
Status |
P |
Date |
2005-02-18 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-02-18 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-02-18 |
Time |
10:39 |
Sent To |
|
|
Notes |
2005-02-18 00:00:00 | STRUCTURAL SUBMITTAL ON 2/17/05 FOR | | POUR 1, 2ND LEVEL SLAB SHORING | | INSPECTION LETTERS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
37 |
Status |
F |
Date |
2005-02-10 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-02-10 |
Time |
17:46 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-02-10 |
Time |
17:46 |
Sent To |
|
|
Notes |
2005-02-10 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | STRUCTURAL SUBMITTAL ON 2/9/05 FOR PTE | | STRAND POST-TENSION SHOP DRAWINGS PT-1, | | 02 AND 03 (GENERAL NOTES AND 2ND LEVEL | | PLANS). | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | F.S.= FLORIDA (STATE) STATUTE | | | | 1) FBC 3502SHEET PT-1, NOTE 2 - | | ANCHORAGES CITES TO OUTDATED | | REFERENCES, | | STANDARD BUILDING CODE AND ACI 318-83. | | THE APPLICABLE CODE IS FLORIDA BUILDING | | CODE 2001 AND THE CODE REFERENCED | | VERSION OF THE STANDARD FOR STRUCTURAL | | CONCRETE IS ACI 318-02.AMEND THE | | NOTES | | TO CITE TO THE CURRENT CODE AND | | STANDARD. | | | | 2) 61G15-23.002(2)FL. ADMIN. CODE. | | ALL THREE COPIES OF SHEETS PT-02 AND | | PT-03 ARE PHOTOCOPIED AFTER | | SIGNATURE/SEAL.PLANS SIGNED & SEALED | | BY A PROFESSIONAL ENGINEER FOR PUBLIC | | RECORD SHALL INCLUDE THE ORIGINAL | | SIGNATURE AND SEAL OF THE ENGINEER | | (471.025 F.S.) | | | | 3) 61G15-23.002(2)FL. ADMIN. CODE. | | IT | | IS NOTED THAT THE ADDRESS OF PTE STRAND | | CO., INC. IS STATED ON THE PLANS, BUT | | THE FIRM DOES NOT HAVE A CERTIFICATE OF | | AUTHORIZATION NUMBER, ISSUED BY THE | | BOARD OF ENGINEERS, SO THE ADDRESS OF | | MIAN A. HAMID P.E. MUST BE PRINTED ON | | THE PLANS.THIS CAN BE ADDED BY HAND. | | PLANS SIGNED & SEALED BY A PROFESSIONAL | | ENGINEER SHALL INCLUDE EITHER THE NAME, | | ADDRESS AND LICENSE NUMBER OF THE | | ENGINEER OR, THE NAME AND LICENSE | | NUMBER | | OF THE ENGINEER AND THE NAME, ADDRESS | | AND CERTIFICATE OF AUTHORIZATION NUMBER | | OF THE ENGINEERING BUSINESS THROUGH | | WHICH THE ENGINEER IS PRACTICING | | (471.025 F.S. AND 471.023 F.S.). | | | | 4) THE ABOVE IS APPLICABLE TO ALL | | STRUCTURAL SHOP DRAWING SUBMITTALS | | REQUIRED TO BE SEALED BY THE | | RESPONSIBLE | | ENGINEER. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL | | INFO | | TELEPHONE: (561) 805 6716ROBERT | | BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
36 |
Status |
P |
Date |
2005-02-08 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-02-08 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-02-08 |
Time |
09:57 |
Sent To |
|
|
Notes |
2005-02-08 00:00:00 | STRUCTURAL SUBMITTAL ON 2/3/05 FOR CECO | | CONSTRUCTION 2ND THRU 7TH FLOOR SLAB | | FORMWORK DRAWINGS | | | | --PROVISO-- | | COMPLY WITH THE ARCHITECT OF RECORD'S | | COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
35 |
Status |
P |
Date |
2005-02-08 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-02-08 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-02-08 |
Time |
09:51 |
Sent To |
|
|
Notes |
2005-02-08 00:00:00 | ARCHITECTURAL SUBMITTAL ON 2/3/05 FOR | | MANUFACTURER'S DATA ON DRYWALL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
34 |
Status |
P |
Date |
2005-02-08 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-02-08 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-02-08 |
Time |
09:48 |
Sent To |
|
|
Notes |
2005-02-08 00:00:00 | STRUCTURAL SUBMITTAL ON 2/3/05 FOR CECO | | CONSTRUCTION GROUND FLOOR TRANSFER SLAB | | SHORING DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
33 |
Status |
P |
Date |
2005-02-08 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-02-08 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-02-08 |
Time |
09:40 |
Sent To |
|
|
Notes |
2005-02-08 00:00:00 | STRUCTURAL SUBMITTAL ON 2/3/05 FOR GULF | | STREAM GROUND FLOOR TOP BAR FOR POURS 3 | | & 4, ADDITIONAL TOP BARS AND COLUMN | | DOWELS. | | | | --PROVISO-- | | COMPLY WITH THE ENGINEER OF RECORD'S | | COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
32 |
Status |
P |
Date |
2005-02-07 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-02-07 |
Time |
18:28 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-02-07 |
Time |
18:28 |
Sent To |
|
|
Notes |
2005-02-07 00:00:00 | ARCHITECTURAL SUBMITTAL ON 1/28/05 FOR | | COHEN FREEDMAN ENCINOSA AND ASSOCS | | LETTER DATED 1/13/05 RE: 3/4" SLAB | | DEPRESSION |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
31 |
Status |
P |
Date |
2005-02-07 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-02-07 |
Time |
18:27 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-02-07 |
Time |
18:27 |
Sent To |
|
|
Notes |
2005-02-07 00:00:00 | STRUCTURAL SUBMITTAL ON 1/21/05 FOR | | GULF | | STREAM GROUND FLOOR TRANSFER SLAB SHEAR | | AND OPENING REINFORCEMENT. | | | | --PROVISO-- | | COMPLY WITH THE ENGINEER OF RECORD'S | | COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
30 |
Status |
P |
Date |
2005-02-07 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-02-07 |
Time |
18:25 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-02-07 |
Time |
18:25 |
Sent To |
|
|
Notes |
2005-02-07 00:00:00 | STRUCTURAL SUBMITTAL ON 1/21/05 FOR | | GULF | | STREAM GROUND FLOOR TRANSFER SLAB | | BOTTOM | | REINFORCEMENT. | | | | --PROVISO-- | | COMPLY WITH THE ENGINEER OF RECORD'S | | COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
29 |
Status |
P |
Date |
2005-02-07 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-02-07 |
Time |
18:23 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-02-07 |
Time |
18:23 |
Sent To |
|
|
Notes |
2005-02-07 00:00:00 | STRUCTURAL SUBMITTAL ON 1/21/05 FOR | | CECO | | CONSTRUCTION GROUND FLOOR TRANSFER SLAB | | FORMWORK DRAWINGS. | | | | --PROVISO-- | | COMPLY WITH THE ARCHITECT OF RECORD'S | | COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
28 |
Status |
P |
Date |
2005-01-18 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-01-18 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-01-18 |
Time |
14:44 |
Sent To |
|
|
Notes |
2005-01-18 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | STRUCTURAL SUBMITTAL ON 1/14/05 FOR | | GULF STREAM SHEAR WALL AND COLUMN | | SCHEDULE AND COLUMN PLAN. | | | | --PROVISO-- | | COMPLY WITH THE ENGINEER OF RECORD'S | | COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
27 |
Status |
P |
Date |
2004-12-21 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-12-21 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-12-21 |
Time |
09:47 |
Sent To |
|
|
Notes |
2004-12-21 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | STRUCTURAL SUBMITTAL ON 12/20/04 FOR | | CECO CONCRETE CONSTRUCTION SHOP | | DRAWINGS. | | | | --PROVIS0-- | | BECAUSE CECO CONCRETE CONSTRUCTION DOES | | NOT HAVE A STATE ENGINEERING BUSINESS | | (CERTIFICATE OF AUTHORIZATION) NUMBER, | | AUBREY L. DUNHAM, P.E. IS THE SOLE | | RESPONSIBLE ENGINEER AND HIS ADDRESS | | MUST BE INDICATED ON EACH SHEET.FOR | | THIS SUBMITTAL ONLY, THE ADDRESS HAS | | BEEN ADDED AS A PROVISO.IF THE | | ENGINEER'S ADDRESS DOES NOT APPEAR ON | | FUTURE SUBMITTALS THEY WILL BE DENIED. | | THIS INFORMATION MAY BE HANDWRITTEN OR | | STAMPED ON THE PLANS IF THE ENGINEER | | DOES NOT INCLUDE IT IN HIS TITLE BLOCK. | | | | NOTE:61G15-23.002(2)FL. ADMIN. CODE. | | PLANS SIGNED & SEALED BY A PROFESSIONAL | | ENGINEER SHALL INCLUDE EITHER THE NAME, | | ADDRESS AND LICENSE NUMBER OF THE | | ENGINEER OR, THE NAME AND LICENSE NUMBER | | OF THE ENGINEER AND THE NAME, ADDRESS | | AND CERTIFICATE OF AUTHORIZATION NUMBER | | OF THE ENGINEERING BUSINESS THROUGH | | WHICH THE ENGINEER IS PRACTICING | | (471.025 F.S. AND 471.023 F.S.). |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
26 |
Status |
P |
Date |
2004-12-17 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-12-17 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-12-17 |
Time |
17:56 |
Sent To |
|
|
Notes |
2004-12-17 00:00:00 | STRUCTURAL SUBMITTAL ON 12/13/04 FOR | | GULF STREAM B-1 LEVEL SLAB REINFORCEMENT | | SHOP DRAWING |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
25 |
Status |
P |
Date |
2004-12-17 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-12-17 |
Time |
17:54 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-12-17 |
Time |
17:54 |
Sent To |
|
|
Notes |
2004-12-17 00:00:00 | STRUCTURAL SUBMITTAL ON 12/13/04 FOR | | FOUNDATION SLAB CONSTRUCTION JOINT | | LOCATIONS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
24 |
Status |
P |
Date |
2004-12-17 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-12-17 |
Time |
17:54 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-12-17 |
Time |
17:53 |
Sent To |
|
|
Notes |
2004-12-17 00:00:00 | STRUCTURAL SUBMITTAL ON 12/13/04 FOR | | GALVANIZED REINFORCING STEEL PRODUCT | | DATA |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
23 |
Status |
P |
Date |
2004-12-17 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-12-17 |
Time |
17:53 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-12-17 |
Time |
17:53 |
Sent To |
|
|
Notes |
2004-12-17 00:00:00 | STRUCTURAL SUBMITTAL ON 12/13/04 FOR | | WELDED WIRE MESH PRODUCT DATA |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
22 |
Status |
P |
Date |
2004-12-17 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-12-17 |
Time |
17:50 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-12-17 |
Time |
17:50 |
Sent To |
|
|
Notes |
2004-12-17 00:00:00 | STRUCTURAL SUBMITTAL ON 12/13/04 FOR | | GALVANIZED TIE WIRE PRODUCT DATA |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
21 |
Status |
P |
Date |
2004-12-02 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-12-02 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-12-02 |
Time |
10:36 |
Sent To |
|
|
Notes |
2004-12-02 00:00:00 | STRUCTURAL REVISION SUBMITTED 11/19/04 | | FOR SHEETS S-3, S-19 AND S-21 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
20 |
Status |
P |
Date |
2004-12-01 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-12-01 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-12-01 |
Time |
12:45 |
Sent To |
|
|
Notes |
2004-12-01 00:00:00 | STRUCTURAL SUBMITTAL ON 12/1/04 FOR | | CONCRETE WATERSTOP PRODUCT INFO SHEETS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
19 |
Status |
P |
Date |
2004-11-17 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-11-17 |
Time |
17:37 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-11-17 |
Time |
17:36 |
Sent To |
|
|
Notes |
2004-11-17 00:00:00 | STRUCTURAL SUBMITTAL ON 11/16/04 FOR | | CECO CONCRETE CONSTRUCTION SHOP | | DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
18 |
Status |
P |
Date |
2004-11-17 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-11-17 |
Time |
17:27 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-11-17 |
Time |
17:27 |
Sent To |
|
|
Notes |
2004-11-17 00:00:00 | STRUCTURAL SUBMITTAL ON 11/16/04 FOR | | URS | | CORPORATION SHEET PILE WALL DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
17 |
Status |
P |
Date |
2004-11-17 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-11-17 |
Time |
17:25 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-11-17 |
Time |
17:27 |
Sent To |
|
|
Notes |
2004-11-17 00:00:00 | STRUCTURAL SUBMITTAL ON 11/16/04 FOR | | ARDAMAN ASSOCIATES LETTER DATED 11/11/04 | | RE: 'HJ FOUNDATIONS' VIBROFLOTATION |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
16 |
Status |
P |
Date |
2004-11-17 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-11-17 |
Time |
17:22 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-11-17 |
Time |
17:22 |
Sent To |
|
|
Notes |
2004-11-17 00:00:00 | STRUCTURAL SUBMITTAL ON 11/16/04 FOR | | ARDAMAN ASSOCIATES LETTER DATED 9/29/04 | | RE: 'HJ FOUNDATIONS' VIBROFLOTATION |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
15 |
Status |
P |
Date |
2004-11-17 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-11-17 |
Time |
17:21 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-11-17 |
Time |
17:21 |
Sent To |
|
|
Notes |
2004-11-17 00:00:00 | STRUCTURAL SUBMITTAL ON 11/16/04 FOR | | HILTI ANCHOR SPEC |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
14 |
Status |
P |
Date |
2004-11-17 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-11-17 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-11-17 |
Time |
17:18 |
Sent To |
|
|
Notes |
2004-11-17 00:00:00 | STRUCTURAL SUBMITTAL ON 11/16/04 FOR | | CONCRETE REPAIR MORTAR SPEC |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
13 |
Status |
P |
Date |
2004-11-10 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-11-10 |
Time |
17:05 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-11-10 |
Time |
10:12 |
Sent To |
|
|
Notes |
2004-11-10 00:00:00 | STRUCTURAL SUBMITTAL ON 11/2/04 FOR | | FOOTING AND PARKING LEVEL SLAB, WALL AND | | COLUMN REINFORCEMENT CUT SHEETS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
12 |
Status |
P |
Date |
2004-11-10 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-11-10 |
Time |
17:02 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-11-10 |
Time |
17:02 |
Sent To |
|
|
Notes |
2004-11-10 00:00:00 | STRUCTURAL SUBMITTAL ON 11/2/04 FOR | | CONCRETE MIX DESIGNS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
11 |
Status |
P |
Date |
2004-11-10 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-11-10 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-11-10 |
Time |
16:59 |
Sent To |
|
|
Notes |
2004-11-10 00:00:00 | STRUCTURAL SUBMITTAL ON 11/2/04 FOR SLAB | | CONSTRUCTION JOINT LOCATIONS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
10 |
Status |
P |
Date |
2004-11-10 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-11-10 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-11-10 |
Time |
16:57 |
Sent To |
|
|
Notes |
2004-11-10 00:00:00 | STRUCTURAL SUBMITTAL ON 11/2/04 FOR WALL | | WATERPROOFING BENTONITE PRODUCT INFO | | SHEETS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
9 |
Status |
P |
Date |
2004-11-10 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-11-10 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-11-10 |
Time |
16:49 |
Sent To |
|
|
Notes |
2004-11-10 00:00:00 | STRUCTURAL SUBMITTAL ON 11/2/04 FOR WALL | | WATERPROOFING PRODUCT INFO SHEETS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
P |
Date |
2004-10-08 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-10-08 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-10-08 |
Time |
15:35 |
Sent To |
|
|
Notes |
2004-10-08 00:00:00 | STRUCTURAL REVISION SUBMITTED ON 9/30/04 | | FOR CHM PLANS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2004-09-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-05 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-09-17 |
Time |
16:58 |
Sent To |
|
|
Notes |
2004-09-17 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | STRUCTURAL SUBMITTAL ON 8/26/04 FOR | | SHEETPILE RETAINING WALL. | | | | --PROVISO-- | | STRUCTURAL DRG/CALC SUBMITTALS SHALL BE | | REVIEWED AND STAMPED BY THE ENGINEER OF | | RECORD (CHM, MIAMI FL). |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2004-06-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-26 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-06-25 |
Time |
13:59 |
Sent To |
|
|
Notes |
2004-06-25 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | NOTE: | | THREE COPIES OF ACHITECTURAL SHEETS | | A.02, A.03, A.35 AND LS.5 WERE AMENDED, | | SIGNED AND DATED BY GUILLERMO ENCINOSA | | (ARCHITECT OF RECORD) HY HAND ON 6/23/04 | | | | --PROVISO-- | | SUBMIT METAL LOUVERED DOOR PRODUCT | | APPROVALS FOR DOORS WITH DESIGN PRESSURE | | RATINGS OF AT LEAST +70 PSF AND -80 PSF. | | SHEET A.48, DOOR SCHEDULE, SHOWS | | LOUVERED DOORS (TYPE H AND G) FOR DOORS | | 43, 93 AND 94 (TO THE GENERATOR, BOILER | | AND PUMP ROOMS).THE SUBMITTED CURRIES | | COMPANY PRODUCT APPROVAL NOA# 03-0319.04 | | HAS A MAXIMUM DESIGN PRESSURE RATING OF | | ONLY +50 PSF AND -50 PSF. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2004-06-23 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-06-23 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-06-23 |
Time |
17:56 |
Sent To |
Z |
|
Notes |
2004-06-23 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | NOTE: | | THREE COPIES OF ARCHITECTURAL SHEETS | | A.02, A.03, A.35AND LS.5 WERE AMENDED, | | SIGNED AND DATED BY GUILLERMO ENCINOSA | | (ARCHITECT OF RECORD) BY HAND ON 6/23/04 | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | ARE NUMBERED AS PER THE BUILDING PLAN | | REVIEW OF 4/16/04: | | | | 1) THE COMMENT RESPONSE, DATED 5/8/04, | | IS NOTED. | | THE NOTICE OF COMMENCEMENT SHALL BE | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | AND A COPY SUBMITTED TO THIS OFFICE | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | 2) THE COMMENT RESPONSE, DATED 5/8/04, | | IS NOTED. | | IMPACT FEES. THE PLANS SHALL BE TAKEN | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | STAMPED AT THAT OFFICE AND A COPY OF THE | | PAID RECEIPT SUBMITTED TO THE CITY OF | | WEST PALM BEACH DEPT OF CONSTRUCTION | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | 4) DECLARATION OF CONDOMINIUM BEFORE | | C.O. ISSUE.THE COMMENT RESPONSE, DATED | | 5/8/04 IS NOTED. | | | | 6) FBC* 105.13.1SPECIAL INSPECTOR. | | THIS COMMENT HAS NOT BEEN ADDRESSED. THE | | 'SPECIAL INSPECTOR AGREEMENT' WAS NOT | | RE-SUBMITTED.REPEATING THE COMMENTS | | FROM THE PREVIOUS REVIEW, THE SUBMITTED | | 'SPECIAL INSPECTOR AGREEMENT' IS MISSING | | THE LAST PAGE, WHICH IS TO BE SIGNED BY | | THE CONTRACTOR AND ARCHITECT/ENGINEER | | THE AGREEMENT SHALL ALSO BE SIGNEED BY T | | HE OWNER AND JOB INSPECTOR IN THE SPACE | | ALLOCATED.ALL SIGNATURES ARE TO BE | | NOTARIZED ORIGINALS. | | | | 7) SEPARATE SWIMMING POOL PERMIT APPLIC. | | THE COMMENT RESPONSE, DATED 5/8/04, IS | | NOTED. | | | | 9) FBC 13-103.1.2ENERGY CODE | | COMPLIANCE FORMS.THE COMMENT RESPONSE | | DATED 5/8/04, IS NOTED BUT SHEET 2 OF | | THE SUBMITTED ENERGY CODE COMPLIANCE | | FORMS SHALL BE SIGNED BY A KENCO | | COMMUNITIES REPRESENTATIVE AS 'OWNER', | | TO CERTIFY COMPLIANCE. | | | | 11) PRODUCT APPROVALS.THIS COMMENT HAS | | NOT BEEN PROPERLY ADDRESSED. | | NO PRODUCT APPROVALS HAVE BEEN SUBMITTED | | FOR THE ROOFING PRODUCTS, STOREFRONT AND | | HOLLOW METAL, LOUVERED, FLUSH (SINGLE | | AND DOUBLE AND ALUMINUM GLAZED SWING | | (SINGLE AND DOUBLE) EXTERIOR DOORS. | | | | 50) SHEET A.29PRE-CAST CONCRETE | | ARCHITECTURAL FEATURES/MOLDINGS.ONE | | OF THE THREE SETS OF PLANS STILL HAS | | THE 'OLD' REVISION OF SHEET A.29. INSERT | | THE LATEST REVISION AND REMOVE THE 'OLD' | | SHEET. | | | | 52) FBC 412.5(3)SHEET M4.01, SMOKE | | CONTROL NOTE C.THIS COMMENT HAS NOT | | BEEN PROPERLY ADDRESSED.THE REVISION | | MADE IS NOTED BUT THE NOTE C STILL DOES | | NOT MAKE SENSE AND DOES NOT CLEARLY | | EXPRESS THE ENGINEER'S INTENT.PLEASE | | READ THE NOTE AND CONSIDER THAT IT MAY | | BE CLARIFIED BY: | | - DELETING THE WORDS "..THROUGH THE..." | | FROM THE SECOND SENTENCE. | | - REPLACING THE WORDS "TO CLOSE AND..." | | WITH "IT SHALL ALSO..." AT THE BEGINNING | | OF THE LAST SENTENCE. | | | | 53) FBC 1005.6.9.9SHEET M4.01, SMOKE | | CONTROL NOTE 3B - STAIR BAROMETRIC | | RELIEF.THIS COMMENT HAS NOT BEEN | | PROPERLY ADDRESSED. THE REVISION MADE IS | | NOTED BUT THE NOTE SPECIFIES A MINIMUM | | PRESSURE DIFFERENCE OF 0.35"WG WHILE | | FBC 1005.6.9.9 REQUIRES A PRESSURE | | DIFFERENCE OF 0.05"WG MINIMUM AND | | 0.35"WG MAXIMUM.AMEND THE NOTE TO | | DEMONSTRATE COMPLIANCE. | | | | 54) TO EXPEDITE REVIEW OF A RESUBMITTAL | | WHICH REQUIRES NEW PLANS IN ORDER TO | | ADDRESS THE ABOVE COMMENTS, THE OLD | | SHEETS SHALL BE REMOVED AND THE NEW | | SHEETS INSERTED.ONE COPY OF EACH OLD | | SHEET SHOULD BE STAPLED/CLIPPED TO THE | | REMAINING OLD SHEETS FOR COMPARISON OF | | REVISIONS WHEN REVIEWING THE RESUBMITTED | | PLANS. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2004-04-16 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-04-16 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-04-14 |
Time |
10:44 |
Sent To |
|
|
Notes |
2004-04-14 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | NOTE: | | CHAPTER 553.80(2)(B) FLORIDA STATUTES | | STATES THAT A LOCAL GOVERNMENT SHALL | | IMPOSE A FEE OF FOUR TIMES THE FEE FOR | | PLAN REVIEW, IF PLANS ARE REJECTED THREE | | OR MORE TIMES FOR REPEATED FAILURE TO | | CORRECT A CODE VIOLATION. | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | ARE NUMBERED AS PER THE BUILDING PLAN | | REVIEW OF 11/21/03: | | | | 1) THE COMMENT RESPONSE, DATED 2/11/04, | | IS NOTED. | | THE NOTICE OF COMMENCEMENT SHALL BE | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | AND A COPY SUBMITTED TO THIS OFFICE | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | 2) THE COMMENT RESPONSE, DATED 2/11/04, | | IS NOTED. | | IMPACT FEES. THE PLANS SHALL BE TAKEN | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | STAMPED AT THAT OFFICE AND A COPY OF THE | | PAID RECEIPT SUBMITTED TO THE CITY OF | | WEST PALM BEACH DEPT OF CONSTRUCTION | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | 3) UNITY OF TITLE. THE COMMENT RESPONSE, | | DATED 2/11/04, IS NOTED BUT THE COMMENT | | HAS NOT BEEN PROPERLY ADDRESSED.PALM | | BEACH COUNTY PROPERTY APPRAISERS OFFICE | | (HTTP://WWW.CO.PALM-BEACH.FL.US/PAPA/) | | SHOWS THE PROPOSED BUILDING STRUCTURE | | TRANSGRESSES LEGAL BOUNDARY LINES | | BETWEEN THREE LOTS (PCN: 74-43-43-21-01- | | 033-0011, 74-43-43-21-01-033-0012 AND | | 74-43-43-21-10-074-0010)WHICH FORM THE | | 'THE SITE'.SUBMIT A COPY OF THE 'UNITY | | OF TITLE' DOCUMENT SO THAT FBC TABLE 600 | | BOUNDARY LINE REQUIREMENTS MAY BE DEEMED | | NOT APPLICABLE. | | | | 4) DECLARATION OF CONDOMINIUM BEFORE | | C.O. ISSUE.THE COMMENT RESPONSE, DATED | | 2/11/04, IS NOTED. | | | | 6)FBC* 105.13.1SPECIAL INSPECTOR. | | THIS COMMENT HAS NOT BEEN PROPERLY | | ADDRESSED.THE SUBMITTED 'SPECIAL | | INSPECTOR AGREEMENT' IS MISSING THE LAST | | PAGE, WHICH IS TO BE SIGNED BY THE | | CONTRACTOR AND ARCHITECT/ENGINEER.THE | | AGREEMENT SHALL ALSO BE SIGNED BY THE | | OWNER AND THE JOB INSPECTOR IN THE SPACE | | ALLOCATED.ALL SIGNATURES ARE TO BE | | NOTARIZED ORIGINALS.ALSO, ON SHEET S-0 | | THE DRAWING LIST UNDER THE HEADING | | 'THRESHOLD BUILDING INSPECTION PLAN | | SHALL INCLUDE ALL RELEVANT ARCHITECTURAL | | SHEETS SUCH AS A.68, A.69, A.70, A.71. | | | | 7) SEPARATE SWIMMING POOL PERMIT APPLIC. | | THE COMMENT RESPONSE, DATED 2/11/04, IS | | NOTED. | | | | 9) FBC 104.2.2ENERGY CODE COMPLIANCE | | FORMS.THE COMMENT RESPONSE, DATED | | 2/11/04, IS NOTED. SHEET 2 OF THE | | SUBMITTED FORM SHALL HAVE THE ORIGINAL | | SEAL AND WET SIGNATURE OF ENGINEER THAT | | PREPARED IT (STEVEN FELLER P.E.).ALSO, | | SHEET 1 SHALL INCLUDE THE PERMIT NUMBER | | (03050107), ADDRESS (403 SAPODILLA AVE), | | ZIP (33401).THREE COPIES ARE REQUIRED. | | | | 11) PRODUCT APPROVALS.THIS COMMENT HAS | | NOT BEEN PROPERLY ADDRESSED.NO PRODUCT | | APPROVALS HAVE BEEN SUBMITTED FOR THE | | ROOFING PRODUCTS.THE SUBMITTED MIAMI | | WALL SYSTEMS INC PRODUCT APPROVAL NOA'S | | FOR THE SINGLE HUNG WINDOWS AND SLIDING | | GLASS DOORS DO NOT INCLUDE THE DRAWING | | SHEETS WHICH FORM PART OF THE APPROVAL. | | THE SUBMITTED FLEMING DOOR PRODUCTS LTD | | OUTSWING COMMERCIAL STEEL DOOR PRODUCT | | APPROVAL NOA# 02-0523.06 INCLUDES | | DRAWINGS WHICH DO NOT INCLUDE THE | | REQUIRED MIAMI-DADE PRODUCT CONTROL | | DIVISION APPROVAL STAMP.ALSO, SUBMIT | | THREE COPIES OF COMPLETE PRODUCT | | APPROVALS FOR ALL OF THE PROPOSED | | WINDOW, STOREFRONT, EXTERIOR DOOR AND | | ROOF PRODUCTS. | | | | 12) FBC* 104.2.1.2BUILDING DATA.THIS | | COMMENT HAS NOT BEEN PROPERLY ADDRESSED. | | SHEET A.01 SHOWS A NEW HEADING 'BUILDING | | AREA' BUT NO BUILDING AREA INFO, EXCEPT | | THE AREAS OF THE RESIDENTIAL UNIT TYPES, | | HAS BEEN ADDED.ADD THE BUILDING AREA | | INFO. | | NOTE:THE STATED VALUATION FOR PERMIT | | APPLICATION FEE CALCULATION HAS NOT YET | | BEEN REVIEWED DUE TO THE LACK OF THIS | | INFORMATION.ADDITIONAL FEES MAY BE | | DUE (SEE FBC* 104.6.5). | | | | 13) FBC 1606.1.1WIND LOAD. THE COMMENT | | RESPONSE, DATED 2/11/04, IS NOTED. | | SUBMIT COPIES OF THE RWDI WIND TUNNEL | | TEST REPORT REFERENCED ON SHEET S-0 | | UNDER THE TITLE 'WIND LOADS'.ADD A | | TITLE AND KEY TO SHEETS A.68, A.69, | | A.70 AND A.71 TO CLARIFY WHETHER THAT | | INFORMATION REPRESENTS COMPONENT AND | | CLADDING WIND PRESSURES IN PSF. | | | | 18) FBC 412.6SHEETS A.02 AND A.03, | | PARKING LEVEL PLANS. IF DOOR #7 IS BEING | | PROVIDED IN FRONT OF EACH ELEVATOR, IN | | LIEU OF ELEVATOR LOBBIES, HOW IS THE | | REQUIREMENT FOR A SMOKE DETECTOR IN EACH | | ELEVATOR LOBBY (REF: FBC 412.6.3) GOING | | TO BE MET?AMEND THE PLANS (INCL. | | SHEETS LS.1 AND LS.2) | | | | 34) FBC 411.2.3PARKING GARAGE LOADING. | | THE 2/11/04 COMMENT RESPONSE AND REVISED | | ARCHITECTURAL SHEET A.03 REFER TO THE | | STRUCTURAL PLANS FOR PARKING GARAGE | | IMPACT LOADING.NO REFERNCE TO THIS | | LOADING COULD BE FOUND ON THE STRUCTURAL | | PLANS.PLEASE CLARIFY. | | | | 41) FBC 1010.1SHEETS LS.2 AND A.04. | | ROUTE TO EXIT DISCHARGE FROM STAIR #4. | | SHEET LS.2 SHOWS TWO STAIRS WHILE | | SHEET A.04 & A.15 SHOW ONE.ALSO, SHOW | | DIMENSIONS FOR THE WIDTH OF THE STAIRS | | AND ASSOCIATED GATE, AND PROVIDE TREAD/ | | RISER DETAILS FOR THE STAIRS. | | | | 42) SHEET S-17, UPPER LEVEL ROOF PLAN. | | AS THE RWDI WIND TUNNEL TEST REPORT HAS | | NOT BEEN SUBMITTED (SEE COMMENT 13) THE | | UPLIFTS ON THE ROOF TRUSSES CANNOT BE | | VERIFIED AT THIS TIME. | | | | 45) 61G1-16.004FL. ADMIN. CODE.PLANS | | PREPARED BY A REGISTERED ARCHITECT SHALL | | INCLUDE THE PRINTED NAME OF THE | | ARCHITECT SEALING THE PLANS.THE | | PRINTED NAME AND LICENSE NUMBER ARE FOR | | GUILLERMO J. ENCINOSA BUT THE PLANS ARE | | SIGNED AND SEALED BY STUART COHEN.THE | | PRINTED NAME AND LICENSE NUMBER OF THE | | ARCHITECT MUST MATCH THE SIGNATURE AND | | SEAL ON THE PLANS. | | | | 46) FBC 1003.3EGRESS CAPACITY.AMEND | | THE LIFE SAFETY PLANS LS.1 TO LS.5 (LS.2 | | IN PARTICULAR) TO SHOW THE CALCULATED | | NUMBER OF OCCUPANT USING EACH EXIT. | | | | 47) FBC 1012.1EXTERIOR DOOR (#78) TO | | SOUTH EAST PLAZA.THE WIDTH OF THE EXIT | | ROUTE IS RESTRICTED.AMENT SHEETS A.04, | | A.30 AND LS.2 TO SHOW THIS DOOR AS | | OUTSWING WITH THE HINGES ON THE WEST | | SIDE SUCH THAT THE WIDTH IS NO LONGER | | RESTRICTED BY THE PLANTING. | | | | 48) FBC 11-4.13.4SHEET A.48, DOUBLE | | LEAF DOORWAYS 21, 27 & 31 (MIS-LABELLED | | ON SHEET A.04, A.11 & A.12 AS DOOR #22) | | DO NOT HAVE AT LEAST ONE LEAF WITH A | | CLEAR OPENING OF 32".AMEND THE PLANS. | | | | 49) FBC 11-4.3.2SHEET A.O4.THE | | ACCESSIBLE RAMP TO THE PATH AROUND THE | | LAWN AREA OF THE COURTYARD IS TOO REMOTE | | FROM FITNESS, CONFERENCE ROOM AND CLUB | | ROOM.AMEND THE PLAN. | | | | 50) SHEET A.29PRE-CAST CONCRETE | | ARCHITECTURAL FEATURES/MOLDINGS. PROVIDE | | ATTACHMENT DETAILS FOR THESE ITEMS. | | | | 51) FBC 11-413.8DOOR THRESHOLDS. SHEET | | A.43 - DETAIL L AND SHEET A.44-DETAIL. | | THE THRESHOLDS AT EXTERIOR SLIDING DOORS | | SHALL NOT EXCEED 3/4" IN HEIGHT (SEE | | ALSO FAIR HOUSING ACT DESIGN MANUAL | | PAGE 4.14).AMEND THE PLANS. | | | | 52) FBC 412.5(3)SHEET M4.01,SMOKE | | CONTROL NOTE C.THIS NOTE DOES NOT MAKE | | SENSE.AMEND THE NOTE TO DEMONSTRATE | | COMPLIANCE WITH FBC 412.5(3). | | | | 53) FBC 1005.6.9.9SHEET M4.01, STAIR | | AND ELEVATOR PRESSURIZATION NOTES AND/OR | | SHEET M3.01, CORRIDOR/STAIR RISER | | DIAGRAMS SHALL STATE THE REQUIREMENT FOR | | MIN. 2,500 CFM DISCHARGE THROUGH THE | | RELIEF LOUVERS AND FOR A MAX. 0.35 WATER | | COLUMN COMBINED PRESSURE IN THE STAIR- | | WELLS. ANNOTATE THE PLANS TO DEMONSTRATE | | COMPLIANCE. | | | | 54) TO EXPEDITE REVIEW OF A RESUBMITTAL | | WHICH REQUIRES NEW PLANS IN ORDER TO | | ADDRESS THE ABOVE COMMENTS, THE OLD | | SHEETS SHALL BE REMOVED AND THE NEW | | SHEETS INSERTED.ONE COPY OF EACH OLD | | SHEET SHOULD BE STAPLED/CLIPPED TO THE | | REMAINING OLD SHEETS FOR COMPARISON OF | | REVISIONS WHEN REVIEWING THE RESUBMITTED | | PLANS. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2004-02-11 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-02-11 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-02-11 |
Time |
16:35 |
Sent To |
|
|
Notes |
2004-02-11 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | THE PLANS WERE WITHDRAWN BY APPLICANT | | AFTER FIRE AND PLUMBING PLAN REVIEWS, SO | | NO OTHER REVIEWS CAN BE CARRIED OUT.AS | | REVIEWS (TWO) WERE CARRIED OUT ON THE | | 2ND RE-SUBMITTAL, AFTER THE ORIGINAL | | APPLICATION, IT SHALL STILL BE COUNTED | | AS THE 3RD REVIEW. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-11-21 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2003-11-21 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2003-11-21 |
Time |
14:07 |
Sent To |
|
|
Notes |
2003-11-21 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | ***SEE COMMENT #43*** | | | | NOTE: | | MANY OF THE PREVIOUS BUILDING/STRUCTURAL | | PLAN REVIEW COMMENTS HAVE NOT BEEN | | ADDRESSED. | | CHAPTER 553.80(2)(B) FLORIDA STATUTES | | STATES THAT A LOCAL GOVERNMENT SHALL | | IMPOSE A FEE OF FOUR TIMES THE FEE FOR | | PLAN REVIEW, IF PLANS ARE REJECTED THREE | | OR MORE TIMES FOR REPEATED FAILURE TO | | CORRECT A CODE VIOLATION. | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | ARE NUMBERED AS PER THE BUILDING PLAN | | REVIEW OF 6/19/03: | | | | 1) THE NOTICE OF COMMENCEMENT SHALL BE | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | AND A COPY SUBMITTED TO THIS OFFICE | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | 2) IMPACT FEES. THE PLANS SHALL BE TAKEN | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | STAMPED AT THAT OFFICE AND A COPY OF THE | | PAID RECEIPT SUBMITTED TO THE CITY OF | | WEST PALM BEACH DEPT OF CONSTRUCTION | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | 3) THE PROPOSED BUILDING STRUCTURE | | TRANSGRESSES LEGAL BOUNDARY LINES | | BETWEEN THE LOTS WHICH COMBINE TO FORM | | 'THE SITE'.SUBMIT A COPY OF THE 'UNITY | | OF TITLE' DOCUMENT SO THAT FBC TABLE 600 | | BOUNDARY LINE REQUIREMENTS MAY BE DEEMED | | NOT APPLICABLE. | | | | 4) CONDOMINIUM V APARTMENTS.IF THE | | DWELLING UNITS ARE TO BE SOLD AS | | CONDOMINIUMS, NO CERTIFICATE OF | | OCCUPANCY CAN BE ISSUED UNTIL A | | 'DECLARATION OF CONDOMINIUM' HAS BEEN | | SUBMITTED TO THE STATE FOR APPROVAL, AND | | THEN RECORDED WITH THE CLERK OF THE | | COUNTY COURT.A RECORDED COPY SHALL BE | | SUBMITTED TO THE CITY FOR RECORDS, | | ADDRESSING PURPOSES, AND NOTIFICATION OF | | PALM BEACH COUNTY PROPERTY APPRAISER'S | | OFFICE. | | | | 5) FBC* 104.4.5 SPECIAL FOUNDATION | | PERMIT. THE BUILDING OFFICIAL MAY, AT | | HIS DISCRETION, ISSUE A SPECIAL PERMIT | | FOR THE FOUNDATION ONLY, UPON WRITTEN | | REQUEST BY THE OWNER AND CONTRACTOR. THE | | HOLDER OF SUCH SPECIAL PERMIT IS PROCEED | | ING AT HIS/HER OWN RISK AND WITHOUT | | ASSURANCE THAT A PERMIT FOR THE | | REMAINDER OF THE WORK WILL BE GRANTED | | AND THAT CORRECTIONS WILL NOT BE | | REQUIRED IN ORDER TO MEET THE PROVISIONS | | OF THE TECHNICAL CODES. | | | | 6) FBC* 105.13.1SPECIAL INSPECTOR.A | | STRUCTURAL INSPECTION PLAN MUST BE | | SUBMITTED PRIOR TO THE ISSUANCE OF A | | BUILDING PERMIT FOR THE CONSTRUCTION OF | | A THRESHOLD BUILDING.A THRESHOLD | | BUILDING IS ANY BUILDING WHICH IS | | GREATER THAN THREE STORIES OR 50 FEET IN | | HEIGHT, OR WHICH HAS AN ASSEMBLY | | OCCUPANCY WITH 5,000 SQFT AREA AND | | GREATER THAN 500 OCCUPANTS.THREE | | COPIES OF THE PLANS AND OTHER DOCUMENTS | | WILL BE REQUIRED FOR PERMITTING PURPOSES | | | | 7) A SEPARATE PERMIT APPLICATION WILL BE | | REQUIRED FOR THE SWIMMING POOL. | | | | 8) THIS COMMENT HAS NOT BEEN ADDRESSED. | | FBC* 1804.2.2SHEET S-0, FOUNDATIONS | | SUBMIT COPIES OF GFA INTERNATIONAL SOIL | | REPORT AS REFERENCED IN THE NOTES. | | | | 9) THIS COMMENT HAS NOT BEEN ADDRESSED. | | FBC 13-103.1.1.1 AND 103.1.2SHEET 2 | | OF THE SUBMITTED ENERGY CODE COMPLIANCE | | FORMS SHALL BE SIGNED BY THE OWNER (OR | | THE PROJECT ARCHITECT OR OTHER | | AUTHORIZED AGENT DESIGNATED BY THE | | OWNER) TO CERTIFY COMPLIANCE WITH THE | | CODE.ALSO THE ARCHITECT'S NAME AND | | REGISTRATION NUMBER SHALL BE ADDED ABOVE | | THAT OF THE MEP ENGINEER. | | | | 10) FBC* F102.2.4FIRE DISTRICT.THE | | ROOF COVERING SHALL CONFORM TO CLASS A | | OR B AS DEFINED IN FBC 1505.AMEND THE | | PLANS TO DEMONSTRATE COMPLIANCE. | | | | 11) THIS COMMENT HAS NOT BEEN ADDRESSED. | | SUBMIT PRODUCT APPROVALS FOR THE | | WINDOWS, STOREFRONTS, EXTERIOR DOORS AND | | ROOFING PRODUCTS. | | | | 12) THIS COMMENT HAS NOT BEEN ADDRESSED. | | FBC* 104.2.1.2BUILDING DATA.THE | | BUILDING AREAS, CONSTRUCTION TYPE AND | | OTHER CODE/BUILDING DESIGN CRITERIA | | SHALL BE STATED ON THE PLANS(NOTE: TO | | COMPLY WITH TABLE 500 FOR A SPINKLERED, | | TWO STOREY ENCLOSED PARKING GARAGE | | >60,000 SQ FT, TYPE I CONSTRUCTION IS | | REQUIRED) | | | | 13) FBC 1606.1.7WIND LOAD.THIS | | COMMENT HAS NOT BEEN PROPERLY ADDRESSED. | | IT IS NOTED THAT SHEET S-0 INCLUDES | | INFORMATION UNDER THE TITLE 'WIND LOADS' | | BUT THE WIND IMPORTANCE FACTOR, INTERIOR | | PRESSURE COEFFICIENT, EXTERIOR COMPONENT | | AND CLADDING WIND PRESSURES MUST ALSO BE | | ADDED. | | | | 14) FBC* 104.2.1SHEET A.23.THE NORTH | | ELEVATION DOES NOT SHOW THE FIRST FLOOR | | DOOR #15 (BETWEEN GRIDS T.3 & T.4) TO | | THE VALET.AMEND/CLARIFY. | | | | 17) FBC 705.1.2SHEETS LS.1 TO LS.4. | | THIS COMMENT HAS NOT BEEN PROPERLY | | ADDRESSED.AMEND THE LEGEND TO INDICATE | | THE REQUIRED ONE HOUR FIRE RATING FOR | | THE ELEVATOR LOBBIES AND TWO HOUR RATING | | FOR THE WALL TYPE SHOWN AROUND THE STAIR | | SHAFTS, TRASH CHUTE ETC. | | | | 18) THIS COMMENT HAS NOT BEEN ADDRESSED. | | FBC 412.6SHEET A.02, PARKING LEVEL | | PLAN.AMEND THE PLAN TO CLARIFY THE | | PURPOSED (I.E. IN LIEU OF ELEVATOR | | LOBBY), CONSTRUCTION AND FIRE-RATING OF | | THE WALL/DOOR THAT HAS BEEN PROVIDED IN | | FRONT OF ELEVATORS 1 TO 3. | | | | 20) THIS COMMENT HAS NOT BEEN ADDRESSED. | | FBC 411.2.6SHEETS A.03 & A.48.THE | | PUMP ROOM SHALL BE SEPARATED FROM THE | | PARKING GARAGE BY 1-HOUR FIRE | | RESISTANT CONSTRUCTION.AMEND THE PLANS | | | | 23) THIS COMMENT HAS NOT BEEN ADDRESSED. | | FBC TABLES 704.2.4 & 705.1.2SHEETS | | A.04 & A.48.THE MANAGER'S OFFICE | | SUITE, THE CONFERENCE ROOM, CLUB ROOM, | | PANTRY AND FITNESS CENTER ARE ON THE | | EXIT ACCESS CORRIDOR AND SHALL BE AT | | LEAST 30-MINUTE FIRE-RATED WITH | | 20-MINUTE FIRE-RATED DOORS (DOOR #'S 16, | | 27, 32 AND THE PANTRY DOOR WHICH IS | | INCORRECTLY LABELLED AS DOOR #58). AMEND | | THE PLANS. | | | | 26) FBC 11-4-13.6 SHEET A.12 & 13 GROUND | | LEVEL PLANS, MANEUVERING CLEARANCES AT | | DOORS. THE DOORS TO THE CARD ROOM (024), | | CONFERENCE ROOM (016) AND CONFERENCE | | WAITNG ROOM (016), SHALL HAVE A MINIMUM | | OF 18" CLEARANCE BETWEEN THE STRIKE EDGE | | OF THE DOOR AND THE ADJACENT WALL ON THE | | PULL SIDE OF THE DOOR (REF FIG.25A). | | AMEND THE PLANS.THIS COMMENT ALSO | | APPLIES TO THE RESIDENTIAL UNIT ENTRANCE | | DOORS (FOR EXAMPLE GROUND LEVEL UNITS | | A5, A5 MOD, B2.1, B4 AND B6) | | | | 28) THIS COMMENT HAS NOT BEEN ADDRESSED. | | FBC 1012.1.4SHEET A.36.THE STOREY | | EXIT DOORS INTO STAIR #3 AT EACH LEVEL | | SHALL LEAVE, UNOBSTRUCTED, AT LEAST ONE | | HALF OF THE REQUIRED LANDING WIDTH. | | AMEND THE PLANS. | | | | 29) THIS COMMENT HAS NOT BEEN ADDRESSED. | | FBC 1007.5.5SHEET A.34, STAIR #1 PLANS | | THE HANDRAILS SHALL EXTEND AT LEAST 12" | | HORIZONTALLY BEYOND THE TOP RISER OF | | EACH FLIGHT.THE STAIR #1 PLANS SHOW | | ONLY 11".AMEND THE PLANS. | | | | 30) FBC 1015.4GUARDRAIL STRENGTH.THE | | PLANS SHALL BE AMENDED TO STATE THE | | STRENGTH REQUIREMENTS SET OUT IN | | FBC 1608.2 | | | | 33) THIS COMMENT HAS NOT BEEN ADDRESSED. | | FBC *104.2.1SHEET A.44, DETAIL M, | | SLIDING GLASS DOOR THRESHOLD.THE | | DETAIL SHALL MAKE REFERENCE TO 'THE DOOR | | PRODUCT APPROVAL' FOR ANCHOR | | SPECIFICATION.AMEND THE DETAIL. | | | | 34) THIS COMMENT HAS NOT BEEN ADDRESSED. | | FBC 411.2.3AUTOMOBILE PARKING GARAGE, | | GUARDING.THE INTERIOR PARKING GARAGE | | WALLS ADJACENT THE VEHICLE RAMP, STAIR 2 | | AND 4, AND THE FRONT WALL OF THE | | ELEVATOR SHAFTS (SEE SHEET S-3) SHALL BE | | DESIGNED TO WITHSTAND IMPACT LOADING IN | | ACCORDANCE WITH FBC 1608.2.3.PROVIDE | | STRUCTURAL DETAILS OF THE WALLS AT THESE | | LOCATIONS. | | | | 35) FBC 2405.2THE SHOWER ENCLOSURE | | GLAZING IS IN A 'HAZARDOUS LOCATION' AND | | REQUIRED TO BE SAFETY GLASS SATISFYING | | THE REQUIREMENTS OF THE CONSUMER PRODUCT | | SAFETY COMMISSION 16, CODE OF FEDERAL | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | PART 1201).AMEND THE PLANS TO | | DEMONSTRATE COMPLIANCE. | | | | 39) THIS COMMENT HAS NOT BEEN ADDRESSED. | | FBC 11-4.15.2SHEET A.67,DRINKING | | FOUNTAIN SPOUT HEIGHT AND KNEE CLEARANCE | | THE HEIGHT FROM FINISHED FLOOR TO THE | | SPOUT (NOT THE TOP OF THE FOUNTAIN TRAY) | | SHALL BE 36" (REF: FIG. 27A).THE | | DIMENSIONS ARE SHOWN INCORRECTLY ON ONE | | OF THE TWO DETAILS.AMEND THE PLANS. | | | | 41) FBC 1010.1SHEET LS.2WHAT IS THE | | ROUTE TO EXIT DISCHARGE FROM STAIR #4? | | AMEND THE PLANS TO CLARIFY. | | | | 42) SHEET S-17, UPPER LEVEL ROOF PLAN | | MAKES A NUMBER OF REFERENCES TO HUGHES | | ANCHORS.THAT COMPANY NO LONGER | | SUPPLIES ANCHORS.AMEND THE PLANS TO | | SPECIFY VALID ANCHORS AND STATE THE | | NUMBER AND SIZE FASTENERS. | | | | 43) MANY OF THE COMMENTS FROM THE | | PREVIOUS REVIEW HAVE NOT BEEN ADDRESSED. | | A FULL REVIEW HAS NOT BEEN CARRIED OUT | | BECAUSE NO COMMENT RESPONSE LETTERS, OLD | | PLANS OR REVISION CLOUDS/MARKERS WERE | | INCLUDED WITH THE RE-SUBMITTAL.TO | | EXPEDITE THE REVIEW, THE RE-SUBMITTAL | | SHALL INCLUDE AT LEAST ONE OF THE ABOVE | | MEANS OF DESCRIBING THE REVISIONS MADE. | | | | 44) IF NEW PLAN SHEETS ARE REQUIRED, IN | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | SHEETS INSERTED.ONE COPY OF EACH OLD | | SHEET SHALL BE INCLUDED WITH THE | | RESUBMITTAL FOR COMPARISON OF REVISIONS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-06-20 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2003-06-19 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2003-06-19 |
Time |
13:49 |
Sent To |
|
|
Notes |
2003-06-19 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | 1) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, THE PLANS STAMPED BY THEM | | AND A COPY OF THE RECEIPT SUBMITTED TO | | THE CITY OF WEST PALM BEACH CONSTRUCTION | | SERVICES DEPARTMENT BEFORE A BUILDING | | PERMIT CAN BE ISSUED. | | | | 3) THE BUILDING STRUCTURE TRANSGRESSES | | LEGAL BOUNDARY LINES BETWEEN THE LOTS | | WHICH COMBINE TO FORM 'THE SITE'. SUBMIT | | A COPY OF THE UNITIVE TITLE DOCUMENT SO | | THAT FBC TABLE 600 BOUNDARY LINE | | REQUIREMENTS MAY BE DEEMED NOT | | APPLICABLE. | | | | 4) CONDOMINIUM V APARTMENTS.IF THE | | DWELLING UNITS ARE TO BE SOLD AS | | CONDOMINIUMS, NO CERTIFICATE OF | | OCCUPANCY CAN BE ISSUED UNTIL A | | 'DECLARATION OF CONDOMINIUM' HAS BEEN | | SUBMITTED TO THE STATE FOR APPROVAL, AND | | THEN RECORDED WITH THE CLERK OF THE | | COUNTY COURT.A RECORDED COPY SHALL BE | | SUBMITTED TO THE CITY FOR RECORDS, | | ADDRESSING PURPOSES, AND NOTIFICATION OF | | PALM BEACH COUNTY PROPERTY APPRAISER'S | | OFFICE. | | | | 5) FBC* 104.4.5 SPECIAL FOUNDATION | | PERMIT. THE BUILDING OFFICIAL MAY, AT | | HIS DISCRETION, ISSUE A SPECIAL PERMIT | | FOR THE FOUNDATION ONLY, UPON WRITTEN | | REQUEST BY THE OWNER AND CONTRACTOR. THE | | HOLDER OF SUCH SPECIAL PERMIT IS PROCEED | | ING AT HIS/HER OWN RISK AND WITHOUT | | ASSURANCE THAT A PERMIT FOR THE | | REMAINDER OF THE WORK WILL BE GRANTED | | AND THAT CORRECTIONS WILL NOT BE | | REQUIRED IN ORDER TO MEET THE PROVISIONS | | OF THE TECHNICAL CODES. | | | | 6) FBC* 105.13.1SPECIAL INSPECTOR.A | | STRUCTURAL INSPECTION PLAN MUST BE | | SUBMITTED PRIOR TO THE ISSUANCE OF A | | BUILDING PERMIT FOR THE CONSTRUCTION OF | | A THRESHOLD BUILDING.A THRESHOLD | | BUILDING IS ANY BUILDING WHICH IS | | GREATER THAN THREE STORIES OR 50 FEET IN | | HEIGHT, OR WHICH HAS AN ASSEMBLY | | OCCUPANCY WITH 5,000 SQFT AREA AND | | GREATER THAN 500 OCCUPANTS.THREE | | COPIES OF THE PLANS AND OTHER DOCUMENTS | | WILL BE REQUIRED FOR PERMITTING. | | | | 7) A SEPARATE PERMIT APPLICATION WILL BE | | REQUIRED FOR THE SWIMMING POOL. | | | | 8) FBC* 1804.2.2SHEET S-0, FOUNDATIONS | | SUBMIT COPIES OF GFA INTERNATIONAL SOIL | | REPORT AS REFERENCED IN THE NOTES. | | | | 9) FBC 13-103.1.1.1 AND 103.1.2SHEET 2 | | OF THE SUBMITTED ENERGY CODE COMPLIANCE | | FORMS SHALL BE SIGNED BY THE OWNER (OR | | THE PROJECT ARCHITECT, OR OTHER | | AUTHORIZED AGENT DESIGNATED BY THE | | OWNER) TO CERTIFY COMPLIANCE WITH THE | | CODE.ALSO THE ARCHITECT'S NAME AND | | REGISTRATIONNUMBER SHALL BE ADDED | | ABOVE THAT OF THE MEP ENGINEER. | | | | 10) FBC* F102.2.4FIRE DISTRICT.THE | | ROOF COVERING SHALL CONFORM TO CLASS A | | AND B AS DEFINED IN FBC 1505.AMEND THE | | PLANS TO DEMONSTRATE COMPLIANCE. | | | | 11) SUBMIT PRODUCT APPROVALS FOR THE | | WINDOWS, STOREFRONTS, EXTERIOR DOORS AND | | ROOFING PRODUCTS. | | | | 12) FBC* 104.2.1.2BUILDING DATA.THE | | BUILDING AREAS, CONSTRUCTION TYPE AND | | OTHER CODE/BUILDING DESIGN CRITERIA | | SHALL BE STATED ON THE PLANS.(NOTE: TO | | COMPLY WITH TABLE 500 FOR A SPRINKLERED, | | TWO STOREY, ENCLOSED PARKING GARAGE | | >60,000 SQ FT, TYPE I CONSTRUCTION IS | | REQUIRED) | | | | 13) FBC 1606.1.7WIND LOAD.THE PLANS | | SHALL STATE THE BASIC WIND SPEED, WIND | | IMPORTANCE FACTOR, WIND EXPOSURE | | CATEGORY, INTERNAL PRESSURE COEFFICIENT, | | AND EXTERIOR COMPONENT AND CLADDING | | DESIGN WIND PRESSURES. | | | | 14) FBC* 104.2.1SHEETS A.22 & A.23. | | THE SOUTH AND NORTH ELEVATIONS DO NOT | | APPEAR TO REPRESENT FENESTRATION AND | | OTHER ARCHITECTURAL FEATURES SHOWN ON | | THE PLANS.FOR EXAMPLE, THE NUMBER OF | | WINDOWS ON THE ELEVATIONS IS DIFFERENT | | TO THE PLANS.PLEASE AMEND/CLARIFY. | | | | 15) FBC* 104.2.1SHEET A.02PARKING | | LEVELS B-1 & B-2. STAIR 4 IS INCORRECTLY | | LABELLED AS 'STAIR 2'.AMEND THE PLAN. | | | | 16) FBC* 104.2.1SHEET A.35.THE STAIR | | 2 PLANS ARE MIS-LABELLED AS 'STAIR 3'. | | | | 17) FBC 705.1.2SHEETS LS.1 TO LS.4 | | AMEND THE LEGEND TO INDICATE THE | | REQUIRED ONE HOUR RATING FOR THE | | ELEVATOR LOBBIES AND TWO HOUR RATING FOR | | THE WALL TYPE SHOWN AROUND THE STAIR | | SHAFTS, TRASH CHUTE ETC. | | | | 18) FBC 412.6SHEET A.02, PARKING LEVEL | | PLAN.AMEND THE PLAN TO CLARIFY THE | | THE PURPOSE, CONSTRUCTION AND | | FIRE-RATING OF THE WALL/DOOR THAT HAS | | BEEN PROVIDED, IN FRONT OF ELEVATORS | | 1 TO 3, IN LIEU OF ELEVATOR LOBBIES. | | | | 19) FBC 411.4.2SHEET A.02, ENCLOSED | | PARKING GARAGES, MECHANICAL VENTILATION | | AND SMOKE EVACUATION.THE REFERENCE TO | | 'STACKED FANS' IS NOTED.ANNOTATE THE | | PLANS TO CLARIFY THE PROVISION OF | | DEDICATED MECHANICAL VENTILATION AT EACH | | LEVEL OF THE PARKING GARAGE. | | | | 20) FBC 411.2.6SHEETS A.02 & A.48THE | | PUMP ROOM SHALL BE SEPARATED FROM THE | | PARKING GARAGE BY 1-HOUR FIRE RESISTANT | | CONSTRUCTION. | | | | 21) FBC 1012.1.2SHEET A.04, GROUND | | LEVEL PLAN.THE STAIR #2 DOOR SHALL | | OPEN IN THE DIRECTION OF EGRESS.AMEND | | THE PLAN. | | | | 22) FBC 1010.3SHEET A.04, GROUND LEVEL | | PLAN, MAIN LOBBY.THE EXIT DISCHARGE | | FROM STAIR #2 IS THROUGH THE MAIN LOBBY | | WHICH MUST THEREFOR SATISFY THE | | REQUIREMENTS OF THE EXCEPTION UNDER | | FBC 1010.3.RECOMMENDATION: PROVIDE TWO | | 1-1/2 HOUR CROSS-CORRIDOR DOORS, ONE | | BETWEEN THE STUDIO 'S2' KITCHEN WALL AND | | THE UNIT 'C1' POWDER ROOM WALL OPPOSITE | | AND ONE BETWEEN THE RECEPTION | | ADMINISTRATION AREA AND ELEVATOR #2. | | THIS WOULD LIMIT THE SIZE OF THE EXIT | | DISCHARGE AREA AND SO LIMIT THE | | POTENTIAL RISK OF FIRE/SMOKE INGRESS | | INTO THE EXIT DISCHARGE. | | | | 23) FBC TABLES 704.2.4 & 705.1.2SHEETS | | A.04 & A.48. THE RECEPTION ADMINISTRAT'N | | OFFICE, CONFERENCE RM, BUSINESS CENTER, | | FIRE COMMAND CENTER, CLUB ROOM AND | | HEALTH CLUB ARE IN THE EXIT ACCESS | | CORRIDOR AND SHALL BE AT LEAST 30-MINUTE | | FIRE-RATED WITH 20-MINUTE FIRE-RATED | | DOORS (DOOR #'S 16, 17, 18, 20, 26 & 27) | | | | 24) SHEET A.04 & A.48THE CA/TV ROOM | | DOOR IS SHOWN AS DOOR REF #30.SHOULD | | THIS BE #38 (SEE DOOR SCHEDULE)? | | | | 25) FBC TABLE 704.1SHEET A.13 & A.14 | | GROUND LEVEL (PARTIAL) PLAN.THE WALL | | BETWEEN THE CONFERENCE ROOM AND | | UNIT 'A6' IS SHOWN AS TYPE 13, WHICH IS | | NOT A FIRE-RATED WALL TYPE.AMEND THE | | PLAN TO SHOW A MINIMUM OF 1-HOUR FIRE- | | RATING FOR THIS WALL. | | | | 26) FBC 11-4.13.6SHEET A.11, GROUND | | LEVEL PLANS, MANEUVERING CLEARANCES AT | | DOORS.THE MEN'S AND WOMEN'S TOILET | | ROOM DOORS FROM CORRIDOR 027 SHALL HAVE | | A MINIMUM OF 18" CLEARANCE BETWEEN THE | | LEADING EDGE OF THE DOOR AND THE | | ADJACENT PERPENDICULAR WALL ON THE PULL | | SIDE OF THE DOOR.AMEND THE PLANS | | | | 27) FBC 11-4.13.6 MANEUVERING CLEARANCES | | AT DOORS.THE CONFERENCE ROOM LOBBY, | | BUSINESS CENTER, CLUB ROOM AND HEALTH | | CLUB ENTRANCE DOORS FROM CORRIDOR 027 | | (SHEET A.13, GROUND LEVEL) SHALL HAVE A | | MINIMUM 12" CLEARANCE BETWEEN THE | | LEADING EDGE OF THE DOOR AND THE | | ADJACENT RECESSED WALL ON THE PUSH SIDE | | OF THE DOOR IF IT HAS BOTH A CLOSER AND | | A LATCH.AMEND THE PLANS.THIS COMMENT | | ALSO APPLIES TO ALL RESIDENTIAL UNIT | | RECESSED ENTRANCE DOORS (FOR EXAMPLE | | GROUND FLOOR UNITS 'A2' AND 'A4'), IF | | THEY HAVE BOTH A CLOSER AND A LATCH. | | | | 28) FBC 1012.1.4SHEET A.36THE STOREY | | EXIT DOORS INTO STAIR #3 AT EACH LEVEL | | SHALL LEAVE UNOBSTRUCTED AT LEAST ONE | | HALF OF THE REQUIRED WIDTH OF THE | | LANDING.AMEND THE PLAN. | | | | 29) FBC 1007.5.5SHEET A.34, STAIR #1 | | PLANS.THE HANDRAILS SHALL EXTEND AT | | LEAST 12" HORIZONTALLY BEYOND THE TOP | | RISER OF EACH FLIGHT.THE STAIR #1 | | PLANS SHOW ONLY 11", AMEND THE PLANS. | | | | 30) FBC 1015.4GUARDRAIL STRENGTH.THE | | PLANS SHALL BE AMENDED TO STATE THE | | STRENGTH REQUIREMENTS SET OUT IN | | FBC 1608.2. | | | | 31) FBC 1015.3SHEET A.34, A.35 & A.36 | | THE PLANS SHALL STATE THE REQUIREMENT | | FOR THE BOTTOM RAIL OF THE GUARDING TO | | BE POSITIONED SUCH THAT A 6" DIAMETER | | SPHERE CANNOT PASS THROUGH THE | | TRIANGULAR OPENING THAT IT FORMS WITH | | THE TREAD AND THE RISER. | | | | 32) FBC 1015.3SHEET A.44, DETAIL J. | | THE GUARDRAIL DETAIL SHALL MAKE | | REFERENCE TO THE REQUIREMENTS FOR THE | | SPACING BETWEEN PICKETS TO REJECT THE | | PASSAGE OF A 4" DIAMETER SPHERE, AND FOR | | THE BOTTOM RAIL POSITIONING TO REJECT | | THE PASSAGE OF A 2" DIAMETER SPHERE. | | | | 33) FBC* 104.2.1SHEET A.44, DETAIL M, | | SLIDING GLASS DOOR THRESHOLD. THE DETAIL | | SHALL MAKE REFERENCE TO A PRODUCT | | APPROVAL FOR ANCHOR SPECIFICATION. | | | | 34) FBC 411.2.3AUTOMOBILE PARKING | | GARAGE, GUARDING.THE INTERIOR PARKING | | GARAGE WALLS ADJACENT THE VEHICLE RAMP, | | STAIR 2 AND 4, AND THE FRONT WALL OF THE | | ELEVATOR SHAFTS SHALL BE DESIGNED TO | | WITHSTAND IMPACT LOADING IN ACCORDANCE | | WITH FBC 1608.2.3.PROVIDE STRUCTURAL | | DETAILS OF THE WALLS AT THESE LOCATIONS. | | | | 35) FBC 2405.2THE SHOWER ENCLOSURE | | GLAZING IS IN A 'HAZARDOUS LOCATION' AND | | REQUIRED TO BE SAFETY GLASS SATISFYING | | THE REQUIREMENTS OF THE CONSUMER PRODUCT | | SAFETY COMMISSION 16, CODE OF FEDERAL | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | PART 1201).AMEND THE PLANS TO | | DEMONSTRATE COMPLIANCE. | | | | 36) FBC* 104.2.1THE SUBMITTED | | STRUCTURAL PLANS DO NOT PROVIDE A | | COMPLETE DESCRIPTION OF THE STRUCTURE. | | SUBMIT FURTHER STRUCTURAL DETAILS. | | | | 37) FBC 11-4.16.4SHEET A.67, GRAB BARS | | AT WATER CLOSETS.THE SIDE GRAB BAR | | SHALL BE A MINIMUM OF 3'6" LONG SUCH | | THAT IT EXTENDS TO NO LESS THAN 54" FROM | | THE REAR WALL (REF: FIGURE 29(B)).THE | | DIMENSIONS ARE SHOWN INCORRECTLY ON ONE | | OF THE TWO DETAILS.AMEND THE PLANS. | | | | 38) FBC 11-4.16.2SHEET A.67, CLEAR | | FLOOR SPACE AT WATER CLOSETS.THE | | LAVATORY SHALL BE AT LEAST 18" FROM THE | | CENTER-LINE OF THE W.C. AND 36" FROM THE | | SIDE WALL (REF: FIGURE 28).AMEND THE | | PLANS. | | | | 39) FBC 11-4.15.2SHEET A.67, SPOUT | | HEIGHT AND KNEE CLEARANCE.THE HEIGHT | | FROM FINISHED FLOOR TO THE SPOUT (NOT | | THE TOP OF THE FOUNTAIN TRAY) SHALL BE A | | MAXIMUM OF 36" (REF: FIGURE 27(A)).THE | | DIMENSIONS ARE SHOWN INCORRECTLY ON ONE | | OF THE TWO DETAILS.AMEND THE PLANS. | | | | 40) IF NEW PLAN SHEETS ARE REQUIRED, IN | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | SHEETS INSERTED.ONE COPY OF EACH OLD | | SHEET SHALL BE INCLUDED WITH THE | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
19 |
Status |
P |
Date |
2006-10-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-10-05 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-10-05 |
Time |
08:02 |
Sent To |
PC |
|
Notes |
2006-10-05 00:00:00 | ARDDRESS COMMENTS FROM REV'S FROM THE | | PREVIOUS YEAR. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
18 |
Status |
N |
Date |
2006-08-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-08-05 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-05 |
Time |
15:06 |
Sent To |
FIRE |
|
Notes |
2006-08-05 00:00:00 | REVISED FIRE ALARM DEVICES. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
17 |
Status |
F |
Date |
2006-07-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-05 |
Time |
20:40 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-05 |
Time |
20:14 |
Sent To |
|
|
Notes |
2006-07-05 00:00:00 | ******** UNSAT ********* | | | | 1) NOTE: PLEASE SEE ALL REVIEWS I AM | | ATTACHING TO THESE REVIEWS NOTES. | | PLEASE SEE AT LEAST 7 SETS OF REVISIONS | | DATING BACK TO 7/12/05 WHICH HAVE NOT | | BEEN ADDRESSED TO DATE. THIS SEVEN | | REVIEWS ARE STILL BEING SHOWN IN A | | "FALIED" STATUS. | | PLEASE SEE SOME REVISIONS WERE | | SUBMITTED AND PASSED (THREE DATING | | 1/4/06,1/5/06, AND 5/17/06). PLEASE SEE | | THAT THESE REVIEWS FOR REVISIONS WHICH | | WERE PLACED INTO A "P" STATUS WERE FOR | | OTHER SHEETS AND NOT FOR THE | | PLANS/REVISIONS WHICH HAD PREVIOUS | | COMMENTS. | | | | ** PLEASE KNOW THAT NO FURTHER | | ELECTRICAL REVISIONS WILL BE REVIEWED | | UNTIL COMPLETE REVISIONS ARE SUBMITTED | | ADDRESSING ALL COMMENTS. | | | | ** PLEASE KNOW A PERMANANT CERTIFICATE | | OF OCCUPANCY WILL NOT BE GRANTED UNTIL | | ALL REVISIONS ARE ADDRESSED 100%. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
16 |
Status |
P |
Date |
2006-06-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-02 |
Time |
07:36 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-02 |
Time |
07:25 |
Sent To |
|
|
Notes |
2006-06-02 00:00:00 | REV FOR SHEET 4.01 ONLY. | | REVISED PLANS FOR OTHER ELECTRICAL | | COMMENTS FROM PREVIOUS REVIEW WERE NOT | | SUBMITTED AS OF THIS REVIEW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
15 |
Status |
F |
Date |
2006-05-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-05-17 |
Time |
22:35 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-05-17 |
Time |
22:26 |
Sent To |
|
|
Notes |
2006-05-17 00:00:00 | ** UNSAT** | | | | 1) NOTE: PLEASE SEE SHEETS 2.01-2.05, | | MANY OF THE RECEPTS FOR LV PLUG IN | | TRANSFORMERS ARE STILL BEING SHOWN ABOVE | | COMBUSTIBLES AND SHELVING AREAS. THIS | | WAS NOTED ON PREVIOUS REVIEWS DATING | | BACK TO INTO "05".PLEASE CLARIFY | | UNITS, AND WHERE THESE PLUG IN | | TRANSFORMER ARE INSTALLED. | | | | PLEASE REVISE AND SUBMIT. | | | | IF THERE ARE ANY QUESTIONS, OR IF THIS | | CNA BE GONE OVER ON THE PHONE, PLEASE | | CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
14 |
Status |
P |
Date |
2006-05-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-05-17 |
Time |
22:26 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-05-17 |
Time |
22:02 |
Sent To |
|
|
Notes |
2006-05-17 00:00:00 | REV'S IN ELEC FOR REVIEW. | | SHEETS STAMPED, | | | | 101,102,103,104,110,111,112,206,301, | | 401 AND 402. | | | | PLANS UNSAT ENTERED IN NEXT REVIEW WERE | | SHEETS 201-205 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
13 |
Status |
P |
Date |
2006-01-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-01-05 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-01-05 |
Time |
14:20 |
Sent To |
FIRE |
|
Notes |
2006-01-05 00:00:00 | REV'S FOR COMMON AREA HALLS, SHEETS | | 1.05-1.10 ONLY. | | COMMENTS FOR UNITS STILL NEED TO BE | | ADDRESSED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
12 |
Status |
P |
Date |
2006-01-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-01-04 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-01-04 |
Time |
13:10 |
Sent To |
|
|
Notes |
2006-01-04 00:00:00 | REV FOR 1.04,1.11,AND 4.02 ONLY. | | NO RESIDENTIAL UNITS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
11 |
Status |
F |
Date |
2005-12-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-12-24 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-12-24 |
Time |
13:28 |
Sent To |
|
|
Notes |
2005-12-24 00:00:00 | ********** UNSAT ********** | | | | ** PLEASE SEE REVISONS FOR SOME UNITS | | WHICH WERE STAMPED ON 10/9/05 HAVE SINCE | | BEEN VOIDED. | | | | ** PLEASE SEE NOTE # 3 FROM SECOND | | REVIEW ON 10/9/05 HAS BEEN RECENDED. | | DOOR LOCATED TO SEPARATE BATHRM FROM | | BEDRM FOR UNITS3 | | | | ** PLEASE SEE THE FOLLOWING NOTES, | | PLEASE CORRELATE ALL UNITS AND SUBMIT | | REVISIONS FOR ALL UNITS. | | | | | | 1)NOTE: PLEASE SEE 210.52C1, C3, C4 FOR | | KITCHEN GFI RECEPT SPACING. PLEASE SEE | | SOME UNITS CONTAIN ADDED RECEPTS FOR | | AREA OF 12' OR MORE WALL SPACE AND | | PENINSULAR, HOWEVER SOME UNITS DO NOT | | SHOW THESE. | | PLEASE SEE ONLY ONE UNIT INDICATES A | | NOTE WITH RESPECT TO 12" OR MORE OF | | SPACE REQUIRING THE ADDITIONAL GFI. | | PLEASE SEE SOME UNITS SEEM TO CLEARLY | | INDICATE 12" OR MORE. | | | | 2)NOTE: PLEASE SEE WALL RECEPT MISSING | | IN B1C1 KIT WALL. | | 210.52 | | | | 3)NOTE: PLEASE SEE MANY UNITS HAVE BEEN | | REVISED TO LOCATE THE RECEPT FOR THE LV | | CONTROL PANEL ABOVE DOOR AND PLANS | | INCLUDE A NOTE FOR THIS ALSO, HOWEVER | | PLEASE SEE SOME UNITS WERE NOT CHANGED, | | PLEASE SEE MOST ALL UNITS STILL INDICATE | | A RECEPT IN PANEL AND SOME UNITS EVEN | | MOVED THE RECEPT ABOVE DOOR IN | | LAUNDRY/UTILITY RM? PLEASE KNOW, IF | | THESE PANELS ARE IN THE UTILITY ROOM | | THIS MOVING OF RECEPT ABOVE DOOR IS NOT | | REQUIRED. | | PLEASE ALSO CLARIFY WHY THERE IS A NOTE | | WHICH MENTIONS FOR GROUND FLR UNITS | | ONLY?? | | THIS WOULD BE REQUIRED IN ALL UNITS. | | | | 110.26.240.24 ETC | | | | PLEASE CALL TO GO OVER COMMENTS. | | WIRING TO UNITS SHOULD BE LIMITED UNTIL | | PLANS ARE CORRECTED AND CLEARED. | | | | A NOTICE WILL BE SENT TO THE CHEIF | | ELECTRICAL INSPECTOR AND ELECTRICAL | | INSPECTOR TO NOTIFY OF CORRECTIONS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
10 |
Status |
F |
Date |
2005-10-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-10-09 |
Time |
12:44 |
Rev Time |
0.70 |
Received By |
dpalmer |
Date |
2005-10-09 |
Time |
12:36 |
Sent To |
|
|
Notes |
2005-10-09 00:00:00 | ************* UNSAT *********** | | | | ** PLEASE ALSO SEE REVIEW DATED 10/9/05 | | WHICH SHEETS 2.01,2.02,2.03 AND 2.04 | | HAVE BEEN VOIDED. | | THE FOLLOWING NOTES ARE FOR SHEETS 1.10, | | 1.11,1.12,2.05,4.02 | | | | | | 1)NOTE: PLEASE VERIFY CIRCUITING FOR | | ELEVATOR EQUIPMENT RMS FOR RECEPTS AND | | LTS. | | 620.23 | | PLEASE SEE 1.10, | | PLEASE ALSO INDICATE FIXTURE TYPE BEING | | BATTERY BACK UP OR PLEASE ADD BATTERY | | BACK UP FIXTURE. | | | | 2)NOTE: PLEASE VERIFY FIXTURE TYPE SHOWN | | FOR STAIRWAYS. PLEASE SEE ORIGINAL | | FIXTURE SHCEDULE ON FILE DOES NOT | | CORRELATE WITH FIX TYPE "H">? | | PLEASE ALSO VERIFY IF EVERY OTHER ONE IS | | BATTERY BACK UP. | | PLEASE KNOW THIS WAS NOT A COMMENT ON | | ORIGINAL REVIEWS, HOWEVER FIRE MARSHALS | | OFFICE AND AHJ HAS DETERMIND A BATTERY | | BACK UP FIXTURE WILL BE REQUIRED TO | | MEET MIN FT CANDLES UNDER EMERGENCY | | EXITING. 7.9.2.2, NFPA-101 2000 | | | | | | | | 4)NOTE: PLEASE VEIFY LANSCAPE LIGHTING | | FIXTURE LOCATIONS. | | 120V TO BE A MIN OF 5' FROM WATERS EDGE. | | (GFI PROTECTED) | | LV LTS, MUST BE A MIN OF 10' FROM WATERS | | EDGE. 411.4 | | | | | | PLEASE SEE REDLINED PANELS ON 2.02, | | UNITS "B-6 AND B-4 | | 110.26, 30" MIN WIDTH. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE NAY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
9 |
Status |
F |
Date |
2005-12-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-10-09 |
Time |
12:36 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2005-10-08 |
Time |
18:29 |
Sent To |
|
|
Notes |
2005-10-09 00:00:00 | ELECTRICAL REVISIONS , FOR SHEETS | | 201,202,203, AND 204 ONLY. | | VOIDED ALL SHEETS PREVIOUSLY STAMPED | | *************************************** | | PLEASE SEE REVIEW ALSO DATED 10/9/05 FOR | | NOTES ON SHEETS | | 1.10,1.11,1.12,2.05,4.02. | | ************************************** | 2005-10-08 00:00:00 | REV'S IN ELECTRICAL FOR REVIEW. | | NOTES TO FOLLOW ON SOME SHEETS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
8 |
Status |
F |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-08-09 |
Time |
18:23 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2005-08-09 |
Time |
18:23 |
Sent To |
|
|
Notes |
2005-08-09 00:00:00 | ********* UNSAT ********* | | | | REV'S FOR SHEETS E 2.01,2.03,2.04 | | | | 1)NOTE: PLEASE SEE SOME UNITS, SD'S | | SHALL BE INSTALLED WITHIN 3' OF THE PEAK | | OF A CEILING. PLEASE SEE AREAS IN UNITS | | WHERE SD'S ARE SHOWN ON "LOWERED" | | CEILING AREAS. | | NFPA-72 8-1.4 | | | | 2)NOTE: PLEASE SEE LT FIXTURES SHOWN | | ABOVE MASTER BATH/ BATH TUBS DOES NOT | | INDICATE ANY CIRCUITING, CONTROL ETC.? | | 215.5 | | | | 3)NOTE: PLEASE SEE 210.52C1 FOR KITCHEN | | COUNTERSPACE MIN RECEPT SPACING. | | UNIT B-2,A-1 MOD, PLEASE SEE ANY OTHER. | | 210.52C1-C5 | | | | 4)NOTE: PLEASE ADJUST "DINING/LIVING" | | RM/AREAS SHOWN ON MOST OF THE "A" UNITS. | | PLEASE SEE LIVING RM IS SHOWN WHERE | | DINING RM CIRCUITS ARE SHOWN AND DINING | | RM WHERE LIVING RM IS SHOWN. | | 215.5 | | | | ***PLEASE SEE THAT WHEN PLANS ARE | | SUBMITTED, PLEASE SUBMIT THREE COMPLETE | | SETS WITH ALL SHEETS INSERTED INTO SETS | | IN ORDER. A AND E SHEETS WERE PLACED IN | | ORDER AND INTO THREE SETS BY THIS OFFICE | | ON THIS SUBMITTAL. PLEASE BE SURE ALL | | FUTURE PLANS ARE DONE IN ORDER TO | | EXPEDITE THE PLAN REVIEW PROCESS AND | | AVOID ANY POSSIBLE DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REIVEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
F |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-08-09 |
Time |
17:38 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2005-08-09 |
Time |
17:21 |
Sent To |
|
|
Notes |
2005-08-09 00:00:00 | ** UNSAT ** | | | | REV TO SHEET E1.11 AND LANSCAPE PLANS. | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | REVIEW. | | | | 1)NOTE: PLEASE PROVIDE ROOM DESIGNATIONS | | ON ROOF TOP PLANS. PLEASE SEE | | RESUBMITTED PLANS STILL DO NOT INDICATE | | ALL ROOMS? | | PLEASE SEE CIRCUITING AND LOCATIONS OF | | EQUIPMENT TO BE VERIFIED. | | PLEASE SEE THE FOLLOWING COMMENT.215.5 | | | | 2)NOTE: PLEASE SEE 620.23,620.24 FOR | | REQUIRED DEDICATED BRANCH CIRCUITS FOR | | EACH OF THE ELEVATOR MACHINE ROOMS. | | THESE CIRCUITS MAY NOT BE SHARED WITH | | OTHER AREAS AS SHOWN. | | | | 3)NOTE: PLEASE SEE680.22B, NO LIGHTING | | FIXTURES ARE PERMITTED WITHIN THE 5' | | EXTENDING OUTWARD FROM POOL'S WATER | | EDGE. PLEASE SEE LANDSCAPE PLANS ALSO. | | PLEASE ALSO SEE NO LOW VOLTAGE TYPE | | LIGHT FIXTURES ARE PERMITTED WITHIN 10' | | OF WATERS EDGE. THIS IS DUE TO NO | | EQUIPMENT GROUNDING IN LV TYPE FIXTURES | | AND LV SIDE OF TRANSFORMERS. | | 411.4 | | PLEASE SEE LANSCAPE LIGHTING FIXTURES. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-07-12 |
Time |
17:40 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2005-07-12 |
Time |
17:18 |
Sent To |
|
|
Notes |
2005-07-12 00:00:00 | ******** UNSAT ********* | | | | 1)NOTE: PLEASE SEE MIN ALTERNATING | | CIRCUITS REQUIRED IN EGRESS HALLWAYS, OR | | AN ALTERNATE METHOD TO INSTALL A BATTERY | | BACK UP FIXTURE IN ALTERNATING | | LOCATIONS. | | PLEASE SEE LS 101 7-9, ALTERNATING THE | | HALLS EGRESS CIRCUITS WILL HELP | | ALLEAVIATE LEAVING ANY ONE AREA IN TOTAL | | DARKNESS UPON THE TRIPPING OF ONE | | BREAKER ETC. | | PLEASE ALSO SEE SPEACIAL USEAGE RMS, | | ELEC, FIRE PUMP, FIRE COMMAND RM ETC. | | GEN RM ALREADY SHOWS BATT BACK UP | | FIXTURES ON EM CIRCUIT. | | PLEASE SEE STAIR TOWERS ARE ALREADY | | SHOWN WITH ALTERNATING EM CIRCUITS. | | 700.16 ALSO. | | | | 2)NOTE: PLEASE PROVIDE ROOM DESIGNATIONS | | ON ROOF TOP PLANS. | | PLEASE SEE THE FOLLOWING COMMENT. | | | | 3)NOTE: PLEASE SEE 620.23,620.24 FOR | | REQUIRED DEDICATED BRANCH CIRCUITS FOR | | EACH OF THE ELEVATOR MACHINE ROOMS. | | THESE CIRCUITS MAY NOT BE SHARED WITH | | OTHER AREAS AS SHOWN. | | | | 4)NOTE: PLEASE SEE680.22B, NO LIGHTING | | FIXTURES ARE PERMITTED WITHIN THE 5' | | EXTENDING OUTWARD FROM POOL'S WATER | | EDGE. | | PLEASE SEE LANSCAPE LIGHTING FIXTURES. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2005-05-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-05-04 |
Time |
13:25 |
Rev Time |
4.00 |
Received By |
dpalmer |
Date |
2005-05-04 |
Time |
09:56 |
Sent To |
|
|
Notes |
2005-05-04 00:00:00 | REV'S AS LISTED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-06-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-06-15 |
Time |
17:01 |
Rev Time |
2.00 |
Received By |
dpalmer |
Date |
2004-06-15 |
Time |
16:18 |
Sent To |
|
|
Notes |
2004-06-15 00:00:00 | ***NOTE *** | | | | ANY AND ALL LIGHTNING PROTECTION SYSTEM | | SHALL BE UNDER SEPARATE PERMIT AND SHALL | | MEET NFPA-780. | | | | PLANS STAMPED AND SIGNED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2004-04-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-04-18 |
Time |
15:10 |
Rev Time |
2.50 |
Received By |
dpalmer |
Date |
2004-04-08 |
Time |
15:08 |
Sent To |
|
|
Notes |
2004-04-18 00:00:00 | ************** UNSAT **************** | | | | 1)NOTE: PLEASE SEE NOTE FROM LAST REVIEW | | PERTAINING TO INFORMATION REQ'D ON TITLE | | BLOCK FOR ENGINEER AND ENGINEERING FIRM. | | PLEASE SEE FAC 61G15-23.002,NAME OF | | ENGINEER, CERTIFICATE OF AUTHORIZATION | | IS REQ'D. PLEASE SEE FS 471.023 | | | | 2)NOTE: IT IS NOTED ON RISER FOR A | | MANUAL MEANS OF DISC FOR ATS/FIRE PUMP | | CONTROLLER BEFORE OPENING OF UNIT, | | HOWEVER SPECS SUBMITTED SHOW ONLY A | | POWER OPERATED MEANS OF DISC. | | PLEASE SEE 230.76/ 230.79/110.27 | | OPENING OF EQUIPMENT IS NOT PERMITTED | | BY FIRE DEPT PERSONNEL. | | PLEASE CLARIFY SIGNAGE NOTES AS REQ'D | | PER 230.2 REQUESTED ON PREVIOUS REVIEW. | | | | | | 3)NOTE: PLEASE SEE LOAD CALCULATIONS | | METER CENTERS SHOWN ON E3.01, THESE | | DO NOT SEEM TO CORRELATE WITH LOADS ON | | E4.01 DPS AND DPN. | | DEMAND KVA DEFERS FROM EACH SHEET. | | NEW COMMENT. | | | | 4)NOTE: PLEASE SEE CIRCUITS SHOWN FOR | | DINING RMM RECEPTS, 14,OR15?. PLEASE | | SEE 210.52B1 DINING RM CIRCUIT REQ'D | | TO BE 20A/ #12. | | NEW COMMENT. | | | | | | 5)NOTE: ONLY A NOTE, REDLINED RECEPT | | W/IN 6' OF DOOR UNIT"C1" E2.05 | | | | 6)NOTE: PLEASE SEE NOTE #10 FROM PREVI- | | -OUS REVIEW. NOTES NEED TO BE ADDED FOR | | HARDWARE AND DOORS PER 110.26 | | RESPONSE MENTIONS DOORS TO BE LOACKED | | AND ACCESSIBLE TO QUALIFIED PERSONNEL. | | PLEASE SEE THIS IS ONLY ONE OF THE | | REQ'MENTS. 110.26CNEEDS TO BE NOTED. | | | | PLEASE SEE FS 553.80(2)(B), A 4X FEE | | FOR PLAN REVIEW HAS BEEN ADDED TO TO | | ANY OF THE SAME COMMENTS FOR THREE OR | | MORE REVIEWS. PLEASE SEE BLDG REVIEW | | COMMETS. THIS FEE IS REQ'D TO BE PAID | | BEFORE RESUBMITTAL OF PLANS. PLEASE | | ALSO NOTE AN ADDITIONAL 10% RESUB FEE | | WILL ALSO BE DUE. | | THE AMOUNTS ARE AS FOLLOWS. | | $133,200.00 4X FEE FOR PLAN REVIEW FS553 | | $22,050.00 FOR 10% RE-SUB FEE. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-11-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-11-04 |
Time |
11:21 |
Rev Time |
5.00 |
Received By |
dpalmer |
Date |
2003-11-04 |
Time |
11:21 |
Sent To |
|
|
Notes |
2003-11-04 00:00:00 | ******************** UNSAT ************* | | | | PLEASE SEE NOTES FROM OTHER REVIEWERS | | THAT MAY HAVE AN AFFECT ON ELECTRICAL | | PLANS. | | | | 1)NOTE: PLEASE SEE 700.16 FOR LIGHTING | | IN ELECTRICAL RMS AND THE LIKE. | | | | 2)NOTE: PLEASE SEE NOTE FOR LIGHTNING | | PROTECTIONS SYSTEM REFERENCES NFPA 78, | | SHOULD READ 780. (MISPRINT). | | | | 3)NOTE: PLEASE CLARIFY MEANS OF EGRESS | | LIGHING ON GRADE LEVEL ACCESS FROM | | GROUND FLR UNITS EXITING TO STREET. | | 210.70 AND LS 101 | | | | 4)NOTE: PLEASE SEE THAT POOL PERMIT WILL | | BE REQ'D TO BE UNDER SEPARATE PERMIT | | ANDWILL REQUIRE A WIRING DIAGRAM FOR | | POOL EQUIPMENT AT THAT TIME. | | | | 5)NOTE: PLEASE SEE PLANS FOR UNITS, | | STARTING AT E2.01. KEYNOTES MENTION FOR | | RECEPTS TO HAVE ARC FAULT PROETCTION, | | HOWEVER, PANEL SCHEDULES MENTION TO SEE | | NOTES AND THOSE NOTES MENTION LTS AND | | RECEPTS? PLEASE SEE 210.12. | | PLEASE SEE THE STATE ADOPTED THE 2002 | | NEC ON 7/1/03. | | | | 6)NOTE: PLEASE SEE THAT WHEN BATHROOMS | | ARE WIRED TO HAVE ALL LIGHTING AND GFI | | RECEPT ON ONE CIRCUIT AS PERMITTED UNDER | | 210.11C3, NO OTHER AREAS INCLUDING | | ADDTIONAL BATH(S) MAY BE FED. PLEASE | | ADJUST ALL CIRCUITING ON PLANS AND | | PANEL SCHEDULES. | | PLEASE ALSO SEE 210.52D FOR A COUPLE OF | | MISSING GFI RECEPTS. (B-5) | | | | 7)NOTE: PLEASE SEE 210.52 FOR RECEPT | | SPACING. PLEASE SEE 2' OF WALL SPACES | | IN MANY UNITS. ONE SET HAS MANY HIGH- | | -LIGHTED ON YELLOW. | | | | 8)NOTE: PLEASE PROVIDE INFORMATION FOR | | FIRE PUMP OCP ETC PER 695.4B | | DISC MEANS? SIGNAGE/NOTES ETC. 230.2, | | 230.72 ETC. | | PLEASE SEE THAT THIS INFORMATION IS | | REQ'D ON THESE PLANS. PLEASE ALSO NOTE | | IF ALL SUBMITTALS FOR GENERATOR SYSTEM | | IS NOT SUBMITTED WITH THIS PACKAGE THEN | | GENERATOR SYSTEM WILL BE REQ'D TO BE | | UNDER SEPARATE PERMITS AND ALL ADDTIONAL | | FEES WILL BE REQ'D AT THAT TIME ALSO. | | | | 9)NOTE: PLEASE PROVIDE INFORMATION FOR | | MSBR, SHOWN AS HAVING 3 SPACES? AS THIS | | EQUIPMENT IS A MLO UNIT. PLEASE CLARIFY | | | | 10)NOTE: PLEASE PROVIDE A NOTE ON ELEC- | | -TRICAL AND BLDG PLANS FOR REQUIREMENTS | | OF 110.26 AND TYPE OF HARDWARE REQ'D | | ON ELECTRICAL ROOM DOORS THAT MEET. | | 110.26 | | | | 11)NOTE: PLEASE SHOW ALL CONTINUOUS LOAD | | -S AT 125% PER 215.3,230.42 ETC. | | INCLUDING LARGEST MOTOR LOADS. | | | | 12)NOTE: PLEASE CLARIFY HOW BOTH PANEL | | "H" AND "HA" ARE SHOWN AS SEC 1O2. | | | | 13)NOTE: PLEASE CLARIFY METHOD OF | | WATER HEATER? | | | | 14)NOTE: PLEASE SEE FAC 61G15-23.002 AND | | PLEASE INCLUDE ALL INFORMATION SET FORTH | | AND REQUIRED PER THIS AND FS 471 | | THIS IS REQ'D FOR ALL TRADES WEATHER OR | | NOT COMMENTED ON. | | | | 15)NOTE: PLEASE SEE COPY OF FS 553.80(2) | | (B) ATTACHED. THIS IS REQ'D TO GO OUT | | ON ANY PROJECT OF REVIEW THAT HAS HAD | | ONE/OR ANY OF THE PREVIOUS COMMENTS THE | | SECOND TIME. THIS IS ONLY A NOTICE. | | | | PLEASE NOTE: A RESPONSE LETTER WILL | | USUALLY HELP THE PROCESS OF PLAN REVIEW | | AND BEING ABLE TO ISSUE PERMIT. | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | INSERT NEW SHEETS INTO TWO COMPLETE SETS | | FOR REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-05-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-05-13 |
Time |
15:36 |
Rev Time |
3.00 |
Received By |
dpalmer |
Date |
2003-05-13 |
Time |
15:36 |
Sent To |
|
|
Notes |
2003-05-13 00:00:00 | *********** UNSAT ****************** | | | | PLEASE COMPLETE PLANS FOR SUFFICIENT | | REVIEW. | | | | PLANS MISSING CIRCUIT #`S,MISSING ITEMS | | LOADS/WIRE/OCP ON PANEL SCHEDULES. | | | | PLEASE SUBMIT MORE INFORMATION FOR FIRE | | PUMP/CONTROLLER ETC. 695-4B,,,,, | | LOCATION OF DISC MEANS, SIGNAGE NOTES, | | ETC. 230-2/-230-72 | | | | PLEASE NOTE, FEEDER SCHEDULE IS SHOWN | | ON RISER, HOWEVER, (#) NOTES ARE NOT | | COMPLETED ON RISER? | | | | PLEASE SEE MISSING CIRCUITING FOR EF`S | | ETC. | | | | PLEASE SEE A COUPLE OF SD`S MISSING. | | TO BE INSIDE AND OUTSIDE ALL SLEEPING | | ROOMS. NFPA-72 8-1.4.2 | | | | PLEASE CLARIFY HOW ALL UNITS SHOW SAME | | LOAD AND UNITS ARE DIFFERENT SIZES?? | | | | | | | | | | PLEASE NOTE, MOST OF THE ABOVE PERTAIN | | TO ART 215-5 | | PLEASE ALSO NOTE, ONCE PLANS ARE | | COMPLETED, THERE MAY BE OTHER COMMENTS | | TO FOLLOW. | | PLEASE SUBMIT ALL OF THE ABOVE INFORMAT- | | -ION FOR REVIEW. PLEASE TAKE OUT ALL OLD | | /VOIDED SHEETS AND SUBMIT COMPLETE SETS | | FOR REVIEW. | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
9 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-05-11 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2006-05-11 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
8 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-05-11 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2006-05-11 |
Time |
|
Sent To |
|
|
Notes |
2006-05-11 00:00:00 | STILL TESTING |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
7 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-05-11 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2006-05-11 |
Time |
|
Sent To |
|
|
Notes |
2006-05-11 00:00:00 | SYSTEM TEST | | SYSTEM TEST |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
6 |
Status |
N |
Date |
2006-05-11 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2006-05-11 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2006-05-11 |
Time |
09:41 |
Sent To |
|
|
Notes |
2006-05-11 00:00:00 | TEST NOTES FOR REVIEWER | | TESTING SYSTEM |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
5 |
Status |
P |
Date |
2006-01-20 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2006-01-20 |
Time |
11:00 |
Rev Time |
0.50 |
Received By |
mamini |
Date |
2006-01-20 |
Time |
11:00 |
Sent To |
|
|
Notes |
2006-01-20 00:00:00 | PASSED: | | | | 1. REVIEWED FOR REVISION SHEETS C-5-C | | AND C-5-D. | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
4 |
Status |
P |
Date |
2005-04-25 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2005-04-25 |
Time |
15:35 |
Rev Time |
0.50 |
Received By |
mamini |
Date |
2005-04-25 |
Time |
15:34 |
Sent To |
|
|
Notes |
2005-04-25 00:00:00 | PASSED: | | | | 1. REVIEWED FOR THE REVISIONS. | | | | 2. PLEASE NOTE THAT WORK WITHIN PUBLIC | | R.O.W REQUIRES PERMIT (R.O.W PERMIT) | | FROM PUBLIC UTILITIES AND ENGINEERING, | | CONTACT WINDEL PALMER 494-1086.PLEASE | | SUBMIT M.O.T PLANS AT THE TIME OF | | APPLICATION. | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2004-04-13 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2004-04-13 |
Time |
10:46 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2004-04-13 |
Time |
10:46 |
Sent To |
|
|
Notes |
2004-04-13 00:00:00 | PASSED WITH PROVISOS: | | 1. INSTALLATION OF SHEET PILLING IN | | PUBLIC R.O.W, REQUIRES A FOOTING AND | | ARIAL FACADE EASEMENT AGREEMENT WITH | | PLANNING DEPARTMENT, 659-8031. | | 2. WORKING IN PUBLIC R.O.W REQUIRES | | PERMIT FROM CITY ENGINEER, RECHARD | | PITTMAN. M.O.T PLANS ALSO MUST BE | | APPROVED PRIOR TO BEGIN WORK. | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2003-11-06 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2003-11-06 |
Time |
08:36 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2003-11-06 |
Time |
08:36 |
Sent To |
|
|
Notes |
2003-11-06 00:00:00 | FAILED: | | 1. PLEASE NOTE THAT A SEPARATE PERMIT | | APPLICATION AND FEES FOR "UNDERGRPOUND | | UTILITIES AND SITE WORK" PERMIT IS | | REQUIRED, SUBMIT TWO SETS OF CIVIL PLANS | | ONLY SIGNED & SEALED, APPROVED & STAMPED | | BY THE PUBLIC UTILITIES AND ENGINEERING. | | 2. PLEASE STATE THAT IF DRANAGE SYSTEM | | FOR THE ENTIRE SITE IS APPROVED BY | | STEVE SARLEY, DRANAGE ENGINEER.HOWEVER | | PERVIOUS AND IMPERVIOUS AREA CALC. | | AND TOTAL SITE AREA MUST BE SUBMITTED AT | | THE TIME OF ACTUAL PERMITTING. | | 3. SHEET C-5 DOES NOT SHOW THE EXISTING | | INLETS AT CORNERS OF S. SAPODILLA AND | | GARDENIA, ARE THEY REMOVED,RELOCATED ? | | 4. WORKING IN PUBLIC R.O.W REQUIRES | | PERMIT FROM CITY ENGINEER, RECHARD | | PITTMAN.M.O.T PLANS FOR WORKING IN | | PUBLIC R.O.W MUST ALSO BE APPROVED BY | | CITY ENGINEER PRIOR TO WORK BEGINS | | 659-8040. | | 5.INSTALLATION OF SHEET PILING IN PUBLIC | | R.O.W AS SHOWN, SHEET C-5 REQUIRES A | | FOOTING AND AERIAL FACADE EASEMENT | | AGREEMENT WITH PLANNING DEPARTMENT, | | 659-8031. | | 6. INSTALLATION OF 8' SAFETY FENCE ALL | | AROUND THE SITE DURING THE CONSTRUCTION | | IS REQUIRED. | | 7. ACCESSIBLE CURB RAMPS AT ALL INTER- | | SECTION CORNERS MUST PROVIDED. | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2003-05-06 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2003-05-06 |
Time |
08:57 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2003-05-06 |
Time |
08:57 |
Sent To |
|
|
Notes |
2003-05-06 00:00:00 | FAILED: | | 1. PLEASE NOTE THAT A SEPARATE PERMIT | | APPLICATION AND FEES FOR UNDERGROUND | | UTILITIES AND SITE WORK IS REQUIRED. | | 2. PLEASE SUBMIT CALCULATION FOR STORM | | WATER AND INCLUDE PERVIOUS & IMPERVIOUS | | AREA FOR ENTIRE SITE. | | 3. ALL CONNECTION TO CITY SERVICES AND | | REMOVAL/ABANDONING OF EXISTING SERVICES | | MUST BE APPROVED BY PUBLIC UTILITIES. | | 4. WORK IN PUBLIC R.O.W REQUIRES A | | SEPARATE PERMIT FROM CITY ENGINEER' | | OFFICE, ATT. RICHARD PITTMAN | | 5. M.O.T PLANS FOR CONSTRUCTION WITHIN | | PUBLIC R.O.W OR ANY LANE CLOSURE MUST BE | | SUBMITTED TO CITY ENGINEER' OFFICE FOR | | APPROVAL PRIOR TO BEGINNING THE WORK. | | 6. ALL SIDEWALKS, CURB & GUTTERS, H.C | | RAMPS ALONGE THE PROPERTY (ALL SIDE) | | THAT ARE REMOVED/DAMAGED MUST BE | | REPLACED PER CITY REQUIREMENTS AND | | DIRECTION. | | 7. POLLUTION/ EROSION PLANS AS SHOWN ON | | SHEET C-11 MUST BE INSTALLED IN FIELD | | PRIOR TO ANY SITE WORKS. | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
21 |
Status |
P |
Date |
2006-08-21 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2006-08-21 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2006-08-21 |
Time |
11:26 |
Sent To |
|
|
Notes |
2006-08-21 00:00:00 | **APPROVED** | | | | | | | | | | PLANS REVIEWED AND OKAYED WERE FA1.01, | | FA1.02 AND FA1.10. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
20 |
Status |
P |
Date |
2006-08-21 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2006-08-21 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2006-08-21 |
Time |
10:20 |
Sent To |
|
|
Notes |
2006-08-21 00:00:00 | FIRE ALARM REVISIONS DATED 06/19/06 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
19 |
Status |
P |
Date |
2006-08-14 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2006-08-14 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2006-08-14 |
Time |
11:22 |
Sent To |
|
|
Notes |
2006-08-14 00:00:00 | **RECEIVED** | | | | | | | | 1.) SPECS AND CUT SHEETS ON FIRE ALARM | | DEVICES. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
18 |
Status |
P |
Date |
2006-06-23 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-06-23 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-06-23 |
Time |
14:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
17 |
Status |
N |
Date |
2006-06-16 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-06-16 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-06-16 |
Time |
11:45 |
Sent To |
|
|
Notes |
2006-06-16 00:00:00 | NO NEW FIRE PROTECTION SHEETS SUBMITTED | | SINCE LAST FIRE REVIEW. ANY REVISIONS | | SUBMITTED FOR FIRE PROTECTION SYSTEMS | | SHALL BE SUBMITTED AS SHOP DRAWINGS | | UNDER THE APPROPRIATE PERMIT. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
16 |
Status |
F |
Date |
2006-04-06 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-04-06 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-04-06 |
Time |
13:45 |
Sent To |
|
|
Notes |
2006-04-06 00:00:00 | ******DENIED****** | | | | REVISION | | | | 1) PLEASE SEE BUILDING REVIEW COMMENT | | REGARDING SIGNING AND SEALING | | REQUIREMENTS. | | | | 2) NEW ARRANGEMENT MUST BE INSPECTED, | | TESTED AND APPROVED BY THIS OFFICE UPON | | INSTALLATION. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
15 |
Status |
P |
Date |
2006-01-05 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-01-05 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-01-05 |
Time |
14:12 |
Sent To |
|
|
Notes |
2006-01-05 00:00:00 | REVISION ELECTRICAL SHTS |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
14 |
Status |
P |
Date |
2005-12-30 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-12-30 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-12-30 |
Time |
14:03 |
Sent To |
|
|
Notes |
2005-12-30 00:00:00 | REVISION DATED 10/19/05 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
13 |
Status |
P |
Date |
2005-10-12 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-10-12 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-10-12 |
Time |
16:03 |
Sent To |
|
|
Notes |
2005-10-12 00:00:00 | REVISIONS DATED 8/16/05, 8/25/05, 9/6/05 | | 8/10/05, 8/3/05, 8/29/05 FOR SHTS A.21, | | A.21A, A.22, A.23, A.24, A.24A, E.1.10, | | E.1.11, E.1.12, E.2.01, E.2.02, E.2.03, | | E.2.04, E.2.05, E.4.02, P.1.03, P.1.10, | | M.2.03, M.2.04. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
12 |
Status |
P |
Date |
2005-08-29 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2005-08-29 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2005-08-29 |
Time |
15:45 |
Sent To |
|
|
Notes |
2005-08-29 00:00:00 | REV A.41,A.42, & A.42A - E1.11 DATED | | 07/22/05 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
11 |
Status |
F |
Date |
2005-08-16 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-08-16 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-08-16 |
Time |
13:12 |
Sent To |
|
|
Notes |
2005-08-16 00:00:00 | ******DENIED****** | | | | PLEASE SEE ELECTRICAL REVIEW COMMENT | | REF: TO LOCATION OF SOME SMOKE | | DETECTORS. | | | | | | MIKE WENNERGREN, CAPTAIN | | WPBFR(561) 804-4756 | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
10 |
Status |
F |
Date |
2005-07-20 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-07-20 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-07-20 |
Time |
15:10 |
Sent To |
|
|
Notes |
2005-07-20 00:00:00 | ******DENIED****** | | | | 1) PLEASE SEE COMMENT BY ELECTRICAL PLAN | | REVIEW IN REGARDS TO EMERGENCY LIGHTING | | IN REQUIRED MEANS OF EGRESS. | | | | | | MIKE WENNERGREN, CAPTAIN | | WPBFR(561) 805-6722 OR 804-4756 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
9 |
Status |
P |
Date |
2005-06-03 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2005-06-03 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2005-06-03 |
Time |
12:50 |
Sent To |
|
|
Notes |
2005-06-03 00:00:00 | FIRE PUMP SUBMITTAL OK |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
8 |
Status |
P |
Date |
2005-06-02 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2005-06-02 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2005-06-02 |
Time |
15:21 |
Sent To |
|
|
Notes |
2005-06-02 00:00:00 | FIRE PUMP SUBMITTALS APPROVED 6-02-05 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
7 |
Status |
P |
Date |
2005-05-09 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-05-09 |
Time |
12:58 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-05-09 |
Time |
12:58 |
Sent To |
|
|
Notes |
2005-05-09 00:00:00 | 1) REVISION DATED 5/5/05 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
6 |
Status |
P |
Date |
2005-02-14 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2005-02-14 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2005-02-14 |
Time |
11:09 |
Sent To |
|
|
Notes |
2005-02-14 00:00:00 | FIRE ALARM SUBMITTAL 02/03/05 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
P |
Date |
2004-06-23 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-06-16 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-06-16 |
Time |
14:20 |
Sent To |
|
|
Notes |
2004-06-16 00:00:00 | 1) ELECTRONIC SWITCHES, CHAIN AND LOCK | | REQUIRED ON FIRE LINE BACKFLOW DEVICE. | | | | 2) TACTILE SIGNAGE REQUIRED AT ALL | | EXITS. | | | | 3) PLEASE LABEL ALL STRETCHER ACCESSIBLE | | ELEVATORS WITH SIGNAGE. | | | | 4) EXIT SIGN NEEDED ADJACENT TO | | BUSINESS CENTER TO DIRECT PERSONS TO | | EXIT SIGN NEAR MAIL ROOM. | | | | 5) VERIFY DOOR SWINGS. DOUBLE DOORS NEAR | | ASST. MANAGER OFFICE SWINGING IN THE | | RIGHT DIRECTION. CORRIDOR 027 SWINGS | | IN. | | | | 6) NO ELECTRIC OR EQUIPMENT ALLOWED WITH | | STAIRWELLS EXCEPT THAT IS ALLOWED UNDER | | NFPA 101, LIFE SAFETY CODE, 2000 EDITION | | CHAPTER SEVEN. | | | | 7) ALL SMOKE DETECTORS SHALL BE A | | MINIMUM OF THREE FEET OF AC DIFFUSERS. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
F |
Date |
2004-03-19 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-03-19 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-03-19 |
Time |
14:20 |
Sent To |
|
|
Notes |
2004-03-19 00:00:00 | 1) HANDRAIL MISSING FROM ONE SIDE OF | | STAIR ON THE EXTERIOR OF THE GENERATOR | | ROOM. | | | | 2) HANDRAILS REQUIRED AT ARCH-6 AT | | SOUTH ELEVATION ON PAGE A.22. | | | | 3) NOTE ON PAGE A-48 IS INCORRECT. ALL | | DOORS MUST COMPLY WITH NFPA 101, CHAPTER | | SEVEN. | | | | 4) DOOR SWINGS IN CORRIDOR ADJACENT TO | | ASST. MGR OFFICE DO NOT APPEAR TO | | SWING IN THE PROPER DIRECTION. | | | | 5) IT APPEARS THAT ADDITIONAL STRIPING | | WILL BE REQUIRED ON THE LOADING DOCK | | ADJACENT TO THE EXIT DOOR LOCATED ON | | THE WEST SIDE. | | | | 6) THE PLACEMENT OF EXIT SIGNS SHALL | | NOT EXCEED 100 FEET. | | | | 7) EXITING FROM THE MAIN ROOF SHALL BE | | OBVIOUS AND DIRECT. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
F |
Date |
2004-02-10 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-02-10 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-02-10 |
Time |
14:28 |
Sent To |
|
|
Notes |
2004-02-10 00:00:00 | 1) PLEASE EXPLAIN HOW STAIRS ON THE | | LOADING DOCK CAN ACCOMODATE THE | | OCCUPANT LOAD FROM STAIR # 1. ALSO | | HOW WILL EXIT DISCHARGE BE MAINTAINED | | FROM THE EXIT DOOR OF STAIR # 1 THROUGH | | THE LOADING DOCK. | | | | 2) PLEASE EXPLAIN COMMENT PERMIT | | RESPONSE # 9. PLEASE CLARIFY. | | | | 3) FIRE ALARM NOTE ON PAGE FA1.03 IS | | INCORRECT. THE FIRE ALARM SYSTEM | | SHALL BE LISTED FOR CENTRAL STATION | | SERVICE. PLEASE REVISE. | | | | 4) ITEMS # 15 AND # 16 SHALL BE | | INDICATED ON THE PLANS. PLEASE REVISE. | | | | 5) NOTE # 18 PERMIT COMMENT RESPONSE | | NEEDS FURTHER CLARIFICATION. ANY | | ELECTRONIC LOCKS ON EXIT DOORS SHALL | | COMPLY WITH ACCESS CONTROL OR | | DELAYED EGRESS. PLEASE REVIEW | | APPLICABLE CODE SECTIONS AND ANNOTE | | PLANS. | | | | 6) HANDRAILS SHALL BE PROVIDED ON ALL | | NEW STAIRS. ALSO HANDRAILS ARE REQUIRED | | WITHIN 30" OF ALL REQUIRED WIDTHS USED | | FOR EXITING. | | | | 7) EXIT SIGN MISSING AT EXTERIOR DOOR | | OF STAIR # 3. | | | | 8) ONLY ONE FIRE HYDRANT SHOWN ON C-5. | | PLEASE CLARIFY. | | | | 9) NOTE # 29, NO PERMIT RESPONSE | | PROVIDED. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2003-10-30 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-10-28 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-10-28 |
Time |
16:59 |
Sent To |
|
|
Notes |
2003-10-30 00:00:00 | 1) STAIR # 4 DOOR ON PAGE A.02 SWINGS | | IN THE WRONG DIRECTION. DOOR SWINGS | | OUT, SHOULD SWING IN. B-2 LEVEL. | | | | 2) SAME CONDITION, SAME LOCATION OCCURS | | ON PAGE A.03. B-1 LEVEL. | | | | 3) PLEASE EXPLAIN EXITING RATIONALE | | FROM THE BUILDING. PLEASE INDICATE | | WHICH STAIRS LEAD DIRECTLY TO THE | | EXTERIOR AT GROUND LEVEL. | | | | 4) COURTYARD AREA DISPLAYS STAIRS ABSENT | | OF HANDRAILS. | | | | 5) PLEASE EXPLAIN HOW EXITING OCCURS | | NEAR THE BIKE STORAGE AREA. IT APPEARS | | THRU THE LOADING DOCK. PLEASE EXPLAIN | | RATIONALE. | | | | 6) STAIR # 1 APPEARS TO DISCHARGE ONTO | | THE LOADING DOCK. PLEASE EXPLAIN. | | | | 7) KNOX-BOX NOT REQUIRED IN FIRE | | COMMAND ROOM. KNOX-BOXES ARE REQUIRED | | TO GAIN ACCESS FROM THE EXTERIOR OF | | THE BUILDING. THEY ARE NOTED ON THE | | DRAWINGS. | | | | 8) ALL PREVIOUSLY PLAN REVIEW COMMENTS | | NOTED ON JUNE 6, 2003 HAVE NOT BEEN | | ADEQUATELY ADDRESSED. | | | | 9) PLEASE EXPLAIN "SMOKE DETECTOR NOTE | | ON FA1.10 CONNECT DELUGE SYSTEM TO | | FIRE ALARM PANEL AS REQUIRED". | | | | 10) FIRE ALARM EQUIPMENT NOTED IN | | STAIR # 2. PLEASE REVIEW CODE SECTIONS | | FOR ITEMS ALLOWED IN STAIRWELL. | | | | 11) ALL FIRE ALARM SYSTEMS THAT | | SUPERVISE AUTOMATIC FIRE SPRINKLER | | SYSTEMS AS OF AUGUST 1, 2003, MUST BE | | UL LISTED FOR CENTRAL STATION SERVICE. | | | | 12) FPS.02 DISPLAYS THREE FIRE | | DEPARTMENT CONNECTIONS. ONLY TWO ARE | | NEEDED. | | | | 13) NOTE # 29 ON FP3.01 IS INCORRECT. | | STANDPIPES ERECTED DURING CONSTRUCTION | | ARE REQUIRED WHEN CONSTRUCTION REACHES | | 30 FEET NOT 50 FEET. | | | | 14) ALL SPRINKLERS SHALL BE QUICK | | RESPONSE TYPE. | | | | 15) TACTILE SIGNAGE REQUIRED AT ALL | | STAIRWELLS. | | | | 16) HOW IS THE 4" PIPING FOR THE | | STANDPIPE SYSTEM THAT RUNS BELOW | | THE POOL DECK GOING TO BE INSPECTED | | OR MAINTAINED IN THE FUTURE. | | | | 17) SMOKE CONTROL NOTES SHALL MENTION | | ANTICIPATED STACK EFFECT. | | | | 18) PLEASE EXPLAIN MAGNETIC LOCKS TIED | | TO FIRE ALARM SYSTEM. LOCKING | | DEVICES ON EXIT DOORS TO COMPLY WITH | | ACCESS CONTROLLED EGRESS WITH ALL | | CODE PARAMETERS BEING MET. | | | | 19) NO REVISIONS COULD BE LOCATED | | ON THE DRAWINGS. | | | | 20) PLEASE PROVIDE PRODUCT APPROVALS | | FOR INSULATION PLANNED FOR AROUND | | TRASH CHUTE. | | | | 21) PLEASE PROVIDE STRENGTH REQUIREMENTS | | FOR HANDRAILS. | | | | 22) ALL CONCRETE STAIRS ON RECREATION | | DECK SHALL BE EQUIPPED WITH HANDRAILS | | ON BOTH SIDES. | | | | 23) HANDRAILS ARE REQUIRED FOR STAIRS | | ON UPPER PLAZA. | | | | 24) PROVIDE CONSTRUCTION DATA. | | | | 25) BUILDING ADDRESS REQUIRED. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2003-06-06 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-06-06 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-06-06 |
Time |
15:53 |
Sent To |
|
|
Notes |
2003-06-06 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | TO, DURING, AND AFTER CONSTRUCTION. | | | | 2) TEMPORARY STANDPIPES ARE REQUIRED | | WHEN CONSTRUCTION REACHES THREE STORIES | | OR THIRTY FEET IN HEIGHT. | | | | 3) EXIT STAIRS ARE REQUIRED DURING | | CONSTRUCTION. | | | | 4) ALL CONSTRUCTION WORK IS TO COMPLY | | WITH NFPA 241. | | | | 5) DOOR AT STAIR # 2 SWINGS OUTWARD | | INSTEAD OF INWARD. | | | | 6) BOTH STAIRS ON L.S.1 ARE LABELED | | STAIR # 2. | | | | 7) PLEASE INDICATE ALL DEVICES AND | | EQUIPMENT THAT WILL BE CONTAINED | | IN THE FIRE COMMAND ROOM. PLEASE SEE | | FBC 412.4.1. | | | | 8) PLEASE PROVIDE MORE DETAILS ON | | SECRUITY LOCKS PLANNED FOR EXIT | | DOORS. | | | | 9) ALL STAIRS AND RAMPS ARE REQUIRED | | TO HAVE HANDRAILS ON BOTH SIDES. | | | | 10) STAIR # 2 AT GROUND LEVEL SWINGS | | INWARD INSTEAD OF OUTWARD. | | | | 11) PLEASE PROVIDE PRESCRIPTIVE STRENGTH | | REQUIREMENTS FOR ALUMINUM AND RAILINGS. | | | | 12) LOCATION MAY BE LOCATED IN THE | | CITY FIRE LIMITS. CERTAIN RESTRICTIONS | | MAY APPLY. | | | | 13) BUILDING ADDRESS REQUIRED ON PROPER | | ELEVATION. | | | | 14) A TWO HOUR FIRE SEPARATION IS | | REQUIRED BETWEEN THE PARKING GARAGE | | AND THE BUILDING. | | | | 15) PROVIDE INFORMATION ON INSULATION | | PLANNED FOR THE TRASH CHUTE. | | | | 16) WHY ARE STAIR # 2 AND STAIR # 3 | | POSITIONED SO CLOSE TOGETHER. | | | | 17) INDICATE TYPE OF CONSTRUCTION. | | | | 18) INDICATE CODE DATA. | | | | 19) VICINITY SPELLED WRONG ON PLANS. | | | | 20) WHY IS THE FIRE PUMP ROOM LOCATED | | ON PARKING LEVEL B-2. | | | | 21) NO EMERGENCY LIGHT NOTED IN FIRE | | PUMP ROOM. | | | | 22) ELECTRICAL CONDUITS NOTED IN STAIR | | # 2. THE STAIR CANNOT BE USED AS A CHASE | | FOR EQUIPMENT. | | | | 23) WHY IS THERE NO EXIT SIGN NEAR | | EXTERIOR DOORS NEAR THE MAIL ROOM. | | | | 24) SMOKE DETECTOR MISSING FROM BEDROOM | | UNIT B-4. | | | | 25) SMOKE DETECTOR MISSING FROM BEDROOM | | UNIT B-3. | | | | 26) FOUR FDC'S SHOWN. THIS OFFICE ONLY | | REQUIRES TWO OF THEM. | | | | 27) FSP # 2 IS LOCATED IN THE ELEVATOR | | LOBBY. IT SHOULD BE RELOCATED FROM | | THIS LOCALE. | | | | 28) CIVIL DRAWINGS SHOW A 6" FIRE LINE. | | THIS LINE IS TWO SMALL. | | | | 29) TAMPER SWITCHES REQUIRED ON FIRE | | LINE BACKFLOW DEVICE. | | | | 30) PLEASE CLEARLY ILLUSTRATE EXISTING | | FIRE HYDRANT LOCATIONS ON SITE PLAN. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 | | 659-8096,EXT.8497 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
130 |
Status |
N |
Date |
2006-10-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-20 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-20 |
Time |
16:45 |
Sent To |
B |
|
Notes |
2006-10-20 16:46:01 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
129 |
Status |
N |
Date |
2006-10-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-05 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-05 |
Time |
14:04 |
Sent To |
B |
|
Notes |
2006-10-05 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
128 |
Status |
N |
Date |
2006-10-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-02 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-02 |
Time |
08:55 |
Sent To |
B |
|
Notes |
2006-10-02 00:00:00 | TO "HPISKURA" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
127 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-23 |
Time |
19:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-23 |
Time |
19:20 |
Sent To |
E |
|
Notes |
2006-09-23 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
126 |
Status |
N |
Date |
2006-09-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-09 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-09 |
Time |
16:13 |
Sent To |
P |
|
Notes |
2006-09-09 00:00:00 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
125 |
Status |
N |
Date |
2006-09-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-06 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-06 |
Time |
16:55 |
Sent To |
|
|
Notes |
2006-09-06 00:00:00 | WAITING FOR "COMM" BD-REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
124 |
Status |
N |
Date |
2006-08-28 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-08-28 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-08-28 |
Time |
11:24 |
Sent To |
|
|
Notes |
2006-08-28 00:00:00 | LETTER TO HAROLD PISKURA TO EXTEND TCO. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
123 |
Status |
N |
Date |
2006-08-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-18 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-18 |
Time |
16:51 |
Sent To |
|
|
Notes |
2006-08-18 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
122 |
Status |
N |
Date |
2006-08-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-16 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-16 |
Time |
11:26 |
Sent To |
M |
|
Notes |
2006-08-16 00:00:00 | TO "M" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
121 |
Status |
N |
Date |
2006-08-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-14 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-14 |
Time |
09:02 |
Sent To |
M |
|
Notes |
2006-08-14 00:00:00 | TO "M" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
120 |
Status |
N |
Date |
2006-08-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-03 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-03 |
Time |
16:54 |
Sent To |
B |
|
Notes |
2006-08-03 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
119 |
Status |
N |
Date |
2006-08-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-01 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-01 |
Time |
14:33 |
Sent To |
B |
|
Notes |
2006-08-01 00:00:00 | 1 "BLDG" REV AND 1 "BLDG" SUBMITTAL TO | | "RBROWN" DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
118 |
Status |
N |
Date |
2006-08-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-01 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-01 |
Time |
14:31 |
Sent To |
E |
|
Notes |
2006-08-01 00:00:00 | TO "DPALMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
117 |
Status |
N |
Date |
2006-07-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-24 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-24 |
Time |
10:29 |
Sent To |
M |
|
Notes |
2006-07-24 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
116 |
Status |
N |
Date |
2006-07-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-15 |
Time |
09:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-15 |
Time |
09:38 |
Sent To |
M |
|
Notes |
2006-07-15 00:00:00 | TO "M" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
115 |
Status |
N |
Date |
2006-07-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-13 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-13 |
Time |
16:34 |
Sent To |
M |
|
Notes |
2006-07-13 00:00:00 | TO "M" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
114 |
Status |
N |
Date |
2006-07-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-13 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-13 |
Time |
14:45 |
Sent To |
B |
|
Notes |
2006-07-13 00:00:00 | REV. TAKEN FROM "COMM" BD#56 AND ROUTED | | TO "RBROWN" DESKADARROUGH |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
113 |
Status |
N |
Date |
2006-07-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-07 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-07 |
Time |
11:28 |
Sent To |
M |
|
Notes |
2006-07-07 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
112 |
Status |
N |
Date |
2006-07-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-06 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-06 |
Time |
09:49 |
Sent To |
Z |
|
Notes |
2006-07-06 00:00:00 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
111 |
Status |
N |
Date |
2006-07-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-05 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-05 |
Time |
10:16 |
Sent To |
B |
|
Notes |
2006-07-05 00:00:00 | TO "RBROWN" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
110 |
Status |
N |
Date |
2006-06-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-13 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-13 |
Time |
11:49 |
Sent To |
FIRE |
|
Notes |
2006-06-30 00:00:00 | TO "F" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
109 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-26 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-26 |
Time |
11:00 |
Sent To |
B |
|
Notes |
2006-06-26 00:00:00 | TO "RBROWN" DESK/SUBMITTAL | | TCO PLAN RE-ROUTED TO HAROLD PISKURA | | 6/26/06 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
108 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-26 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-26 |
Time |
10:55 |
Sent To |
P |
|
Notes |
2006-06-26 00:00:00 | TO "P" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
107 |
Status |
N |
Date |
2006-06-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-23 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-23 |
Time |
16:15 |
Sent To |
|
|
Notes |
2006-07-05 00:00:00 | TO "COMM" BD#4 | 2006-06-23 00:00:00 | WAITING FOR "COMM" BD-REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
106 |
Status |
N |
Date |
2006-06-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-21 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-21 |
Time |
12:36 |
Sent To |
B |
|
Notes |
2006-06-21 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
105 |
Status |
N |
Date |
2006-06-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-14 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-14 |
Time |
15:35 |
Sent To |
M |
|
Notes |
2006-06-14 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
104 |
Status |
N |
Date |
2006-05-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-15 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-15 |
Time |
14:59 |
Sent To |
B |
|
Notes |
2006-05-15 00:00:00 | TO "RBROWN" DESK/ 2 SUBMITTALS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
103 |
Status |
N |
Date |
2006-05-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-11 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-11 |
Time |
12:51 |
Sent To |
Z |
|
Notes |
2006-05-11 00:00:00 | TO "Z" BOX-REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
102 |
Status |
N |
Date |
2006-05-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-03 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-03 |
Time |
09:44 |
Sent To |
|
|
Notes |
2006-05-24 00:00:00 | TO "COMM" BD#33 | 2006-05-03 00:00:00 | WAITING FOR "COMM" BD-REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
101 |
Status |
N |
Date |
2006-04-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-29 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-29 |
Time |
15:00 |
Sent To |
B |
|
Notes |
2006-04-29 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
100 |
Status |
N |
Date |
2006-04-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-24 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-24 |
Time |
16:37 |
Sent To |
B |
|
Notes |
2006-04-24 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
99 |
Status |
N |
Date |
2006-04-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-24 |
Time |
16:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-24 |
Time |
16:31 |
Sent To |
Z |
|
Notes |
2006-04-24 00:00:00 | TO "Z" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
98 |
Status |
N |
Date |
2006-04-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-18 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-18 |
Time |
14:27 |
Sent To |
|
|
Notes |
2006-05-04 00:00:00 | TO "COMM" BD#14-REV | 2006-04-18 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
97 |
Status |
N |
Date |
2006-04-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-14 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-14 |
Time |
08:59 |
Sent To |
|
|
Notes |
2006-05-03 00:00:00 | TO "COMM" BD#56-REV | 2006-04-14 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
96 |
Status |
N |
Date |
2006-03-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-24 |
Time |
18:15 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-03-24 |
Time |
18:15 |
Sent To |
B |
|
Notes |
2006-03-24 00:00:00 | TO RB'S DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
95 |
Status |
N |
Date |
2006-03-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-01 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-01 |
Time |
13:04 |
Sent To |
E |
|
Notes |
2006-03-01 00:00:00 | TO "F" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
94 |
Status |
N |
Date |
2006-03-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-01 |
Time |
12:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-01 |
Time |
12:56 |
Sent To |
M |
|
Notes |
2006-03-01 00:00:00 | TO "M" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
93 |
Status |
N |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-28 |
Time |
18:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-28 |
Time |
18:17 |
Sent To |
M |
|
Notes |
2006-02-28 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
92 |
Status |
N |
Date |
2006-02-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-16 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-16 |
Time |
08:35 |
Sent To |
B |
|
Notes |
2006-02-16 00:00:00 | TO "RBROWN" DESK/SUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
91 |
Status |
N |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-03 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-03 |
Time |
12:45 |
Sent To |
P |
|
Notes |
2006-02-03 00:00:00 | TO "P" BOX/ 2 SUBMITTALS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
90 |
Status |
N |
Date |
2006-02-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-02 |
Time |
18:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-02 |
Time |
18:57 |
Sent To |
Z |
|
Notes |
2006-02-02 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
89 |
Status |
N |
Date |
2006-01-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-22 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-22 |
Time |
11:12 |
Sent To |
M |
|
Notes |
2006-01-22 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
88 |
Status |
N |
Date |
2006-01-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-18 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-18 |
Time |
16:43 |
Sent To |
|
|
Notes |
2006-05-26 00:00:00 | TO "RBROWN" DESK FROM "COMM" BD #1 | 2006-02-09 00:00:00 | TO "COMM" BD#1-REV | 2006-01-18 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
87 |
Status |
N |
Date |
2006-01-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-13 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-13 |
Time |
15:48 |
Sent To |
B |
|
Notes |
2006-01-13 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
86 |
Status |
N |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-29 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-29 |
Time |
08:26 |
Sent To |
E |
|
Notes |
2005-12-29 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
85 |
Status |
N |
Date |
2005-12-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-13 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-13 |
Time |
11:34 |
Sent To |
M |
|
Notes |
2005-12-13 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
84 |
Status |
N |
Date |
2005-12-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-07 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-07 |
Time |
09:25 |
Sent To |
M |
|
Notes |
2005-12-07 00:00:00 | TO "M" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
83 |
Status |
N |
Date |
2005-12-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-06 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-06 |
Time |
16:05 |
Sent To |
|
|
Notes |
2006-01-03 00:00:00 | TO "COMM" BD#21 | 2005-12-06 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
82 |
Status |
N |
Date |
2005-11-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-18 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-18 |
Time |
16:28 |
Sent To |
|
|
Notes |
2005-12-06 00:00:00 | TO "COMM" BD#60 | 2005-11-18 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
81 |
Status |
N |
Date |
2005-11-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-15 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-15 |
Time |
13:33 |
Sent To |
B |
|
Notes |
2005-11-15 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
80 |
Status |
N |
Date |
2005-10-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-11 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-11 |
Time |
13:53 |
Sent To |
B |
|
Notes |
2005-10-11 00:00:00 | TO "RBROWN" DESK/3 SUBMITTALS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
79 |
Status |
N |
Date |
2005-10-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-05 |
Time |
11:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-05 |
Time |
11:16 |
Sent To |
B |
|
Notes |
2005-10-05 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
78 |
Status |
N |
Date |
2005-09-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-13 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-13 |
Time |
09:56 |
Sent To |
|
|
Notes |
2005-09-13 00:00:00 | TO "COMM" BD#17 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
77 |
Status |
N |
Date |
2005-08-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-25 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-25 |
Time |
09:12 |
Sent To |
M |
|
Notes |
2005-08-25 00:00:00 | TO "HMOSER"/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
76 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-18 |
Time |
17:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-18 |
Time |
17:47 |
Sent To |
B |
|
Notes |
2005-08-18 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
75 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-18 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-18 |
Time |
15:49 |
Sent To |
M |
|
Notes |
2005-08-18 00:00:00 | TO "M" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
74 |
Status |
N |
Date |
2005-08-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-03 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-03 |
Time |
11:17 |
Sent To |
B |
|
Notes |
2005-08-03 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
73 |
Status |
N |
Date |
2005-07-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-27 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-27 |
Time |
09:53 |
Sent To |
|
|
Notes |
2005-07-27 00:00:00 | TO "COMM" BD#64 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
72 |
Status |
N |
Date |
2005-07-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-19 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-19 |
Time |
13:54 |
Sent To |
|
|
Notes |
2005-07-20 00:00:00 | TO "COMM" BD#60 | 2005-07-19 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
71 |
Status |
N |
Date |
2005-07-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-19 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-19 |
Time |
08:45 |
Sent To |
B |
|
Notes |
2005-07-19 00:00:00 | TO "RBROWN" DESK/ 2 SUMITTALS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
70 |
Status |
N |
Date |
2005-07-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-08 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-08 |
Time |
11:25 |
Sent To |
B |
|
Notes |
2005-07-08 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
69 |
Status |
N |
Date |
2005-07-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-08 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-08 |
Time |
11:23 |
Sent To |
B |
|
Notes |
2005-07-08 00:00:00 | TO "RBROWN" DESK/3 SUBMITTALS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
68 |
Status |
N |
Date |
2005-07-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-08 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-08 |
Time |
11:20 |
Sent To |
P |
|
Notes |
2005-07-08 00:00:00 | TO "P" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
67 |
Status |
N |
Date |
2005-06-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-06-30 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-06-30 |
Time |
16:23 |
Sent To |
B |
|
Notes |
2005-06-30 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
66 |
Status |
N |
Date |
2005-06-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-06-29 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-06-29 |
Time |
10:18 |
Sent To |
B |
|
Notes |
2005-06-29 00:00:00 | TO "RBROWN" DESK/3 BLDG SUBMITTALS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
65 |
Status |
N |
Date |
2005-06-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-06-22 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-06-22 |
Time |
10:47 |
Sent To |
|
|
Notes |
2005-06-27 00:00:00 | TO "COMM" BD#12 | 2005-06-22 00:00:00 | WAITING FOR SPACE ON "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
64 |
Status |
N |
Date |
2005-06-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-06-21 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-06-21 |
Time |
14:35 |
Sent To |
FIRE |
|
Notes |
2005-06-21 00:00:00 | TO "NMCRAY" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
63 |
Status |
N |
Date |
2005-06-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-20 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-20 |
Time |
15:29 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
62 |
Status |
N |
Date |
2005-06-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-20 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-20 |
Time |
15:01 |
Sent To |
B |
|
Notes |
2005-06-20 00:00:00 | TO RB DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
61 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-08 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-08 |
Time |
10:55 |
Sent To |
B |
|
Notes |
2005-06-08 00:00:00 | TO RB DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
60 |
Status |
|
Date |
2005-05-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-31 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-31 |
Time |
13:34 |
Sent To |
B |
|
Notes |
2005-05-31 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
59 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-24 |
Time |
17:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-24 |
Time |
17:42 |
Sent To |
B |
|
Notes |
2005-05-24 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
58 |
Status |
N |
Date |
2005-05-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-19 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-19 |
Time |
12:47 |
Sent To |
B |
|
Notes |
2005-05-19 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
57 |
Status |
N |
Date |
2005-05-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-19 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-19 |
Time |
12:46 |
Sent To |
B |
|
Notes |
2005-05-19 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
56 |
Status |
N |
Date |
2005-05-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-19 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-19 |
Time |
12:43 |
Sent To |
B |
|
Notes |
2005-05-19 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
55 |
Status |
N |
Date |
2005-05-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-17 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-17 |
Time |
11:01 |
Sent To |
FIRE |
|
Notes |
2005-05-17 00:00:00 | TO "F" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
54 |
Status |
N |
Date |
2005-05-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-12 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-12 |
Time |
16:24 |
Sent To |
FIRE |
|
Notes |
2005-05-12 00:00:00 | TO "F" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
53 |
Status |
N |
Date |
2005-05-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-12 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-12 |
Time |
16:22 |
Sent To |
B |
|
Notes |
2005-05-12 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
52 |
Status |
N |
Date |
2005-05-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-06 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-06 |
Time |
16:06 |
Sent To |
B |
|
Notes |
2005-05-06 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
51 |
Status |
N |
Date |
2005-05-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-06 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-06 |
Time |
16:05 |
Sent To |
B |
|
Notes |
2005-05-06 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
50 |
Status |
N |
Date |
2005-05-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-06 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-06 |
Time |
16:04 |
Sent To |
B |
|
Notes |
2005-05-06 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
49 |
Status |
N |
Date |
2005-05-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-06 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-06 |
Time |
16:03 |
Sent To |
B |
|
Notes |
2005-05-06 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
48 |
Status |
N |
Date |
2005-05-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-03 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-03 |
Time |
13:40 |
Sent To |
B |
|
Notes |
2005-05-03 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
47 |
Status |
N |
Date |
2005-04-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-29 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-29 |
Time |
08:54 |
Sent To |
B |
|
Notes |
2005-04-29 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
46 |
Status |
N |
Date |
2005-04-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-29 |
Time |
08:53 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-29 |
Time |
08:53 |
Sent To |
B |
|
Notes |
2005-04-29 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
45 |
Status |
N |
Date |
2005-04-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-29 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-29 |
Time |
08:52 |
Sent To |
B |
|
Notes |
2005-04-29 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
44 |
Status |
N |
Date |
2005-04-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-29 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-29 |
Time |
08:52 |
Sent To |
B |
|
Notes |
2005-04-29 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
43 |
Status |
N |
Date |
2005-04-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-28 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-28 |
Time |
10:53 |
Sent To |
B |
|
Notes |
2005-04-28 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
42 |
Status |
N |
Date |
2005-04-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-28 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-28 |
Time |
10:52 |
Sent To |
B |
|
Notes |
2005-04-28 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
41 |
Status |
N |
Date |
2005-04-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-25 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-25 |
Time |
11:24 |
Sent To |
ENG |
|
Notes |
2005-04-25 00:00:00 | TO "MAMINI" DESK/REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
40 |
Status |
N |
Date |
2005-04-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-15 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-15 |
Time |
15:26 |
Sent To |
|
|
Notes |
2005-04-15 00:00:00 | TO "COMM" BD#38 W/ PLANS THAT CAME IN ON | | 4/6/05ADARROUGH |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
39 |
Status |
N |
Date |
2005-04-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-12 |
Time |
17:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-12 |
Time |
17:26 |
Sent To |
B |
|
Notes |
2005-04-12 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
38 |
Status |
N |
Date |
2005-04-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-08 |
Time |
08:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-08 |
Time |
08:25 |
Sent To |
|
|
Notes |
2005-04-08 00:00:00 | TO "COMM" BD#38 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
37 |
Status |
N |
Date |
2005-04-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-04 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-04 |
Time |
16:40 |
Sent To |
B |
|
Notes |
2005-04-04 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
36 |
Status |
N |
Date |
2005-03-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-29 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-29 |
Time |
11:27 |
Sent To |
M |
|
Notes |
2005-03-29 00:00:00 | TO "PKRAUSS" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
35 |
Status |
N |
Date |
2005-03-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-25 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-25 |
Time |
09:20 |
Sent To |
B |
|
Notes |
2005-03-25 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
34 |
Status |
N |
Date |
2005-03-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-21 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-21 |
Time |
16:50 |
Sent To |
B |
|
Notes |
2005-03-21 00:00:00 | TO "RBROWN"DESK/REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
33 |
Status |
N |
Date |
2005-03-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-17 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-17 |
Time |
09:50 |
Sent To |
B |
|
Notes |
2005-03-17 00:00:00 | TO "RBROWN"DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
32 |
Status |
N |
Date |
2005-03-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-15 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-15 |
Time |
14:07 |
Sent To |
B |
|
Notes |
2005-03-15 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
31 |
Status |
N |
Date |
2005-03-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-15 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-15 |
Time |
14:01 |
Sent To |
B |
|
Notes |
2005-03-15 00:00:00 | TO "RBROWN"DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
30 |
Status |
N |
Date |
2005-03-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-11 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-11 |
Time |
10:33 |
Sent To |
B |
|
Notes |
2005-03-11 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
29 |
Status |
N |
Date |
2005-02-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-25 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-25 |
Time |
15:34 |
Sent To |
B |
|
Notes |
2005-02-25 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
28 |
Status |
N |
Date |
2005-02-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-25 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-25 |
Time |
14:56 |
Sent To |
B |
|
Notes |
2005-02-25 00:00:00 | TO "RBROWN"DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
27 |
Status |
N |
Date |
2005-02-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-18 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-18 |
Time |
08:35 |
Sent To |
B |
|
Notes |
2005-02-18 00:00:00 | TO RBROWN DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
26 |
Status |
N |
Date |
2005-02-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-14 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-18 |
Time |
08:35 |
Sent To |
B |
|
Notes |
2005-02-14 00:00:00 | TO RBROWN DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
25 |
Status |
N |
Date |
2005-02-10 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-02-10 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-02-10 |
Time |
10:31 |
Sent To |
B |
|
Notes |
2005-02-10 00:00:00 | TO "RB" DESK/SUBMITTALS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
24 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-02-05 |
Time |
06:45 |
Sent To |
|
|
Notes |
2005-02-05 00:00:00 | REVISION,P-TRAPS AT 30" TRANSFERE SLAB. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
23 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-04 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-04 |
Time |
14:44 |
Sent To |
B |
|
Notes |
2005-02-04 00:00:00 | TO RBROWN DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
22 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-04 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-04 |
Time |
14:16 |
Sent To |
B |
|
Notes |
2005-02-04 00:00:00 | TO RBROWN DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
21 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-04 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-04 |
Time |
14:10 |
Sent To |
B |
|
Notes |
2005-02-04 00:00:00 | TO RBROWN DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
20 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-04 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-04 |
Time |
14:22 |
Sent To |
B |
|
Notes |
2005-02-04 00:00:00 | TO "F"BOX/SUBMITTAL | | TO R.BROWN DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
19 |
Status |
N |
Date |
2005-01-21 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-21 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-21 |
Time |
16:43 |
Sent To |
B |
|
Notes |
2005-01-21 00:00:00 | TO "RB" DESK/SUBMITTALS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
18 |
Status |
N |
Date |
2005-01-14 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-14 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-14 |
Time |
15:31 |
Sent To |
B |
|
Notes |
2005-01-14 00:00:00 | TO "RB" DESK./SUBMITTALS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
17 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-11 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-11 |
Time |
16:07 |
Sent To |
P |
|
Notes |
2005-01-11 00:00:00 | TO "P" BOX./SUBMITTAL. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
16 |
Status |
N |
Date |
2004-12-20 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-20 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-20 |
Time |
14:09 |
Sent To |
B |
|
Notes |
2004-12-20 00:00:00 | SENT TO "RB" DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
15 |
Status |
N |
Date |
2004-12-20 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-20 |
Time |
13:29 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-20 |
Time |
13:29 |
Sent To |
P |
|
Notes |
2004-12-20 00:00:00 | SENT TO "P" BOX./REV. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
14 |
Status |
N |
Date |
2004-12-14 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-14 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-14 |
Time |
10:31 |
Sent To |
B |
|
Notes |
2004-12-14 00:00:00 | SENT TO "RB" DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2004-11-24 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-11-24 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-11-24 |
Time |
16:13 |
Sent To |
P |
|
Notes |
2004-11-24 00:00:00 | SENT TO "P" BOX./REV. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2004-11-22 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-20 |
Time |
14:11 |
Rev Time |
|
Received By |
mjacobs |
Date |
2004-11-22 |
Time |
08:07 |
Sent To |
|
|
Notes |
2004-11-22 00:00:00 | SENT TO COMM BD#35/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2004-11-22 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-11-22 |
Time |
08:00 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-11-22 |
Time |
08:01 |
Sent To |
B |
|
Notes |
2004-11-22 00:00:00 | SENT TO RB DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2004-11-15 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-11-15 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-11-15 |
Time |
09:25 |
Sent To |
B |
|
Notes |
2004-11-15 00:00:00 | TO RB DESK/2 SUBMITTALS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2004-11-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-11-02 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-11-02 |
Time |
16:40 |
Sent To |
B |
|
Notes |
2004-11-02 00:00:00 | TO RB DESK/SUBMITTAL | | WATERPROOFING-THORSEAL 0002-07900-0 | | WATERPROOFING BENTONITE 0001-07900-0 | | CONCRETE SLAB JOINTS 0004-03100-0 | | CONCRETE MIXDESIGNS 0001-03300-0 | | CONCRETE REINFORCEMENT 0001-03200-1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2004-10-05 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-05 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-05 |
Time |
11:10 |
Sent To |
B |
|
Notes |
2004-10-05 00:00:00 | TO RB DESK/REV | | PER LETTER ATTACHED/HURRICAN HELP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2004-08-26 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-26 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-26 |
Time |
10:27 |
Sent To |
B |
|
Notes |
2004-08-26 00:00:00 | TO RB DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2004-06-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-03 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-06-03 |
Time |
15:14 |
Sent To |
|
|
Notes |
2004-06-03 00:00:00 | TO COMM BD#9 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2004-03-12 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-03-12 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-03-12 |
Time |
10:01 |
Sent To |
|
|
Notes |
2004-03-12 00:00:00 | TO COMM BD#3 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-02-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-06 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-06 |
Time |
12:43 |
Sent To |
|
|
Notes |
2004-02-06 00:00:00 | TO COMM BD#26 INCLUDING Z |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-24 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-24 |
Time |
14:05 |
Sent To |
|
|
Notes |
2003-10-24 00:00:00 | TO COMM BD#51/PLANS ON TO SHELF RIGHT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-10-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-16 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-16 |
Time |
16:41 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-05-05 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-05 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-05 |
Time |
13:04 |
Sent To |
|
|
Notes |
2003-05-05 00:00:00 | COMM BOARD #24.PLANS NEXT TO CONF ROOM |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
27 |
Status |
P |
Date |
2006-09-12 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-09-12 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-09-12 |
Time |
11:43 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
26 |
Status |
P |
Date |
2006-08-25 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-08-25 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-08-25 |
Time |
09:16 |
Sent To |
|
|
Notes |
2006-08-25 00:00:00 | REVISED SHEET M1.03 - | | 1) REVISED THE INSULATION JACKET FOR THE | | MUFFLER TO THE EMERGENCY GENERATOR. | | | | 2) REVISED THE BUSINESS CENTER ROOM, | | REMOVED DOOR TO ELIMATE THE RETURN AIR | | DUCT. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
25 |
Status |
F |
Date |
2006-08-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-08-18 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-08-18 |
Time |
14:07 |
Sent To |
|
|
Notes |
2006-08-18 00:00:00 | DENIED: | | CODE SPECIFICALLY STATES MAXIMUM LENGTH | | 25FT WITH REDUCTIONS FOR 90 DEGREE BENDS | | WITH THE EXCEPTION "PER MANUFACTURER'S | | SPECIFICATIONS", OR SHAFT ENCLOSURE. | | THIS SUBMITTAL DOES NOT COMPLY WITH ANY | | OF THE OPTIONS ALLOWED BY CODE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719 OR | | E-MAIL [email protected]. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
24 |
Status |
P |
Date |
2006-07-10 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-07-10 |
Time |
08:26 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2006-07-10 |
Time |
08:26 |
Sent To |
|
|
Notes |
2006-07-10 00:00:00 | REVISION TO MECH. PLANS PAGE M4.01 AND | | M7.01 . |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
23 |
Status |
P |
Date |
2006-06-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2006-06-19 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2006-06-19 |
Time |
10:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
22 |
Status |
P |
Date |
2006-06-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2006-06-19 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2006-06-19 |
Time |
10:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
21 |
Status |
P |
Date |
2006-06-16 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-06-16 |
Time |
09:00 |
Rev Time |
1.00 |
Received By |
tgordon |
Date |
2006-06-16 |
Time |
09:00 |
Sent To |
|
|
Notes |
2006-06-16 00:00:00 | MECH. REVISION TO PAGE M1.03 & M2.05 . |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
20 |
Status |
P |
Date |
2006-06-02 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-06-02 |
Time |
16:05 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-06-02 |
Time |
16:04 |
Sent To |
|
|
Notes |
2006-06-02 00:00:00 | REVISION TO MECH. PLAN PAGE M1.03 . |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
19 |
Status |
F |
Date |
2006-04-12 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2006-04-12 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2006-04-12 |
Time |
10:45 |
Sent To |
|
|
Notes |
2006-04-12 00:00:00 | PLAN DENIED | | 1) REVISON MUST BE SIGNED AND SEALED. | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
18 |
Status |
N |
Date |
2006-03-12 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2006-03-12 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2006-03-12 |
Time |
09:26 |
Sent To |
P |
|
Notes |
2006-03-12 00:00:00 | ALL LETTERS PROVIED ARE FOR PLUNBING NOT | | MECHANICAL.3/12/05 HM. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
17 |
Status |
P |
Date |
2006-03-02 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-03-02 |
Time |
06:35 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-03-02 |
Time |
06:35 |
Sent To |
|
|
Notes |
2006-03-02 00:00:00 | PROVISO:REVISED SHEETS M2.06 & M2.07 | | | | PLANS INDICATE NO COMBUSTIBLES ALLOWED | | IN THE RETURN AIR PLENUM.PLEASE NOTE, | | THIS INCLUDES THE DOOR AND THE DOOR | | FRAME. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
16 |
Status |
P |
Date |
2006-02-10 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2006-02-10 |
Time |
07:34 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2006-02-10 |
Time |
07:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
15 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2006-02-03 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2006-02-03 |
Time |
13:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
14 |
Status |
P |
Date |
2006-01-24 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-01-24 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-01-24 |
Time |
13:59 |
Sent To |
|
|
Notes |
2006-01-25 00:00:00 | REVISED SHEETS M1.09, M1.10, M4.02. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
13 |
Status |
P |
Date |
2006-01-05 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2006-01-05 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2006-01-05 |
Time |
11:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
12 |
Status |
P |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-12-29 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-12-29 |
Time |
09:56 |
Sent To |
|
|
Notes |
2005-12-29 00:00:00 | PASS PRIVISO | | PLEASE REMOVE FIRE DAMPER FROM STAIRWELL | | PRESSURIZATION DUCT IN AIR INTAKE WELL | | ON THE PLANS PAGE M1.01.PLEASE RESUBMIT | | THIS PAGE FOR REVISION. | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
11 |
Status |
P |
Date |
2005-11-09 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-11-09 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-11-09 |
Time |
10:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
10 |
Status |
P |
Date |
2005-08-26 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-08-26 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-08-26 |
Time |
10:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
9 |
Status |
P |
Date |
2005-08-01 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-08-01 |
Time |
07:47 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-08-01 |
Time |
07:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
8 |
Status |
P |
Date |
2005-07-18 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-07-18 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-07-18 |
Time |
13:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
7 |
Status |
F |
Date |
2005-06-04 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-06-04 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-06-04 |
Time |
07:45 |
Sent To |
|
|
Notes |
2005-06-04 00:00:00 | 1 PAGE M1.01 CAN NOT TAKE AIR FRON | | GARAGE TO PRESSUREISE STAIR TOWERS. | | 2 PLEASE PROVIDE DOOR SCHEDULE PAGE A-48 | | MISSING FROM PLANS.PLEASE PROVIDE TYPE | | OF DOOR USED FOR A/C CLOSITS IN SUITES. | | 3 PLEASE SHOWDETAIL ON PLANS FOR | | RETURN AIR IN THE SUITES,FROM RETURN AIR | | GRILL TO A/C. UNITS. | | 4 PAGE M2.05 STUDIO 1 SHOWES BOOSTER FAN | | IN DRYER EXHAUEST.REFER TO SECTION 504.6 | | DOMESTIC CLOTHES DRYER DUCT,BOOSTER FANS | | ARE NOT AN EXCEPTION. | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
N |
Date |
2005-03-01 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-03-01 |
Time |
09:54 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2005-03-01 |
Time |
09:22 |
Sent To |
|
|
Notes |
2005-03-01 00:00:00 | SUBMITTAL LETER DATED 2-7-05, RE: | | BATHROOM & LAUNDRY EXHAUST | | 1.DRYER BOOSTER FANS WILL HAVE TO BE | | SUBMITTED UNDER "ALTERNATE MATERIALS AND | | METHODS" PER 2001 FBC 103.7.1.PROVIDE | | THE FOLLOWING DOCUMENTATION FOR REVIEW | | BY NEIL MELICK, BUILDING OFFICAL: | | 1.SUBMITTAL DATA/INSTALLATION | | INSTRUCTIONS FOR THE DRYER. | | | | 2.SIGNED, SEALED AND DATED LETTER BY | | THE ENGINEER FROM THE MANUFACTURER | | INDICATING THAT THIS APPLICATION IS | | APPROVED BY THE MANUFACTURER AND WILL | | NOT VOID THE WARRANTY OF THE DRYER. | | | | 3.SUBMITTAL DATA/INSTALLATION | | INSTRUCTIONS FOR THE BOOSTER FAN. | | | | CONCERNING THE ISSUE OF THE TERMINATION | | OF THE BATHROOM AND LAUNDRY EXHAUST | | TERMINATING ONTO THE BALCONY, THIS MUST | | BE RESOLVED WITH HAROLD MOSER, CHIEF | | MECHANICAL INSPECTOR AS I HAD APPROVED | | THIS ON THE PLAN REVIEW. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2004-06-24 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-06-24 |
Time |
11:22 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2004-06-24 |
Time |
11:01 |
Sent To |
|
|
Notes |
2004-06-24 00:00:00 | JACK NEDLIN, ENGINEER (STEVEN FELLER, | | INC) CORRECTED PLAN SHEETS M1.01, M1.02 | | AND REPLACED IN SUBMITTED SET.PLAN | | SHEETS M1.03 & M1.04, ENGINEER MADE | | NOTES & SIGNED.M1.03, DUCT AT CEILING | | OF STAIRWELL - THIS WILL HAVE A MINIMUM | | OF 1 HR LID AND WILL NOT IMPEDE THE | | STAIRWELL.PLAN SHEET M1.04, CHANGED | | NOTE INDICATING PROPER WG. (MIN 0.05" | | WG TO 0.35 " WG MAX).CHANGED SEQUENCE | | FOR THE DAMPERS ON SMOKE CONTROL. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2004-06-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-06-18 |
Time |
14:15 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2004-06-18 |
Time |
14:15 |
Sent To |
|
|
Notes |
2004-06-18 00:00:00 | DENIED: | | PLAN SHEETS M1.01 THROUGH M1.03: | | M1.01 GRILLE AT 2 HR WALL, FIRE DAMPER | | REQUIRED. | | | | M1.02, CW PIPE PENTRATING STAIRWELL. | | PENETRATION PROHIBITED PER 2001 FBC | | 1006.1.3.1. | | | | M1.03, DUCT THROUG STAIRWELL, | | PENETRATION PROHIBITED PER 2001 FBC | | 1006.1.3.1. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2004-04-20 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-04-10 |
Time |
10:12 |
Rev Time |
3.00 |
Received By |
pkrauss |
Date |
2004-04-10 |
Time |
10:12 |
Sent To |
|
|
Notes |
2004-04-10 00:00:00 | DENIED: | | REFERENCE RESPONSE #12: | | 1.PLAN SHEET M6.03 VERTICAL HEAT PUMP | | DETAIL, PER 2001 FBC(M) 307.2.4, THE | | CODE IS VERY SPECIFIC DRAIN PANS ARE TO | | BE BE INSTALLED WHERE POSSIBLE, THE | | ALTERNATIVE IS A DRAIN PAN SECURED ALONG | | SIDE THE UNIT WITH A DRAIN LINE OR A | | LEVEL DETECTOR.THE LEVEL DETECTOR IS | | NOT TO BE INSTALLED IN THE PRIMARY DRAIN | | PAN AS INDICATED. | | | | REFERENCE RESPONSE #13: | | 1.PLANS INDICATE CO SENSORS PLANS DO | | NOT INDICATE AT WHAT LEVEL (PPM) THE | | SENSORS ARE SET.PER 2001 FBC 411.4.2 | | & 412.5 THE MECHANICAL SYSTEM IS TO | | PROVIDE A MINIMUM OF 6 AIR CHANGES PER | | HOUR & BE CONTINUOUSLY VENTILATED WITH | | SUPPLY AND EXHAUST. | | | | 2.PLEASE NOTE, RE-LOCATION OF EXHAUST | | FANS FOR GARAGE VENTILATION.WILL THIS | | BE EFFECTIVE FOR REMOVAL OF CARBON | | MONOXIDE?PLEASE PROVIDE INFORMATION | | AS TO HOW THE CO SENSORS WILL BE | | TESTED. | | | | 3.PLANS INDICATE OUTSIDE AIR FOR THE | | CONDO UNITS BY INFILTRATION.PER 2001 | | FBC(M) 403.3, VENTILATION SYSTEMS FOR | | OTHER THAN ONE & TWO FAMILY DWELLING | | SHALL BE DESIGNED TO SUPPLY THE MINIMUM | | OF OUSTIDE AIR PER TABLE 403.3. | | PER 2001 FBC(M) 403.2.1 #1 VENTILATION | | AIR SHALL NOT BE RECIRCULATED FROM ONE | | OCCUPANCY TYPE TO ANOTHER. | | | | REFERENCE RESPONSE #11: | | 1.PLAN SHEET M4.01 NOTE C, PLEASE | | CLARIFY, WHEN BUILDING GOES INTO ALARM, | | EXHAUST FIRE/SMOKE DAMPERS ON ALL FLOORS | | FOR THE CORRIDORS WILL OPEN & THE SUPPLY | | FIRE/SMOKE DAMPERS WILL CLOSE ON THE | | FLOOR OF INCIDENCE IS THIS CORRECT? | | | | 2.FLOOR PLAN INDICATES OA 1 & 2 FOR | | OUTSIDE AIR TO CORRIDORS THE SCHEDULE | | INDICATES RTU'S.PLEASE CORRELATE | | RISERS WITH THE SCHEDULE. | | | | 3.PLAN SHEET M1.03 THROUGH M1.09 | | INDICATES "CEA" FOR THE CORRIDOR EXHAUST | | & EXHAUST SCHEDULE (M5.02) INDICATES | | "SEF". PLEASE CORRELATE RISERS WITH | | THE SCHEDULE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2003-11-19 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-11-19 |
Time |
09:21 |
Rev Time |
8.00 |
Received By |
pkrauss |
Date |
2003-11-05 |
Time |
16:49 |
Sent To |
|
|
Notes |
2003-11-19 00:00:00 | DENIED: | | PLEASE PROVIDE TRANSMITTAL LETTER WITH | | RESPONSES TO COMMENTS TO HELP EXPEDITE | | PLANS IN A MORE TIMELY MANNER. | | | | 1.PLAN SHEET A.45B DETAIL G, DRYER | | VENT TO BE NON-SCREENED WITH A BACKDRAFT | | DAMPER AND SHALL NOT PASS THRU PLENUMS | | PER 2001 FBC(M) 504.4. | | | | 2.PLAN SHEET M1.03 CLARIFY MAKE-UP AIR | | NEXT TO STAIRWELL PRESSURE RELIEF | | (EXHAUST). | | | | 3.M1.03-INDICATES FLAMEBAR DUCT IN | | STAIRWELL. PER 2001 FBC 1006.1.3.1, NO | | DUCT PENETRATIONS THROUGH A STAIRWELL | | EXCEPT FOR STAIRWELL PRESSURIZATION. | | PLEASE PROVIDE SUBMITTAL FOR THE | | FLAMEBAR DUCT. | | | | 4.M1.03-PROVIDE MANUFACTURER SUBMITTAL | | DATA ON THE GENERATOR WILL THERE BE A | | FILL TANK OR STORAGE? | | | | 5.SUPPLY DUCT FROM HP-G-1 APPEARS TO | | PENETRATE A RATED WALL AT THE ELEVATOR | | LOBBY AREA.FIRE DAMPERS ARE NOT | | REQUIRED AS LONG AS ALL THE CONDITIONS | | OF 607.1.3. | | | | 6.FLOORS 2 THRU 8 SUPPLY DUCT FROM | | HP-C-1 REQUIRE A FIRE DAMPER AT THE | | PENETRATION THRU THE WALL TO THE | | CORRIDOR. | | | | 7.M1.03 THRU M1.09 INDICATE DOORS WITH | | UNDERCUTS AND LOUVERS ARE THESE FIRE | | RATED CORRIDORS?PLEASE CLARIFY. | | | | 8.M1.03 FIRE/SMOKE DAMPERS MISSING | | FROM HP-G-5 WHERE DUCT PASSES THRU RATED | | WALLS.PLEASE CLARIFY. | | | | 9.M2.01 & OTHERS INDICATE EXHAUST ON | | TERMINATING ONTO THE TERRANCE PLEASE | | NOTE PER 2001 FBC(M) 401.5.2, EXHAUST | | OPENINGS SHALL BE LOCATED SO AS NOT | | CREATE A NUISANCE. EXHAUST AIR SHALL NOT | | DIRECTED ONTO WALKWAYS. | | | | 10. M2.01 NOTE ON PLAN INDICATES SPECFIC | | DRYERS TO BE INSTALLED FOR INCREASED | | VENTING CAPABILITY.PLEASE PROVIDE | | MANUFACTURER SPECS FOR DRYER.DRYERS | | TO BE INSTALLED FOR FINAL INSPECTION. | | | | 11. M.401 SMOKE CONTROL - PRESSURIZATION | | OF CORRIDOR PLEASE CLARIFY HOW THIS | | COMPLYS WITH 2001 FBC 412.5.WHERE WILL | | THE SMOKE ON THE FLOOR OF INCIDENT BE | | MIDIGATED TO? | | | | 12. AUXILIARY DRAIN PANS REQUIRED PER | | 2001 FBC(M) 307.2.3. | | | | 13. PROVIDE OUTSIDE AIR CALCULATIONS FOR | | ALL AREAS COMMON AND RESIDENTIAL PER | | 2001 FBC(M) 403.3. | | | | 14. PROVIDE CALCULATIONS FOR COMBUSTION | | AIR IN THE BOILER ROOM.PROVIDE MIMINUM | | AIR REQUIREMENTS FOR ALL THE MECHANICAL | | ROOMS.INDICATE CALCULATIONS ON PLAN. | | | | 15. PLEASE NOTE EXHAUST CONTAINING | | NOXIOUS FUMES, DUST PARTICALS OR SMOKE | | SHALL BE LOCATED A MINIMUM OF 10 FT | | FROM ANY FRESH AIR INTAKE (INCLUDING | | DOORS AND WINDOWS). | | | | 16. PLEASE INDICATE IF ANY OF THE | | APPLIANCES ARE GAS. | | | | 17. PLEASE NOTE AS PER FS 471.025 AND | | FAC 61G15-23.003, ALL PLANS SHALL BE | | SIGNED (NOT INITIALED), SEALED AND DATED | | BY THE ENGINEER OF RECORD.PLEASE | | REVISE PLANS TO COMPLY. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-05-24 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-05-24 |
Time |
10:41 |
Rev Time |
4.00 |
Received By |
pkrauss |
Date |
2003-05-24 |
Time |
10:40 |
Sent To |
|
|
Notes |
2003-05-24 00:00:00 | DENIED:MECHANICAL PERMIT 03050109 | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | FOR REVIEW: | | | | 1.PLAN SHEET M1.03 DUCTS PENETRATING | | WALLS WITH 1 HR RATING AT THE LOCATION | | OF THE MAIL RM, STORAGE RM & PUBLIC | | BATHROOMS.PLEASE INDICATE LOCATION OF | | THE FIRE DAMPERS. | | | | 2.PLAN SHEET 2.01, LINT TRAP WITH FAN | | BOOSTER INDICATED ON PLAN.PLAN SHEET | | M6.21 INDICATES A SUB-DUCT.PLEASE | | CLARIFY WHICH WILL BE USED. PLEASE NOTE, | | SHOULD THE SUBDUCT METHOD BE USED CLEAN- | | OUTS & SPRINKLER SYSTEM REQUIRED IN THE | | 2 HR SHAFT.SHOULD THE BOOSTER FAN | | METHOD BE USED PLEASE PROVIDE DETAIL | | OF "LINT TRAP".BOOSTER FAN MUST HAVE | | SOME TYPE OF NOTIFICATION IF IT FAILS. | | | | 4.PLEASE PROVIDE ELEVATION AT WHICH | | THE MUFFLER EXHAUST FROM THE GENERATOR | | WILL TERMINATE. | | | | 5.PLEASE PROVIDE OUTSIDE AIR CALCS | | FOR ALL AREAS COMMON AS WELL AS | | RESIDENTIAL.RESIDENTIAL CAN BE BY | | NATURAL MEANS AS PER 2001 FBC(M) 402.2 | | OR MECHANICAL TABLE 403.3. | | | | 6.A MINIMUM OF 4" CLEARANCE REQUIRED | | AROUND THE VERTICAL AHU AS PER 2001 FBC | | (M) 603.1.3. | | | | 7.AS PER 2001 FBC 411.4.2, THE | | MECHANICAL SYSTEM SHALL BE CAPABLE OF | | PROVIDING AT LEAST 6 AIR CHANGES PER | | HOUR FOR EACH LEVEL. | | | | 8.PLEASE PROVIDE CALCULATIONS FOR | | GARAGE, BOILER ROOM AND ALL EQUIPMENT | | AND MECHANICAL ROOMS. | | | | 9.PLEASE NOTE, MASTER BATHROOMS WHERE | | THE TOILET ROOM IS SEPARATE FROM THE | | BATHING AREA, A FAN WILL BE REQUIRED | | IN THE SHOWER AREA AS WELL AS THE TOILET | | AREA AS PER 2001 FBC(M) 402.3.1. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
22 |
Status |
P |
Date |
2006-07-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-07-26 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-07-26 |
Time |
10:22 |
Sent To |
|
|
Notes |
2006-07-26 00:00:00 | REVISIONS APPROVED - SHTS (8.5X11) SK-3, | | SK-4, & SK-5 PLANTER DRAIN 2 NE PLAZA | | WITH RISER CHANGE TO REFLECT CHANGES TO | | SHEETS P1.02, P1.03, & P3.09 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
21 |
Status |
P |
Date |
2006-06-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-06-21 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-06-21 |
Time |
16:55 |
Sent To |
|
|
Notes |
2006-06-21 00:00:00 | REVISION OK - SHTS P101, P102, P103, | | P301C, P302, P305, P309, P310 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
20 |
Status |
P |
Date |
2006-06-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-06-21 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-06-21 |
Time |
16:53 |
Sent To |
|
|
Notes |
2006-06-21 00:00:00 | REVISION OK - SHTS P101, P102, P103, | | P103C, P305, P401, P402. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
19 |
Status |
P |
Date |
2006-03-14 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2006-03-14 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2006-03-14 |
Time |
10:18 |
Sent To |
PC |
|
Notes |
2006-03-14 00:00:00 | SUBMITTAL FOR APPROVAL, LOCATION OF BACK | | FLOW PREVENTERS OVER EXHAUST GRATING. | | PRIOR APPROVAL FROM WPBUD, PRE ORVILLE | | POLK. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
18 |
Status |
F |
Date |
2006-03-08 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-03-08 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-03-08 |
Time |
09:52 |
Sent To |
|
|
Notes |
2006-03-08 00:00:00 | REVISION DENIES | | | | | | SHTS P1.03, P3.02, AND P3.06 DELETED THE | | DRINKING FOUNTAIN, DWV PIPING AND THE | | WATER SUPPLY TO DRINKING FOUNTAIN. THIS | | ARE REQUIRED PER TABLE 403.1 FBC-2001 | | AND CAN NOT BE DELETED. | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
17 |
Status |
N |
Date |
2006-02-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-02-11 |
Time |
11:10 |
Rev Time |
0.60 |
Received By |
kstevens |
Date |
2006-02-11 |
Time |
11:10 |
Sent To |
|
|
Notes |
2006-02-11 00:00:00 | REVISION - NO PLUMBING PLANS SUBMITTED |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
16 |
Status |
P |
Date |
2005-09-29 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-09-29 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-09-29 |
Time |
14:30 |
Sent To |
|
|
Notes |
2005-09-29 00:00:00 | REV DATED 8-3,8-10, |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
15 |
Status |
P |
Date |
2005-08-20 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-08-20 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-08-20 |
Time |
13:44 |
Sent To |
B |
|
Notes |
2005-08-20 00:00:00 | REVISIONS OK PES |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
14 |
Status |
F |
Date |
2005-08-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-08-02 |
Time |
09:19 |
Rev Time |
3.81 |
Received By |
kstevens |
Date |
2005-08-02 |
Time |
09:19 |
Sent To |
M |
|
Notes |
2005-08-02 00:00:00 | REVISION DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1. SHT P1.02 REVISION #6 NOT FOUND, AND | | OTHER REVISIONS TO SHEET NOT CLOUDED OR | | NUMBERED. (CONDENSATE DRAIN LINES, STORM | | DRAIN LINES, BACKWATER VALVE ECT.). - | | NUMBER 44, BACKFLOW PREVENTION REQUIRED | | ON NEW IRRIGATION LINE. SECTION 608.13.2 | | 2. SHT P1.09 REVISION #1 NOT FOUND. | | REVISIONS REQUIRED FOR ALL RISER | | DIAGRAMS CHANGED ON THIS REVISION. - | | CONDENSATE AND STORM LINES DELETED FROM | | PLANS. - WILL THESE BE SHOWN ON ANOTHER | | SHEET? PLEASE CLARIFY SECTION 104.2.1. | | 3. SHT P1.09 INDICATE HOW THE LISTING | | FOR FIRE RATINGS FOR SEPARATION WALLS | | WILL BE MAINTAINED WITH THE LAUNDRY | | BOXES IN TENANT SEPARATION WALLS BETWEEN | | UNITS B1A.1/B1A.1, B1.2/B1.2, & | | B1C.2/B1C.2. ALSO UNIT B2.2 AND THE EXIT | | CORRIDOR. | | 4. SHT P1.09 UNABLE TO READ INFORMATION | | AT W/H-A/C CLOSETS AT UNITS B1C.2 AND | | B1D. SECTION 104.2.1. | | 5. SHT P1.10 REVISION #2 NOT FOUND AND | | MANY REVISIONS NOT CLOUDED OR NUMBERED. | | SECTION 104.2.1. | | 5. P3.01C NEW SHEET WITH REVISIONS? | | PLEASE CLARIFY. WHAT IS THE INTENT OF | | THIS SHEET? THIS SHEET DOES NOT REFLECT | | THE INFORMATION OF THE PREVIOUS SHEET | | SHOWING THE SANITARY COLLECTION SYSTEM. | | ONLY SHOWS ONE CHANGE CLOUDED AND | | NUMBERED. ALL RISER DESIGNATIONS ARE | | CHANGED AND AS SUCH WILL HAVE TO BE | | CHANGED ON ALL SHEETS FOR ALL FLOORS TO | | REFLECT THIS CHANGE. BUILDING DRAIN | | LAYOUT IS CHANGED WITHOUT CLOUDS OR | | REVISION NUMBERS. IF THIS REVISION IS A | | REVISION TO SHEET P3.01, (WHICH IT | | APPEARS TO BE), SIMPLY REVISE SHE P3.01. | | A NEW SHEET NUMBER IS NOT REQUIRED AND | | ONLY CAUSES CONFUSION BECAUSE TWO | | COLLECTION ISOMETRICS WILL BE SHOWN FOR | | ONE SYSTEM. SECTION 104.2.1. | | 6. SHT P3.01C STUDOR VENT WILL REQUIRE A | | RELEIF VENT PER SECTION 917.3.2. - | | STUDOR VENTS AT THE LIFT STATIONS ARE | | NOT APPROVED. - INFORMATION ON P3.01C | | WILL DELETE RISER "A" IF THIS SHEET | | SUPERCEEDS SHEET P3.01. PLEASE CLARIFY. | | SECTION 104.2.1. | | 7. REVISIONS 5, 6, & 7 ARE NOT FOUND. | | PLEASE CLARIFY. SECTION 104.2.1. MANY | | CHANGES FOUND ON NEW SHEET ARE NOT | | CLOUDED OR NUMBERED/. NO REVIEW OF SHEET | | UNTILL ALL CHANGES TO SHEET FOLLOWING | | THE SHEET SIGNED/SEALED 12-17-04 ARE | | CLOUDED AND NUMBERED. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
13 |
Status |
P |
Date |
2005-07-12 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-07-12 |
Time |
14:49 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-07-12 |
Time |
14:49 |
Sent To |
|
|
Notes |
2005-07-12 00:00:00 | PRODUCT APPROVAL ONLY PRO SET SYSTEM | | FIRE STOPPING. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
12 |
Status |
F |
Date |
2005-06-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-06-13 |
Time |
10:41 |
Rev Time |
14.33 |
Received By |
kstevens |
Date |
2005-06-13 |
Time |
10:41 |
Sent To |
|
|
Notes |
2005-06-13 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 FUEL GAS | | FBC-2001 CHAPTER 1 | | | | | | 1. SHT P1.01 REVISION 7 NOT FOUND. | | PLEASE CLOUD AND NUMBER EACH REVISION. | | SECTION 104.2.1. | | 2. SHT P1.02 REVISION 6 NOT FOUND. | | PLEASE CLOUD AND NUMBER EACH REVISION. | | SECTION 104.2.1. | | 3. SHT P1.03 FOLLOWING TO NOT MEET CODE: | | A. TUB NOT VENTED UNIT B1.1 BATH #2 | | B. INDICATE WHERE S/14 RISER CONNECTS | | TO THE BLDG. DRAIN. SECTION 104.2.1. | | C. UNIT STUDIO "S2" TOILET IS NOT | | VENTED. LAV SHOULD VENT THE BATHROOM | | FIXTURES AND KITCHEN SINK/WASH MACHINE | | SHALL DISCHARGE DOWNSTREAM OF THE WET | | VENT. SECTIONS 901.2.1 & 909.1. | | D. 2" PIPE FEEDING THE HOSE BIBB? | | PLEASE CLARIFY. SECTION 104.2.1. | | E. UNIT A2 UNABLE TO READ RISER | | DESIGNATION OVER A/C UNIT. SECTION | | 104.2.1. | | F. REVISIONS 2, 3, & 4 NOT FOUND. | | PLEASE CLOUD AND NUMBER EACH REVISION. | | SECTION 104.2.1. | | 4. SHT P1.04 REVISION #1 NOT FOUND. | | PLEASE CLOUD AND NUMBER ALL REVISIONS. | | SECTION 104.2.1. - SEE UNIT "B2" LAV | | CONNECTION TO BRANCH LINE NOT DIRECTING | | WASTE IN DIRECTIONS OF FLOW. SECTION | | 706.3. (COL. LINE W.K) | | 5. SHT P1.05 REVISION #1 NOT FOUND. | | PLEASE CLOUD AND NUMBER ALL REVISIONS. | | SECTION 104.2.1. - TWO NUMBER 46 RISERS | | BUT NO NUMBER 47. PLEASE CLARIFY. | | 6. SHT P1.06 REVISION #1 NOT FOUND. | | PLEASE CLOUD AND NUMBER ALL REVISIONS. | | SECTION 104.2.1. - SHEET INDICATES | | "TYPICAL FLOOR PLAN - PLUMBING" FOR | | WHICH FLOORS? SECTION 104.2.1. - TWO #46 | | SANT. RISERS AND NO #47 SANT. RISER. | | PLEASE CLARIFY. | | 7. SHT P1.07 REVISION #1 NOT FOUND. | | PLEASE CLOUD AND NUMBER ALL REVISIONS. | | SECTION 104.2.1. - TWO #46 RISERS AND NO | | #47 RISER FOUND. PLEASE CLARIFY. | | 8. SHT P1.08 REVISION #1 NOT FOUND. | | PLEASE CLOUD AND NUMBER ALL REVISIONS. | | SECTION 104.2.1. - SHOW ALL RISER | | DESIGNATION NUMBERS. SECTION 104.2.1. | | 9. SHT P1.09 REVISION #1 NOT FOUND. | | PLEASE CLOUD AND NUMBER ALL REVISIONS. | | SECTION 104.2.1. - TWO NUMBER 46 SANT. | | RISERS AND NO #47 RISER FOUND. PLEASE | | CLARIFY. | | 10. SHT P1.10 THE FOLLOWING SANT. RISERS | | SHOW UP ON THIS SHEET, BUT WERE NOT | | NOTED ON THE PREVIOUS SHEETS FROM THE | | GROUND FLOOR UP. S/16, S/33, S/51, & | | S/63 PLEASE CLARIFY.-INDICATE THE | | LOCATION OF VTR FOR SANT. RISER 74. - | | RISER S/63 DOES NOT REFLECT THE ROOF | | PLAN. THE FLOOR DRAIN IS NOT SHOWN ON | | RISER. PLEASE CORRELATE RISER WITH FLOOR | | PLAN. - FLOOR DRAIN BY S/64 NOT PIPED TO | | ANY SANT. RISER. PLEASE CLARIFY. SECTION | | 104.2.1. | | 11. SHT P3.01 SANT. RISER S/8 OFFSET | | VENT REQUIRED. SECTION 915 - VENT STACK | | SHALL CONNECT AT OR BELOW THE THE LOWEST | | HORIZONTAL BRANCH. SECTION 903.4. - | | STACK VENT SHALL RUN UNDIMINISHED IN | | SIZE AND AS DIRECTLY AS POSSIBLE FROM | | THE BUILDING DRAIN THROUGH TO THE OPEN | | AIR. SECTION 903.1. | | 12 SHT P3.01 SANT. RISER S/1 A VENT | | STACK IS REQUIRED PER SECTION 903.2 - | | VENT STACK CONNECTION APPEARS TO BE A | | HORIZONTAL DRY VENT. THIS IS NOT | | APPROVED PER SECTIONS 905.3 & 905.4. | | 13. SHT P3.01 SANT. RISER S/6-W/7, THE | | FITTING DOWNSTREAM OF STACKS PICKING UP | | THE W/M & TUB DOES NOT DIRECT THE WASTE | | IN THE DIRECTION OF FLOW AS REQUIRED IN | | SECTION 706.3. | | 14. SHT P3.01A SANT. RISER S/76 | | INDICATES FLOORS 3 THRU 7 TWICE, BUT NO | | FLOOR 8. PLEASE CLARIFY. SECTION | | 104.2.1. | | 15. SHT P301A SANT. RISER S/19 DOES NOT | | REFLECT THE FLOOR PLAN. SHOWER MISSING | | FROM RISER AND TUB SHOWN IN DIFFERENT | | LOCATION. PLEASE CORRELATE FLOOR PLAN & | | RISER DIAGRAM. SECTION 104.2.1. | | 16. SHT P3.01A FLOOR DRAIN NEAR SANT. | | RISER S/69 REQUIRES A RELIEF VENT FOR | | THE AIR ADMITTANCE VALVE. SECTION | | 917.3.2. | | 17. SHT P3.01C AIR ADMITTANCE VALVE NOT | | APPROVED FOR LIFT STATION. ONLY APPROVED | | FOR NEGATIVE PRESSURE. PLEASE SUBMIT | | MANUFACTURE SPECIFICATION AND | | INSTALLATION SHEETS FOR VALVE INDICATING | | APPROVAL FOR INSTALLATION FOR THIS TYPE | | OF APPLICATION.SECTION 303.2 | | 18. SHT P3.01C FLOOR SINK FOR INDIRECT | | WASTE FROM 3" FSP THE AIR ADMITTANCE | | VALVE REQUIRES A RELIEF VENT. SECTION | | 917.3.2. | | 19. SHT P3.01C BUILDING DRAIN LINES DO | | NOT REFLECT THE FLOOR PLAN DOWNSTREAM OF | | RISERS I, J, & K. ALSO THE PIPE SIZING | | FOR I, J, & K DO NOT REFLECT WHAT IS | | STATED IN KEY NOTES #10 WHICH IS 4". | | 20. SHT P3.01C INDICATE IF FLOOR DRAIN | | PIPING TO THE LIFT STATION. IT APPEARS | | TO BE ON THE FLOOR ABOVE. PLEASE | | CLARIFY. SECTION 104.2.1. - ALSO ALL | | THREE FLOOR DRAINS TO LIFT STATIONS ARE | | NOT VENTED. SECTION 901.2.1. | | 21. SHT P3.02 SANT. RISER S/30, TUB NOT | | VENTED AT THE BASE OF SANT. RISER. | | SECTION 901.2.1. | | 22. SHT P3.02 TOILET ROOM DOWNSTREAM OF | | RISERS 2/37-S/67 DOES NOT REFLECT THE | | FLOOR PLAN. LAV NOT SHOWN. CORRELATE | | FLOOR PLAN AND RISER. SECTION 104.2.1. - | | REVISIONS 2 & 3 NOT FOUND. PLEASE CLOUD | | AND NUMBER EACH REVISION. | | 23. SHT P3.02 SANT. RISER DIAGRAM, A | | VENT STACK IS REQUIRED, AND AN OFFSET | | VENT IS REQUIRED. SECTIONS 903.3 & 915. | | 24. SHT P3.02A BATHROOM DOWNSTREAM OF | | RISER S/53, THE LAV IS MISSING ON THE | | RISER DIAGRAM. THE LAV SHOULD VENT THE | | BATHROOM GROUP AND THE KITCHEN SHOULD | | CONNECT TO THE LINE WITH THE WASH | | MACHINE AND SHOULD NOT DRAIN THROUGHT | | THE HORIZONTAL WET VENT OF THE BATHROOM | | FIXTURES. SECTION 909.1. - THIS IS A NEW | | SHEET AND SHOWS 4 DIFFERENT REVISIONS. | | PLEASE CLARIFY. | | 25. SHT P3.03 SANT. RISER S/44 DOES NOT | | REFLECT THE FLOOR PLAN. WASH MACHINE IS | | MISSING. SECTION 104.2.1. - REVISIONS 2 | | & 3 NOT FOUND. PLEASE CLOUD AND NUMBER | | EACH REVISION. SECTION 104.2.1. | | 26. SHT P3.04 SANT. RISER S/58 DOES NOT | | REFLECT THE FLOOR PLAN, AND THE FIXTURES | | ARE MISLABLED AS LAVS. KITCHEN SINK | | MISSING 2ND FLOOR. SECTION 104.2.1. - | | REVISIONS 2 & 3 NOT FOUND. PLEASE CLOUD | | AND NUMBER EACH REVISION. SECTION | | 104.2.1. | | 27. SHT P3.09 REVISIONS 5 & 6 NOT FOUND. | | PLEASE CLOUD AND NUMBER EACH REVISIONS. | | SECTION 104.2.1. | | 28. SHT P3.11 NATURAL GAS ISOMETRIC: | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2001 | | FUEL GAS CODE. | | 28. SHT P3.12 REVISIONS 2 & 3 NOT FOUND. | | PLEASE CLOUD AND NUMBER ALL REVISIONS. | | SECTION 104.2.1. | | 29. SHT P4.01 REVISION #2 NOT FOUND. | | PLEASE CLOUD AND NUMBER EACH REVISIONS. | | SECTION 104.2.1. | | 30. THE FOLLOWING SHEETS WERE APPROVED | | AND ONE HAS BEEN ATTACHED TO FILE SET. | | P.1.11, P2.01. [2.02, P2.03, P2.04, | | P3.01B, P3.05, P3.06, & P4.02. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
11 |
Status |
F |
Date |
2005-01-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-01-13 |
Time |
07:40 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2005-01-13 |
Time |
07:40 |
Sent To |
|
|
Notes |
2005-01-13 00:00:00 | DENIED | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | | | SUBMITTAL DENIED - EACH SHEET SHALL BE | | SIGNED, SEALED, AND DATED. ALL TITLE | | BLOCK INFORMATION TO BE ON EACH SHEET | | 61G15-23.002(1)(2) & FS 471.025 | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
10 |
Status |
P |
Date |
2005-01-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-01-11 |
Time |
15:22 |
Rev Time |
1.75 |
Received By |
kstevens |
Date |
2005-01-11 |
Time |
15:22 |
Sent To |
|
|
Notes |
2005-01-11 00:00:00 | REVISION OK - SHTS P1.01, P1.02, P3.09, | | & P3.10 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
9 |
Status |
F |
Date |
2004-12-15 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-12-15 |
Time |
07:26 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-12-15 |
Time |
07:26 |
Sent To |
|
|
Notes |
2004-12-15 00:00:00 | DENIED | | | | SEE COMMENTS FROM REVISION REVIEW DATED | | 12-13-4ATTACHED TO THIS SHEET. | | KSTEVENS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
8 |
Status |
F |
Date |
2004-12-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-12-13 |
Time |
18:22 |
Rev Time |
2.00 |
Received By |
kstevens |
Date |
2004-12-13 |
Time |
18:22 |
Sent To |
|
|
Notes |
2004-12-13 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1) SHT P1.02 SANITARY LINE FROM HUB | | DRAINS FOR FIRE LINE DRAINS SHOWS | | DIRECTION OF FLOW IN TWO DIRECTIONS NEAR | | THE AIR INTAKE WELL. PLEASE CLARIFY. | | SECTION 104.2.1 | | 2) SHT P3.09 ACCUMULATED SQUARE FOOTAGE | | IN THE STORM SYSTEM IS NOT CORRECT. SEE | | AREA BY REVISION #3, 12" (20205) PLUS | | FORCED MAIN FROM BELOW (6900) SHOULD BE | | TOTAL OF 27105 SQ.FT., BUT PLANS SHOW | | 39385 SQ.FT. SECTION 104.2.1 | | 3) SHT P3.09 PIPING AT RISER "C" SHOWS | | 10" PIPE (9650), AND 8" (7960). 8" | | SHOULD READ (5380) AND 10" SHOULD READ | | (12980). SECTION 104.2.1. | | 4) SHT P3.10 FROM PREVIOUS COMMENT, | | PLEASE CORRECT THE SQ.FT. FROM RISER "C" | | TO READ 12,980 SQ.FT. AND 22,440 | | UPSTREAM OF THE STORM DRAIN LIFT | | STATION. SECTOPM 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
7 |
Status |
F |
Date |
2004-12-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-12-02 |
Time |
11:16 |
Rev Time |
1.75 |
Received By |
kstevens |
Date |
2004-12-02 |
Time |
11:16 |
Sent To |
|
|
Notes |
2004-12-02 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1) SHT P1.01 COL. LINE P.4/P.B INDICATES | | THE PIPING TO (14) IS DELETED, BUT THE | | RISER IS STILL SHOWN. PLEASE CLARIFY. | | SECTION 104.2.1. | | 2) STORM DRAIN LINE #9 BY ELEVATOR #1 BY | | COL. LINE P.4. PLEASE INDICATE WHERE | | THIS BRANCH LINE TIES INTO THE STACK. | | SECTION 104.2.1. | | 3) REVISIONS ON THE SANITARY SYSTEM | | SHOWN ON SHT P1.01 SHALL BE REFLECTED ON | | THE SANITARY RISER DIAGRAM. PLEASE | | CORRELATE THE RISER DIAGRAM WITH THE | | FLOOR PLAN. SECTION 104.2.1. | | 4) SHT P1.01 SANITARY LINE BY THE | | CLEANOUT NEAR COL.LINE P.5. PLEASE | | INDICATE WHERE THIS LINE TIES INTO. | | SECTION 104.2.1. | | 5) SHT P3.10 THE STORM RISER DIAGRAM | | DOES NOT REFLECT THE LAYOUT ON SHEET | | P1.01. THE 3" PAD IS SHOWN CONNECTING | | BETWEEN THE TRENCH DRAINS ON THE LAYOUT | | SHEET, BUT DOWN STREAM OF BOTH TRENCH | | DRAINS ON THE STORMDRAIN ISOMETRIC. | | PLEASE CORRELATE THE RISER WITH THE | | LAYOUT. SECTION 104.2.1 | | | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
P |
Date |
2004-06-24 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-11-24 |
Time |
16:14 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2004-06-24 |
Time |
15:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2004-06-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-06-17 |
Time |
16:11 |
Rev Time |
2.00 |
Received By |
kstevens |
Date |
2004-06-17 |
Time |
16:11 |
Sent To |
|
|
Notes |
2004-06-17 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 1 | | FHA-98 DESIGN MANUAL | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1) FROM PREVIOUS REVIEW: SHTS A.51 THRU | | A.66 CALCULATIONS FOR 20GA METAL BACKING | | ALL SHEETS SHALL BE SIGNED, SEALED AND | | DATED. ALL INFORMATION FOR TITLE BLOCK | | IS REQUIRED ON ALL SHEETS. ONLY ONE SET | | HAS SEAL/SIGNATURE/DATE OTHER SETS ARE | | COPIES. FAC 61G15-23.002(1)(2) - FS 471. | | 025 - ALSO ABOVE MENTIONED SHEETS | | STILL SHOW 20 GA METAL BACKING WHILE THE | | CALCULATIONS INDICATE 16GA METAL BACKING | | CORRELATE PLANS WITH CALCULATIONS. ALSO | | SEE DETAILS ON SHT A.67. SEC 104.2.1 | | 2) SHT A.63 CLEAR FLOOR SPACE FOR LAV IS | | NOT SHOWN. ALSO LAV SHALL BE CENTERED ON | | THE 48" SIDE OF THE 30"X48" CLEAR FLOOR | | SPACE. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2004-04-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-04-10 |
Time |
18:38 |
Rev Time |
5.50 |
Received By |
kstevens |
Date |
2004-04-10 |
Time |
18:38 |
Sent To |
|
|
Notes |
2004-04-10 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 FUEL GAS | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | FBC-2001 BUILDING | | FHA-AMEND. 98 DESIGN MANUAL | | | | A) COMMENTS FROM FIRST TWO REVIEWS NOT | | ADDRESSED SUFFICIENTLY. | | 1) SHTS A.11 & A.12 ALL PUBLIC & COMMON | | USE TOILET ROOMS SHALL COMPLY WITH SEC. | | 11-4.22 AND ALL SUBSECTIONS. CLEAR FLOOR | | SPACE IS NOT SHOWN FOR WATER CLOSET AND | | LAV IN ACCESSIBLE STALLS IN MENS AND | | WOMENS TOILET ROOMS. (019) | | 2) PLEASE SUBMIT CALCULATIONS FOR MINI- | | MUM FIXTURE FACILITIES PER TABLE 403.1. | | MORE INFORMATION REQUIRED. INDICATE ROOM | | NUMBER, ROOM USAGE, AND SQUARE FEET FOR | | EACH ROOM. (EXAMPLE - MAIL ROOM - MGR | | ROOM ECT) | | 3) INDICATE LOCATION OF SCUPPER DETAIL | | THAT SHOWS HEIGHT AND WIDTH. DETAIL ON | | SHEET A.45 DOES NOT SHOW HEIGHT OR THE | | WIDTH. | | 4) SHTS A.51 THRU A.66 UNIT NOTES #7, | | CALCULATIONS FOR 20GA METAL BACKING. | | RESPONSE "SEE CHM CALCULATIONS" WHERE | | ARE THE CHM CALCULATIONS LOCATED? ALSO | | WHAT ARE CHM CALCULATIONS? IS THERE A | | SHEET WITH THE ABBREVIATIONS SHOWN? | | 5) SHT A.11 BAR SINK SHALL COMPLY WITH | | 11-4.24 AND ALL SUBSECTIONS. PROVIDE A | | DETAIL. - RESPONSE STATES SHOWN ON SHEET | | A.68 - A.68 SHOWS OUTSIDE ELEVATIONS. | | NO BAR SINK ELEVATIONS SHOWN. (3B) | | 6) SCUPPER DETAIL DOES NOT SHOW HEIGHT | | OR WIDTH. THIS INFORMATION IS REQUIRED | | TO DETERMINE THE SIZE OF THE SCUPPER. | | (4B) | | 7) SHTS A.51 THRU A.66 SHOW CLEAR FLOOR | | SPACE FOR ALL ACCESSIBLE FIXTURES PER | | FHA DESIGN MANUAL PAGE 7.43 - ALL FIX- | | TURES OF ALL UNITS DO NOT SHOW CLEAR | | FLOOR SPACE. | | 8) IT APPEARS THAT SOME OF THESE COMM- | | ENTS HAVE BEEN REJECTED AT LEAST 3 TIMES | | AND A 4 TIMES THE FEE MAY BE ACCESSED. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2004-02-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-02-10 |
Time |
17:13 |
Rev Time |
10.00 |
Received By |
kstevens |
Date |
2004-02-10 |
Time |
17:12 |
Sent To |
|
|
Notes |
2004-02-10 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 FUEL GAS | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | FHA-AMEND. 98 DESIGN MANUAL | | | | A) COMMENTS FROM THE FIRST AND SECOND | | REVIEW HAVE NOT BEEN ADDRESSED AND NO | | COMMENT RESPONSE NOTED. COMMENT NUMBERS | | FROM FIRST AND SECOND REVEIW WILL REMAIN | | THE SAME FOR CLAIRTY. | | 2) PLEASE SUBMIT CALCULATIONS FOR MINI- | | MUM FIXTURE FACILITIES PER TABLE 403.1 | | FOR THE BUSINESS/COMMON AREAS GROUND | | FLOOR LEVEL. INCLUDE MGR, ASST. MGR, | | CONFERENCE ROOMS, HEALTH CLUB, FIRE CON- | | TROL, SEC. DESK, VALET, MAIL ROOM, MAIN | | LOBBY, CARD ROOM, FITNESS CENTER, BAR, | | PANTRY, ECT. (NO RESPONSE NOTED) | | 3) SUBMIT CALCULATIONS FOR PRIMARY AND | | SECONDARY ROOF DRAINS. SHOW 1/2 AREA OF | | ALL VERTICAL WALLS INCLUDING PARAPETS & | | AREA OF ROOFS THAT DRAIN FROM ABOVE. IN- | | DICATE HOW THE INTERNAL ROOF AREAS, | | (WITHOUT SCUPPERS), ADD TO SCUPPER SIZE | | OF ADJACENT AREAS. SECTIONS 1106 & 1107 | | AND ALL SUBSECTIONS. (NO RESPONSE NOTED) | | 6) SHEETS A.51 THRU A.61 LAV. ELEVATIONS | | MAXIMUM 34" TO TOP. FHA DESIGN MANUAL | | PAGE 7.52. (NO RESPONSE NOTED - STILL AT | | 36" TO TOP). | | 8) SHTS A.51 THRU A.66 UNIT PLAN NOTES | | #7, SUBMIT CALCULATIONS FOR 20GA BACKING | | SHOW COMPLIANCE WITH SECTIONS 11-4.26.3, | | 11-4.26.3(1), 11-4.26.3(2), 11-4.26.3(3) | | AND 11-4.26.34). (NO RESPONSE NOTED) | | 9) SHEETS A.51 THRU A.66 SHOW OPENING | | SIZE FOR ALL WATER CLOSETS. MINIMUM 33". | | (18" OFF WALL WHERE LOCATED NEXT TO ONE, | | AND MINIMUM OF 18" OFF FIXTURE) - THE | | FOLLOWING UNITS DO NOT SHOW SIZE OPENING | | SHT A.52 UNIT A2, SHT A.53 UNIT A5 W/C | | TO BE 1'6" OFF WALL NOT 1'7", SHT A.56 | | UNIT B1B, SHT A.57 UNIT B1E, SHT A.59 | | UNIT B1E, SHT A.61 UNIT B3, SHT A.62 | | UNIT B5, AND SHT A.63 UNIT C1. | | 10) SHT P1.01 SHOW PIPE SIZES AND CLEAN- | | OUT LOCTIONS. TABLE 710.1(1) & SECTIONS | | 708.3, 708.3.1, AND 708.3.5. (NO RESPON- | | SE NOTED. THE PIPE SIZE CAN BE LOCATED | | ON THE SANT. RISER DIAGRAM, BUT THE C/O | | LOCATIONS SHALL BE SHOWN PER CODE). | | *************FROM 2ND REVIEW************ | | 3B) SHT A.11 BAR SINK SHALL COMPLY WITH | | 11.4.24 AND ALL SUBSECTIONS. PROVIDE A | | DETAIL. (RESPONSE STATES SHOWN ON SHEET | | A.68, BUT NO SHEET A.68 SUBMITTED). | | 5B) SHEETS A.51 THRU A.66 SHOW CLEAR | | FLOOR SPACE FOR ALL ACCESSIBLE FIXTURES | | PER FHA DESIGN MANUAL PAGE 7.43. (RES- | | PONSE NOTED BUT ON SHT A.51 THE CLEAR | | FLOOR SPACE FOR THE LAV AND W/C ARE NOT | | ON PLANS. AND FOR SHTS A.52 THRU A.66 | | THE CLEAR FLOOR SPACE FOR THE WATER | | CLOSETS ARE NOT ON PLANS). | | 37B) 4 TIMES THE FEE FOR PLAN REVIEW | | SHALL NOW BE CHARGED PER FLORIDA STATUTE | | 533.80(2)(B) - $133,200.00 IS DUE. | | ******NEW COMMENTS****** | | 1C) SHT A.55 UNITS B1 & B1.1 INDICATES | | TYPE 'B' BUT BATH #2 IS A TYPE 'A' LAY- | | OUT. PLEASE CLAIRFY. | | 2C) SHTS A.56, A.57, A.58, A.59, A.60, | | A.61, A.62, AND A.63 ALL THESE UNITS | | SHOW TYPE 'B', BUT IN EACH SPACE BOTH | | BATHROOMS SHOW CLEAR FLOOR SPACE. WHICH | | BATHROOM WILL BE ADAPTABLE? PLEASE | | CLAIRFY. | | 3C) SHTS A.51 THRU A.66 ALL UNITS THAT | | HAVE PARALLEL APPROACH TO LAVS, THE LAVS | | SHALL BE CENTERED ON THE 48" DIMENSION. | | 4C) ORIGINAL PERMIT APPLICATION SHALL BE | | SUBMITTED TO ISSUE PERMIT. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-11-18 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-11-18 |
Time |
09:30 |
Rev Time |
23.00 |
Received By |
kstevens |
Date |
2003-11-14 |
Time |
18:54 |
Sent To |
|
|
Notes |
2003-11-18 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 FUEL GAS | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | FHA-98 DESIGN MANUAL | | FLORIDA STATUTES | | FLORIDA ADMINISTRATIVE CODE | | CITY WPB CODE | | | | A) MANY COMMENTS FROM THE FIRST REVIEW | | WERE NOT ADDRESSED AND NO COMMENT RES- | | PONSE NOTED. COMMENT NUMBERS FROM FIRST | | REVIEW WILL BE SHOWN FOR CLAIRITY. | | 1) SHTS A.11 & A.12, ALL PUBLIC & COMMON | | USE TOILET ROOMS SHALL COMPLY WITH SEC. | | 11-4.22 AND ALL SUBSECTIONS. (CLEAR | | FLOOR SPACE, HEIGHTS, GRAB BARS, ECT.). | | 2) PLEASE SUBMIT CALCULATIONS FOR MINI- | | MUM FIXTURE FACILITIES PER TABLE 403.1 | | FOR THE BUSINESS/COMMON AREAS GROUND | | FLOOR LEVEL, INCLUDE MGR, ASST. MGR, | | CONFERENCE ROOMS, HEALTH CLUB, FIRE | | CONTROL, SEC. DESK, VALET, MAIL ROOM, | | MAIN LOBBY, CARD ROOM, FITNESS CENTER, | | BAR, PANTRY, ECT. | | 3) SUBMIT CALCULATIONS FOR PRIMARY AND | | SECONDARY ROOF DRAINS. SHOW 1/2 AREA OF | | ALL VERTICAL WALLS INCLUDING PARAPETS | | AND AREA OF ROOFS THAT DRAIN FROM ABOVE | | ON TO ROOF ADDED TO SQUARE FOOTAGE OF | | ROOF. SHOW HOW EACH AREA WILL BE AFFECT- | | ED BY VERTICAL WALLS AND ROOF DRAINING | | FROM ABOVE, INDICATE HOW THE INTERNAL | | ROOF AEAS, (WITHOUT SCUPPERS), ADD TO | | SCUPPER SIZE OF ADJACENT AREAS. SECTIONS | | 1106 & 1107 AND ALL SUBSECTIONS. | | 4) SHT A.09, INDICATE LOCATION OF SECON- | | DARY DRAINS FOR THE DECK AREA AROUND THE | | POOL, AND DECK AREAS BELOW THE POOL DECK | | AREA. | | 6) SHTS A.51 THRU A.66, LAV ELEVATIONS | | MAXIMUM 34" TO TOP. FHA DESIGN MANUAL | | PAGE 7.52. | | 7) SHTS A.51 THRU A.66, SPECIFICATION | | "A" OR "B" SHALL BE NOTED ON PLANS FOR | | BATHROOMS PER FHA DESIGN MANUAL PAGE | | 7.35. | | 8) SHTS A.51 THRU A.66, UNIT PLAN NOTES: | | #7, SUBMIT CALCULATIONS FOR 20GA METAL | | BACKING. SHOW COMPLIANCE WITH SECTIONS | | AA-4.26.3, 11-4.26.3(1), 11-4.26.3(2), | | 11-4.26.3(3), & 11-4.26.3(4). | | 9) SHTS A.51 THRU A.66 SHOW OPENING SIZE | | FOR ALL WATER CLOSETS. MINIMUM SIZE 33". | | (18" OFF WALL WHERE LOCATED NEXT TO ONE, | | AND MINIMUM OF 18" OFF FIXTURE). | | 10) SHT P1.01 SHOW PIPE SIZES AND CLEAN- | | OUT LOCATIONS. TABLE 710.1(1) & SECTIONS | | 708.3, 708.3.1, 708.3.3, 708.3.5. | | 23) SEPARATE GAS PERMIT REQUIRED. THE | | FOLLOWING INFORMATION IS REQUIRED FOR A | | PERMIT. | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2001 | | FUEL GAS CODE. - NOT ALL SECTIONS INDIC- | | ATE THE LENGTHS. | | B. SHOW TYPE OF PIPING MATERIAL BEING | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | NUMBER OF CORRUGATED STAINLESS STEEL | | TUBING FOR EACH PIPE SIZE BEING USED. | | C. TYPE OF GAS, (LP OR NATURAL) | | E. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES (A)(3). - RECHECK | | DISTANCE. | | F. SUBMIT CALCULATIONS FOR COMBUSTION | | AIR (IF APPLICABLE) PER FBC-2001 FUEL | | GAS CODE SECTION 304. | | G. INDICATE THE DELIVERY PRESSURE (PSI) | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | I. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND THE | | FBC-2001 FUEL GAS CODE SEC 402.2 | | J. CLEARLY SHOW THE LOCATION AND CAP- | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | OR ASME), THE DISTANCE OF THE TANK FROM | | THE BUILDING AND ADJACENT PROPERTY LINES | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | INGS, AND THE LOCATION OF ANY BUILDING | | OPENINGS BELOW THE RELIEF VALVE OF THE | | TANK PER NFPA 58, TABLE 3-2.2.2. | | K. CLEARLY INDICATE ON THE PLAN IF THE | | LP TANK IS ABOVE OR BELOW GROUND, AND | | SHOW REQUIRED PROTECTION OF THE TANK AND | | APPURTENANCES PER NFPA 58. IF THE TANK | | IS BELOW GROUND THE CONTAINER SHALL BE | | SECURILY ANCHORED PER NFPA 58 SECTION | | 3-2.2.7(H). | | *********WHEN RESUBMITTING PLANS******** | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | **************************************** | | NEW COMMENTS | | 1B) SHT A.12 WALLS IN MEN'S & WOMEN'S | | TOILET ROOMS APPEAR TO BE IN TURNING | | CIRCLE AND IN HDCP STALLS. PLEASE REMOVE | | 2B) SUBMIT A DETAIL FOR ACCESSIBLE | | TOILET ROOMS PER 11-4.16, 11-4.19, AND | | 11-4.22 AND ALL SUBSECTIONS. | | 3B) SHT A.11 BAR SINK SHALL COMPLY WITH | | 11-4.24 AND ALL SUBSECTIONS. PROVIDE A | | DETAIL. | | 4B) SHT A.45 OVERFLOW SCUPPER DETAIL. | | SCUPPER SHALL BE PLACED IN WALLS OR | | PARAPETS WITH THE INLET FLOW LINE NOT | | LESS THAN 2 INCHES ABOVE THE ROOF SUR- | | FACE, EXCLUDING SUMPS, OR MORE THAN 4 | | INCHES ABOVE THE ROOF SURFACE AND SHALL | | BE LOCATED AS CLOSE AS PRACTICAL TO REQ- | | UIRED VERTICAL LEADERS. | | 5B) SHTS A.51 THRU A.66 SHOW CLEAR FLOOR | | SPACE FOR ALL ACCESSIBLE FIXTURES PER | | FHA DESIGN MANUAL PAGE 7.43 | | 6B) SHTS A.51 THRU A.66 UNIT PLAN NOTES: | | #6 STATE 1996 FHA - UPDATE TO READ AMEND | | ED 1998 FHA. | | 7B) SHT P1.01 KEY NOTES: #8 & STORM | | DRAIN, 3" FIRE STAND PIPE DRAIN NOT APP- | | ROVED TO STORM. DRAIN SHALL CONNECT TO | | SANITARY VIA INDIRECT WASTE. CITY CODE | | SECTION 90-233(A). | | 8B) SHTS P1.01 & P1.02 MORE INFORMATION | | REQUIRED FOR PAD RISER. SEE #'S 14 & 37 | | KEY NOTES. | | 9B) SHT P1.02 FLOOR DRAINS FOR FIRE AND | | DOMESTIC PUMP ROOMS SHALL CONNECT TO | | SANITARY, NOT STORM. CITY CODE 90-233(A) | | 10B) 61G15-23.002(1) SIGNATURE REQUIRED | | ON SEAL. PER FBPE INITALS ARE NOT TO BE | | ACCEPTED. THE SIGNATURE THAT WAS SIGNED | | ON THE ENGINEERS LICENSE SHALL BE RE- | | QUIRED ON EACH SHEET. | | 11B) SHT P1.04 RISER DIAGRAM DOES NOT | | REFLECT THE FLOOR PLAN FOR UNIT 1. | | SECTION 104.2.1 | | 12B) SUBMIT RISER DIAGRAMS FOR RELIEF | | VALVE DISCHARGE LINE (P&T) FOR W/HEATERS | | THE DISCHARGE LINE FOR RELIEF VALVE | | SHALL NOT HAVE ANY TRAPPED SECTIONS AND | | SHALL HAVE A VISIBLE AIR GAP OR AIR GAP | | FITTING IN THE SAME ROOM AS THE WATER | | HEATER. SEC 504.7.1 | | 13B) SHT P3.01 12" @ 3085 DFU'S AND 12" | | @ 3419 DFU'S NOT APPROVED PER TABLE | | 710.1(1). | | 14B) SHT P3.03 RISER S/19, 3" REQUIRED | | TO SHOWER. TABLE 909.3 | | 15B) BACKFLOW PROTECTION REQUIRED FOR | | TRASH CHUTE RING. SECTION 608.13 SUBMIT | | DETAIL. | | 16B) SHT P3.05 KEY NOTES: #22, CLAIRFY | | 15TH FLOOR. #17 NOT FOUND. (2) # 19'S | | 17B) SHT P3.05 SUBMIT CALCULATIONS FOR | | WATER PRESSURE AT BOTTOM OF DROPS FOR | | UNITS TO DETERMINE OF A PRESSURE REGULA- | | TOR IS REQUIRED. | | 18B) SHT P3.06 FILTER FOR ICE MACHINE | | SHALL COMPLY WITH NSF STANDARD FOR WATER | | FILTERS. SUBMIT MANUFACTURE SPECIFICAT- | | ION SHEETS. SECTION 303.4 | | 19B) SHT P3.06 WATER HAMMER ARRESTORS | | REQUIRED AND ICE MACHINE AND DISHWASHER. | | SECTION 604.9 | | 20B) SHT P3.09 STORM DRAIN COLLECTION | | ISOMETRIC, DOWNSTREAM OF RWL'S 24 & 25 | | SHOWS 6"(5280 SF). MINIMUM 8" PIPE REQD. | | 21B) SHT P3.09 STORM DRAIN COLLECTION | | ISO., DOWNSTREAM OF (A) SHOWS 6" (2840 | | SF) THEN SHOWS 4" PLEASE REVISE. 704.2. | | 22B) SHT P3.09 STORM DRAIN COLLECTION | | ISO., PLANTER DRAINS SHOW 40SF PLUS 200 | | SF, BUT ONLY ADDS UP TO 80SF. AND AFTER | | 6" DD (3300SF) PLUS (240SF) SHOWS (3380 | | SF) BUT SHOULD READ (3540SF) PLEASE RE- | | VISE. - INDICATE SF FOR FORCE MAIN FROM | | BELOW. - ALSO DOWNSTREAM OF PD (1040SF) | | SHOWS (900 SF) REVISE. | | 23B) PROVIDE INFORMATION FOR FSP DRAIN. | | WHAT TYPE OF DRAIN IS THIS AND WHAT DOES | | IT DRAIN? | | 24B) SHT P3.10 PROVIDE MANUF. SPECC. | | SHEETS ON STORM DRAIN LIFT STATION. | | 25B) SHT P3.10 FIRE STAND PIPE DRAIN | | SHALL NOT DRAIN TO STORM. CONNECT TO | | SANITARY SYSTTEM. | | 26B) SHT P3.11 PROVIDE CUT PIECE MEAS- | | URMENTS FROM METER TO FIRST GAS RISER & | | MEASURMENTS FOR ALL CUT PIECES IN BOILER | | ROOM. | | 27B) SHT P3.11 GAS ISOMETRIC, INDICATE | | WHY GAS LINE TO POOL EQUIPMENT ROOM IS | | SLEEVED. PIPING SHALL NOT BE INSTALLED | | IN SOLID FLOOR SLABS. SECTION 404.6 | | 28B) SHT P3.11 NFPA-54 HAS NOT BEEN | | ADOPTED. SIZE PIPE PER FBC-2001 FUEL GAS | | DELETE REFERENCE. | | 29B) SHT P3.12 CONDENSATE COLLECTION ISO | | MINIMUM 2" PIPE UNDERGROUND. SECTION | | 710.3 | | 30B) SHT P3.12 COND. COLLECTION ISO., A | | RELIEF VENT IS REQUIRED AS CONDENSATE | | EXITS THE BLDG. | | 31B) SHTS P1.03, THRUP1.09, & P2.01 | | UNIT "A", RISER S/70 RISER NOT FOUND AND | | RISER S/18 DOES NOT REFLECT THE FLOOR | | PLAN. SHT P3.04 | | 32B) SHT P3.03 RISER S/19 TABLE 909.3 | | 3" REQUIRED TO SHOWER. | | 33B) SHTS P1.03 THRU P1.09 & P2.01 UNIT | | "A" MOD, RISER S/71 NOT FOUND AND RISER | | S/53 DOES NOT REFLECT THE FLOOR PLAN. | | SHT P3.04. | | 34B) SHT P3.04 RISER S/59 DOES NOT RE- | | FLECT THE FLOOR PLAN. | | 35B) SHT P3.04 RISER S/62 DOES NOT RE- | | FLECT THE FLOOR PLAN. | | 36B) SUBMIT MANUF. SPEC. SHEET FOR SIM- | | PLEX AND TRIPLES PUMP SYSTEMS. | | 37B) SEE ATTACHED SHEET CONCERNING | | FS 533.80(2)(B) DESIGN PROFESSIONAL DOC- | | UMENTS. | | *********WHEN RESUBMITTING PLANS******** | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BUILDING PLAN REVIEW | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-06-06 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-06-05 |
Time |
18:08 |
Rev Time |
11.00 |
Received By |
rbrown |
Date |
2003-06-04 |
Time |
12:21 |
Sent To |
|
|
Notes |
2003-06-05 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 FUEL GAS | | FBC-2001 CHAPTER 11 | | FBC-2001 BUILDING | | FHA-AMEND. 98 DESIGN MANUAL | | | | 1) SHTS A.11 & A.12, ALL PUBLIC & COMMON | | USE TOILET ROOMS SHALL COMPLY WITH SEC. | | 11-4.22 AND ALL SUB SECTIONS. (5' TURN- | | ING CIRCLE, CLEAR FLOOR SPACE ECT) SEC. | | 11-4.1.3(11). (4 TOILET ROOMS #019) | | 2) PLEASE SUBMIT CALCULATIONS FOR MINI- | | MUM FIXTURE FACILITIES PER TABLE 403.1 | | FOR THE BUSINESS/COMMON AREAS GROUND | | FLOOR LEVEL. | | 3) PLEASE SUBMIT CALCULATIONS FOR PRIM- | | ARY AND SECONDARY ROOF DRAINS. PLEASE | | SHOW 1/2 AREA OF ALL VERTICAL WALLS, AND | | SHOW AREA OF ROOFS THAT DRAIN TO ROOF | | DRAINS FROM ABOVE, AND SHOW HOW EACH | | AREA WILL BE AFFECTED BY WALLS AND UPPER | | ROOFS. INDICATE HOW THE INTERNAL ROOF | | AREAS, (WITHOUT SCUPPERS), ADD TO SCUPP- | | ER SIZE OF ADJACENT AREAS. SEC. 1106 & | | 1107 AND ALL SUBSECTIONS. | | 4) SHT A.09, PLEASE INDICATE LOCATION OF | | SECONDARY DRAINS FOR DECK AREA AROUND | | THE POOL, AND DECK AREAS BELOW THE POOL | | DECK AREA. | | 5) SHT A.09 PLEASE INDICATE WHERE THE | | AREA FOR THE COOLING TOWERS WILL DRAIN | | AND IF 1/2 AREA OF ALL VERTICAL WALLS | | WILL BE ADDED TO THAT AREA. | | 6) SHTS A.51 THRU A.66, LAV ELEVATIONS | | MAXIMUM 34" TO TOP. FHA DESIGN MANUAL | | PAGE 7.52. | | 7) SHTS A.51 THRU A.66, SPECIFICATION | | "A" OR "B" SHALL BE NOTED ON PLANS FOR | | BATHROOMS PER FHA DESIGN MANUAL PAGE | | 7.35. | | 8) SHTS A.51 THRU A.66, UNIT PLAN NOTES: | | #7, SUBMIT CALCULATIONS FOR 20GA METAL | | BACKING. SHOW COMPLIANCE WITH SECTIONS | | 11-4.26.3, 11-4.26.3(1), 11-4.26.3(2), | | 11-4.26.3(3), & 11-4.26.3(4). SEE AT- | | TACHED SHEET. | | 9) SHTS A.51 THRU A.66 SHOW OPENING | | SIZE FOR ALL WATER CLOSETS. MINIMUM SIZE | | 33". (18" OFF WALL WHERE LOCATED NEXT TO | | ONE, AND MINIMUM 18" OFF FIXTURE.) | | 10) SHT P1.01 PLEASE SHOW PIPE SIZES AND | | CLEANOUT LOCATIONS. TABLE 710.1(1) AND | | SECTION 708.3, 708.3.1, 708.3.3, 708.3.5 | | 11) PLEASE SUBMIT SETS OF PLANS WITH ALL | | SHEETS INCLUDED. THE FOLLOWING SHEETS | | REFERENCED ON SHT P1.01 WERE NOT FOUND. | | P3.01, P3.03, P3.05, P3.06, P3.07, P3.08 | | P3.09, P3.10, & P3.11. | | 12) SHT P1.01 PLEASE SHOW PIPE SIZES AND | | C/0'S REQUIRED BY SEC 104.2.1 AND SEC | | 708.3. | | 13) SHT P1.07 FLOOR DRAINS REQUIRED IN | | TOILET ROOMS FOR POOL. SEC 424.1.6.1.3 | | 14) SHT P2.01 UNIT A-2, WASH MACHINE | | SHALL NOT DRAIN THROUGH WET VENT FOR | | BATHROOM FIXTURES. SEC 909.1 | | 15) SHT P205 NO PIPING LAYOUT IN STUDIO | | UNITS 1, 2, & 3. PLEASE CLAIRFY. | | 16) SUBMIT A SANITARY HORIZONTAL ISOMET- | | RIC. PLEASE SHOW ALL PIPE SIZES, SLOP OF | | PIPE, INDICATE WHERE RISERS TIE IN, FIX- | | TURE UNITS AS THEY ACCUMULATE, AND CLEAN | | OUTS. SEC 104.2.1 | | 17) SUBMIT A STORM WATER ISOMETRIC. | | PLEASE SHOW ALL PIPE SIZES, SLOP OF PIPE | | INDICATE WHERE RISERS TIE IN, SQUARE | | FOOTAGE AS IT ACCUMULATES, AND TERMIN- | | ATION. SEC 104.2.1 | | 18) SUBMIT A WATER AND SANT. RISER DIA- | | GRAM FOR FOR TYPICAL UNITS AND COMMON | | AREAS. SHOW ALL PIPE SIZES, LOCATION OF | | WATER HAMMER ARRESTORS, ECT. SEC 104.2.1 | | 19) SHT P4.01 SEPARATE PERMIT/PLANS RE- | | QUIRED FOR POOL/POOL EQUIPMENT ROOM. | | PLANS TO BE REVIEWED AND STAMPED BY THE | | HEALTH DEPT. PRIOR TO SUBMITTING TO CITY | | FOR REVIEW. | | 20) SHT 4.02 PLUMBING GENERAL NOTES #16, | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | AT THE ICE MAKER, AND DISHWASHER ALSO, | | SEC 604.9. W.H.A'S SHALL BE LOCATED NEAR | | THE FIXTURE, IN AN "EFFECTIVE RANGE" PER | | PDI-WH 201 AND MANUF. INSTALL. INSTRUCT. | | NOT AT TOP OF DROP, IN THE CEILING. | | 21) SUBMIT A CONDENSATE ISOMETRIC FOR | | REVIEW. PLEASE SHOW ALL PIPES SIZES AND | | INDICATE TERMINATION POINT. CONDENSATE | | SHALL RUN SEPARATELY OUT OF BLDG. AND | | TIE INTO STORM LINE OR CATCH BASIN. A | | RELIEF VENT IS REQUIRED AS CONDENSATE | | LINE EXITS THE BLDG. | | 22) SHT P4.01 DOMESTIC BOILER SYSTEM DE- | | TAIL, SAFETY PAN ARE REQUIRED FOR THE | | HEATERS AND THE STORAGE TANK. SEC 504.8 | | PLEASE SHOW HOW PAN DRAIN LINES WILL BE | | RUN. SUPPLY RISER DIAGRAM IF REQUIRED, | | AND INDICATE SIZE OF PIPING, & MATERIAL | | FOR PIPING. SEC 104.2.1 | | 23) SEPARATE GAS PERMIT REQUIRED. THE | | FOLLOWING INFORMATION IS REQUIRED FOR | | PERMIT. | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2001 | | FUEL GAS CODE. | | B. SHOW TYPE OF PIPING MATERIAL BEING | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | NUMBER OF CORRUGATED STAINLESS STEEL | | TUBING FOR EACH PIPE SIZE BEING USED. | | PER FBC-2001 FUEL GAS CODE SEC 402.3 | | C. TYPE OF GAS, (LP OR NATURAL) SEC402.3 | | D. BTU LOAD OF EACH APPLIANCE AND THE | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | THE FBC-2001 FUEL GAS CODE SECS. 401.8 | | THRU 402.5.2 AND TABLES 402(1) THRU | | 402(34). | | E. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES (A)(3). | | F. SUBMIT CALCULATIONS FOR COMBUSTION | | AIR (IF APPLICABLE) PER FBC-2001 FUEL | | GAS CODE SECTION 304. | | G. INDICATE THE DELIVERY PRESSURE (PSI) | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | H. SUBMIT A DETAIL SHOWING THE TYPE, | | LOCATION, SIZE AND TERMINATION OF THE | | GAS VENTS PER FBC-2001 FUEL GAS CODE | | SECS. 502 THRU 506. | | I. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND THE | | FBC-2001 FUEL GAS CODE SEC 402.2 | | J. CLEARLY SHOW THE LOCATION AND CAP- | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | OR ASME), THE DISTANCE OF THE TANK FROM | | THE BUILDING AND ADJACENT PROPERTY LINES | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | INGS, AND THE LOCATION OF ANY BUILDING | | OPENINGS BELOW THE RELIEF VALVE OF THE | | TANK PER NFPA 58, TABLE 3-2.2.2. | | K. CLEARLY INDICATE ON THE PLAN IF THE | | LP TANK IS ABOVE OR BELOW GROUND, AND | | SHOW REQUIRED PROTECTION OF THE TANK AND | | APPURTENANCES PER NFPA 58. IF THE TANK | | IS BELOW GROUND THE CONTAINER SHALL BE | | SECURILY ANCHORED PER NFPA 58 SECTION | | 3-2.2.7(H). | | *********WHEN RESUBMITTING PLANS******** | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
11 |
Status |
P |
Date |
2006-07-19 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2006-07-19 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2006-07-19 |
Time |
12:11 |
Sent To |
|
|
Notes |
2006-07-19 00:00:00 | LANDSCAPE CHANGES APPROVED |
|
|
Review Stop |
Z |
ZONING |
Rev No |
10 |
Status |
F |
Date |
2006-06-26 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2006-06-26 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2006-06-26 |
Time |
12:07 |
Sent To |
|
|
Notes |
2006-06-26 00:00:00 | LANDSCAPE COMMENTS: | | 1. TREES ALONG GARDENIA STREET AND FERN | | STREET SHALL BE REPLACED BY HIGH RISE | | LIVE OAKS. ONLY THE 3 TREES CLOSER TO | | THE BUILDING ALONG FERN STREET CAN BE | | REPLACED BY DAHOON HOLLY. | | 2. BY LANDSCAPE PLANNER COMMENT, PLEASE | | CHANGE PLANTING DIAGRAM TO SHOWED ON | | WWW.WPB.ORG/SUGGESTEDTREELIST.PDF, WHEN | | POSSIBLE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
9 |
Status |
P |
Date |
2006-06-14 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2006-06-14 |
Time |
13:21 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2006-06-07 |
Time |
13:21 |
Sent To |
|
|
Notes |
2006-06-14 00:00:00 | REVISIONS ARE APPROVED. THE FOLLOWING | | COMMENTS ARE FOR CLARIFICATION AND | | CONSISTENCY ON DRAWINGS. | | 1. SHEET A.04 SHOWS AN 8 FEET SIDEWALK | | ALONG THE NORHT SIDE OF SAPODILLA, | | HOWEVER SITE PLAN ON SHEET A.01 SHOWS 9 | | FEET 1 INCH. PLEASE VERIFY DIMENSION AND | | MODIFY SHEET A.04 TO REFLECT APPROVED | | SITE PLAN. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
8 |
Status |
F |
Date |
2006-05-08 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2006-05-08 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2006-05-08 |
Time |
15:45 |
Sent To |
|
|
Notes |
2006-05-08 00:00:00 | 8 INCHES OF LANDSCAPE IS NOT BIG ENOUGH | | TO GROW PLANTS. PLEASE EXTEND THE | | SIDEWALK TO THE FACE OF THE BUILDING. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
7 |
Status |
F |
Date |
2006-02-27 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2006-02-27 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2006-02-27 |
Time |
09:15 |
Sent To |
|
|
Notes |
2006-02-27 00:00:00 | PLEASE CONFINE PAVING TO PROPERTY. DO | | NOT EXTEND TO CURB. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
6 |
Status |
F |
Date |
2006-02-14 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2006-02-14 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2006-02-14 |
Time |
09:09 |
Sent To |
|
|
Notes |
2006-02-17 00:00:00 | SUBMITTAL FOR ROOFTOP CHAIN LINK FENCE: | | | 2006-02-14 00:00:00 | PLEASE DESIGN SCREENING AS AN INTEGRAL | | PART OF THE BUILDING AS PER | | SEC.94-114(F)(10)OF THE ZONING CODE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
F |
Date |
2005-08-18 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2005-08-18 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2005-08-18 |
Time |
15:06 |
Sent To |
|
|
Notes |
2005-08-18 00:00:00 | COMMENTS INCLUDED ON THE APPROVAL | | 06/24/2004 HAVE NOT BEEN ADDRESSED.IN | | ADDITION, THE PROPOSED CHANGES ON THE | | LANDSCAPE ALONG SAPODILLA ARE AFFECTING | | THE MINIMUM 8 FEET CLEAR SIDEWALK | | REQUIRED. PLEASE MODIFY THE PROPOSED | | LANDSCAPE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2004-06-24 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-06-24 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-06-24 |
Time |
08:41 |
Sent To |
|
|
Notes |
2004-06-24 00:00:00 | PROVISO: | | 1. PLEASE UPDATE DRAWING A-01 TO REFLECT | | CHANGES ON THE SIDEWALK DIMENSION.THE | | NORTH SIDE OF SAPODILLA HAS TO BE 8FT | | AS PRESENTED ON THE GROUND FLOOR | | DRAWINGS. | | 2. PLEASE USE LIVE OAK ON FERN STREET | | AND GARDENIA STREET & MEET WITH ALAN | | BARRATTA FROM THE PLANNING DEPT AT | | 659-8031 FOR LANDSCAPE PLANTING | | INSTRUCTIONS. | | 3. CONFIRM THAT SIGN IS REMOVED FROM | | PLANTER IN THE NORTH PLAZA. | | ANY QUESTION, PLEASE CALL 659-8031, | | ANA MARIE |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2004-04-01 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-06-23 |
Time |
22:03 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2004-04-01 |
Time |
16:24 |
Sent To |
|
|
Notes |
2004-04-01 00:00:00 | ACCORDING WITH ARTICLE IV SECTION 94-113 | | (B)(7) THE SIDEWALK SHOULD BE MINIMUM 8' | | WIDE. THE SIDEWALK ON THE NORTH SIDE OF | | SAPODILLA IS 6'7". | | SIGN FACES ON NORTH PLAZA PLANTER ARE | | NOT INCLUDED. SIGNS MUST BE MOUNTED ON | | BUILDING, NOT PLANTER. | | THE TRIM SHOULD BE CONSISTENT ALL AROUND | | THE BUILDING. THE TRIM IS NOT SHOWN ON | | THE NORTH ELEVATION (SHEET A23). | | REGARDING LIGHTS ON SAPODILLA,IF REMOVED | | SHALL BE RETURNED TO CURRENT LOCATION BY | | CONTRACTOR AFTER THE JOB IS FINISHED. | | NEW LIGHTS ON FERN AND GARDENIA SHALL | | MATCH THE EXISTING ONES IN SAPODILLA. | | SHADE TREES ON FERN SHALL MATCH EXISTING | | SHADE TREES EAST OF SAPODILLA IN FRONT | | OF CITY PLACE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2003-11-04 |
|
|
Cont ID |
|
Sent By |
agiannio |
Date |
2003-11-04 |
Time |
15:38 |
Rev Time |
6.00 |
Received By |
agiannio |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-11-04 00:00:00 | IN RELATION WITH THE PUBLIC OPEN SPACES | | WE HAVE THE FOLLOWING COMMENTS: | | 1. PURSUANT TO ARTICLE IV SECTION 94-115 | | (E)(5), THE SOUTH PLAZA MUST BE AT SIDE | | WALK GRADE. | | 2. PURSUANT TO ARTICLE IV SECTION 94-115 | | (E)(1)PUBLIC OPEN SPACE SHALL CONFORM | | TO THE OPEN SPACE DESIGN GUIDELINES. CON | | SIDERING THE INTENTIONS OF THE PUBLIC OP | | EN SPACE GUIDELINES, THE SOUTH PLAZA SHO | | ULD BE MORE INVITING FOR THE GENERAL PUB | | LIC-THE LANDSCAPE DESIGN IN CONJUCTION W | | ITH THE GRADE ACTS AS A BARRIER. | | 3.THE DRAWINGS SHOULD DEPICT DETAILS OF | | THE BENCHES OR SEATING AREA AS WELL AS T | | HE LOCATION OF THE DRINKING FOUNTAINS AS | | REQUIRED BY THE PUBLIC OPEN SPACE DESIG | | N GUIDELINES. | | 4. PLEASE CONFIRM THAT THE PROPOSED STRE | | ET LIGH LOCATION AND TREE SPECIES AND LO | | CATIONS CONFORM TO THE EXISTING STREETSC | | APE ON SAPODILLA AVENUE. | | | | IN RELATION WITH THE BUILDING PLACEMENT | | WE HAVE THE FOLLOWING COMMENTS: | | 1. ACCORDING WITH ARTICLE IV SECTION 94- | | 113 (B)(7) THE SIDEWALK SHOULD BE MINIMU | | M 8' WIDE. THE SIDE WALK ON GARDENIA STR | | EET IS 5'9" (AS DEPICTED IN DRAWING A-01 | | ). | | | | IN RELATION WITH THE ARCHITECTURAL DESIG | | N GUIDELINES WE HAVE THE FOLLOWING COMME | | NTS: | | 1. TO FURTHER DIFFERENTIATE THE "CAP" FR | | OM THE "MIDDLE" OF THE BUILDING, BALCONY | | RAILINGS ON THE EIGHT FLOOR SHOULD BE T | | HE FULL METAL DESIGN CONSISTENT WITH THE | | SMALLER BALCONIES. | | 2. BALCONIES ON SOUTH AND NORTH ELEVATIO | | N SHOULD BE ARCHED CONSISTENT WITH THE E | | AST ELEVATION. | | 3.THE BALCONIES ON THE 7TH FLOOR SHOULD | | ALL HAVE THE SAME PROPORTION OPENING (US | | E THE TALLER VERSION). | | 4.THE TRIM SHOULD BE CONSISTENT ALL AROU | | ND THE BUILDING. IT STOPS OVER THE NORTH | | PLAZA (SHEET A-21A). | | 5. THE BRACKETS UNDER THE BALCONIES NEED | | TO BE CREDIBLE SUPPORTS; PLEASE REVISE | | DETAIL. | | | | IN RELATION WITH THE ROOF TERRACE WE HAV | | E THE FOLLOWING COMMENTS: | | 1.THE OVERALL ROOF TERRACE HAS TO BE 15% | | LANDSCAPED. | | 2. THE PERCENTAGE OF COVERED AREA SHOULD | | NOT EXCEED 30% OF THE GROSS ROOF AREA. | | 3.PLEASE PROVIDE A TABLE WITH THE PERCEN | | TAGE OF LANDSCAPED AREA AND THE PERCENTA | | GE OF COVERED AREA. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-03-29 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-17 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-05-20 00:00:00 | DENIED, NEED TO MEET ANTHEA G ABOUT | | THE PROCESS |
|
|