Plan Review Stops For Permit 03042700 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-07-18 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-07-18 |
Time |
11:28 |
Rev Time |
1.50 |
Received By |
sthyng |
Date |
2003-07-18 |
Time |
11:28 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-06-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-07-17 |
Time |
15:33 |
Rev Time |
3.00 |
Received By |
sthyng |
Date |
2003-06-11 |
Time |
15:54 |
Sent To |
|
|
Notes |
2003-06-11 00:00:00 | ******CORRECTIONS******** | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | FILED WITH THE CLERK OF COURT BEFORE | | A PERMIT CAN BE ISSUED. | | | | 2.)DESIGN INFORMATION IS REQUIRED TO | | BE ON THE PLAN, FBC 1606.1.7, NOT ON | | WIND LOAD CERTIFICATION FORM. | | | | 3.)BEDROOMS ARE REQUIRED TO HAVE | | EMERGENCY EGRESS FBC 1005.4.A 24 S/H | | WINDOW DOES NOT MEET THE HEIGHT | | REQUIREMENT. | | | | 4.)SAFETY GLASS REQUIRED FOR THE | | WINDOWS AT THE TUB AND SHOWER,FBC2405.2. | | NOTE ON FLOOR PLAN. | | | | 5.)SPECIFY MATERIAL AND ATTACHMENTS | | FOR PORCH CEILING. | | | | 6.)WALL SECTON SHOWS R3 INSULATION | | ON WALLS, ENERGY CALC SHOWS 4.2. | | | | 7.)UPLIFT SPECIFIED FOR ATTACHMENTS | | EXCEED PRODUCT LIMITATIONS, SEE | | ATTACHED.REVISE; DO NOT INCLUDE | | STRESS INCREASE FOR STEEL; USE 2003 | | CATALOGS. | | | | 8.)ADDITIONAL FEES REQUIRED. | | | | 9.)SUBMIT TWO COPIES OF PRODUCT | | APPROVALS FOR THE DOUBLE FRENCH DOORS | | AND THE WINDOW MULLIONS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-07-14 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-09 |
Time |
16:26 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-07-14 |
Time |
09:43 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-05-14 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-11 |
Time |
11:08 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-05-14 |
Time |
09:58 |
Sent To |
P |
|
Notes |
2003-05-14 00:00:00 | UNSAT | | ~~~~~ | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | PLEASE PROVIDE THE FOLLOWING | | INFORMATION,MAKE ANY NECESSARY CHANGES | | ON THE PLANS AND RESUBMIT FOR REVIEW. | | | | 1} PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW EQUIPMENT BEING INSTALLED. | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | 2} PLEASE SHOW THE GROUNDING ELECTRODE | | SYSTEM IN COMPLIANCE WITH 250-50(A,B & | | C) | | | | 3} THE CALCULATION FOR THE A/C SYSTEM ON | | THE PANEL SCHEDULE AND THE LOAD CALC'S | | DO NOT CORRELATE. | | | | 4} THE SMALL APPLIANCE CIRCUITS MUST BE | | CALCULATED @ 1500 VA.EA PER 220-16(A). | | | | 5} THERE IS ONLY ONE GENERAL LIGHTING | | CIRCUIT ON THE PANEL SCHEDULE.THERE | | MUST BE A MINIMUM OF THREE @ 15AMPS. | | | | 6} PLEASE LIST THE REQ'D BATH(S) | | CIRCUIT(S). PER 210-11-C-3 | | MUST BE 20A AND #12AWG. | | | | 7} SMOKE DETECTORS ARE REQUIRED | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | PER 8-1.4.2,NFPA-72. | | | | 8} PLEASE LIST THE REQ'D ARC | | FAULT PROTECTED CIRCUITS ON PANEL | | SCHEDULE OR NOTE ON PLANS FOR BRANCH | | CIRCUIT PROTECTION. PER 210-12 | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-10-09 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-09 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-09 |
Time |
16:25 |
Sent To |
E |
|
Notes |
2003-10-09 00:00:00 | TO BT DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-07-11 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-11 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-11 |
Time |
11:08 |
Sent To |
E |
|
Notes |
2003-07-11 00:00:00 | BT DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-04-29 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-29 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-29 |
Time |
14:45 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2003-10-16 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-10-16 |
Time |
08:01 |
Rev Time |
0.20 |
Received By |
pkrauss |
Date |
2003-10-16 |
Time |
07:58 |
Sent To |
|
|
Notes |
2003-10-16 00:00:00 | SEE COMMENTS DATED 7-18-03 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-10-16 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-07-18 |
Time |
15:27 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-07-18 |
Time |
15:21 |
Sent To |
|
|
Notes |
2003-10-16 00:00:00 | PROVISO: | | PLEASE NOTE, REVISION TO THE 2001 | | FBC(M) 601.4, EFFECTIVE JUNE 30,2003: | | | | PLEASE SIZE RETURN AIR AS TO THE | | BEDROOM AREAS AS FOLLOWS: | | | | BALANCED AIR RETURN - RETURN/TRANSFER | | SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL | | AREA (SQ INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM ITS SERVING & THE | | DOOR HAVING AN UNRESTRICTED 1" UNDERCUT. | | | | ALL SUPPLY AIR INTO THE MASTER SUITE | | SHALL BE INCLUDED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-06-04 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-07-18 |
Time |
11:29 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-06-04 |
Time |
08:04 |
Sent To |
B |
|
Notes |
2003-06-04 00:00:00 | MECHANICAL PERMIT 03042711 | | PLANS APPROVED ON 5-24-03 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-07-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-07-17 |
Time |
15:32 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2003-07-17 |
Time |
15:32 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-05-17 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-07-14 |
Time |
10:22 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2003-05-17 |
Time |
09:36 |
Sent To |
M |
|
Notes |
2003-05-17 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | CODE REQUIREMENTS. KITCHEN SINK NOT | | VENTED. - SHOWER & TUB IS NOT VENTED, | | (SEE RED LINE CORRECTIONS), PLEASE SHOW | | ALL PIPE SIZES. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-04-30 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-29 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
E |
|
Notes |
|
|