Plan Review Stops For Permit 03042682 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2003-08-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2003-08-26 |
Time |
10:53 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2003-08-26 |
Time |
10:53 |
Sent To |
PC |
|
Notes |
2003-08-26 00:00:00 | SUBMITTAL CHECKLIST: | | 1-SITE SPECIFIC INFORMATION FOR MULLIONS | | NEED THE DESIGN CRITERIA. ENGINEER TO | | SEE SECTION 1606.1.7FBC 2001 FOR | | ALL INFORMATION REQUIRED TO BE ON ALL | | DRAWINGS. | | 2-ARCHITECT REVISED DETAIL 12/A6 BUT | | NEED TO REVISE THE ELEVATION HEIGHTS | | GIVEN FOR THE RAKE BEAM. REVISE ROOF | | FRAMING PLAN AS REQUIRED SHOWING | | CORRECT HEIGHTS. | | | | **NOTE: NEED THIS INFORMATION REQUESTED | | ON PROVISO DATED 8-4-03: | | A)SOIL TEST REPORT. | | B)ROOF TILE PRODUCT APPROVAL. | | C)ENTRY DOORS WITH UPDATED DADE COUNTY | | PRODUCT APPROVAL. | | D)COMPLETE GARAGE DOORS PRODUCT APPROVAL | | WITH LEGIBLE DRAWINGS. | | E)SITE SPECIFIC ENGINEERING INFORMATION | | FOR WINDOW MULLIONS. | | F)GLASS BLOCK PRODUCT APPROVAL WITH | | LEGIBLE DRAWINGS. | | G)FLOOD ZONE AO: NEED THE ELEVATION | | CERTIFICATE PRIOR TO C.O. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2003-08-07 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-21 |
Time |
12:57 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2003-08-07 |
Time |
09:19 |
Sent To |
PC |
|
Notes |
2003-08-07 00:00:00 | SUBMITTAL CHECKLIST: | | 1-DETAIL 12/A6 KEYED FOR FAMILY ROOMAT | | GABLE END DOESN'T APPLY. NEED TO | | PROVIDE RAKE BEAM BECAUSE OF VAULTED | | CEILING AT THIS AREA TO COMPLY WITH | | SECTION 2117.1.2 FBC 2001. | | 2-REVISE ANCHOR SPECIFIED ON DETAIL | | 10/A5. IF USING SIMPSON ANCHORS, THEN, | | NEED TO SEE THE SIMPSON HIGH WIND- | | RESISTANT CONSTRUCTION CATALOGUE, | | WHICH IS THE ONLY ONE REVISED TO | | COMPLY WITH SECTION 1609.4.3 FBC 2001. | | **NOTE: ONLY THE ANCHORS HIGHLIGHTED | | ORANGE ARE THE ONES WHO WERE REVISED | | TO NO INCLUDE THE STEEL STRESS | | INCREASE. | | 3-CONTRACTOR TO PROVIDE ALL INFORMATION | | REQUESTED ON PROVISO DATED 8-4-03 | | TO AVOID ANY DELAYS OR CONFLICTS | | DURING CONSTRUCTION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2003-08-04 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-06 |
Time |
15:30 |
Rev Time |
2.50 |
Received By |
jgomez |
Date |
2003-08-04 |
Time |
14:25 |
Sent To |
PC |
|
Notes |
2003-08-04 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-PROVIDE SOIL TEST REPORT. | | PRELIMINARY SOIL REPORT REQUIRES | | ADDITIONAL TESTING DONE TO ASSURE | | PROPER SOIL BEARING CAPACITY. | | 2-PROVIDE PRODUCT APPROVAL FOR: | | A)ROOF TILE. | | B)ENTRY DOORS WITH UPDATED DADE COUNTY | | REPORT WITH DADE COUNTY LOGO AT | | BOTTOM LEFT OF REPORT AND LEGIBLE | | DWGS WITH DADE COUNTY RENEWAL STAMP. | | C)COMPLETE GARAGE DOOR REPORT WITH | | LEGIBLE DRAWINGS. | | D)SITE SPECIFIC ENGINEERING NEED SITE | | SPECIFIC INFORMATION. INFORMATION | | SUBMITTED FOR MULLIONS IS GENERIC. | | CLEARLY SPECIFY ON DRAWINGS ALL THE | | SPECIFIC COMPONENTS TO BE USED ON | | THIS PROJECT. MULLION SIZE, ANCHORS, | | DESIGN PRESSURES ETC. | | ALSO, JOB SITE LOCATION, ETC. | | E)NEED PRODUCT APPROVAL FOR STRUCTURAL | | HEADER ABOVE SLIDING GLASS DOORS. | | SEE PLANS FOR SIZE. | | F)GLASS BLOCK LEGIBLE APPROVED DRAWINGS. | | | | 4-REVISE ANCHOR SPECIFIED ON DET. 10/A5. | | SEE SIMPSON HIGH WIND-RESISTANT CONST. | | CATALOGUE, WHICH IS THE ONLY SIMPSON | | CATALOGUE REVISED TO COMPLY WITH SEC. | | 1609.4.3 FBC 2001. (ALSO, CHECK SIZE | | OF BOLTS). | | 5-REVISE GABLE END CONSTRUCTION DETAIL | | @ FAMILY ROOM TO COMPLY WITH SECTION | | 2117.1.2 FBC 2001. | | 6-CLARIFY DETAILS 2/A5 AND 6/A5 TO MATCH | | CONDITIONS AT KEYED AREA. SECTION | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | 7-FLOOD ZONE AO: NEED TO PROVIDE THE | | ELEVATION CERTIFICATE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2003-07-22 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-31 |
Time |
16:53 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2003-07-22 |
Time |
12:48 |
Sent To |
PC |
|
Notes |
2003-07-22 00:00:00 | THIRD CHECKLIST: | | 1-ENERGY CALCULATIONS WERE NOT PROPERLY | | REVISED: ENERGY CALCULATIONS DON'T | | MATCH ORIENTATION OF THE HOUSE. ENERGY | | CALCULATIONS ARE TYPICALLY DONE TO | | WORST CASE SCENARIO WHEN BUILDING A | | MODEL OVER AND OVER TO COVER ALL | | ORIENTATIONS. THESE ENERGY CALCS ARE | | NOT DONE FOR WORST CASE, NEITHER ARE | | ARE THEY SITE SPECIFIC. THESE IS THE | | THIRD TIME THE SAME COMMENT WAS RAISED | | BUT IT HAS NOT BEING CORRECTED. | | 2-PROVIDE SOIL TEST REPORT. | | 3-PROVIDE PRODUCT APPROVAL FOR: | | A)ROOF TILE (IT'S A SEPARATE PERMIT, BUT | | STILL IS PART OF SUBMITTAL PACKAGE). | | B)ENTRY DOORS WITH UPDATED DADE COUNTY | | REPORT WITH DADE COUNTY LOGO AT BOTTOM | | LEFT OF REPORT AND WITH LEGIBLE DWGS | | WITH DADE COUNTY RENEWAL STAMP. | | C)COMPLETE GARAGE DOOR REPORT WITH | | LEGIBLE DRAWINGS. | | D)SITE SPECIFIC ENGINEERING NEED SITE | | SPECIFIC INFORMATION. INFORMATION | | SUBMITTED FOR MULLIONS IS GENERIC. | | CLEARLY SPECIFY ON DRAWINGS ALL THE | | SPECIFIC COMPONENTS TO BE USED ON | | THIS PROJECT. MULLION SIZE, ANCHORS, | | DESIGN PRESSURES, ETC. | | ALSO, INDICATE ADDRESS OF PROJECT AND | | PROVIDE COMPLETE SITE SPECIFIC FORM AS | | DONE FOR OTHER SITE SPECIFIC WINDOWS. | | E)NEED PRODUCT APPROVAL FOR STRUCTURAL | | HEADER ABOVE SLIDING GLASS DOORS. SEE | | PLANS FOR SIZES. | | F)PROVIDE GLASS BLOCK PRODUCT APPROVAL | | WITH LEGIBLE DRAWINGS. | | | | 4-REVISE BOLT SIZE SPECIFIED FOR ANCHOR | | SHOWN ON DETAIL 10/A5. SEE SIMPSON | | HIGH WIND-RESISTANT CONSTRUCTION | | CATALOGUE WHICH IS THE ONLY SIMPSON | | CATALOGUE REVISED TO MEET SECTION | | 1609.4.3 FBC 2001. | | 5-REVISE GABLE END CONSTRUCTION DETAIL | | AT FAMILY ROOM AREA TO COMPLY WITH | | SEC. 2117.1.2 FBC 2001. | | **ALSO, CLARIFY DETAILS 2/A5 AND 6/A5 | | BECAUSE THEY DON'T APPLY TO THIS AREA. | | REVISE AS REQUIRED. SEC. 104.2.1.2 | | CITY AMENDMENTS TO FBC 2001. | | 6-OWES $774.32 FOR WESTERN EXPANSION | | FEES AND RADON FEES. | | ADDITIONALY, RE-SUBMITTAL FEES WILL | | BE ADDED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. | | | | **NOTE: | | PLEASE INSERT ANY REVISED DRAWINGS INTO | | THE SETS AND REMOVE ALL DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-07-10 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-16 |
Time |
10:48 |
Rev Time |
3.00 |
Received By |
jgomez |
Date |
2003-07-10 |
Time |
11:07 |
Sent To |
PC |
|
Notes |
2003-07-10 00:00:00 | SECOND CHECKLIST: | | 1-ENERGY CALCULATIONS WERE NOT REVISED: | | A)A/C AREA DOESN'T MATCH A/C AREA SHOWN | | ON PLANS. | | B)ENERGY CALCULATIONS NEED TO BE DONE | | WORST CASE SCENARIO FOR A PARTICULAR | | MODEL OR SITE SPECIFIC. ENERGY CALCS. | | SUBMITTED ARE NEITHER OF THE ABOVE. | | REVISE AS REQUIRED. | | C)REVISE UNDER ATTIC AREA TO COMPLY WITH | | SEC. 602.1ABC.1.2 CHAPTER 13 FBC 2001. | | | | 2-PROVIDE SOIL TEST REPORT. | | 3-PROVIDE PRODUCT APPROVAL FOR: | | A)ROOF TILE. (IT'S SEPARATE PERMIT | | BECAUSE SUBCONTRACTOR DIDN'T SIGN THE | | APPLICATION, BUT INFORMATION STILL IS | | REQUIRED). | | B)ENTRY DOORS WITH UPDATED DADE COUNTY | | REPORT WITH LOGO AT BOTTOM LEFT OF 1ST | | PAGE AND WITH LEGIBLE DRAWINGS WITH | | RENEWAL STAMP. | | C)GARAGE DOORS WITH LEGIBLE DRAWINGS. | | D)SITE SPECIFIC ENGINEERING NEED SITE | | SPECIFIC INFORMATION FOR A SPECIFIC | | BUILDING. INFORMATION SUBMITTED FOR | | THE MULLIONS IS GENERIC. NEED COMPLETE | | INFORMATION SPECIFIC TO THIS JOB SITE. | | CLEARLY SPECIFY ALL COMPONENTS TO BE | | USED IN THIS PROJECT. MULLION SIZE, | | ANCHORS, DESIGN PRESSURES ETC. ALSO, | | NEED TO INDICATE THE ADDRESS OF THIS | | PROJECT. | | **ALSO, COMPLETE SITE SPECIFIC FORM AS | | DONE FOR THE SITE SPECIFIC ARCHED | | WINDOWS. | | E)NEED PRODUCT APPROVAL FOR STRUCTURAL | | HEADER ABOVE SLIDING GLASS DOORS. SEE | | PLANS FOR SIZE SPECIFIED. | | F)NEED GLASS PRODUCT APPROVAL WITH | | LEGIBLE DRAWINGS. | | | | 4-REVISE BOLT SIZE SPECIFIED FOR ANCHOR | | SHOWN ON DETAIL 10/A5. SEE SIMPSON | | CATALOGUE. ALSO: NEED TO USE SIMPSON | | CATALOGUE FOR HIGH WIND-RESISTANT | | CONSTRUCTION CATALOGUE SINCE IS THE | | ONLY ONE BEEN REVISED TO COMPLY WITH | | SECTION 1609.4.3 FBC 2001. | | 5-REVISE GABLE END CONSTRUCTION AT | | FAMILY ROOM AREA TO COMPLY WITH SEC. | | 2117.1.2 FBC 2001. | | **ALSO, CLARIFY CONSTRUCTION OF GABLE | | AT REAR PORCH. DETAILS 2/A5 AND 6/A5 | | DON'T APPLY. SEC. 104.2.1.2 CITY | | AMENDMENTS TO FBC 2001. | | 6-OWES $774.32 FOR WESTERN EXPANSION | | FEES AND RADON FEES. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ @ (561)805-6712. | | | | **NOTE: PLEASE INSERT ANY REVISED DWGS | | INTO THE SETS AND DISCARD OLD DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-06-11 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-08 |
Time |
14:28 |
Rev Time |
3.50 |
Received By |
jgomez |
Date |
2003-06-11 |
Time |
16:02 |
Sent To |
|
|
Notes |
2003-06-11 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1-PAY IMPACT FEES. BRING BACK RECEIPT & | | STAMPED PLANS. | | 2-ENERGY CALCULATIONS: A)A/C AREA DOES | | NOT MATCH PLANS. SEE PLANS. | | B)ENERGY CALCULATIONS FOR A MODEL NEEDS | | TO BE WORST CASE SCENARIO. OTHERWISE, | | SITE SPECIFIC ORIENTATION IS REQUIRED. | | ORIENTATION FOR THIS HOUSE DOES NOT | | MATCH ENERGY CALCULATIONS. REVISE AS | | REQUIRED. WORST CASE OR SITE SPECIFIC. | | C)REVISE UNDER ATTIC AREA TO COMPLY WITH | | SEC. 602.1ABC.1.2 CHAPTER 13 FBC 2001. | | 3-PROVIDE SOIL TEST REPORT. | | 4-PROVIDE GENERAL SPECIFICATIONS FOR | | FIREBLOCKING AT ALL CONCEALED SPACES. | | SEC. 2305 FBC 2001. | | 5-DETAIL 5/A5 NEED TO BE REVISED. NEED | | 2X TO SUPPORT WINDOW. SEE PRODUCT | | APPROVAL. | | 6-PROVIDE COMPLETE SPECS FOR GARAGE DOOR | | STRUCTURAL BUCK. NEED ANCHOR EMBEDMENT | | AND WASHER. SEC. 104.2.1.2 CITY AMEND. | | 7-REVISE ROOF NAILING ZONE DIAPHRAGM. | | SEE FIGURE 1606.2(C) FBC 2001 FOR ALL | | CONSIDERED ZONE AREA 3. | | 8-UPDATE TRUSS ANCHOR SCHEDULE AND ALL | | DETAILS THAT NEED TO BE REVISE TO | | COMPLY WITH SEC. 1606.9.4.3 FBC 2001. | | 9-PROVIDE PRODUCT APPROVAL FOR: | | A)ROOF TILE. | | B)ENTRY DOORS WITH UPDATED DADE COUNTY | | REPORT WITH LOGO AT BOTTOM LEFT OF | | FIRST PAGE. ALSO, LEGIBLE DRAWINGS W/ | | UPDATED DADE COUNTY STAMP. | | C)GARAGE DOOR WITH LEGIBLE DRAWINGS. | | D)AS PER THE BUILDING OFFICIAL ALL SITE | | SPECIFIC PRODUCT APPORVALS TO HAVE | | PROFESSIONAL OF RECORD SIGNING AND | | SEALING SAME SITE SPECIFIC FORM (OR | | LETTER CLEARLY IDENTIFYING ALL SITE | | SPECIFIC PRODUCT THAT WERE APPROVED). | | **SEE COMMENTS ON RETURNED PRODUCT | | APPROVALS. | | E)PRODUCT APPROVAL FOR STRUCTURAL | | MULLION ABOVE SLIDING GLASS DOORS. | | F)GLASS BLOCK WITH LEGIBLE DRAWINGS. | | 10-SPECIFY PRODUCT APPROVAL WERE REQ'D. | | SEE PLANS FOR COMMENTS. | | 11-SPECIFY SIZE OF WOOD COLUMNS SHOWN | | ON FRAMING PLAN. SEE SHEET A-5 FOR | | ADDITIONAL COMMENTS. | | 12-SEE SHEET A6 FOR ADDITIONAL COMMENTS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-01-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-01-30 |
Time |
10:04 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-01-30 |
Time |
10:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2004-01-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-29 |
Time |
10:16 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-01-27 |
Time |
12:37 |
Sent To |
|
|
Notes |
2004-01-27 00:00:00 | *********** UNSAT ************** | | | | 1)NOTE: PLEASE HAVE PLANS SIGNED WITH | | A COMPLETE SIGNATURE AS REQ'D PER | | FS481.221 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-12-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-12-16 |
Time |
14:47 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-12-16 |
Time |
14:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-05-14 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-11 |
Time |
14:18 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-05-14 |
Time |
13:26 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2004-01-29 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-29 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-29 |
Time |
10:16 |
Sent To |
E |
|
Notes |
2004-01-29 00:00:00 | TO DP DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-11 |
Time |
14:18 |
Sent To |
|
|
Notes |
2003-12-11 00:00:00 | TO BT DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2003-08-21 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-21 |
Time |
12:57 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-21 |
Time |
12:57 |
Sent To |
B |
|
Notes |
2003-08-21 00:00:00 | TO JG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2003-08-18 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-18 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-18 |
Time |
10:10 |
Sent To |
B |
|
Notes |
2003-08-18 00:00:00 | TO JG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-08-06 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-06 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-06 |
Time |
15:26 |
Sent To |
B |
|
Notes |
2003-08-06 00:00:00 | TO JGOMEZ DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-07-31 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-31 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-31 |
Time |
16:53 |
Sent To |
B |
|
Notes |
2003-07-31 00:00:00 | TO JG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-07-16 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-16 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-16 |
Time |
10:48 |
Sent To |
B |
|
Notes |
2003-07-16 00:00:00 | JGOMEZ DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-07-08 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-08 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-08 |
Time |
14:28 |
Sent To |
B |
|
Notes |
2003-07-08 00:00:00 | JGOMEZ DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-04-30 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-30 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-30 |
Time |
09:24 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-08-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-05-17 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2003-08-05 |
Time |
12:40 |
Sent To |
|
|
Notes |
2003-08-05 00:00:00 | PASSED BY PATTY KRAUSS. 5-24-03. SEE | | PLANS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-05-17 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-05-14 |
Time |
13:37 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2003-05-17 |
Time |
09:55 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-04-30 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-30 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
E |
|
Notes |
|
|