Plan Review Details - Permit 03041784
Plan Review Stops For Permit 03041784
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-06-16 Cont ID  
Sent By jwitmer Date 2003-06-16 Time 16:36 Rev Time 1.25
Received By jwitmer Date 2003-06-16 Time 16:19 Sent To  
Notes
2003-06-16 00:00:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 03041784
 ADDRESS: 2626 SANDY CAY
 CONT: TAZ CONSTRUCTION
 TELL # (954)340-1744
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 *******PROVISO*********
 SOILS REPORT UES REPORT # 7439
 4.3 BUILDING FOUNDATIONS,ALL FINAL DE-
 SIGNS SHOULD BE BASED ON A MORE COMPRE-
 HENSIVE STUDY ONCE ALL BUILDING LOCA-
 TIONS AND STRUCTURAL LOADS ARE FINALIZED
 BUILDER CONTINUING AT OWN RISK.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)805-6715

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-22 Cont ID  
Sent By shernand Date 2003-06-13 Time 14:46 Rev Time 1.55
Received By jwitmer Date 2003-05-22 Time 12:40 Sent To  
Notes
2003-05-22 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03041784
 ADD: 2626 SANDY CAY
 CONT: TAZ CONSTRUCTION
 TEL: (954)340-1744
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
 1)SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 OF RECORD.
 MISSING ADDRESS OF LOT FOR SITE SPECIFIC
 ENGINEERING, MISSING SEAL AND SIGNATURE
 OF DESIGN PROFESSIONAL.
  
 2)1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
  
 RE-EVALUATE TRUSS ANCHOR SCHEDULE!!!
  
 3) SHEET A-5 DETAIL 15 THE WRONG APPLICA
 TION FOR A MSH 218 (STRAP HANGER) NOT
 A HOLD DOWN DEVICE!!!!!
  
 4) SHEET A-5 DETAIL 8 MSTA 18 STRAP,
 RE-EVALUATE USING 2003 CATALOG.
  
 5) SHEET 5 DETAIL 6 IS THIS CORRECT
 USING THROUGH BOLTS?
  
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)659-8096 X 8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-12-12 Cont ID  
Sent By dpalmer Date 2003-12-12 Time 13:07 Rev Time 0.33
Received By dpalmer Date 2003-12-12 Time 13:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-10-02 Cont ID  
Sent By csiegber Date 2003-12-11 Time 14:21 Rev Time 0.33
Received By btrobaug Date 2003-10-02 Time 10:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-12 Cont ID  
Sent By csiegber Date 2003-09-30 Time 11:53 Rev Time 0.50
Received By btrobaug Date 2003-05-12 Time 10:01 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-12-11 Cont ID  
Sent By csiegber Date 2003-12-11 Time 14:20 Rev Time 0.00
Received By csiegber Date 2003-12-11 Time 14:20 Sent To E
Notes
2003-12-11 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-09-30 Cont ID  
Sent By csiegber Date 2003-09-30 Time 11:53 Rev Time 0.00
Received By csiegber Date 2003-09-30 Time 11:53 Sent To E
Notes
2003-09-30 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-13 Cont ID  
Sent By shernand Date 2003-06-13 Time 14:46 Rev Time 0.00
Received By shernand Date 2003-06-13 Time 14:46 Sent To B
Notes
2003-06-13 00:00:00JW DESK

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-22 Cont ID  
Sent By kstevens Date 2003-05-16 Time 18:24 Rev Time 0.00
Received By jwitmer Date 2003-05-22 Time 12:39 Sent To  
Notes
2003-05-22 00:00:00OK PER PH KRAUSS 5/19/03

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-05-16 Cont ID  
Sent By btrobaug Date 2003-05-12 Time 10:14 Rev Time 0.33
Received By kstevens Date 2003-05-16 Time 18:23 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-12 Cont ID  
Sent By btrobaug Date 2003-05-12 Time 10:00 Rev Time 0.50
Received By btrobaug Date   Time   Sent To E
Notes
2003-05-12 00:00:00OK PER SHIRLEY./WRT.