|
 |
 |
 |
 |
 |
Plan Review Details - Permit 03041728
Plan Review Stops For Permit 03041728 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-05-13 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-05-13 |
Time |
07:39 |
Rev Time |
0.50 |
Received By |
sthyng |
Date |
2003-05-13 |
Time |
07:39 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-05-08 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-12 |
Time |
09:27 |
Rev Time |
0.50 |
Received By |
sthyng |
Date |
2003-05-08 |
Time |
09:06 |
Sent To |
|
|
Notes |
2003-05-08 00:00:00 | ****CORRECTIONS**** | | | | 1.)INCLUDE STANDARD SAFETY ITEMS FOR | | POOLS ON PLAN. | | | | 2.)SPECIFY POOL EQUIPMENT ATTACHMENTS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-05-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-04-30 |
Time |
13:56 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2003-05-02 |
Time |
10:31 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-05-12 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-12 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-12 |
Time |
09:27 |
Sent To |
B |
|
Notes |
2003-05-12 00:00:00 | STHYNG DESK, RESUB. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-04-23 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-23 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-23 |
Time |
10:43 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-05-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-05-21 |
Time |
16:01 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2003-05-21 |
Time |
16:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-04-30 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-05-13 |
Time |
07:43 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-04-30 |
Time |
13:56 |
Sent To |
E |
|
Notes |
2003-04-30 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | FORMATION REQUIRED FOR PLAN REVIEW | | 1) FBC-2001424.2.7.1 POOL CIRCULATING | | PUMPS SHALL BE EQUIPPED ON THE INLET | | SIDE WITH AN APPROVED TYPE HAIR AND LINT | | STRAINER WHEN USED WITH A PRESSURE FIL- | | TER. (DETAIL) | | 2) FBC-2001 424.2.7.2 PUMPS AND EQUIP- | | MENT SHALL BE MOUNTED ON A SUBSTANTIAL | | BASE IN A MANNER THAT WILL ELIMINATE | | STRAIN ON PIPING. SLAB SHALL BE A NOMIN- | | AL 4" THICK. (DETAIL) | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-04-30 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-23 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |