Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-06-04 Cont ID  
Sent By sthyng Date 2003-06-04 Time 12:41 Rev Time 2.00
Received By sthyng Date 2003-06-04 Time 12:41 Sent To  
Notes
2003-06-04 00:00:00*****PROVISO*******
 SUBMIT PRODUCT APPROVALS FOR
 THE SLIDING GLASS DOOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-23 Cont ID  
Sent By shernand Date 2003-06-03 Time 15:45 Rev Time 3.00
Received By sthyng Date 2003-05-22 Time 16:06 Sent To  
Notes
2003-05-23 00:00:00*******CORRECTIONS*******
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PROVIDE THE ORIGINAL RECEIPT FOR
 THE IMPACT FEES PAID TO PALM BEACH
 COUNTY.
  
 2.)DOOR AND WINDOW BUCK DETAILS MUST
 COMPLY WITH FBC 1704.2.2.
  
 3.)PROVIDE A DETAIL FOR THE PRIVACY
 WALL SHOWN ON THE SITE PLAN.ALSO
 SHOW ON THE FOUNDATION PLAN IF IT IS
 TO HAVE A FOOTER.
  
 4.)THE SEMCO ATTACHMENT SPECIFIED IN
 THE WOOD FRAME TO CONCRETE WALL
 CONNECTION (A5) IS NOT AVAILABLE.
 PROVIDE ANCHOR LENGTH.
  
 5.)THE TEXT, EXTERIOR WINDOW HEADER
 (S3) IS ILLEGIBLE.
  
 6.)UPLIFT VALUES FOR CONNECTIONS ARE
 INCORRECT; REFER TO USP 2003 CATALOG.
  
 7.)THE STAIR RAIL IS SHOWN AS 42" ON
 THE FLOOR PLAN AND NOTE 1 (A4), BUT IS
 36" ON THE SECTION.EITHER COMPLIES,
 BUT MAKE ALL DETAILS AND DIMENSIONS
 MATCH.
  
 8.)PROVIDE A SOILS INVESTIGATION
 REPORT.
  
 9.)THE TEXT FOR "GUARDRAIL" AND THE
 DIMENSION ARE OVERLAYED; STAIR SECTION
 (A4); MAKE LEGIBLE.
  
 10.)NOTES 6 & 7, EXTERIOR STUCCO (A4),
 RIB LATH IS TO BE ATTACHED AT EACH
 RIB, FBC 2504.2.
  
 11.)DRAFTSTOPPING REQUIRED, FBC 705.3.
  
 12.)PROVIDE PRODUCT APPROVALS FOR THE
 SLIDING GLASS DOOR.
  
 13.)THE OVERHANG OF THE ROOF HAS
 SOFFIT VENTS ONTO THE ADJACENT PROPERTY
 (ZERO LOT LINE SIDE), AND THE ROOF
 DRAINS WATER ONTO THE ADJACENT PROPERTY.
 IS THIS COVERED IN AN EASEMENT? EITHER
 ADDRESS ON THE PLAN, OR PROVIDE A COPY
 OF THE EASEMENT.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-10-02 Cont ID  
Sent By dpalmer Date 2003-10-02 Time 07:23 Rev Time 0.50
Received By dpalmer Date 2003-10-02 Time 07:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-12 Cont ID  
Sent By csiegber Date 2003-09-23 Time 16:44 Rev Time 0.50
Received By btrobaug Date 2003-05-12 Time 07:03 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-23 Cont ID  
Sent By csiegber Date 2003-09-23 Time 16:44 Rev Time 0.00
Received By csiegber Date 2003-09-23 Time 16:44 Sent To E
Notes
2003-09-23 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-03 Cont ID  
Sent By shernand Date 2003-06-03 Time 15:45 Rev Time 0.00
Received By shernand Date 2003-06-03 Time 15:45 Sent To B
Notes
2003-06-03 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-23 Cont ID  
Sent By shernand Date 2003-04-23 Time 10:13 Rev Time 0.00
Received By shernand Date 2003-04-23 Time 10:13 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-19 Cont ID  
Sent By kstevens Date 2003-05-16 Time 17:54 Rev Time 0.30
Received By pkrauss Date 2003-05-19 Time 13:16 Sent To B
Notes
2003-05-19 00:00:00MECHANICAL PERMIT 03041715

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-05-16 Cont ID  
Sent By btrobaug Date 2003-05-12 Time 07:19 Rev Time 0.33
Received By kstevens Date 2003-05-16 Time 17:54 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-25 Cont ID  
Sent By shernand Date 2003-04-23 Time 10:13 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***