Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-01 Cont ID  
Sent By jgomez Date 2003-07-01 Time 14:25 Rev Time 0.50
Received By jgomez Date 2003-07-01 Time 14:25 Sent To PC
Notes
2003-07-01 00:00:00BUILDING REVIEW PROCESS.
 1-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOOR WITH SIDELITE SINGLE ASSEMBLY AS
 SHOWN ON PLANS.
 2-UPDATE TRUSS ANCHOR SCHEDULE AND ALL
 DETAILS THAT ARE AFFECTED BY SECTION
 1609.4.3 FBC 2001, WHICH DOES NOT
 ALLOW STEEL STRESS TO BE INCREASED.
 3-GLASS BLOCK AT BATH TUB TO BE SAFETY
 GLASS IF FACE THICKNESS IS LESS THAN
 0.25". SEC. 2405.2 FBC 2001.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-05-22 Cont ID  
Sent By shernand Date 2003-06-03 Time 08:19 Rev Time 2.00
Received By jgomez Date 2003-05-22 Time 13:40 Sent To PC
Notes
2003-05-22 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-GLASS BLOCK TO BE SAFETY GLASS IF FACE
 THICKNESS IS LESS THAN 0.25". SECTION
 2405.2.2 FBC 2001.
 2-PROVIDE INFORMATION FOR STORM SHUTTERS
 UPDATED SBCCI REPORT.
 3-REVISE FASTENER SPECIFICATIONS ON
 DETAIL 3 ON S-2 TO MATCH THE DIAPHRAGM
 SCHEDULE.
 4-PROVIDE GENERAL SPECIFICATIONS FOR
 FIREBLOCKING AT ALL CONCEALED SPACES
 AS REQUIRED BY SEC. 2305 FBC 2001.
 5-ENTRY SECTION ON SHEET A-3: REVISE
 RECESS HEIGHT TO ALLOW FOOTING TO BE
 12" BELOW GRADE. SEE COMMENTS ON SHEET
 A-3. SEC. 1804.1.3 FBC 2001.
 6-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOOR WITH SIDELITE SINGLE ASSEMBLY AS
 SHOWN ON PLANS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-08-27 Cont ID  
Sent By dpalmer Date 2003-08-27 Time 07:38 Rev Time 0.25
Received By dpalmer Date 2003-08-27 Time 07:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-08 Cont ID  
Sent By csiegber Date 2003-08-19 Time 14:33 Rev Time 0.50
Received By btrobaug Date 2003-05-08 Time 09:52 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-08-21 Cont ID  
Sent By csiegber Date 2003-08-21 Time 13:11 Rev Time 0.00
Received By csiegber Date 2003-08-21 Time 13:11 Sent To M
Notes
2003-08-21 00:00:00TO PK DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-19 Cont ID  
Sent By csiegber Date 2003-08-19 Time 14:33 Rev Time 0.00
Received By csiegber Date 2003-08-19 Time 14:33 Sent To E
Notes
2003-08-19 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-03 Cont ID  
Sent By shernand Date 2003-06-03 Time 08:19 Rev Time 0.00
Received By shernand Date 2003-06-03 Time 08:19 Sent To B
Notes
2003-06-03 00:00:00JGOMEZ DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-23 Cont ID  
Sent By shernand Date 2003-04-23 Time 09:23 Rev Time 0.00
Received By shernand Date 2003-04-23 Time 09:23 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-09-04 Cont ID  
Sent By pkrauss Date 2003-09-04 Time 08:38 Rev Time 0.25
Received By pkrauss Date 2003-09-04 Time 08:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-15 Cont ID  
Sent By csiegber Date 2003-08-21 Time 13:13 Rev Time 0.20
Received By pkrauss Date 2003-05-15 Time 09:49 Sent To B
Notes
2003-05-15 00:00:00MECHANICAL PERMIT 03041639

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-05-10 Cont ID  
Sent By btrobaug Date 2003-05-08 Time 09:52 Rev Time 0.33
Received By kstevens Date 2003-05-10 Time 16:49 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-30 Cont ID  
Sent By shernand Date 2003-04-23 Time 09:23 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved