Plan Review Details - Permit 03041623
Plan Review Stops For Permit 03041623
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-01 Cont ID  
Sent By jgomez Date 2003-07-01 Time 11:00 Rev Time 0.50
Received By jgomez Date 2003-07-01 Time 11:00 Sent To PC
Notes
2003-07-01 00:00:00BUILDING REVIEW PROVISO:
 1-STORM SHUTTERS INSTALLATION SCHEDULE:
 REVISE THE SPACING FOR WOOD ANCHORS.
 SEE THE ENGINEERED DRAWINGS.
 2-REVISE EXTERIOR FRONT ELEVATION TO
 REFLECT CHANGE OF WINDOW FROM SINGLE
 HUNG TO HORIZONTAL SLIDER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-05-23 Cont ID  
Sent By shernand Date 2003-06-03 Time 08:21 Rev Time 2.00
Received By jgomez Date 2003-05-23 Time 17:38 Sent To  
Notes
2003-05-23 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE UPDATED SBCCI REPORT FOR STORM
 SHUTTERS.
 2-REVISE DETAIL S21 FOR COLUMN LOCATED
 BETWEEN GARAGE AND STAIRWAY TO MATCH
 CONDITIONS SHOWN ON 2ND FLOOR FRAMING
 PLAN. SEC.104.2.1.2 CITY AMENDMENTS TO
 FBC 2001.
 3-WINDOW 34SH DOESN'T PROVIDE THE 24"
 CLEAR HEIGHT REQUIRED BY SEC. 1005.4
 FBC 2001. REVISE AS REQUIRED.
 4-REVISE TRUSS ANCHOR SCHEDULE TO COMPLY
 WITH SEC. 1609.4.3 FBC 2001, WHICH
 DOESN'T ALLOW THE 33% ALLOWABLE STRESS
 INCREASE TO BE USED. SEE USP 2003
 CATALOGUE, WHICH PUBLICATED THE
 REVISED LOADS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-09-30 Cont ID  
Sent By btrobaug Date 2003-09-30 Time 12:06 Rev Time 0.33
Received By btrobaug Date 2003-09-30 Time 12:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-12 Cont ID  
Sent By csiegber Date 2003-09-17 Time 16:32 Rev Time 0.50
Received By btrobaug Date 2003-05-12 Time 06:05 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-29 Cont ID  
Sent By csiegber Date 2003-09-29 Time 11:07 Rev Time 0.00
Received By csiegber Date 2003-09-29 Time 11:07 Sent To M
Notes
2003-09-29 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-17 Cont ID  
Sent By csiegber Date 2003-09-17 Time 16:32 Rev Time 0.00
Received By csiegber Date 2003-09-17 Time 16:32 Sent To E
Notes
2003-09-17 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-03 Cont ID  
Sent By shernand Date 2003-06-03 Time 08:21 Rev Time 0.00
Received By shernand Date 2003-06-03 Time 08:21 Sent To B
Notes
2003-06-03 00:00:00JGOMEZ DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-22 Cont ID  
Sent By shernand Date 2003-04-22 Time 16:01 Rev Time 0.00
Received By shernand Date 2003-04-22 Time 16:01 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-10-01 Cont ID  
Sent By pkrauss Date 2003-10-01 Time 07:33 Rev Time 0.20
Received By pkrauss Date 2003-10-01 Time 07:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-19 Cont ID  
Sent By csiegber Date 2003-09-29 Time 11:07 Rev Time 0.20
Received By pkrauss Date 2003-05-19 Time 13:13 Sent To B
Notes
2003-05-19 00:00:00MECHANICAL PERMIT 03041625

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-04-26 Cont ID  
Sent By jleech Date 2003-04-26 Time 13:36 Rev Time 0.33
Received By jleech Date 2003-04-26 Time 13:36 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-25 Cont ID  
Sent By shernand Date 2003-04-22 Time 16:01 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***