Plan Review Details - Permit 03041476
Plan Review Stops For Permit 03041476
Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status F Date 2004-03-03 Cont ID  
Sent By shill Date 2004-03-03 Time 14:15 Rev Time 0.50
Received By shill Date 2004-03-03 Time 14:15 Sent To  
Notes
2004-03-03 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 STAIR DRAWINGS PREPARED BY ORLANDO
 M. FORTUN CONSULTING ENGINEERS, PA
  
 THE AUTHORIZATION NUMBER IS TO BE ON
 EACH SHEET.THE PRINTED NAME &LICENSE#
 OF THE PERSON SEALING THE DOCUMENT IS TO
 BE ON EACH SHEET.THE SIGNATURE IS TO
 BE A FULL SIGNATURE AS PER THE FBPE AND
 BUILDING OFFICIAL.THE RAISED SEAL IS
 TO BE LEGIBLE.
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2004-03-03 Cont ID  
Sent By shill Date 2004-03-03 Time 14:11 Rev Time 0.50
Received By shill Date 2004-03-03 Time 14:11 Sent To  
Notes
2004-03-03 00:00:00REVISED A7, A8, A9 DATED 2/10/04

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2004-01-29 Cont ID  
Sent By btrobaug Date 2004-02-18 Time 12:52 Rev Time 0.50
Received By shill Date 2004-01-29 Time 19:14 Sent To  
Notes
2004-01-29 00:00:00****CORRECTIONS****
 REVISION
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 1.)FASTENERS FOR USP TA20R CONFLICT
 WITH THE CATALOG.
  
 2.)SUBMIT ORIGINAL, SEALED STAIR
 DETAILS.FINAL DRAWINGS FILED FOR
 PUBLIC RECORD ARE TO BE SIGNED, DATED
 AND SEALED FS471.025.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status N Date 2004-01-02 Cont ID  
Sent By btrobaug Date 2004-01-27 Time 10:57 Rev Time 0.50
Received By shill Date 2004-01-02 Time 10:24 Sent To  
Notes
2004-01-02 00:00:00RESTAMP

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-06-12 Cont ID  
Sent By csiegber Date 2003-12-31 Time 13:08 Rev Time 0.50
Received By sthyng Date 2003-06-12 Time 15:19 Sent To  
Notes
2003-06-12 00:00:00*****PROVISO********
 SUBMIT HURRICANE SHUTTER ATTACHMENT
 SCHEDULE WITH CORRECT ANCHORS AND
 SPACING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-06-11 Cont ID  
Sent By shernand Date 2003-06-12 Time 15:13 Rev Time 1.00
Received By sthyng Date 2003-06-11 Time 13:21 Sent To  
Notes
2003-06-11 00:00:00IMPACT FEES ONLY

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-06-04 Cont ID  
Sent By shernand Date 2003-06-11 Time 10:26 Rev Time 1.00
Received By sthyng Date 2003-06-04 Time 14:17 Sent To  
Notes
2003-06-04 00:00:00*****CORRECTIONS******
  
 1.)IMPACT FEES; SEE PREVIOUS LIST
 ITEM #2.
  
 2.)ITEM #3 FROM PREVIOUS LIST NOT
 ADDRESSED (COLUMN LEGEND ILLEGIBLE ON
 SHEET A3).
  
 3.)ITEM #4 FROM PREVIOUS LIST;U WAS
 CORRECTED BUT NOT BB.
  
 4.)ITEM #5 FROM PREVIOUS LIST; Q & R
 AS TEMPERED ON WINDOW SCHEDULE.
  
 5.)ITEM #7 FROM PREVIOUS LIST; TRUSS
 CONNECTORS FROM 2003 CATALOG; DO NOT
 INCLUDE STRESS INCREASES FOR STEEL.
 READ PP 6 & 7 OF USP CATALOG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-16 Cont ID  
Sent By pkrauss Date 2003-06-04 Time 11:35 Rev Time 3.00
Received By sthyng Date 2003-05-15 Time 12:05 Sent To  
Notes
2003-05-15 00:00:00**********CORRECTIONS***********
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY; CALL 233-5025 FOR MORE
 INFORMATION.THE PLANS MUST BE STAMPED
 AND THE RECEIPT ATTACHED TO THE
 APPLICATION.
  
 3.)THE COLUMN LEGEND ON SHEET A3 IS
 PARTIALLY ILLEGIBLE.
  
 4.)SHOW WINDOWS BB AND U AS TEMPERED
 ON THE FLOOR PLAN, SHEET A6.
  
 5.)SHOW WINDOWS Q AND R AS TEMPERED
 ON THE WINDOW SCHEDULE, A1.
  
 6.)THE WINDOW AND SGD JAMB DETAIL,
 AND THE 'REPAIR MASONRY GAPS' DETAIL,
 SHEET A12, MUST COMPLY WITH FBC
 1707.4.4.2.
  
 7.)SOME VALUES FOR THE USP CONNECTORS
 ARE INCORRECT (SHEET A8).REFER TO
 THE 2003 CATALOG.
  
 8.)PROVIDE LEGIBLE PRODUCT APPROVALS
 (SINGLE HUNG WINDOW, TILE SPECS).
  
 9.)SOME PANEL LENGTHS ON THE
 HURRICANE SHUTTER INSTALLATION SCHEDULE
 EXCEED THE MAX LENGTH FOR THE DESIGN
 PRESSURE INDICATED.REVISE.
  
 10.)SHEET A5, BEARING WALL NOTE IS
 ILLEGIBLE.
  
 11.)PROVIDE A SOILS INVESTIGATION
 REPORT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-02-18 Cont ID  
Sent By btrobaug Date 2004-02-18 Time 12:51 Rev Time 0.33
Received By btrobaug Date 2004-02-18 Time 12:38 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-01-27 Cont ID  
Sent By csiegber Date 2004-02-17 Time 08:46 Rev Time 0.50
Received By btrobaug Date 2004-01-27 Time 10:55 Sent To B
Notes
2004-01-27 00:00:00 
 FAILED
 ~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE RISER DIAGRAM AND THE PANEL
 SCHEDULE FEEDER SIZE FOR SUB PANEL DO
 NOT CORRELATE.SEE 1-15 #14 ON SCHEDULE
 & 3 #6'S ON RISER.
  
 2} REVISION #3 SHOWS THE ADDITION OF
 AN"INSTA HOT",BUT THE ADDED LOAD DOES
 NOT APPEAR ON THE SCHEDULE.
  
 3} PLEASE RECALCULATE THE TOTAL LOAD.
 45.7 DOES NOT SEEM TO BE CORRECT.
  
 4} THE TITLE BLOCK DOES NOT CONTAIN THE
 FIRM LICENSE NUMBER PER 61G1-16.004(2).
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-30 Cont ID  
Sent By sgraham Date 2003-04-25 Time 08:43 Rev Time 0.50
Received By btrobaug Date 2003-04-30 Time 09:29 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-02-17 Cont ID  
Sent By csiegber Date 2004-02-17 Time 08:46 Rev Time 0.00
Received By csiegber Date 2004-02-17 Time 08:46 Sent To E
Notes
2004-02-17 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-12-31 Cont ID  
Sent By csiegber Date 2003-12-31 Time 13:08 Rev Time 0.00
Received By csiegber Date 2003-12-31 Time 13:08 Sent To B
Notes
2003-12-31 00:00:00TO SH DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-06-12 Cont ID  
Sent By shernand Date 2003-06-12 Time 15:13 Rev Time 0.00
Received By shernand Date 2003-06-12 Time 15:13 Sent To B
Notes
2003-06-12 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-06-11 Cont ID  
Sent By shernand Date 2003-06-11 Time 10:26 Rev Time 0.00
Received By shernand Date 2003-06-11 Time 10:26 Sent To B
Notes
2003-06-11 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-28 Cont ID  
Sent By shernand Date 2003-05-28 Time 15:30 Rev Time 0.00
Received By shernand Date 2003-05-28 Time 15:30 Sent To P
Notes
2003-05-28 00:00:00KSTEVENS DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-21 Cont ID  
Sent By shernand Date 2003-04-21 Time 09:13 Rev Time 0.00
Received By shernand Date 2003-04-21 Time 09:13 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-06-04 Cont ID  
Sent By pkrauss Date 2003-06-04 Time 11:29 Rev Time 0.10
Received By pkrauss Date 2003-06-04 Time 11:23 Sent To B
Notes
2003-06-04 00:00:00MECHANICAL PERMIT 03041525
 PLANS APPROVED 5-14-03

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-05-15 Cont ID  
Sent By kstevens Date 2003-05-31 Time 07:45 Rev Time 0.20
Received By pkrauss Date 2003-05-15 Time 09:50 Sent To B
Notes
2003-05-15 00:00:00DENIED:MECHANICAL PERMIT 03041525
  
 MECHANICAL FLOOR PLAN DOES NOT MATCH A-5
 & A-6.MECHANICAL FLOOR PLAN IS
 "REVERSED".PLEASE CLARIFY
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-05-31 Cont ID  
Sent By kstevens Date 2003-05-31 Time 07:45 Rev Time 0.33
Received By kstevens Date 2003-05-31 Time 07:34 Sent To M
Notes
2003-05-31 00:00:00PASSED/PROVISO - REVISION REQUIRED -
 TUB & SHR NOT VENTED.

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-05-10 Cont ID  
Sent By shernand Date 2003-05-28 Time 15:30 Rev Time 0.50
Received By kstevens Date 2003-05-10 Time 15:39 Sent To M
Notes
2003-05-10 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN.
 2) SHOWER NOT SHOWN ON FIRST FLOOR.
 3) MASTER BATH IS OVER KITCHEN AND BATH
 #2 IS ON THE OTHER SIDE OF THE HOUSE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-25 Cont ID  
Sent By shernand Date 2003-04-21 Time 09:13 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved