2003-05-22 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03041277
 ADD: 8179 SPYGLASS DRIVE
 CONT: WESTBROOKE
 TEL: (305)796-4185
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
 1) BEDROOM # 3 EGRESS WINDOW SH 34
 20 INCHES CLEAR NET HEIGHT/ REQUIRED 24"
 2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR.
  
 2)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 DISCREPANCY ENERGY CALS SEER 12/ PLANS
 INDICATEA SEER OF 11.
  
 3)1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
  
 RE-EVALUATE TRUSS ANCHOR SCHEDULE
 USE 2003 USP CATALOG VALUES WITH NO
 INCREASE TAKEN
  
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)659-8096 X 8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-12-16 Cont ID  
Sent By btrobaug Date 2003-12-16 Time 13:07 Rev Time 0.50
Received By btrobaug Date 2003-12-16 Time 13:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-12-05 Cont ID  
Sent By csiegber Date 2003-12-11 Time 14:48 Rev Time 0.50
Received By btrobaug Date 2003-12-05 Time 15:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-29 Cont ID  
Sent By csiegber Date 2003-12-04 Time 11:38 Rev Time 0.50
Received By btrobaug Date 2003-04-29 Time 18:18 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-12-11 Cont ID  
Sent By csiegber Date 2003-12-11 Time 14:48 Rev Time 0.00
Received By csiegber Date 2003-12-11 Time 14:48 Sent To E
Notes
2003-12-11 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-12-04 Cont ID  
Sent By csiegber Date 2003-12-04 Time 11:38 Rev Time 0.00
Received By csiegber Date 2003-12-04 Time 11:38 Sent To E
Notes
2003-12-04 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-10-07 Cont ID  
Sent By csiegber Date 2003-10-07 Time 13:51 Rev Time 0.00
Received By csiegber Date 2003-10-07 Time 13:51 Sent To B
Notes
2003-10-07 00:00:00TO JW DESK/RE-STAMP

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-01 Cont ID  
Sent By csiegber Date 2003-10-01 Time 14:48 Rev Time 0.00
Received By csiegber Date 2003-10-01 Time 14:48 Sent To M
Notes
2003-10-01 00:00:00TO PK BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-29 Cont ID  
Sent By shernand Date 2003-05-29 Time 08:19 Rev Time 0.00
Received By shernand Date 2003-05-29 Time 08:19 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-21 Cont ID  
Sent By shernand Date 2003-05-21 Time 14:32 Rev Time 0.00
Received By shernand Date 2003-05-21 Time 14:32 Sent To B
Notes
2003-05-21 00:00:00JW DESK

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-10-03 Cont ID  
Sent By pkrauss Date 2003-10-03 Time 06:57 Rev Time 0.25
Received By pkrauss Date 2003-10-03 Time 06:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-05-30 Cont ID  
Sent By csiegber Date 2003-10-01 Time 14:48 Rev Time 0.25
Received By pkrauss Date 2003-05-30 Time 10:19 Sent To B
Notes
2003-05-30 00:00:0003041397

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-05-13 Cont ID  
Sent By shernand Date 2003-05-29 Time 08:19 Rev Time 0.20
Received By pkrauss Date 2003-05-13 Time 10:18 Sent To B
Notes
2003-05-13 00:00:00DENIED:MECHANICAL PERMIT 03041397
  
 ENERGY CALCS INDICATE A 12 SEER TO BE
 INSTALLED, PLANS SHOW A 11 SEER.
 PLEASE CORRELATE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-05-10 Cont ID  
Sent By btrobaug Date 2003-04-29 Time 18:18 Rev Time 0.33
Received By kstevens Date 2003-05-10 Time 14:46 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-25 Cont ID  
Sent By sgraham Date 2003-04-25 Time 11:48 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved