Plan Review Stops For Permit 03041216 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2003-10-03 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-10-06 |
Time |
16:07 |
Rev Time |
0.50 |
Received By |
sthyng |
Date |
2003-10-03 |
Time |
14:53 |
Sent To |
Z |
|
Notes |
2003-10-03 00:00:00 | REVISION TO ADD PORCH | | | | SENT TO ZONING FOR REVIEW |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2003-07-28 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-29 |
Time |
11:35 |
Rev Time |
0.50 |
Received By |
sthyng |
Date |
2003-07-28 |
Time |
14:11 |
Sent To |
M |
|
Notes |
2003-07-28 00:00:00 | REVISION TO ADD NEW BATH |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2003-07-11 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-24 |
Time |
16:16 |
Rev Time |
0.50 |
Received By |
sthyng |
Date |
2003-07-11 |
Time |
18:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2003-07-09 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-07-09 |
Time |
12:24 |
Rev Time |
0.50 |
Received By |
sthyng |
Date |
2003-07-09 |
Time |
12:24 |
Sent To |
|
|
Notes |
2003-07-09 00:00:00 | *******CORRECTIONS******* | | | | 1.)THE 8 1/2 X 11 SHEETS SEALED BY | | THE ARCHITECT ADDRESSING THE FIRST | | CORRECTION LIST ARE NO LONGER IN THE | | PACKAGE.PLEASE SUBMIT. | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-06-27 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-06-30 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-06-27 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-06-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-06-26 |
Time |
11:30 |
Rev Time |
1.00 |
Received By |
sthyng |
Date |
2003-06-10 |
Time |
14:20 |
Sent To |
|
|
Notes |
2003-06-10 00:00:00 | ******CORRECTIONS******* | | | | 1.)SEPARATE PERMITS REQUIRED. | | | | 2.)THE STRUCTURAL CORRECTIONS | | SUBMITTED WERE ACCEPTABLE, BUT MUST BE | | SEALED, SIGNED AND DATED. | | | | 3.)THE PRODUCT APPROVALS SUBMITTED | | FOR THE WINDOWS USED ASTM E330-97, FBC | | SPECIFIES ASTM E330-84 (CHAPTER 34). | | A SITE SPECIFIC MAY BE SUBMITTED AS A | | PRODUCT APPROVAL IF AN FBC PRODUCT | | APPROVAL IS NOT AVAILABLE.SEE | | ATTACHED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-05-10 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-06-10 |
Time |
11:30 |
Rev Time |
3.00 |
Received By |
sthyng |
Date |
2003-05-09 |
Time |
18:35 |
Sent To |
|
|
Notes |
2003-05-10 00:00:00 | ******CORRECTIONS******* | | | | 1.)SEPARATE PERMITS REQUIRED; ROOF, | | MECHANICAL, PLUMBING, ELECTRICAL. | | | | 2.)SHOW DIMENSION OF SPLASHBLOCK FOR | | DOWNSPOUTS FBC 1503.4.4. | | | | 3.)ADDITIONAL FEES DUE; $99.25. | | | | 4.)PROVIDE TWO COPIES OF PRODUCT | | APPROVALS FOR THE FOLLOWING: | | DOUBLE HUNG WINDOW | | CASEMENT WINDOW | | FRENCH DOORS | | MULLIONS | | TRANSOM | | SIDELITES | | SHUTTERS | | BARREL TILE | | | | 5.)ENERGY CALCS REQUIRED FBC 13-101.2. | | | | 6.)PAGE SEM-1 REFERS TO A SOILS | | REPORT.IF THIS REPORT IS AVAILABLE, | | PLEASE PROVIDE. | | | | 7.)FIRESTOP REQUIRED 705.3. | | | | 8.)SOFFIT VENTILATION REQUIRED | | FBC 2309.7. | | | | 9.)IMPACT PROTECTION REQUIRED FOR | | OPENINGS, FBC 1606.1.4. | | | | 10.) PROVIDE A ROOF SHEATHING ATTACHMENT | | SCHEDULE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
N |
Date |
2003-07-08 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-10 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2003-07-08 |
Time |
13:39 |
Sent To |
|
|
Notes |
2003-07-08 00:00:00 | THE SCOPE OF THE WORK APPLIED FOR | | REQUIRES AN ELECTRICAL PERMIT.PLEASE | | RESUBMIT DRAWINGS AT THE TIME OF | | APPLICATION. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2003-06-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-07-07 |
Time |
18:26 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2003-06-26 |
Time |
08:46 |
Sent To |
B |
|
Notes |
2003-06-26 00:00:00 | UNSAT | | ~~~~~ | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | ANY CHANGES TO PLANS DRAWN BY AN | | ARCHITECT MUST BE INITIALED BY SAME PER | | FS.481. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-06-03 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-25 |
Time |
14:52 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-06-03 |
Time |
12:01 |
Sent To |
P |
|
Notes |
2003-06-03 00:00:00 | UNSAT | | ~~~~~ | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | PLEASE PROVIDE PANEL SCHEDULES AND LOAD | | CALCULATIONS FOR ALL EXISTING AND NEW | | LOADS BEING ADDED.THE PLAN SHOWS A NEW | | LAUNDRY BUT ONLY LISTS ONE WASHER AND | | DRYER IN THE CALCULATIONS.ALSO THERE IS | | A NEW AHU AND ONLY ONE IN THE CALCS. | | | | INDICATE THE SERVICE SIZE,FEEDER AND CO | | NDUIT SIZES ON THE RISER DIAGRAM PER | | 215-5. | | | | NOTE: PLEASE SHOW ALL OUTLET SPACING | | TO MEET 2',6',12' RULE PER 210-52. | | | | NOTE: PLEASE NOTE THAT ALL PLANS | | DRAWN BY AN ARCHITECT/ENGINEER CONTAIN- | | ING A TITLE BLOCK, MUST BE SIGNED, | | DATEDAND SEALED BY THE ARCH/ENGINEER OF | | RECORD. PER FS/FAC 481.221 & 471.025 | | | | PLEASE REMOVE THE SHEETS FROM THE PLANS | | THAT ARE BEING REVISED,AND INSERT | | REVISED SHEETS. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-04-24 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-02 |
Time |
15:44 |
Rev Time |
0.75 |
Received By |
btrobaug |
Date |
2003-04-24 |
Time |
13:11 |
Sent To |
P |
|
Notes |
2003-04-24 00:00:00 | UNSAT | | ~~~~~ | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | PLEASE PROVIDE LOAD CALCS AND PANEL | | SCHEDULES PER 215-5. | | | | NOTE: PLEASE SHOW ALL OUTLET SPACING | | TO MEET 2',6',12' RULE PER 210-52. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2003-09-29 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-29 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-29 |
Time |
11:35 |
Sent To |
B |
|
Notes |
2003-09-29 00:00:00 | TO ST DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2003-08-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-19 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-08-19 |
Time |
15:13 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2003-07-24 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-24 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-24 |
Time |
16:16 |
Sent To |
B |
|
Notes |
2003-07-24 00:00:00 | TO STHYNG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2003-07-10 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-10 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-10 |
Time |
15:56 |
Sent To |
E |
|
Notes |
2003-07-10 00:00:00 | BT DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-07-07 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-07 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-07 |
Time |
15:26 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-06-25 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-25 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-25 |
Time |
14:52 |
Sent To |
E |
|
Notes |
2003-06-25 00:00:00 | BT DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-06-02 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-02 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-02 |
Time |
15:44 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-04-23 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-23 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-23 |
Time |
10:07 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-04-16 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-16 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-16 |
Time |
10:45 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
N |
Date |
2003-08-27 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-08-27 |
Time |
08:16 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-08-27 |
Time |
08:16 |
Sent To |
B |
|
Notes |
2003-08-27 00:00:00 | RELOCATING C.U. - NO OTHER MECHANICAL | | WORK SHOWN ON THE PLAN. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2003-08-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-08-25 |
Time |
09:08 |
Rev Time |
0.15 |
Received By |
pkrauss |
Date |
2003-08-12 |
Time |
07:39 |
Sent To |
P |
|
Notes |
2003-08-12 00:00:00 | RELOCATING C.U. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-06-10 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-07-28 |
Time |
14:19 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-06-10 |
Time |
11:10 |
Sent To |
B |
|
Notes |
2003-06-10 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR REVIEW | | A COMPLETED FORM 600C & MANUAL J CALCS | | WERE SUBMITTED.EQUIPMENT TO BE | | INSTALLED - RUUD COND MODEL UAMB018JAB, | | AHU UBHC14J06SFEAI, 5KW HEAT |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-04-30 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-06-09 |
Time |
09:00 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2003-04-30 |
Time |
11:31 |
Sent To |
B |
|
Notes |
2003-04-30 00:00:00 | DENIED: | | | | 1.PLEASE PROVIDE COMPLETED FORM 600C, | | AS PER 2001 FBC(M) CHAPTER 13 | | SUB-CHAPTER 600, METHOD C. | | | | 2.PLAN SHEET SEM-1 INDICATES NEW AHU, | | PROVIDE EQUIPMENT INFORMAITON (MODEL, | | BTU OF AHU & SEER OF C.U.). | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
P |
Date |
2003-08-25 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-08-25 |
Time |
09:07 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-08-25 |
Time |
09:06 |
Sent To |
M |
|
Notes |
2003-08-25 00:00:00 | REVISION OK - SANT. RISER DIAGRAM - | | CHANGED FLOOR PLAN. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2003-08-13 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-19 |
Time |
15:13 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-08-13 |
Time |
13:15 |
Sent To |
M |
|
Notes |
2003-08-13 00:00:00 | DENIED | | REFERENCE: FLORIDA STATUTES | | | | 1) 61G1-16.004 TITLE BLOCK REQUIRED ON | | ALL ARCHITECTURAL DRAWS ECT. SEE ATTACH- | | ED SHEET FOR REQUIREMENTS. | | 2) WASH MACHINE SHALL NOT DRAIN INTO THE | | WET VENT OF THE BATHROOM GROUP. SECTION | | 909.1. WASH MACHINE SHALL CONNECT DOWN- | | STREAM OF THE BATHROOM GROUP. SEE RED | | LINE CORRECTIONS. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2003-07-07 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-08-12 |
Time |
07:39 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2003-07-07 |
Time |
18:26 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2003-06-30 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-07 |
Time |
15:26 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2003-06-30 |
Time |
12:35 |
Sent To |
B |
|
Notes |
2003-06-30 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | | | 1) CALCULATIONS FOR PRIMARY AND SECOND- | | ARY ROOF DRAINS INSUFFICIENT. SUBMIT | | CALCULATIONS SHOWING SQUARE FOOTAGE FOR | | THE FLAT ROOF. SHOW 1/2 AREA OF ALL | | VERTICAL WALLS INCLUDING PARAPTES. SHOW | | SQUARE FOOTAGE FOR ALL ROOF AREA THAT | | DRAINS TO FLAT ROOF FROM ABOVE. 1106.2 | | 1106.4 - SECTION 1106.6 | | 2) SECONDARY DRAIN SHALL BE SIZED PER | | SEC 1107.3. THE MINIMUM CROSS-SECTIONAL | | AREA OF AN OVERFLOW SCUPPER SHALL BE 3 | | TIMES THE CROSS-SECTIONAL AREA OF THE | | PRIMARY ROOF DRAIN AND THE SCUPPER SHALL | | HAVE A MINIMUM OPENING DIMENSION OF 4" | | 3) SCUPPER OPENINGS SHALL BE LARGE | | ENOUGH FOR COMBINED AREA OF PRIMARY AND | | SECONDARY DRAINS, (SCUPPERS). SUBMIT A | | DETAIL FOR SCUPPER OPENING SHOWING WIDTH | | AND HEIGHT OF OPENING. SECION 104.2.1 | | 4) THIS IS THE THIRD REJECTION OF THIS | | PLAN FOR THE SAME REASON - PLEASE SEE | | ATTACHED SHEET CONCERNING FLORIDA STATU- | | TE 553.80(2)(B) | | 5) THE INFORMATION SUBMITTED IS THE RE- | | SULT OF THE CALCULATIONS, BUT NOT THE | | ACTUAL CALCULATIONS. | | ********WHEN RESUBMITTING PLANS********* | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-06-09 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-06-09 |
Time |
08:37 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-06-09 |
Time |
08:37 |
Sent To |
M |
|
Notes |
2003-06-09 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FLORIDA STATUTES | | | | 1) CALCULATIONS FOR PRIMARY AND SECOND- | | ARY ROOF DRAINS SHALL SHOW TOTAL SQUARE | | FEET BEING DRAINED. CALCULATIONS SHALL | | SHOW 1/2 AREA OF ALL VERTICAL WALLS, | | (1106.4), ALL AREA OF ALL ROOFS THAT | | DRAIN TO ROOF FROM ABOVE, (1106.2). | | SECTION 104.2.1. GUTTERS SHALL BE SIZED | | PER TABLE 1106.6 FOR PRIMARY DRAIN ONLY. | | 2) SECONDARY DRAIN SHALL BE SIZED PER | | SECTION 1107.3. THE MINIMUM CROSS-SECT- | | IONAL AREA OF AN OVERFLOW SCUPPER SHALL | | BE THREE TIMES THE CROSS-SECTIONAL AREA | | OF THE PRIMARY ROOF DRAIN AND THE SCUPP- | | ER SHALL HAVE A MINIMUM OPENING DIMEN- | | SION OF 4 INCHES. | | 3) SCUPPER OPENINGS SHALL BE LARGE | | ENOUGH FOR COMBINED AREA OF PRIMARY AND | | SECONDARY DRAINS, (SCUPPERS). PLEASE | | SUBMIT A DETAIL FOR SCUPPER OPENING, | | SHOWING WIDTH AND HEIGHT OF OPENING. | | SECTION 104.2.1 | | 4) THE PERSONAL SEAL, SIGNATURE AND DATE | | OF THE ARCHITECT SHALL APPEAR ON ALL | | ARCHITECTURAL DOCUMENTS TO BE FILED FOR | | PUBLIC RECORD. 61G1-16.003 | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-04-24 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-06-03 |
Time |
12:44 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-04-24 |
Time |
14:50 |
Sent To |
M |
|
Notes |
2003-04-24 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | | | 1) SHT A-3 PLEASE SUBMIT CALCULATIONS | | FOR PRIMARY AND SECONDARY ROOF DRAINS | | FOR FLAT ROOFS. OPENINGS FOR DOWNSPOUTS | | SHALL BE SIZED FOR BOTH PRIMARY AND | | SECONDARY DRAINS. | | SHOW 1/2 AREA OF ALL VERTICAL WALLS IN- | | CLUDING PARAPETS. SHOW AREA OF ROOFS | | THAT DRAIN ONTO FLAT ROOF FROM ABOVE. | | SEE SECTIONS 1106 AND 1107 AND ALL SUB- | | SECTIONS. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2003-10-06 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-10-06 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
B |
|
Notes |
2003-10-06 00:00:00 | 10/6/03 GIVEN TO SAMATHA T MM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-04-24 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-10-03 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|