Plan Review Stops For Permit 03041050 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-06-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-01 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-06-24 |
Time |
09:58 |
Sent To |
|
|
Notes |
2003-06-24 00:00:00 | *** PROVISO *** | | | | | | | | THE ENERGY CODE CALCULATIONS MUST BE | | SIGNED, SEALED AND DATED BY THE | | PREPARER AND THE SIGNATURE AND | | REGISTRATION NUMBER OF THE OTHER DESIGN | | PROFESSIONALS MUST BE ON ALL OF THE | | FORMS ALSO.PLEASE COORDINATE THIS AND | | RESUBMIT TO THE CITY. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-05-29 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-23 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-05-29 |
Time |
10:14 |
Sent To |
|
|
Notes |
2003-05-29 00:00:00 | PROVISO: | | 1 PAY IMPACT FEES | | | | 2 RESIDENT INSPECTOR REQUIRED | | | | 3 PROVIDE NEW AND/OR REVISED SOIL REPORT | | AS STATED IN ARCHITECT'S RESPONSE LETTER | | DATED 5/22/03 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-05-02 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-05-02 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-05-02 |
Time |
11:29 |
Sent To |
|
|
Notes |
2003-05-02 00:00:00 | THIS BUILDING WILL REQUIRE A RESIDENT | | INSPECTOR AS PROVIDED FOR IN FBC 105.3 | | AS AMENDED BY THE CITY OF WEST PALM | | BEACH. PLEASE CONTACT DON NEELY AT | | 561-805-6665 FOR MORE INFORMATION. | | | | STAIR #1 DOES NOT COMPLY WITH FBC 1010.1 | | SEE ALSO FBC 1010.3 #1. | | | | THE FOAM TRIM SHOWN AT THE TO OF THE | | PARAPET WALLS ON SHEET A7 AND ELSEWHERE | | DOES NOT COMPLY WITH FBC 1404.1.1. | | | | PLEASE PROVIDE SPECIFIC CONSTRUCTION | | DETAILS FOR THE LOBBY SOFFIT AND | | SIMILAR AS SHOWN ON SHEET A-11 "FASTEN | | TO THE STRUCTURE ABOVE"SEE FBC 104.2. | | | | SHEET S1 CALLS FOR A SOIL BEARING VALUE | | 4 KSF AND THE ALTERRA E&T REPORT IS | | RECOMMENDING 2.5 KSF.PLEASE CLARIFY. | | | | IF TEST AND/OR NOTICE OF ACCEPTANCE | | REPORTS FOR THE DOORS, WINDOWS AND ROOF | | COVERING ARE NOT INCLUDED WITH THIS | | PERMIT APPLICATION, A SEPARATE PERMIT | | AND FEES WILL BE REQUIRED. | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | ISSUED IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY THE PERMIT PLANS STAMPED | | BY THAT OFFICE AND A COPY OF THE PAID | | RECEIPT ATTACHED TO THE PERMIT | | APPLICATION.CALL 561-233-5025 FOR | | MORE INFORMATION. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-05-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-05-06 |
Time |
15:18 |
Rev Time |
1.50 |
Received By |
dpalmer |
Date |
2003-05-06 |
Time |
13:19 |
Sent To |
|
|
Notes |
2003-05-06 00:00:00 | ******** NOTE ********** | | | | ELECTRICAL PLANS PASSED PENDING FIRE | | REVIEW COMMENTS. | | PLEASE SEE MAIN #3 SHOWN AS MAIN #4 ON | | LOAD SUMMARY. | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2003-04-28 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2003-04-28 |
Time |
10:48 |
Rev Time |
0.50 |
Received By |
mamini |
Date |
2003-04-28 |
Time |
10:48 |
Sent To |
|
|
Notes |
2003-04-28 00:00:00 | PASSED: | | 1. SEE# 03042027 FOR UNDERGROUND | | UTILITIES AND CIVIL/SITE WORK PERMIT. | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2003-04-17 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2003-04-17 |
Time |
10:24 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2003-04-17 |
Time |
10:24 |
Sent To |
|
|
Notes |
2003-04-17 00:00:00 | FAILED: | | 1. PLEASE PROVIDE STORM WATER CALC. FOR | | THIS PHASE. | | 2. PLEASE PROVIDE A COPY OF MODIFIED | | SFWMD PERMIT FOR THIS PHASE. | | 3. PLEASE INCLUDE POLLUTION/ EROSION | | PLAN, NOTE TO GC, DETAILS, ETC.. | | 4. PLEASE SUBMIT APPROVAL FROM PUBLIC | | UTILITIES ENGINEERING SERVICES FOR THE | | CONNECTIONS TO CITY SERVICES. | | 5. PLEASE NOTE THAT A SEPARATE PERMIT | | APPLICATION AND FEES FOR UNDERGROUND | | UTILITIES AND SITE WORK WILL BE REQUIRED | | IF ANY QUESTION PLEASE CONTACT 659-8096 | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2003-06-09 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2003-06-09 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-06-09 |
Time |
15:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2003-05-14 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2003-05-14 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-05-14 |
Time |
15:23 |
Sent To |
|
|
Notes |
2003-05-14 00:00:00 | 1) DOORS HARDWARE AND NOTES ON SHEET A-1 | | NOTE #6 AND #7, PLEASE REF NFPA 101 | | CH 38 AND CH 7. | | | | 2) SEPARATE PERMIT APPLICATION AND FEES | | FOR FIRE SPRINKLER AND FIRE ALARM SYSTEM | | WILL BE REQUIRED. | | | | NATE MCCRAY, CAPTAIN | | 659-8096, EXT 8497 | | 805-6722 OR 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-10-01 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-01 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-01 |
Time |
15:00 |
Sent To |
B |
|
Notes |
2003-10-01 00:00:00 | TO HP DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-06-23 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-23 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-23 |
Time |
15:59 |
Sent To |
B |
|
Notes |
2003-06-23 00:00:00 | HP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-06-23 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-23 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-23 |
Time |
15:27 |
Sent To |
B |
|
Notes |
2003-06-23 00:00:00 | HP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-05-27 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-27 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-27 |
Time |
16:33 |
Sent To |
|
|
Notes |
2003-05-27 00:00:00 | COMM BOARD #43 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-04-15 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-05-09 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-15 |
Time |
09:18 |
Sent To |
|
|
Notes |
2003-04-15 00:00:00 | COMM BOARD #18 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-05-10 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-05-10 |
Time |
12:48 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2003-05-10 |
Time |
12:26 |
Sent To |
|
|
Notes |
2003-05-10 00:00:00 | MECHANICAL PERMIT 03041055 | | | | APPROVAL FOR THE HVAC FOR COMMON AREAS | | (CORRIDORS, RESTROOMS & LOBBY). |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-06-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-06-12 |
Time |
13:46 |
Rev Time |
3.00 |
Received By |
kstevens |
Date |
2003-06-12 |
Time |
13:46 |
Sent To |
|
|
Notes |
2003-06-12 00:00:00 | PASSED/PROVISO | | | | SCUPPERS SHALL BE LOCATED 2" TO 4" FROM | | ROOF TO FLOW LINE. 1503.4.2 (SHT A-3) | | | | ALL WATER HAMMER ARRESTORS SHALL BE | | LOCATED NEAR THE FIXTURE PER PDI-WH 201 | | & MANUF. INSTALLATION INSTRUCTIONS. | | (SHT P-5) |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-05-15 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-05-15 |
Time |
09:55 |
Rev Time |
3.50 |
Received By |
kstevens |
Date |
2003-05-14 |
Time |
18:56 |
Sent To |
|
|
Notes |
2003-05-15 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) SHT A-3 DETAIL #9 SCUPPER DETAIL, | | PLEASE INDICATE THE HEIGHT OF THE | | OPENING FOR THE SCUPPER. | | 2) SHT A-3 PLEASE PROVIDE CALCULATIONS | | FOR PRIMARY AND SECONDARY ROOF DRAINS, | | (SCUPPERS). PLEASE SHOW 1/2 AREA OF ALL | | VERTICAL WALLS IN CALCS. AND TOTAL ROOF | | AREA DRAINED. SECTION 1106 & 1107 | | 3) SHT P-1 NOTES #7 & 26, P/T LINE SHALL | | NOT RUN UNDERGROUND THEN RISE UP 6" | | ABOVE GRADE. THIS WILL TRAP THE RELIEF | | LINE. SEC 504.7.1 | | 4) SHT P-4 THERMAL EXPANSION CONTROL IS | | REQUIRED. SECTION 607.3.2 | | 5) SHTS P-1 & P-5 (SANT. RISER DIAGRAM) | | MINIMUM DISTANCE FOR CLEANOUTS IS 100'. | | SEC 708.3.1. CLEANOUTS SHALL BE INSTALL- | | ED AT EACH CHANGE OF DIRECTION GREATER | | THAN 45 DEGREES. SECTION 708.3.3 | | 6) SHT P-5 WATER RISER DIAGRAM, AIR | | CHAMBERS NOT APPROVED. WATER HAMMER | | ARRESTORS REQUIRED BY 604.9 SHALL BE | | LOCATED NEAR THE FIXTURE IN AN "EFFECT- | | IVE RANGE" NOT IN THE CEILING. PDI-WH | | 201 AND MANUF INSTALLATION INSTRUCTIONS. | | 7) SHT P-6 PLUMBING SPECIFICATIONS, | | #3 AIR CHAMBERS ARE NOT APPROVED. PLEASE | | DELETE REFERENCE. | | #11 2-1/2" PIPE AND SMALLER SHALL BE | | SLOPED AT 1/4" PER FOOT. TABLE 704.1 | | 8) SITE ENGINEERING PLANS REFER TO IRRI- | | GATION PLANS. PLANS NOT FOUND. SEPARATE | | PERMIT - PLANS FOR IRRIGATION REQUIRED. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-05-09 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-05-09 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|