Plan Review Details - Permit 03041050
Plan Review Stops For Permit 03041050
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-06-24 Cont ID  
Sent By csiegber Date 2003-10-01 Time 15:00 Rev Time 0.00
Received By hpiskura Date 2003-06-24 Time 09:58 Sent To  
Notes
2003-06-24 00:00:00*** PROVISO ***
  
  
  
 THE ENERGY CODE CALCULATIONS MUST BE
 SIGNED, SEALED AND DATED BY THE
 PREPARER AND THE SIGNATURE AND
 REGISTRATION NUMBER OF THE OTHER DESIGN
 PROFESSIONALS MUST BE ON ALL OF THE
 FORMS ALSO.PLEASE COORDINATE THIS AND
 RESUBMIT TO THE CITY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-05-29 Cont ID  
Sent By shernand Date 2003-06-23 Time 16:00 Rev Time 0.00
Received By hpiskura Date 2003-05-29 Time 10:14 Sent To  
Notes
2003-05-29 00:00:00PROVISO:
 1 PAY IMPACT FEES
  
 2 RESIDENT INSPECTOR REQUIRED
  
 3 PROVIDE NEW AND/OR REVISED SOIL REPORT
 AS STATED IN ARCHITECT'S RESPONSE LETTER
 DATED 5/22/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-02 Cont ID  
Sent By hpiskura Date 2003-05-02 Time 11:29 Rev Time 0.00
Received By hpiskura Date 2003-05-02 Time 11:29 Sent To  
Notes
2003-05-02 00:00:00THIS BUILDING WILL REQUIRE A RESIDENT
 INSPECTOR AS PROVIDED FOR IN FBC 105.3
 AS AMENDED BY THE CITY OF WEST PALM
 BEACH. PLEASE CONTACT DON NEELY AT
 561-805-6665 FOR MORE INFORMATION.
  
 STAIR #1 DOES NOT COMPLY WITH FBC 1010.1
 SEE ALSO FBC 1010.3 #1.
  
 THE FOAM TRIM SHOWN AT THE TO OF THE
 PARAPET WALLS ON SHEET A7 AND ELSEWHERE
 DOES NOT COMPLY WITH FBC 1404.1.1.
  
 PLEASE PROVIDE SPECIFIC CONSTRUCTION
 DETAILS FOR THE LOBBY SOFFIT AND
 SIMILAR AS SHOWN ON SHEET A-11 "FASTEN
 TO THE STRUCTURE ABOVE"SEE FBC 104.2.
  
 SHEET S1 CALLS FOR A SOIL BEARING VALUE
 4 KSF AND THE ALTERRA E&T REPORT IS
 RECOMMENDING 2.5 KSF.PLEASE CLARIFY.
  
 IF TEST AND/OR NOTICE OF ACCEPTANCE
 REPORTS FOR THE DOORS, WINDOWS AND ROOF
 COVERING ARE NOT INCLUDED WITH THIS
 PERMIT APPLICATION, A SEPARATE PERMIT
 AND FEES WILL BE REQUIRED.
  
 BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY THE PERMIT PLANS STAMPED
 BY THAT OFFICE AND A COPY OF THE PAID
 RECEIPT ATTACHED TO THE PERMIT
 APPLICATION.CALL 561-233-5025 FOR
 MORE INFORMATION.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-06 Cont ID  
Sent By dpalmer Date 2003-05-06 Time 15:18 Rev Time 1.50
Received By dpalmer Date 2003-05-06 Time 13:19 Sent To  
Notes
2003-05-06 00:00:00******** NOTE **********
  
 ELECTRICAL PLANS PASSED PENDING FIRE
 REVIEW COMMENTS.
 PLEASE SEE MAIN #3 SHOWN AS MAIN #4 ON
 LOAD SUMMARY.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2003-04-28 Cont ID  
Sent By mamini Date 2003-04-28 Time 10:48 Rev Time 0.50
Received By mamini Date 2003-04-28 Time 10:48 Sent To  
Notes
2003-04-28 00:00:00PASSED:
 1. SEE# 03042027 FOR UNDERGROUND
 UTILITIES AND CIVIL/SITE WORK PERMIT.
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2003-04-17 Cont ID  
Sent By mamini Date 2003-04-17 Time 10:24 Rev Time 1.00
Received By mamini Date 2003-04-17 Time 10:24 Sent To  
Notes
2003-04-17 00:00:00FAILED:
 1. PLEASE PROVIDE STORM WATER CALC. FOR
 THIS PHASE.
 2. PLEASE PROVIDE A COPY OF MODIFIED
 SFWMD PERMIT FOR THIS PHASE.
 3. PLEASE INCLUDE POLLUTION/ EROSION
 PLAN, NOTE TO GC, DETAILS, ETC..
 4. PLEASE SUBMIT APPROVAL FROM PUBLIC
 UTILITIES ENGINEERING SERVICES FOR THE
 CONNECTIONS TO CITY SERVICES.
 5. PLEASE NOTE THAT A SEPARATE PERMIT
 APPLICATION AND FEES FOR UNDERGROUND
 UTILITIES AND SITE WORK WILL BE REQUIRED
 IF ANY QUESTION PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-06-09 Cont ID  
Sent By nmccray Date 2003-06-09 Time 15:21 Rev Time 0.00
Received By nmccray Date 2003-06-09 Time 15:21 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-05-14 Cont ID  
Sent By nmccray Date 2003-05-14 Time 15:23 Rev Time 0.00
Received By nmccray Date 2003-05-14 Time 15:23 Sent To  
Notes
2003-05-14 00:00:001) DOORS HARDWARE AND NOTES ON SHEET A-1
 NOTE #6 AND #7, PLEASE REF NFPA 101
 CH 38 AND CH 7.
  
 2) SEPARATE PERMIT APPLICATION AND FEES
 FOR FIRE SPRINKLER AND FIRE ALARM SYSTEM
 WILL BE REQUIRED.
  
 NATE MCCRAY, CAPTAIN
 659-8096, EXT 8497
 805-6722 OR 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-10-01 Cont ID  
Sent By csiegber Date 2003-10-01 Time 15:00 Rev Time 0.00
Received By csiegber Date 2003-10-01 Time 15:00 Sent To B
Notes
2003-10-01 00:00:00TO HP DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-06-23 Cont ID  
Sent By shernand Date 2003-06-23 Time 15:59 Rev Time 0.00
Received By shernand Date 2003-06-23 Time 15:59 Sent To B
Notes
2003-06-23 00:00:00HP DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-06-23 Cont ID  
Sent By shernand Date 2003-06-23 Time 15:27 Rev Time 0.00
Received By shernand Date 2003-06-23 Time 15:27 Sent To B
Notes
2003-06-23 00:00:00HP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-27 Time 16:33 Rev Time 0.00
Received By shernand Date 2003-05-27 Time 16:33 Sent To  
Notes
2003-05-27 00:00:00COMM BOARD #43

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-15 Cont ID  
Sent By sgraham Date 2003-05-09 Time 14:13 Rev Time 0.00
Received By shernand Date 2003-04-15 Time 09:18 Sent To  
Notes
2003-04-15 00:00:00COMM BOARD #18

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-10 Cont ID  
Sent By pkrauss Date 2003-05-10 Time 12:48 Rev Time 0.55
Received By pkrauss Date 2003-05-10 Time 12:26 Sent To  
Notes
2003-05-10 00:00:00MECHANICAL PERMIT 03041055
  
 APPROVAL FOR THE HVAC FOR COMMON AREAS
 (CORRIDORS, RESTROOMS & LOBBY).

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-06-12 Cont ID  
Sent By kstevens Date 2003-06-12 Time 13:46 Rev Time 3.00
Received By kstevens Date 2003-06-12 Time 13:46 Sent To  
Notes
2003-06-12 00:00:00PASSED/PROVISO
  
 SCUPPERS SHALL BE LOCATED 2" TO 4" FROM
 ROOF TO FLOW LINE. 1503.4.2 (SHT A-3)
  
 ALL WATER HAMMER ARRESTORS SHALL BE
 LOCATED NEAR THE FIXTURE PER PDI-WH 201
 & MANUF. INSTALLATION INSTRUCTIONS.
 (SHT P-5)

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-05-15 Cont ID  
Sent By kstevens Date 2003-05-15 Time 09:55 Rev Time 3.50
Received By kstevens Date 2003-05-14 Time 18:56 Sent To  
Notes
2003-05-15 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) SHT A-3 DETAIL #9 SCUPPER DETAIL,
 PLEASE INDICATE THE HEIGHT OF THE
 OPENING FOR THE SCUPPER.
 2) SHT A-3 PLEASE PROVIDE CALCULATIONS
 FOR PRIMARY AND SECONDARY ROOF DRAINS,
 (SCUPPERS). PLEASE SHOW 1/2 AREA OF ALL
 VERTICAL WALLS IN CALCS. AND TOTAL ROOF
 AREA DRAINED. SECTION 1106 & 1107
 3) SHT P-1 NOTES #7 & 26, P/T LINE SHALL
 NOT RUN UNDERGROUND THEN RISE UP 6"
 ABOVE GRADE. THIS WILL TRAP THE RELIEF
 LINE. SEC 504.7.1
 4) SHT P-4 THERMAL EXPANSION CONTROL IS
 REQUIRED. SECTION 607.3.2
 5) SHTS P-1 & P-5 (SANT. RISER DIAGRAM)
 MINIMUM DISTANCE FOR CLEANOUTS IS 100'.
 SEC 708.3.1. CLEANOUTS SHALL BE INSTALL-
 ED AT EACH CHANGE OF DIRECTION GREATER
 THAN 45 DEGREES. SECTION 708.3.3
 6) SHT P-5 WATER RISER DIAGRAM, AIR
 CHAMBERS NOT APPROVED. WATER HAMMER
 ARRESTORS REQUIRED BY 604.9 SHALL BE
 LOCATED NEAR THE FIXTURE IN AN "EFFECT-
 IVE RANGE" NOT IN THE CEILING. PDI-WH
 201 AND MANUF INSTALLATION INSTRUCTIONS.
 7) SHT P-6 PLUMBING SPECIFICATIONS,
 #3 AIR CHAMBERS ARE NOT APPROVED. PLEASE
 DELETE REFERENCE.
 #11 2-1/2" PIPE AND SMALLER SHALL BE
 SLOPED AT 1/4" PER FOOT. TABLE 704.1
 8) SITE ENGINEERING PLANS REFER TO IRRI-
 GATION PLANS. PLANS NOT FOUND. SEPARATE
 PERMIT - PLANS FOR IRRIGATION REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-09 Cont ID  
Sent By sgraham Date 2003-05-09 Time 14:13 Rev Time 0.00
Received By sgraham Date   Time   Sent To I
Notes
***NONE***