Plan Review Details - Permit 03040924
Plan Review Stops For Permit 03040924
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-06-17 Cont ID  
Sent By sthyng Date 2003-06-17 Time 09:27 Rev Time 1.50
Received By sthyng Date 2003-06-17 Time 08:16 Sent To  
Notes
2003-06-17 00:00:00******PROVISO******
 SUBMIT A REVISION FOR SHEET
 A5 USING 2003 CONNECTORS
 CATALOG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-15 Cont ID  
Sent By pkrauss Date 2003-06-16 Time 07:25 Rev Time 4.00
Received By sthyng Date 2003-05-15 Time 09:08 Sent To  
Notes
2003-05-15 00:00:00******CORRECTIONS********
  
 1.)THE OWNER ON THE APPLICATION IS
 INCORRECT.
  
 2.)ADDITIONAL FEES REQUIRED; $28.12.
  
 3.)A NOTICE OF COMMENCEMENT IS
 REQUIRED TO BE FILED WITH THE CLERK OF
 COURTS BEFORE A PERMIT CAN BE ISSUED.
  
 4.)PROVIDE A HURRICANE SHUTTER
 INSTALLATION SCHEDULE.
  
 5.)PROVIDE A PRODUCT APPROVAL FOR THE
 FRONT DOOR.THIS DOOR MUST EITHER BE
 IMPACT OR HAVE SHUTTERS WHICH CAN BE
 INSTALLED/REMOVED FROM THE INSIDE.
  
 6.)PROVIDE A DETAIL FOR THE OPTIONAL
 30" HIGH GARDEN WALL ON SHEET A2.
  
 7.)DRAFTSTOPPING REQUIRED 705.3.
  
 8.)PROVIDE PRODUCT APPROVALS FOR THE
 WINDOWS, GARAGE DOORS, ROOF, HURRICANE
 SHUTTERS.
  
 9.)PROVIDE A SOILS BEARING REPORT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-12-03 Cont ID  
Sent By btrobaug Date 2003-12-03 Time 12:05 Rev Time 0.50
Received By btrobaug Date 2003-12-03 Time 11:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-05-21 Cont ID  
Sent By btrobaug Date 2003-05-21 Time 15:00 Rev Time 0.50
Received By btrobaug Date 2003-05-21 Time 14:52 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-04-23 Cont ID  
Sent By shernand Date 2003-05-21 Time 14:31 Rev Time 0.50
Received By btrobaug Date 2003-04-23 Time 18:59 Sent To M
Notes
2003-04-23 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE CORRECT THE FOLLOWING ITEMS ON
 THE PLAN AND RESUBMIT FOR REVIEW.
  
 1} THE #2 FEEDERS TO PANEL "A" ARE
 INCORRECT FOR A 200AMP OCP.
  
 2} THE GEC MUST COMPLY WITH 250-24(A)(1)
 AND NOT BE INSTALLED PAST THE FIRST
 MEANS OF DISCONNECT.
  
 3} THE FEEDER SIZE TO PANEL "B" ON RISER
 DIAGRAM AND ON THE PANEL SCHEDULE ARE
 NOT THE SAME,PLEASE CORRELATE.
  
 4} THE CALCULATION FOR PANEL "B" ON
 PANEL "A" SCHEDULE AND ON PANEL "B"
 SCHEDULE DO NOT CORRELATE.
  
 5} THERE IS NO LOAD GIVEN FOR THE
 GARBAGE DISPOSAL IN THE CALCS,PLEASE
 INCLUDE SAME AND CORRECT THE CALCS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-01 Cont ID  
Sent By csiegber Date 2003-10-01 Time 14:48 Rev Time 0.00
Received By csiegber Date 2003-10-01 Time 14:48 Sent To M
Notes
2003-10-01 00:00:00TO PK BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-21 Cont ID  
Sent By shernand Date 2003-05-21 Time 14:31 Rev Time 0.00
Received By shernand Date 2003-05-21 Time 14:31 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-11 Cont ID  
Sent By shernand Date 2003-04-11 Time 14:49 Rev Time 0.00
Received By shernand Date 2003-04-11 Time 14:49 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-10-03 Cont ID  
Sent By pkrauss Date 2003-10-03 Time 06:56 Rev Time 0.25
Received By pkrauss Date 2003-10-03 Time 06:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-06-16 Cont ID  
Sent By csiegber Date 2003-10-01 Time 14:49 Rev Time 0.25
Received By pkrauss Date 2003-06-16 Time 07:25 Sent To P
Notes
2003-06-16 00:00:00MECHANICAL PERMIT 03040929

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-05-05 Cont ID  
Sent By btrobaug Date 2003-05-21 Time 15:00 Rev Time 0.15
Received By pkrauss Date 2003-05-05 Time 08:42 Sent To B
Notes
2003-05-05 00:00:00DENIED:MECHANICAL PERMIT 03040929
  
 PLAN SHEET M-1 MASTER BATHROOM, AS PER
 2001 FBC(M) 402.3.1 & 502.13, ROOMS
 CONTAINING BATHTUBS, SHOWERS, AND
 TOILET ROOMS SHALL HAVE MECHANICAL
 EXHAUST AS PER 2001 FBC(M) 402.3.1 &
 502.13.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-04-23 Cont ID  
Sent By pkrauss Date 2003-06-16 Time 07:28 Rev Time 0.33
Received By jleech Date 2003-04-23 Time 18:29 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-15 Cont ID  
Sent By shernand Date 2003-04-16 Time 14:49 Rev Time 0.00
Received By sthyng Date   Time   Sent To  
Notes
2003-05-15 00:00:00SIGNED OF BY SHIRLEY GRAHAM 4/16/03