Plan Review Stops For Permit 03040924 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-06-17 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-06-17 |
Time |
09:27 |
Rev Time |
1.50 |
Received By |
sthyng |
Date |
2003-06-17 |
Time |
08:16 |
Sent To |
|
|
Notes |
2003-06-17 00:00:00 | ******PROVISO****** | | SUBMIT A REVISION FOR SHEET | | A5 USING 2003 CONNECTORS | | CATALOG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-05-15 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-06-16 |
Time |
07:25 |
Rev Time |
4.00 |
Received By |
sthyng |
Date |
2003-05-15 |
Time |
09:08 |
Sent To |
|
|
Notes |
2003-05-15 00:00:00 | ******CORRECTIONS******** | | | | 1.)THE OWNER ON THE APPLICATION IS | | INCORRECT. | | | | 2.)ADDITIONAL FEES REQUIRED; $28.12. | | | | 3.)A NOTICE OF COMMENCEMENT IS | | REQUIRED TO BE FILED WITH THE CLERK OF | | COURTS BEFORE A PERMIT CAN BE ISSUED. | | | | 4.)PROVIDE A HURRICANE SHUTTER | | INSTALLATION SCHEDULE. | | | | 5.)PROVIDE A PRODUCT APPROVAL FOR THE | | FRONT DOOR.THIS DOOR MUST EITHER BE | | IMPACT OR HAVE SHUTTERS WHICH CAN BE | | INSTALLED/REMOVED FROM THE INSIDE. | | | | 6.)PROVIDE A DETAIL FOR THE OPTIONAL | | 30" HIGH GARDEN WALL ON SHEET A2. | | | | 7.)DRAFTSTOPPING REQUIRED 705.3. | | | | 8.)PROVIDE PRODUCT APPROVALS FOR THE | | WINDOWS, GARAGE DOORS, ROOF, HURRICANE | | SHUTTERS. | | | | 9.)PROVIDE A SOILS BEARING REPORT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-12-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-12-03 |
Time |
12:05 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-12-03 |
Time |
11:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-05-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-05-21 |
Time |
15:00 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-05-21 |
Time |
14:52 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-04-23 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-21 |
Time |
14:31 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-04-23 |
Time |
18:59 |
Sent To |
M |
|
Notes |
2003-04-23 00:00:00 | UNSAT | | ~~~~~ | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | PLEASE CORRECT THE FOLLOWING ITEMS ON | | THE PLAN AND RESUBMIT FOR REVIEW. | | | | 1} THE #2 FEEDERS TO PANEL "A" ARE | | INCORRECT FOR A 200AMP OCP. | | | | 2} THE GEC MUST COMPLY WITH 250-24(A)(1) | | AND NOT BE INSTALLED PAST THE FIRST | | MEANS OF DISCONNECT. | | | | 3} THE FEEDER SIZE TO PANEL "B" ON RISER | | DIAGRAM AND ON THE PANEL SCHEDULE ARE | | NOT THE SAME,PLEASE CORRELATE. | | | | 4} THE CALCULATION FOR PANEL "B" ON | | PANEL "A" SCHEDULE AND ON PANEL "B" | | SCHEDULE DO NOT CORRELATE. | | | | 5} THERE IS NO LOAD GIVEN FOR THE | | GARBAGE DISPOSAL IN THE CALCS,PLEASE | | INCLUDE SAME AND CORRECT THE CALCS. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-10-01 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-01 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-01 |
Time |
14:48 |
Sent To |
M |
|
Notes |
2003-10-01 00:00:00 | TO PK BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-05-21 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-21 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-21 |
Time |
14:31 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-04-11 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-11 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-11 |
Time |
14:49 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2003-10-03 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-10-03 |
Time |
06:56 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-10-03 |
Time |
06:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-06-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-01 |
Time |
14:49 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-06-16 |
Time |
07:25 |
Sent To |
P |
|
Notes |
2003-06-16 00:00:00 | MECHANICAL PERMIT 03040929 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-05-05 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-05-21 |
Time |
15:00 |
Rev Time |
0.15 |
Received By |
pkrauss |
Date |
2003-05-05 |
Time |
08:42 |
Sent To |
B |
|
Notes |
2003-05-05 00:00:00 | DENIED:MECHANICAL PERMIT 03040929 | | | | PLAN SHEET M-1 MASTER BATHROOM, AS PER | | 2001 FBC(M) 402.3.1 & 502.13, ROOMS | | CONTAINING BATHTUBS, SHOWERS, AND | | TOILET ROOMS SHALL HAVE MECHANICAL | | EXHAUST AS PER 2001 FBC(M) 402.3.1 & | | 502.13. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-04-23 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-06-16 |
Time |
07:28 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-04-23 |
Time |
18:29 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-05-15 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-16 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-05-15 00:00:00 | SIGNED OF BY SHIRLEY GRAHAM 4/16/03 |
|
|