Plan Review Details - Permit 03040785
Plan Review Stops For Permit 03040785 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-05-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-05-19 |
Time |
08:00 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2003-05-07 |
Time |
06:42 |
Sent To |
|
|
Notes |
2003-05-07 00:00:00 | BUILDING PROVISO: | | 1609.4.3 LOAD REDUCTION. | | WHEN STRUCTURAL EFFECTS DUE TO TWO OR | | MORE LOADS IN COMBINATION WITH DEAD LOAD | | ARE INVESTIGATED IN LOAD COMBINATIONS OF | | 1609.4.1 OR 1609.4.2, THE COMBINED | | EFFECTS DUE TO THE TWO OR LOADS MULTI- | | PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD | | LOADS SHALL NOT BE LESS THAN THE EFFECTS | | FROM THE LOAD COMBINATION OF THE DEAD | | LOAD PLUS THE LOAD PRODUCING THE LARGEST | | EFFECTS. INCREAS IN ALLOWABLE STRESS SPE | | CIFIED IN THE MATERIALS SECTIONS OF THIS | | CODE OR A REFRENCED STANDARD SHALL NOT | | BE USED WITH THESE LOAD COMBINATIONS | | EXCEPT THAT A DURATION OF LOAD INCREASE | | SHALL BE PERMITTED IN ACCORDANCE WITH | | CHAPTER 23. | | RE-EVALUATE TRUSS ANCHOR SCHEDULE BEFORE | | ROOF FRAMING INSPECTION. | | (561)805-6715 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-05-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-05-19 |
Time |
08:00 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-05-19 |
Time |
07:57 |
Sent To |
B |
|
Notes |
2003-05-19 00:00:00 | ********* NOTES REDLINED *********** | | | | 1)NOTE: PLEASE SEE MISSING RECEPTS | | PER 210-52, BR #3, BR#2 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-04-23 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-16 |
Time |
16:13 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-04-23 |
Time |
17:44 |
Sent To |
M |
|
Notes |
2003-04-23 00:00:00 | UNSAT | | ~~~~~ | | HAND DRAWN CHANGES TO PLANS ARE NOT | | ACCEPTABLE.RETURN TO ENGINEER OF RECORD | | SO HE CAN MAKE ANY CHANGES,AND RESUBMIT | | FOR REVIEW. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-05-16 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-16 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-16 |
Time |
16:13 |
Sent To |
E |
|
Notes |
2003-05-16 00:00:00 | DP DESK, BT ON VACATION. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-04-11 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-11 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-11 |
Time |
09:17 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-04-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-04-23 |
Time |
17:53 |
Rev Time |
0.25 |
Received By |
hmoser |
Date |
2003-04-23 |
Time |
19:42 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-04-21 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-04-21 |
Time |
19:41 |
Rev Time |
0.33 |
Received By |
alange |
Date |
2003-04-21 |
Time |
19:41 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-05-07 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-11 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2003-05-07 |
Time |
06:42 |
Sent To |
|
|
Notes |
2003-05-07 00:00:00 | 4-16-03 OK PER S GRAHAM |
|
|
|