Plan Review Details - Permit 03040611
Plan Review Stops For Permit 03040611
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-06-05 Cont ID  
Sent By jgomez Date 2003-06-05 Time 15:32 Rev Time 2.50
Received By jgomez Date 2003-06-05 Time 15:32 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-12 Cont ID  
Sent By shernand Date 2003-06-03 Time 14:23 Rev Time 4.00
Received By jgomez Date 2003-05-12 Time 09:48 Sent To  
Notes
2003-05-12 00:00:00BUILDING REVIEW CHECKLIST:
 1-PROVIDE IMPACT FEES PAID RECEIPT.
 2-OWNER AND CONTRACTOR INFORMATION DON'T
 MATCH. PERMIT APPLICATION, ENERGY
 CALCULATIONS AND INFORMATION FROM PAPA
 IS DIFFERENT. CORRECT AS REQUIRED.
 3-SECTION/DETAIL AT GARAGE INTERIOR
 BEARING WALL IS MISSING INFORMATION.
 SEE COMMENTS ON REVIEWED SET.
 4-PROVIDE SOIL TEST REPORT.
 5-REVISE/CLARIFY NOTE #1 ON SHEET A-4.
 HANDRAIL & GUARDRAIL ARE NOT THE SAME.
 SEE SEC. 1007.5.1 FOR HANDRAIL HEIGHT.
 6-REVISE DETAIL 4/S-2 TO MATCH FLOOR
 FRAMING PLAN. COLUMN IS RECEIVING TWO
 GIRDERS, BUT DETAIL ONLY SHOW SUPPORT
 FOR ONE GIRDER. SECTION 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 7-ENERGY CALCULATIONS: A)REVISE OWNER &
 CONTRACTOR INFORMATION. B)COMPLETE
 TOP OF FORM INCLUDING ADDRESS OF HOUSE
 8-SPECIFY CONNECTOR FOR TRUSS ON DETAIL
 1/S-2. SEC. 104.2.1.2 CITY AMENDMENTS.
 9-CLARIFY DETAIL C/S-2. HOW IS THIS
 BUCKET ATTACHED TO THE CORNER OF NOOK
 AREA WALL. PROVIDE DETAIL SHOWING THE
 EDGE OF THE WALL AND THE CLEARANCES.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 10-REVISE DETAIL E/S-3 SPECIFIED ON ROOF
 PLAN ABOVE MASTER BEDROOM. THIS IS
 MASONRY CONSTRUCTION NOT WOOD FRAME.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 11-SHEET A-4: CLARIFY EXTERIOR STUCCO
 SOFFIT SPECIFICATIONS NOTES. SOME ARE
 REPETITIVE AND SOME ARE MISSING INFO.
 SEE ASTM C-1063 AND PROVIDE CLEAR
 SPECIFICATIONS WITH SIZE OF FASTENER
 AND SPACING. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 12-SHEET A-5. WOOD FRAME TO CONCRETE
 WALL CONNECTION DETAIL: A)MISSING HOW
 MUCH EMBEDMENT FOR ANCHORS.B)UPDATE
 SEMCO CONNECTOR. SECTION 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 13-2ND FLOOR FRAMING PLAN & ROOF FRAMING
 PLAN ARE MISSING SOME CONNECTORS. SEE
 PLANS FOR COMMENTS. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-10-02 Cont ID  
Sent By dpalmer Date 2003-10-02 Time 08:00 Rev Time 0.33
Received By dpalmer Date 2003-10-02 Time 08:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-23 Cont ID  
Sent By csiegber Date 2003-09-23 Time 16:45 Rev Time 0.50
Received By btrobaug Date 2003-04-23 Time 16:20 Sent To M
Notes
2003-04-23 00:00:00REDLINED 220*16 B & 250-66./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-23 Cont ID  
Sent By csiegber Date 2003-09-23 Time 16:45 Rev Time 0.00
Received By csiegber Date 2003-09-23 Time 16:45 Sent To E
Notes
2003-09-23 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-03 Cont ID  
Sent By shernand Date 2003-06-03 Time 14:20 Rev Time 0.00
Received By shernand Date 2003-06-03 Time 14:20 Sent To B
Notes
2003-06-03 00:00:00JGOMEZ DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-10 Cont ID  
Sent By shernand Date 2003-04-10 Time 11:22 Rev Time 0.00
Received By shernand Date 2003-04-10 Time 11:22 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-04-23 Cont ID  
Sent By btrobaug Date 2003-04-23 Time 16:59 Rev Time 0.25
Received By hmoser Date 2003-04-23 Time 19:28 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-04-21 Cont ID  
Sent By alange Date 2003-04-21 Time 18:51 Rev Time 0.33
Received By alange Date 2003-04-21 Time 18:51 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-07 Cont ID  
Sent By shernand Date 2003-04-10 Time 11:22 Rev Time 0.00
Received By shernand Date 2003-05-07 Time 10:09 Sent To B
Notes
2003-05-07 00:00:00PLANS WERE STAMPED AND PASSED BY SHIRLEY
 GRAHAM.