Plan Review Details - Permit 03040610
Plan Review Stops For Permit 03040610
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-05-23 Cont ID  
Sent By shernand Date 2003-05-28 Time 09:16 Rev Time 3.00
Received By rmcdouga Date 2003-05-23 Time 08:51 Sent To  
Notes
2003-05-23 00:00:00BUILDING PROVISO
  
 1) SUBMIT PRODUCT APPROVALS FOR THE
 SINGLE OUTSWING DOOR WITH SIDELITES
 PRIOR TO INSTALLING.
  
 2) PROVIDE A LETTER OR REVISED DRAWING
 FROM THE ARCHITECT ADDRESSING THE UPLIFT
 VALUE FOR THE HTA 16-18 CONNECTOR IN
 DETAIL B ON S2 AND CLARIFICATION OF THE
 CONNECTORS FOR THE TRUSSES OVER THE
 GARAGE BEFORE INSTALLING TRUSSES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-14 Cont ID  
Sent By shernand Date 2003-05-21 Time 12:43 Rev Time 4.00
Received By rmcdouga Date 2003-05-14 Time 11:26 Sent To  
Notes
2003-05-14 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) SUBMIT A COPY OF THE PAID RECEIPT FOR
 THE COUNTY IMPACT FEES.
  
 3) SUBMIT A SOIL BORING TEST REPORT AS
 REQUIRED BY CITY AMEND. TO FBC 1804.2.2.
  
 4) THE INFORMATION ON THE ENERGY CALCS.
 IS INCORRECT. THE CONDITIONED AREA
 LISTED ON THE ENERGY CALC. FORM IS
 2292 SQFT AND THE PLAN LISTS 2260 SQFT.
 THE OWNER AND BUILDER LISTED ON THE FORM
 DOES NOT CORRESPOND TO THE CITY OR
 COUNTY RECORDS. PLEASE CORRECT.
  
 5) REVISE THE STUCCO SPECIFICATIONS ON
 A3 NOTE #7 TO INDICATE THAT 3/8" HIGH
 RIB METAL LATH IS REQUIRED TO BE
 FASTENED AT EVERY RIB (4"O.C.) AS
 REQUIRED BY ASTM C 1063. NOTE #4 AND #5
 ARE THE SAME.
  
 6) SPECIFY THE TRUSS CONNECTORS FOR THE
 LOWER TRUSSES ON THE 10' HT. WOOD FRAME
 BEARING WALL BETWEEN THE ENTRY AND THE
 GALLERY ON SHEET S2.
  
 7) REVISE THE UPLIFT VALUES OF THE USP
 CONNECTORS TO THE VALUES THAT DO NOT
 INCLUDE A STRESS INCREASE ON THE STEEL
 CALCULATIONS. SEE 2003 USP CATALOG.
  
 8) THE OPENING SIZES FOR UNITS #1 AND #2
 ON THE STORM PANEL SCHEDULE ARE REVERSED
 FROM THE KEY PLAN. PLEASE CORRECT.
  
 9) SUBMIT PRODUCT APPROVALS FOR THE
 SINGLE OUTSWING DOOR WITH ONE SIDELITE.
  
 10) SUBMIT AN ADDITIONAL COPY OF THE
 PRODUCT APPROVAL FOR THE SLIDING GLASS
 DOOR.
  
 11) SUBMIT AN ADDITIONAL COPY OF THE
 SURVEY.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-09-02 Cont ID  
Sent By btrobaug Date 2003-09-02 Time 14:41 Rev Time 0.50
Received By btrobaug Date 2003-09-02 Time 14:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-23 Cont ID  
Sent By csiegber Date 2003-08-25 Time 08:28 Rev Time 0.50
Received By btrobaug Date 2003-04-23 Time 19:46 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-08-25 Cont ID  
Sent By csiegber Date 2003-08-25 Time 08:28 Rev Time 0.00
Received By csiegber Date 2003-08-25 Time 08:28 Sent To E
Notes
2003-08-25 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-05-28 Cont ID  
Sent By shernand Date 2003-05-28 Time 09:16 Rev Time 0.00
Received By shernand Date 2003-05-28 Time 09:16 Sent To B
Notes
2003-05-28 00:00:00RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-21 Cont ID  
Sent By shernand Date 2003-05-21 Time 12:42 Rev Time 0.00
Received By shernand Date 2003-05-21 Time 12:42 Sent To B
Notes
2003-05-21 00:00:00RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-15 Cont ID  
Sent By shernand Date 2003-04-15 Time 13:43 Rev Time 0.00
Received By shernand Date 2003-04-15 Time 13:43 Sent To Z
Notes
2003-04-15 00:00:00SUBMITTAL FOR SURVEY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-14 Cont ID  
Sent By shernand Date 2003-04-14 Time 11:14 Rev Time 0.00
Received By shernand Date 2003-04-14 Time 11:14 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-05 Cont ID  
Sent By btrobaug Date 2003-04-23 Time 19:51 Rev Time 0.15
Received By pkrauss Date 2003-05-05 Time 09:09 Sent To B
Notes
2003-05-05 00:00:00MECHANICAL PERMIT 03040711

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-04-21 Cont ID  
Sent By jleech Date 2003-04-21 Time 20:16 Rev Time 0.33
Received By jleech Date 2003-04-21 Time 20:16 Sent To E
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2003-05-29 Cont ID  
Sent By rmcdouga Date 2003-05-29 Time 14:59 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-05-29 00:00:00LETTER FROM ARCHITECT REVISING TRUSS
 CONNECTION DETAIL IS OK.

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-14 Cont ID  
Sent By shernand Date 2003-04-15 Time 13:43 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-05-14 00:00:00OK PER S.GRAHAM 4-16-03