Plan Review Details - Permit 03040607
Plan Review Stops For Permit 03040607
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-05-07 Cont ID  
Sent By rmcdouga Date 2003-05-07 Time 13:48 Rev Time 2.00
Received By rmcdouga Date 2003-05-07 Time 13:48 Sent To  
Notes
2003-05-07 00:00:00BUILDING PROVISO
  
 1) SUBMIT A SOIL BORING TEST REPORT AS
 REQUIRED BY CITY AMENDMENTS TO FBC
 1804.2.2 PRIOR TO POURING FOUNDATION.
  
 2) SUBMIT REVISED UPLIFT VALUES FOR
 FOR TRUSS CONNECTORS THAT DO NOT INCLUDE
 THE ONE-THIRD STRESS INCREASE ON THE
 STEEL CALCULATIONS. SEE FBC 1609.4 AND
 THE 2003 USP CATALOG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-30 Cont ID  
Sent By hmoser Date 2003-04-23 Time 18:39 Rev Time 4.00
Received By rmcdouga Date 2003-04-30 Time 13:39 Sent To  
Notes
2003-04-30 00:00:00BUILDING DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) PROVIDE A SOIL BORING TEST REPORT AS
 REQUIRED BY CITY AMEND. TO FBC 1804.2.2.
  
 4) THE COVERED PATIO SHOWN ON THE
 SURVEY DOES NOT MATCH THE PLANS.
  
 5) SPECIFY THE LENGTH/EMBEDDMENT DEPTH
 OF THE 1/2" DIAMETER EXPANSION ANCHORS
 USED AT THE WOOD FRAME TO CONCRETE WALL
 CONNECTION ON SHEET A6.
  
 6) THE COLUMN SCHEDULE ON S1 SPECIFIES
 TWO (2) 2X4 POST FOR C2. THE NOTE ON
 THE FOUNDATION PLAN AT THE C2 LOCATION
 CALLS FOR A THREE (3) 2X4 WD. POST.
 PLEASE CORRECT.
  
 7)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - SLIDING GLASS DOOR
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-09-02 Cont ID  
Sent By btrobaug Date 2003-09-02 Time 14:48 Rev Time 0.50
Received By btrobaug Date 2003-09-02 Time 14:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-16 Cont ID  
Sent By csiegber Date 2003-08-25 Time 08:30 Rev Time 0.75
Received By btrobaug Date 2003-04-16 Time 11:14 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-25 Cont ID  
Sent By csiegber Date 2003-08-25 Time 08:30 Rev Time 0.00
Received By csiegber Date 2003-08-25 Time 08:30 Sent To E
Notes
2003-08-25 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-09 Cont ID  
Sent By shernand Date 2003-04-09 Time 09:25 Rev Time 0.00
Received By shernand Date 2003-04-09 Time 09:25 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-04-23 Cont ID  
Sent By rmcdouga Date 2003-04-30 Time 12:50 Rev Time 0.50
Received By hmoser Date 2003-04-23 Time 18:38 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-04-30 Cont ID  
Sent By btrobaug Date 2003-04-16 Time 12:17 Rev Time 0.00
Received By rmcdouga Date 2003-04-30 Time 12:50 Sent To M
Notes
2003-04-30 00:00:00OK PER J LEECH 4-21-03

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-07 Cont ID  
Sent By shernand Date 2003-04-09 Time 09:25 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-05-07 00:00:00OK PER S. GRAHAM 4-9-03