Plan Review Details - Permit 03040604
Plan Review Stops For Permit 03040604
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-05-07 Cont ID  
Sent By rmcdouga Date 2003-05-07 Time 15:22 Rev Time 2.00
Received By rmcdouga Date 2003-05-07 Time 15:22 Sent To  
Notes
2003-05-07 00:00:00BUILDING PROVISO
  
 1) SUBMIT A SOIL BORING TEST REPORT AS
 REQUIRED BY CITY AMEND. TO FBC 1804.2.2,
 PRIOR TO POURING THE FOUNDATION.
  
 2) SUBMIT REVISED TRUSS CONNECTOR UPLIFT
 VALUES THAT DO NOT INCLUDE A STRESS
 INCREASE ON THE STEEL CALCULATIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-02 Cont ID  
Sent By hmoser Date 2003-04-23 Time 17:53 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-05-02 00:00:00BUILDING DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) PROVIDE A SOIL BORING TEST REPORT AS
 REQUIRED BY CITY AMEND.TO FBC 1804.2.2.
  
 4) THE COVERED PATIO SHOWN ON THE
 SURVEY DOES NOT MATCH THE PLANS.
  
 5) SPECIFY THE LENGTH/EMBEDMENT DEPTH
 OF THE 1/2" DIAMETER EXPANSION ANCHORS
 USED AT THE WOOD FRAME TO CONCRETE WALL
 CONNECTION ON SHEET A6.
  
 6) THE COLUMN SCHEDULE ON S1 SPECIFIES A
 TWO (2) 2X4 POST FOR C2. THE NOTE ON THE
 FOUNDATION PLAN AT THE C2 LOCATION CALLS
 FOR A THREE (3) 2X4 POST.
 PLEASE CORRECT.
  
 7) STRESS INCREASES FOR SHORT TERM
 LOADING ON STEEL ARE NO LONGER ALLOWED
 TO BE TAKEN BY FBC 1609.4.3. SEE THE
 2003 USP CATALOG FOR LOAD VALUES THAT DO
 NOT INCLUDE A STRESS INCREASE ON THE
 STEEL CALCULATIONS. PLEASE REVISE THE
 CONNECTOR UPLIFT VALUES ACCORDINGLY.
  
 8) NOTE 7 UNDER EXTERIOR SOFFIT SPECS.
 ON A5 DOES NOT INDICATE THAT 3/8" HIGH
 RIB METAL LATH IS REQUIRED TO BE
 FASTENED AT EACH RIB (4"O.C.) PER
 ASTM C 1063. PLEASE CORRECT.
 NOTES 4 AND 5 ARE THE SAME.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-09-02 Cont ID  
Sent By btrobaug Date 2003-09-02 Time 13:59 Rev Time 0.50
Received By btrobaug Date 2003-09-02 Time 13:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-23 Cont ID  
Sent By csiegber Date 2003-08-25 Time 08:27 Rev Time 0.50
Received By btrobaug Date 2003-04-23 Time 15:38 Sent To M
Notes
2003-04-23 00:00:00REDLINED 220-16 B,& 250-66./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-25 Cont ID  
Sent By csiegber Date 2003-08-25 Time 08:27 Rev Time 0.00
Received By csiegber Date 2003-08-25 Time 08:27 Sent To E
Notes
2003-08-25 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-09 Cont ID  
Sent By shernand Date 2003-04-09 Time 09:41 Rev Time 0.00
Received By shernand Date 2003-04-09 Time 09:41 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-04-23 Cont ID  
Sent By btrobaug Date 2003-04-23 Time 15:39 Rev Time 0.50
Received By hmoser Date 2003-04-23 Time 17:53 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-04-21 Cont ID  
Sent By alange Date 2003-04-21 Time 18:52 Rev Time 0.33
Received By alange Date 2003-04-21 Time 18:52 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-09 Cont ID  
Sent By shernand Date 2003-04-09 Time 09:41 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***