Plan Review Stops For Permit 03040129 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2003-07-25 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-07-25 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
2003-11-25 |
Time |
10:32 |
Sent To |
|
|
Notes |
2003-07-25 00:00:00 | RESTAMP | | | | FOR FULL SET OF STAMPS, SEE CITY SET |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-05-30 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-25 |
Time |
08:46 |
Rev Time |
1.00 |
Received By |
sthyng |
Date |
2003-05-30 |
Time |
09:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-05-20 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-29 |
Time |
12:22 |
Rev Time |
1.50 |
Received By |
sthyng |
Date |
2003-05-20 |
Time |
08:47 |
Sent To |
|
|
Notes |
2003-05-20 00:00:00 | *******CORRECTIONS******* | | | | 1.)PROVIDE A SITE SPECIFIC OR A | | PRODUCT APPROVAL FOR THE FRONT DOOR. | | | | 2.)PROVIDE SOILS INVESTIGATION | | REPORT. | | | | 3.)PROVIDE STORM PANEL INSTALLATION | | SCHEDULE, OR APPLY LATER AS A SEPARATE | | PERMIT. | | | | THE ABOVE MAY BE BROUGHT IN AS A | | NO FEE SUBMITTAL. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-05-02 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-14 |
Time |
14:02 |
Rev Time |
6.00 |
Received By |
sthyng |
Date |
2003-04-30 |
Time |
13:20 |
Sent To |
|
|
Notes |
2003-05-02 00:00:00 | **********CORRECTIONS************ | | | | 1.)SITE SPECIFIC PRODUCT APPROVALS | | FOR DOORS CANNOT BE MASTERED.SUBMIT | | A PRODUCT APPROVAL FOR THE FRONT DOOR. | | ALSO NOTE THAT THE SITE SPECIFIC IN | | THE PRODUCT APPROVAL MASTER BOOK DOES | | NOT MATCH THE PRODUCT ON THE PLAN. | | | | 2.)FYI - PRODUCT APPROVAL FOR THE | | MULLIONS EXPIRES 5/1/03. | | | | 3.)KEY NOTE 37 REFERS TO A DETAIL | | NOT ON THE PLAN. | | | | 4.)KEY NOTE 44 REFERS TO A DETAIL NOT | | ON THE PLAN. | | | | 5.)PROVIDE SOILS REPORT. | | | | 6.)A NOTICE OF COMMENCEMENT MUST BE | | FILED WITH THE CLERK OF COURTS BEFORE A | | PERMIT CAN BE ISSUED. | | | | 7.)TRUSS CONNECTOR SCHEDULE A3 REFERS | | TO THE USP 2001 CATALOG.USE THE MOST | | RECENT CATALOG, 2003, WHICH HAS NEW | | UPLIFT VALUES. | | | | 8.)PROVIDE STORM PANEL INSTALLATION | | SCHEDULE. | | | | 9.)ADDITIONAL FEES REQUIRED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-12-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-12-16 |
Time |
13:01 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-12-16 |
Time |
13:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-12-05 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-11 |
Time |
14:48 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-12-05 |
Time |
16:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-04-10 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-04 |
Time |
14:02 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-04-10 |
Time |
05:04 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2003-12-11 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-11 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-11 |
Time |
14:48 |
Sent To |
E |
|
Notes |
2003-12-11 00:00:00 | TO BT DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-12-04 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-04 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-04 |
Time |
14:02 |
Sent To |
E |
|
Notes |
2003-12-04 00:00:00 | TO BT DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-07-25 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-25 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-25 |
Time |
08:46 |
Sent To |
B |
|
Notes |
2003-07-25 00:00:00 | TO STHYNG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-05-29 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-29 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-29 |
Time |
12:22 |
Sent To |
B |
|
Notes |
2003-05-29 00:00:00 | STHYNG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-05-14 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-14 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-14 |
Time |
14:02 |
Sent To |
B |
|
Notes |
2003-05-14 00:00:00 | STHYNG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-03 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-03 |
Time |
09:55 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-04-19 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-04-16 |
Time |
19:52 |
Rev Time |
0.33 |
Received By |
rregueir |
Date |
2003-04-19 |
Time |
13:53 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-04-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-04-10 |
Time |
05:04 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-04-16 |
Time |
19:52 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-03 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
E |
|
Notes |
|
|