Plan Review Stops For Permit 03040061 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-05-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-05-28 |
Time |
11:09 |
Rev Time |
1.25 |
Received By |
jwitmer |
Date |
2003-05-28 |
Time |
11:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-04-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-04-14 |
Time |
13:27 |
Rev Time |
0.88 |
Received By |
jwitmer |
Date |
2003-04-14 |
Time |
13:27 |
Sent To |
|
|
Notes |
2003-04-14 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 03040061 | | ADD: 2316 S DIXIE HWY | | CONT: MIKE MOORE CONST | | TEL: (561)745-1054 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1) WHAT TYPE OF OCCUPANCY IS THIS STRUC- | | TURE TO BE USED FOR? EXITING MERCANTILE | | VS BUSSINESS SEE EXCEPTIONS 1018. | | | | 2)FL BLD CODE 104.2.1.2 | | ADDITIONAL INFORMATION REQUIRED, | | IDENTIFY ROOM USAGE? | | | | 3) TABLE 803.3 MINIMUM INTERIOR FINISH | | CLASSIFICATION; PROVIDE INFORMATION | | BASED ON INTERIOR FINISH REQUIREMENTS | | BASED ON OCCUPANCY. | | | | 4)1511.7 ROOF MOUNTED MECHANICAL UNIT | | S SHALL BE MOUNTED ON CURBS RAISED A | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | HEIGTH IN ACCORDANCE WITH TABLE 1511.7. | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | ON THE APPLICATION, PLANS, OR ATTACHED | | SEPARATELY. WHEN RESUBMITTING PLANS | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | JIM WITMER | | BUILDING PLAN REVIEW | | TEL: (561)659-8096 X 8412 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-05-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-05-16 |
Time |
12:44 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-05-16 |
Time |
12:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-04-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-04-10 |
Time |
06:36 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-04-10 |
Time |
06:36 |
Sent To |
|
|
Notes |
2003-04-10 00:00:00 | ************ UNSAT *************** | | | | 1)NOTE: PLEASE SEE PANEL SCHEDULE, SHOW | | FOUR COND UNITS? PLEASE ALSO SEE OCP | | SHOWN AS 2-P 30A,PLEASE SEE 7.5KW LOAD | | SHOWN FOR AHU/HEAT. PLEASE CORRELATE | | AND SIZE OCP PER 424-3 | | | | 2)NOTE: PLEASE SHOW ALL CIRCUITING ON | | PLANS AND CORRELATE WITH SUBMITTED | | PANEL SCHEDULE. 215-5 | | | | 3)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | AT 125%. 215-3/230-42 ETC. | | | | 4)NOTE: PLEASE CLARIFY NEW OR EXISTING | | SIGN CIRCUIT REQ`D PER 600-5 | | | | 5)NOTE: PLEASE SEE 700-12E FOR CIRCUIT- | | -ING FO EM/EXT LTS. SAME AS GEN LTS. | | | | 6)NOTE: PLEASE CLARIFY/SHOW NEW OR EXIST | | -ING SHOW WINDOW RECEPTS 210-62/220-12 | | | | 7)NOTE: PLEASE SEE SEE SIZE OPENING FOR | | ACCESS TO ELECTRICAL ROOM, @ 1/8 SCALE | | IT APPEARS DOOR IS LESS THAN 2' WIDE? | | 110-26 | | | | 8)NOTE: PLEASE NOTE, MAX OCP FOR WATER | | HEATER CAN NOT EXCEED 150% OF LOAD. | | WATER HEATER IS SHOWN AS HAVING 40A | | OCP.422-11 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 | | [email protected] | | | | 9)NOTE: PLEASE CLARIFY REQ`D ROOFTOP | | RECEPT. 210-63 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2003-05-22 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-05-22 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-05-22 |
Time |
16:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2003-04-11 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-04-11 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-04-11 |
Time |
14:36 |
Sent To |
|
|
Notes |
2003-04-11 00:00:00 | 1) WHAT IS THE REAR ROOM TO BE USED FOR. | | | | 2) PLEASE LABEL VARIOUS AREAS. | | | | 3) WHAT IS THE SPACE USED FOR PRESENTLY. | | | | 4) PLEASE INDICATE AN OCCUPANT LOAD. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-05-14 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-14 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-14 |
Time |
09:24 |
Sent To |
|
|
Notes |
2003-05-14 00:00:00 | COMM BOARD #7 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-03 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-03 |
Time |
11:34 |
Sent To |
|
|
Notes |
2003-04-03 00:00:00 | COMM BOARD #9 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2003-05-19 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-05-19 |
Time |
16:21 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2003-05-19 |
Time |
16:21 |
Sent To |
|
|
Notes |
2003-05-19 00:00:00 | NO MECHANICAL TO BE DONE UNDER THIS | | PERMIT.HVAC IS EXISTING.PLEASE NOTE | | OUTSIDE AIR CALCS REQUIRED FOR CHANGE | | OF OCCUPANCY. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-04-12 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2003-04-12 |
Time |
10:39 |
Rev Time |
1.00 |
Received By |
hmoser |
Date |
2003-04-12 |
Time |
10:38 |
Sent To |
|
|
Notes |
2003-04-12 00:00:00 | PLAN DENIED | | 1) NO EQUIPMENT SECHEDULE | | 2) NO DUCTSIZE,GRILL SIZE,OR CFM.ON | | PLANS | | 3) NEED FRESH AIR CALCULATIONS | | PLAN REVIEW BY HAROLD MOSER | | (561)805-6732 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2003-04-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-04-12 |
Time |
13:49 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2003-04-12 |
Time |
13:49 |
Sent To |
|
|
Notes |
2003-04-12 00:00:00 | NO PLUMBING PLANS SUBMITTED - FIXTURE | | SET ONLY |
|
|