Plan Review Stops For Permit 03032368 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2004-03-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-03-05 |
Time |
15:51 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2004-03-05 |
Time |
15:51 |
Sent To |
|
|
Notes |
2004-03-05 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 | | | | 1.)SEPARATE PERMIT REQUIRED FOR THE | | IMPACT GLASS, SEE ATTACHED PERMIT | | APPLICATION.PRODUCT INFORMATION | | NOT SUBMITTED PRIOR TO PERMIT ISSUANCE | | REQUIRES SEPARATE PERMITS AND REVIEW. | | | | 2.)THE SITE SPECIFIC PRODUCT | | APPROVAL FORM IS INCOMPLETE.HOWEVER, | | THE MANUFACTURER HAS APPLIED FOR SITE | | SPECIFIC/LOCAL PRODUCT APPROVAL. PLEASE | | CALL PRIOR TO RESUBMITTAL TO DETERMINE | | STATUS OF THE LOCAL PRODUCT APPROVAL | | APPLICATION. | | | | 3.)THE LICENSE NUMBER OF THE ENGINEER | | IS REQUIRED TO BE ON EACH SHEET, | | FAC61G15-23.002. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2003-12-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-27 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-12-03 00:00:00 | REVISIONS DATED 11/20/03 WITH HAND | | CORRECTIONS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2003-11-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-01 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-11-24 |
Time |
10:37 |
Sent To |
|
|
Notes |
2003-11-24 00:00:00 | REVISIONS DATED 11/20/03, SHEETS 2,3 | | AND 4, RODNEY N. GREEN, ARCHITECTS. | | | | FBC TABLE 600 EXPRESSLY PROHIBITS | | EXTERIOR WALL OPENINGS WHEN A WALL IS | | LOCATED 0' TO 3' FROM A PROPERTY LINE. | | SHEETS | | 2 AND 3 PROPOSE GLASS BLOCK ON THE WEST | | SIDE WHICH ISNOT A LISTED FIRE RATED | | WALL ASSEMBLY.THIS ISSUE WAS COVERED | | PREVIOULY IN MEETINGS WITH THE | | ARCHITECT AND THE OWNER. | | | | REVISIONS TO SHEET 4 ARE NOT READILY | | DISCERNIBLE, PLEASE NOTE THE CHANGE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-08-29 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-08-29 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-08-29 |
Time |
08:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-08-11 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-08-11 |
Time |
07:28 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-08-11 |
Time |
07:28 |
Sent To |
FIRE |
|
Notes |
2003-08-11 00:00:00 | 2ND REVIEW | | 1)AS NOTED ON THE FIRST CHECKLIST THE | | OPENINGS IN THE EXTERIOR WALL ON THE | | SOUTH PROPERTY LINE ARE | | REQUIRED TO BE FIRE RATED, AND THE WEST | | WALL ARE PROHIBITTED BY FBC TABLE 600. | | THE ARCHITECT'S QUOTING OF FBC | | 3401.7.2.4 IS WITHOUT STANDING FOR THIS | | PROJECT.SEE FBC 3401.7.2.6 AND REVISE | | AS NECESSARY.ALSO, SEE FBC 104.2.1 | | WITH REGARDS TO QUOTING CODE SECTIONS | | NOT BEING AN ACCEPTABLE ALTERNATIVE TO | | SPECIFIC DESIGN INFORMATION. | | | | 2) VERTICAL ACCESIBILITY IS REQUIRED | | FOR OFFICES SHOWN AS #4 AND #5 AS | | PREVIOUSLY NOTED.SEE FBC 11-4.1.5.6 | | (1) (K) (III). | | | | 3) THE STRUCTURAL CALCULATIONS | | PREVIOUSLY REQUESTED FOR THE SECOND | | FLOOR CONSTRUCTION HAVE NOT BEEN | | PROVIDED. | | THE DECLARED 1/2" X 5" BOLTS @ 4' ON | | CENTER SHOWN IN SECTION 2/A ON SHEET 3 | | APPEARS TO BE VERY INADEQUATE FOR THE | | LOADS TO BE IMPOSED ON THE WOOD | | PERPENDICULAR TO THE GRAIN. HOW WAS THE | | MINIMAL 75# LIVE LOAD DETERMINED? | | PLEASE PROVIDE COMPLETE STRUCTURAL | | CALCULATIONS. | | | | 4) THE STAIRS TO OFFICES 4 AND 5 | | REQUIRE HANDRAILS ON EACH SIDE AN WITHIN | | 30" OF THE WIDTH REQUIRED FOR EGRESS. | | SEE FBC 1007.5.2, FBC 1007.5.5 AND FBC | | 1007.5.7.DO NOT QUOTE THOSE CODE | | SECTIONS BUT | | SHOW A GRAPHIC DEPICTION AND/OR NOTES | | TO CLEARLY SHOW THE DESIGN INTENT. | | INCLUDE FASTENING AND CONNECTION | | DETAILS. | | | | 5) PLEASE PROVIDE THE FIRE DESIGN | | NUMBER FOR THE SEVERAL PLACES CALLING | | OUT "1 FIRE RATED" SEE FBC 701.5. | | | | | | 6) SECTION 1/A, SHEET 3. THE STEEL | | COLUMN IS 3"X3"X WHAT? | | | | 7) SECTION 3/A, WHAT ARE THE | | DIMENSIONS,MATERIAL AND CONNECTION | | METHODS? | | | | 8) THE SIX INCH SPACE AT THE TOE RAIL | | OF THE GUARD RAIL SHOWN IN SECTION 3/A | | DOES NOT COMPLY WITH FBC 1015.3.IF THE | | GUARD RAIL IS A DELEGATED DESIGN SHOW | | MINIMUM REQUIRED LOADS AS PROVIDED FOR | | IN FBC 1608.2.2. | | | | 9) THE SECOND FLOOR STAIRS ARE REQUIRED | | TO BE ENCLOSED WITH FIRE RATED | | CONSTRUCTION AND TO PROVIDE A PROTECTED | | PATH TO THE OUTSIDE. | | SEE FBC 1006.1.1 AND FBC 1010.1. | | | | 10) TWO INDEPENDENT EXITS ARE REQUIRED | | FROM THE SECOND FLOOR.SEE FBC | | 1004.2.1 AND 1027.1.FURTHER, THE | | TRAVEL DISTANCE IS >75' SO A SINGLE EXIT | | IS NOT ALLOWED FOR GROUP B OCCUPANCY IN | | THIS CASE.SEE ALSO FBC 303.1 #4 WITH R | | ESPECT TO MIXED OCCUPANCIES. | | | | 11) SHOW OR NOTE SPECIFICALLY THE | | EXTERIOR TRIMS TO BE USED AS TO MATERIAL | | AND METHODS SEE FBC 104.2. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-04-11 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-04-11 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-04-11 |
Time |
10:56 |
Sent To |
|
|
Notes |
2003-04-11 00:00:00 | THE GENERAL NOTES ON SHEET 1 DECLARES | | THE 1997 STANDARD BUILDING CODE.THE | | CITYOF WEST PALM BEACH AND THE STATE OF | | FLORIDA ARE CURRENTLY USING THE 2001 | | FLORIDA BUILDING CODE. | | | | SEE FBC 104.3.1.1 FOR THE MINIMUM | | CRITERIA REQUIRED FOR PLAN REVIEW. | | | | THE ADDITION OF THE SECOND FLOOR AS | | WELLAS THE CHANGE OF USE FROM | | WAREHOUSE/STORAGE TO OFFICE IS SUBJECT | | TO IMPACT FEES COLLECTED BY THE COUNTY. | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | ISSUED THE FEES MUST BE PAID TO THE | | COUNTY, THE PERMIT PLANS STAMPED BY | | THAT OFFICE AND A COPY OF THE PAID | | RECEIPT ATTACHED TO THE PERMIT | | APPLICATION.CALL (561) 233-5025 FOR | | MORE INFORMATION. | | | | THE OPENINGS ON THE SOUTH AND EAST | | EXTERIOR WALLS ARE REQUIRED TO BE FIRE | | PROTECTED AS PROVIDED FOR IN FBC TABLE | | 600. | | | | OPENINGS IN THE WEST WALL ARE | | PROHIBITTED BY FBC TABLE 600. | | | | THE DESIGNATED FIVE FEET WIDE AISLE FOR | | THE HC PARKING SPACE IS NOT SHOWN ON THE | | SITE PLAN. SEE FBC 11- 4.6.3. | | | | VERTICAL ACCESSIBILITY IS REQUIRED FOR | | THE OFFICES SHOWN AS #4 & #5 AND THE | | SECOND FLOOR.SEE FBC 11- 4.1.6. | | | | PLEASE PROVIDE A BETTER STRUCTURAL | | FRAMING PLAN INCLUDING ALL OF THE | | DESIGN LOADS AND STANDARDS USED.SHOW | | THE MODIFICATIONS TO THE EXISTING WALLS | | IF ANY.THE PLACEMENT OF THE COLUMN AND | | FOOTING THAT ARE SHOWN IN SECTION ONLY. | | | | PROVIDE COMPLETE STRUCTURAL | | CALCULATIONSFOR THE SECOND FLOOR DESIGN. | | | | THE STAIRS MUST HAVE | | HANDRAILS COMPLYING WITH FBC 1007.5. | | | | THE SECOND FLOOR STAIRS ARE REQUIRED TO | | BE ENCLOSED IN FIRE RATED CONSTRUCTION. | | SEE FBC 1006.1.1. | | | | TWO MEANS OF EGRESS ARE REQUIRED FROM | | THE SECOND FLOOR.SEE FBC 1004.2.1 AND | | FBC 1027.1.1. | | | | THE 8" STAIR RISER SHOWN DOES NOT COMPLY | | WITH FBC 1007.3. | | | | THIS BUILDING IS LOCATED IN THE | | DESIGNATED FIRE DISTRICT AND EXTERIOR | | ARCHITECTURAL TRIM IS REQUIRED TO BE | | FIRE RETARDANT TREATED LUMBER OF | | NON-COMBUSTIBLE MATERIAL.SEE FBC | | F102.2.7 AS AMENDED BY THE CITY OF WEST | | PALM BEACH. | | | | PLEASE PROVIDE THREE COPIES OF SIGNED | | AND SEALED ENERGY CODE CALCLULATIONS. | | SEE FBC 13- 101.3. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2004-05-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-05-04 |
Time |
17:09 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-05-04 |
Time |
17:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2004-01-21 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-28 |
Time |
16:00 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-01-21 |
Time |
07:46 |
Sent To |
|
|
Notes |
2004-01-21 00:00:00 | **************** UNSAT *************** | | | | 1)NOTE: PLEASE HAVE PLANS SIGNED WITH | | ORIGINAL SIGNATURE. PLANS ARE SEEALED | | COPIES. | | PLEASE SEE FS 481.221. REQ'S PLANS TO BE | | ORIGINAL SIGNED, DATED AND SEALED. | | THE DATE ON THE SIGNATURE IS FROM | | 2/10/03 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-08-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-16 |
Time |
13:31 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-08-27 |
Time |
20:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-08-04 |
|
|
Cont ID |
|
Sent By |
dbaxter |
Date |
2003-08-27 |
Time |
13:37 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2003-08-04 |
Time |
16:45 |
Sent To |
|
|
Notes |
2003-08-04 00:00:00 | **************** UNSAT ************ | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAM, | | PANEL ETC. PANEL SHOWN AS 225A,ON RISER, | | 400A ON SCHEDULE AND400A OCP FEEDING | | A 225A PANEL. LOAD SHOWN AT 257A'S ON | | A 225A PANEL? | | | | 215/310-16/240/230/ ETC | | | | 2)NOTE: PLEASE SHOW LOAD CALCULATIONS | | AS REQUESTED ON FIRST REVIEW. 220 | | SEE ALL ART'S REFERENCED ON FIRST REVIEW | | | | 3)NOTE: PLEASE CLARIFY SOME CIRCUITING | | SHOWN FOR EM/EXT LTS MISSING. PLEASE SEE | | 700-12E FOR CIRCUITING. | | | | 4)NOTE: PLEASE CLARFIY LIGHTING SHOWN | | AS REQ'D SIGN CIRCUIT? SHOWN AS WHAT | | APPEARS TO BE FLOOD LTS? SYMBOL NOT | | SHOWN ON ELECTRICAL LEGEND? | | PLEASE SHOW REQ'D SIGN CIRCUIT AT | | ENTRANCE PER 600-5 | | | | 5)NOTE: PLEASE CLARIFY TWO A/C SYSTEMS | | NOW SHOWN ON PLANS AND ONLY ONE ON PANEL | | SCHEDULE? PLEASE ALSO INCLUDE ON LOAD | | CALCUALTIONS PER 220/215-5 | | CIRCUIT #'S SHOWN ON PLANS BUT DO NOT | | CORRELATE W/ PANEL SCHEDULE? | | | | 6)NOTE: PLEASE CLARIFY SEC`S, NOT SHOW- | | -ING ANY CONDUCTOR SIZE FROM METER TO | | MAIN? PLEASE ALSO SEE SIZE SHOWN FROM | | MAIN TO PANEL AS 3-# 4/0 MCM,,,? | | PLEASE SEE 310-16 FOR SIZING | | | | 7)NOTE: PLEASE SHOW GROUNDING ELECTRODE | | SYSTEM, PER 250-50 GRND RD, COLD WATER | | ETC, IF AVAILABLE. | | | | 8)NOTE: PLEASE SEE COPY OF FS 553.80(2)- | | (B) W/ RESPECT TO DESIGN PROFESSIONAL. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-04-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-04-07 |
Time |
13:09 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2003-04-07 |
Time |
13:09 |
Sent To |
|
|
Notes |
2003-04-07 00:00:00 | *********** UNSAT ***************** | | | | 1)NOTE; PLEASE SEE FIRE REVIEW COMMENTS | | THAT WILL HAVE AN AFFECT ON E-SHEETS. | | | | 2)NOTE: PLEASE CALRFIY IF THIS IS A NEW | | OR EXISTING SERVICE? SHOWN AS NEW, IS | | THIS REPLACING EXIST? | | | | 3)NOTE; PLEASE SEE FEEDER/SEC`S FOR | | NEW 400A SERVICE. PLEASE SIZE PER 310-16 | | SHOWN AS 3/0` WHICH ARE ONLY RATED FOR | | 200A`S. | | | | 4)NOTE ; PLEASE SHOW ALL CIRCUITING ON | | PLANS AND CORRELATE W/ SUBMITTED PANEL | | SCHEDULE. | | | | 5)NOTE: PLEASE SHOW LOAD CALCULATIONS, | | PER 220-3,220-10,220-11,220-13 ETC AND | | ALL CONTINUOUS LOADS PER 215-3/230-42 | | | | 6)NOTE: PLEASE SIZE OCP FOR AHU HEAT | | PER 424-3B MIN @125%. | | | | 7)NOTE:PLEASE CALRIFY CIRCUITING FOR | | EM/EXXT LTS PER700-12E | | | | PLEASE SUBMIT THE ABVOVE INFORMATION | | FOR REVIEW/. | | 561-659-8096 EXT 8372 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2003-09-05 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2003-09-05 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-09-05 |
Time |
09:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2003-08-13 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2003-08-13 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-08-13 |
Time |
13:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2003-04-04 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-08-11 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-04-04 |
Time |
16:11 |
Sent To |
|
|
Notes |
2003-04-04 00:00:00 | 1) BUILDING ADDRESS NOT SHOWN ON | | ELEVATION DRAWINGS. | | | | 2) NO INTERIOR FINISH CLASSIFICATION | | FOR THE WALLS AND CEILINGS. | | | | 3) RISERS FOR STAIRS NEAR SECRETARY | | POOL AREA DOES NOT MEET CODE. | | | | 4) STAIRS NEAR KITCHEN DOES NOT MEET | | CODE. | | | | 5) ILLUMINATED EXIT SIGNS AND EMERGENCY | | LIGHTS SHALL BE PLACED ON THE SAME | | DRAWING. | | | | 6) NO FIRE EXTINGUISHERS SHOWN ON THE | | PLANS. | | | | 7) IF NO FIRE SPRINKLERS ARE PLANNED, | | THEN STORAGE ROOMS SHALL BE FIRE | | RATED AT LEAST ONE HOUR WITH PROPER | | OPENING PROTECTIVES. | | | | 8) WRONG BUILDING CODE REFERENCED ON | | THE PLANS. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2004-04-28 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-28 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-28 |
Time |
16:00 |
Sent To |
E |
|
Notes |
2004-04-28 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2004-02-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-27 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-27 |
Time |
14:14 |
Sent To |
B |
|
Notes |
2004-02-27 00:00:00 | TO SH DESK/SUBMITTALS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2004-01-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-16 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-16 |
Time |
13:31 |
Sent To |
E |
|
Notes |
2004-01-16 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-12-01 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-01 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-01 |
Time |
13:31 |
Sent To |
B |
|
Notes |
2003-12-01 00:00:00 | TO HP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-08-27 |
|
|
Cont ID |
|
Sent By |
dbaxter |
Date |
2003-08-27 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
dbaxter |
Date |
2003-08-27 |
Time |
13:31 |
Sent To |
E |
|
Notes |
2003-08-27 00:00:00 | TO DPALMER DESK. | | TO COMM BD. #48 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-07-24 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-24 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-24 |
Time |
14:17 |
Sent To |
|
|
Notes |
2003-07-24 00:00:00 | TO COMM BD. #52 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-04-01 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-01 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-01 |
Time |
13:30 |
Sent To |
|
|
Notes |
2003-04-01 00:00:00 | COMM BOARD #29 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2003-11-19 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-11-19 |
Time |
15:25 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2003-11-19 |
Time |
15:25 |
Sent To |
|
|
Notes |
2003-11-19 00:00:00 | AS BUILT DWGS |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-08-04 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-08-04 |
Time |
11:09 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2003-08-04 |
Time |
11:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-04-15 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-04-15 |
Time |
08:55 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2003-04-15 |
Time |
09:20 |
Sent To |
|
|
Notes |
2003-04-15 00:00:00 | DENIED:2001 FLORIDA BUILDING CODE, | | (MECHANICAL) | | 1.AS PER 2001 FBC(M) 501.3, EXHAUST | | SYSTEM SHALL BE DISCHARGED OUTDOORS AT | | A POINT FROM WHICH IT CANNOT AGAIN BE | | DRAWN IN BY THE VENTILATION SYSTEM. | | (EXHAUST OUTLET IN RELATION TO OUTSIDE | | AIR INTAKE). | | | | 2.CLARIFY THE 6" OUTSIDE AIR DUCT | | TERMINATING IN THE AHU CLOSET.THE | | RETURN AIR APPEARS TO BE DUCTED INTO | | THE AHU.IS THE O.A. TIED INTO THE | | RETURN OR OPEN TO THE AHU CLOSET? | | | | 3.TOILET ROOM BETWEEN OFFICE #4 & 5 | | DOES NOT INDICATE AN EXHAUST FAN.AS | | PER 2001 FBC(M) 501.2 SINGLE OR COMBINED | | MECHANICAL EXHAUST SYSTEMS FROM TOILET, | | URINAL & SIMILAR ROOMS SHALL BE | | INDEPENDENT IF OTHER EXHAUST SYSTEMS. | | ALSO 403.2.1, ROOMS CONTAINING SHOWERS, | | BATHTUBS OR SIMILAR BATHING FIXTURES | | SHALL BE MECHANICALLY EXHAUSTED. | | | | 4.FRESH AIR CALCS ARE INCOMPLETE, THE | | DO NOT INDICATE SQ FOOTAGE OR NUMBER | | OF PEOPLE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2003-09-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-09-04 |
Time |
16:52 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-09-04 |
Time |
16:52 |
Sent To |
|
|
Notes |
2003-09-04 00:00:00 | PASSED/PROVISO | | | | BATHROOM BETWEEN OFFICES SHALL COMPLY | | WITH 11-4.23 - SHOWER SHALL COMPLY WITH | | 11-4.21 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-09-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-07-24 |
Time |
13:03 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2003-07-24 |
Time |
16:02 |
Sent To |
|
|
Notes |
2003-07-24 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | FBC-2001 AMENDMENTS, CHAPTER | | ONE, ADMIN. CODE | | | | 1) FROM PREVIOUS REVIEW: SHOW DETAIL FOR | | TOILET ROOMS. FOR WATER CLOSETS SHOW | | CLEAR FLOOR SPACE 11-4.16.2, HEIGHT | | 11-4.16.3, GRAB BARS 11-4.16.4, AND | | FLUSH CONTROLS 11-4.16.5. FOR LAVS SHOW | | HEIGHT & CLEARANCES 11-4.19.2, CLEAR | | FLOOR SPACE 11-4.19.3, EXPOSED PIPES | | 11-4.19.4, AND FAUCETS 11-4.19.5. FOR | | BREAK ROOM SINK SHOW HEIGHT 11-4.24.2, | | KNEE CLEARANCES 11-4.24.3, DEPTH 11-4. | | 24.4, CLEAR FLOOR SPACE 11-4.24.5, EX- | | POSED PIPES & SURFACES 11-4.24.6, AND | | FAUCETS 11-4.24.7. SECTION 104.2.1 - | | INFORMATION SHALL BE SPECIFIC, AND THE | | TECHNICAL CODES SHALL NOT BE CITED AS A | | WHOLE OR IN PART, NOR SHALL THE TERM | | "LEGAL" OR ITS EQUIVALENT BE USED AS A | | SUBSTITUTE FOR SPECIFIC INFORMATION. | | 2) TOILET ROOM FOR OFFICES #'S 4 & 5 IS | | NOT A PRIVATE TOILET ROOM BUT A COMMON | | USE TOILET ROOM AND SHALL BE ACCESSIBLE. | | SEE COMMENT #1 FOR DETAILS REQUIRED FOR | | TYPICAL ACCESSIBLE TOILET ROOM. ALSO | | SHOW COMPLIANCE WITH 11-4.21 AND ALL | | SUBSECTIONS. SIZE & CLEARANCE 11-4.21.2, | | SEAT 11-4.21.3, GRAB BARS 11-4.21.4, | | CONTROLS 11-4.21.5, & CURBS 11-4.21.7 | | 3) NEW COMMENT, PER TABLE 403.1 A DRINK- | | ING FOUNTAIN IS REQUIRED. ALSO SEE SECT- | | ION 410.1 | | 4) NEW COMMENT SUBMIT A WATER RISER DIA- | | GRAM. WATER HAMMER ARRESTORS REQUIRED BY | | SECTION 604.9 (AT DISHWASHER & ICE MAKER | | IN REFRIG. IF INSTALLED), SHALL BE LOCA- | | TED NEAR THE FIXTURE IN AN "EFFECTIVE | | RANGE" AND NOT IN THE CEILING AT THE TOP | | OF THE DROPS. | | 5) PLEASE SEE ATTACHED SHEET CONCERNING | | ARCHITECTS SEAL AND TITLE BLOCK REQUIRED | | FOR EACH SHEET. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-04-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-04-12 |
Time |
11:54 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-04-12 |
Time |
11:44 |
Sent To |
|
|
Notes |
2003-04-12 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) SHT 2 SECTION 11-4.1.6, IF EXISTING | | ELEMENTS, SPACES, OR COMMON AREAS ARE | | ALTERED, THEN EACH SUCH ALTERED ELEMENT, | | SPACE, FEATURE, OR AREA SHALL COMPLY | | WITH THE APPLICABLE PROVISIONS OF | | 11-4.1.1 TO 11-4.1.3 - IF TOILET ROOMS | | ARE PROVIDED THEN EACH PUBLIC AND COMMON | | USE TOILET SHALL COMPLU WITH 11-4.22 | | IF BATHING ROOMS ARE PROVIDED, THEN EACH | | PUBLIC AND COMMON USE BATHROOM SHALL | | COMPLY WITH 11-4.23. - PLEASE SHOW CLEAR | | FLOOR SPACE, TURNING CIRCLE ECT. TO | | COMPLY WITH 11-4.16 AND ALL SUB SECTIONS | | ALSO SHOW DETAIL FOR SHOWER SHOWING | | COMPLIANCE WITH 11-4.21 AND ALL SUBSEC- | | TIONS. | | 2) SHT 2 NEW BREAK SINK, SUBMIT DETAIL | | SHOWING COMPLIANCE WITH 11-4.24 AND ALL | | SUBSECTIONS. | | 3) SEPARATE PERMIT REQUIRED FOR IRRIGAT- | | ION. SUBMIT PLANS AT TIME OF APPLICATION | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2003-09-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-09-05 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|