Plan Review Details - Permit 03032205
Plan Review Stops For Permit 03032205
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-04-14 Cont ID  
Sent By jwitmer Date 2003-04-14 Time 12:58 Rev Time 0.77
Received By jwitmer Date 2003-04-14 Time 12:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-06-24 Cont ID  
Sent By dpalmer Date 2003-06-24 Time 16:24 Rev Time 0.50
Received By dpalmer Date 2003-06-24 Time 16:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-07 Cont ID  
Sent By shernand Date 2003-06-18 Time 15:57 Rev Time 0.33
Received By dpalmer Date 2003-04-07 Time 06:31 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2003-04-11 Cont ID  
Sent By mcarsill Date 2003-04-11 Time 14:31 Rev Time 0.00
Received By mcarsill Date 2003-04-11 Time 14:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-06-18 Cont ID  
Sent By shernand Date 2003-06-18 Time 15:57 Rev Time 0.00
Received By shernand Date 2003-06-18 Time 15:57 Sent To E
Notes
2003-06-18 00:00:00DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-05-30 Cont ID  
Sent By shernand Date 2003-05-30 Time 14:42 Rev Time 0.00
Received By shernand Date 2003-05-30 Time 14:42 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-05-16 Cont ID  
Sent By shernand Date 2003-05-16 Time 16:12 Rev Time 0.00
Received By shernand Date 2003-05-16 Time 16:12 Sent To P
Notes
2003-05-16 00:00:00KSTEVENS DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-28 Cont ID  
Sent By shernand Date 2003-04-28 Time 14:29 Rev Time 0.00
Received By shernand Date 2003-04-28 Time 14:29 Sent To  
Notes
2003-04-28 00:00:00COMM BOARD #24RESUB M & P.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-04 Cont ID  
Sent By shernand Date 2003-04-04 Time 14:45 Rev Time 0.00
Received By shernand Date 2003-04-04 Time 14:45 Sent To  
Notes
2003-04-04 00:00:00HEALTH DEPT APPROV. SUBMITTAL IN BOX #11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-01 Cont ID  
Sent By sthyng Date 2003-04-01 Time 09:35 Rev Time 0.00
Received By sthyng Date 2003-03-27 Time 09:35 Sent To  
Notes
2003-04-01 00:00:00COMM BOARD #11

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-06-03 Cont ID  
Sent By pkrauss Date 2003-06-03 Time 08:33 Rev Time 0.35
Received By pkrauss Date 2003-06-03 Time 08:33 Sent To  
Notes
2003-06-03 00:00:00MECHANICAL REVISION PERMIT 03032214

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-05-08 Cont ID  
Sent By shernand Date 2003-05-30 Time 14:42 Rev Time 0.45
Received By pkrauss Date 2003-05-08 Time 09:36 Sent To  
Notes
2003-05-08 00:00:00PLANS APPROVED/STAMPED 5-6-03, DID NOT
 ENTER IN THE COMPUTER.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-04-16 Cont ID  
Sent By pkrauss Date 2003-04-16 Time 16:25 Rev Time 0.35
Received By pkrauss Date 2003-04-16 Time 16:22 Sent To  
Notes
2003-04-16 00:00:00PLEASE PROVIDE INFORMATION ON MAKE-UP
 AIR.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 4 Status P Date 2003-05-27 Cont ID  
Sent By kstevens Date 2003-05-27 Time 11:17 Rev Time 0.33
Received By kstevens Date 2003-05-27 Time 11:17 Sent To  
Notes
2003-05-27 00:00:00PASSED/PROVISO
  
 FLOOR SINK REQUIRED FOR DISHWASHER.
 REVISION REQUIRED.

Review Stop P PLUMBING
Rev No 3 Status F Date 2003-05-12 Cont ID  
Sent By shernand Date 2003-05-16 Time 16:12 Rev Time 0.33
Received By kstevens Date 2003-05-12 Time 09:31 Sent To  
Notes
2003-05-12 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) PLEASE SUBMIT 2 COMPLETE SETS OF
 PLANS. REMOVE OLD SHEET AND INSERT NEW
 SHEETS.
 2) FLOOR SINKS REQUIRED FOR INDIRECT
 WASTE PER SECTION 802.3
 3) FIXTURE LOCATED NEAR THE DISHWASHER
 SHALL TIE INTO THE GREASE WASTE. D/W
 ONLY TO SANT.
  
  
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-05-10 Cont ID  
Sent By kstevens Date 2003-05-10 Time 05:26 Rev Time 0.50
Received By kstevens Date 2003-05-10 Time 05:26 Sent To  
Notes
2003-05-10 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 COMMENTS FROM PREVIOUS REVIEW NOT ADD-
 RESSED. SEE NEW SHT P-1.1
 1) SHT P-1.1 DISHWASHER SHALL DRAIN INTO
 SANITARY NOT GREASE WASTE. UTILITY ORD.
 2) ALL ABANDONED/CAPPED PIPES SHALL BE
 INSPECTED PRIOR TO COVERING.
 3) SHT P-1.1, 3 COMPARTMENT SINK SHALL
 DRAIN TO GREASE WASTE.
 4) SHT P-1.1 ALL INDIRECT WASTE SHALL
 DRAIN TO FLOOR SINKS. SEC 802.3 - FLOOR
 DRAINS ARE NOT AN APPROVED INDIRECT
 WASTE RECEPTOR.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-04-12 Cont ID  
Sent By kstevens Date 2003-04-12 Time 10:42 Rev Time 0.75
Received By kstevens Date 2003-04-12 Time 10:42 Sent To  
Notes
2003-04-12 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT P-1.1 DISHWASHER SHALL DRAIN INTO
 SANITARY NOT GREASE DRAIN. UTILITY ORD.
 2) ALL ABANDONED/CAPPED PIPES SHALL BE
 INSPECTED PRIOR TO COVERING
 3) SHT P-1.1 3 COMPARTMENT SINK SHALL
 DRAIN TO GREASE WASTE.
 SHT P-1.1 ALL INDIRECT WASTE SHALL DRAIN
 TO FLOOR SINKS. SECTION 802.3 - FLOOR
 DRAINS ARE NOT AN APPROVED INDIRECT
 WASTE RECEPTOR.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692