Plan Review Details - Permit 03032151
Plan Review Stops For Permit 03032151
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-04-03 Cont ID  
Sent By dpalmer Date 2003-04-02 Time 15:01 Rev Time 0.50
Received By lsmith Date 2003-04-03 Time 14:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-02 Cont ID  
Sent By kstevens Date 2003-04-02 Time 04:19 Rev Time 0.25
Received By dpalmer Date 2003-04-02 Time 15:01 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-25 Cont ID  
Sent By shernand Date 2003-04-25 Time 09:12 Rev Time 0.00
Received By shernand Date 2003-04-25 Time 09:12 Sent To P
Notes
2003-04-25 00:00:00KSTEVENS DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-27 Cont ID  
Sent By sthyng Date 2003-03-27 Time 08:16 Rev Time 0.00
Received By sthyng Date 2003-03-27 Time 08:16 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-04-29 Cont ID  
Sent By kstevens Date 2003-04-29 Time 08:09 Rev Time 0.33
Received By kstevens Date 2003-04-29 Time 08:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-04-26 Cont ID  
Sent By kstevens Date 2003-04-26 Time 08:53 Rev Time 0.25
Received By kstevens Date 2003-04-26 Time 08:49 Sent To  
Notes
2003-04-26 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 1) FROM PREVIOUS REVIEW:
 SPA DRAINS NOT SHOWN ON POOL LAYOUT,
 BUT SHOWN ON PIPING SCHEMATIC. PLEASE
 CLAIRFY.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-04-02 Cont ID  
Sent By shernand Date 2003-04-25 Time 09:12 Rev Time 0.33
Received By kstevens Date 2003-04-02 Time 04:07 Sent To E
Notes
2003-04-02 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-4 92, AND NSPI-5. (ADD TO
 NOTES)
 2) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 3) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 4) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 5) SPA DRAINS NOT SHOWN ON POOL LAYOUT
 BUT SHOWN ON PIPING SCHEMATIC. PLEASE
 CLAIRFY.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2003-03-31 Cont ID  
Sent By sthyng Date 2003-03-27 Time 08:16 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***