Plan Review Details - Permit 03032151
Plan Review Stops For Permit 03032151 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-04-02 |
Time |
15:01 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2003-04-03 |
Time |
14:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-04-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-04-02 |
Time |
04:19 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-04-02 |
Time |
15:01 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-04-25 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-25 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-25 |
Time |
09:12 |
Sent To |
P |
|
Notes |
2003-04-25 00:00:00 | KSTEVENS DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-03-27 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-27 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-03-27 |
Time |
08:16 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2003-04-29 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-04-29 |
Time |
08:09 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-04-29 |
Time |
08:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-04-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-04-26 |
Time |
08:53 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2003-04-26 |
Time |
08:49 |
Sent To |
|
|
Notes |
2003-04-26 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | 1) FROM PREVIOUS REVIEW: | | SPA DRAINS NOT SHOWN ON POOL LAYOUT, | | BUT SHOWN ON PIPING SCHEMATIC. PLEASE | | CLAIRFY. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-04-02 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-25 |
Time |
09:12 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-04-02 |
Time |
04:07 |
Sent To |
E |
|
Notes |
2003-04-02 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | FORMATION REQUIRED FOR PLAN REVIEW | | 1) FBC-2001 SEC 424.2.6.1 ENGINEERING | | DESIGN, CONSTRUCTION AND WORKMANSHIP. | | ANSI/NSPI-4 92, AND NSPI-5. (ADD TO | | NOTES) | | 2) FBC-2001 424.2.9 WATER SUPPLY, LOCAL | | ORD. #2853-95, BACKFLOW REQUIRED ON | | WATER SERVICE. (ADD TO NOTES) | | 3) FBC-2001 424.2.12.1 PRESSURE TESTS. | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | FITTINGS. (ADD TO NOTES) | | 4) FBC-2001 424.2.13.2JOINTS AND CON- | | NECTIONS, FBC PLMG SEC 605.21, PURPLE | | PRIMER REQUIRED ON PVC PIPING. (ADD TO | | NOTES) | | 5) SPA DRAINS NOT SHOWN ON POOL LAYOUT | | BUT SHOWN ON PIPING SCHEMATIC. PLEASE | | CLAIRFY. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-03-31 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-27 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|
|