Plan Review Details - Permit 03031801
Plan Review Stops For Permit 03031801 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-04-02 |
Time |
17:54 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
2003-04-03 |
Time |
14:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-04-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-04-21 |
Time |
10:51 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-04-21 |
Time |
10:51 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-04-02 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-16 |
Time |
14:32 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-04-02 |
Time |
17:54 |
Sent To |
B |
|
Notes |
2003-04-02 00:00:00 | **************** UNSAT ************ | | | | 1)NOTE: PLEASE SEE LOAD CALCULATIONS, | | SHOWS 157A LOAD ON AN EXISTING 150A | | SERVICE? | | PLEASE SUBMIT PLANS AND PERMIT APPLICAT- | | ION FOR SERVICE CHANGE. | | | | IF THERE ARE ANY QUESTIONS,PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-04-16 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-16 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-16 |
Time |
14:32 |
Sent To |
E |
|
Notes |
2003-04-16 00:00:00 | DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-03-21 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-21 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-03-21 |
Time |
11:07 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-04-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-04-23 |
Time |
18:10 |
Rev Time |
1.25 |
Received By |
kstevens |
Date |
2003-04-23 |
Time |
18:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-04-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-04-21 |
Time |
10:51 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-04-01 |
Time |
16:26 |
Sent To |
E |
|
Notes |
2003-04-01 00:00:00 | DENIED | | REFERENCE: FBC 424.2 SWIMMING POOLS | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | FORMATION REQUIRED FOR PLAN REVIEW | | 1) FBC-2001 424.2.9 WATER SUPPLY, LOCAL | | ORD. #2853-95, BACKFLOW REQUIRED ON | | WATER SERVICE. (ADD TO NOTES) | | 2) FBC-2001 424.2.14.2 WATER RETENTION, | | PROVIDE A POSITIVE MEANS OF RETAINING | | WATER IN THE HEATER WHEN PUMP IS SHUT | | OFF. (MANUFACTURE CUT SHEETS SUBMITTAL) | | 3) FBC-2001 424.2.14.4 CONNECTIONS, ALL | | WATER HEATING EQUIPMENT SHALL BE INSTAL- | | LED WITH FLANGES OR UNION CONNECTIONS | | ADJACENT TO THE HEATER. (ADD TO NOTES) | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-03-27 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-21 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|
|