Plan Review Details - Permit 03031456
Plan Review Stops For Permit 03031456 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-04-08 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-16 |
Time |
16:29 |
Rev Time |
2.50 |
Received By |
lsmith |
Date |
2003-04-08 |
Time |
09:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-11-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-11-18 |
Time |
11:50 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-11-18 |
Time |
11:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-04-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-17 |
Time |
08:35 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-04-02 |
Time |
06:59 |
Sent To |
P |
|
Notes |
2003-04-02 00:00:00 | ************ NOTES/REDLINED*********** | | | | PLEASE SEE PLANS, THERE ARE MISSING ITEM | | -S REDLINED. | | | | 1)NOTE: PLEASE MOVE SD INSIDE MASTER | | BEDROOM.NFPA-72 8-1.4.2 | | | | 2)NOTE: PLEASE SEE 210-52C-1 FOR COUNTER | | TOP OUTLET SPACING IN KITCHEN. MISSING | | ONE. | | | | 3)NOTE: PLEASE SEE MISSING RECEPT PER | | 210-52 W/IN 6' OF DOORWAY IN BREAKFAST | | AREA. | | 4)NOTE: PLEASE SEE MISSING EQUIPMENT | | GROUNDING CONDUCTOR BETWEEN MAIN DISC | | AND PANEL. SIZE PER 250-122 | | | | PLEASE REVISE PLANS BEFORE ROUGH. | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | EELCTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-11-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-17 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-17 |
Time |
08:35 |
Sent To |
E |
|
Notes |
2003-11-17 00:00:00 | TO BT DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-04-16 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-16 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-16 |
Time |
16:28 |
Sent To |
B |
|
Notes |
2003-04-16 00:00:00 | LSMITH DESK TO CONFIRM PAYMENT OF | | IMPACT FEES. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-03-19 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-19 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-03-19 |
Time |
09:47 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-04-03 |
Time |
18:14 |
Rev Time |
0.33 |
Received By |
rregueir |
Date |
2003-04-03 |
Time |
20:13 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-04-02 |
Time |
06:59 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2003-04-03 |
Time |
18:14 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-03-24 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-19 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
E |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy