Plan Review Stops For Permit 03031449 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-04-28 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2003-04-28 |
Time |
08:43 |
Rev Time |
1.00 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-04-07 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-24 |
Time |
11:48 |
Rev Time |
3.00 |
Received By |
lsmith |
Date |
2003-04-07 |
Time |
14:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-08-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-08-26 |
Time |
13:09 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-08-26 |
Time |
13:08 |
Sent To |
|
|
Notes |
2003-08-26 00:00:00 | ********* NOTE ************** | | | | MAIN REDLINED NEXT TO METER ON RISER | | AS SHOWN ON PLAN. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-04-29 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-21 |
Time |
12:55 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-04-29 |
Time |
18:46 |
Sent To |
Z |
|
Notes |
2003-04-29 00:00:00 | PLANS INCREASED SQ FT , NEEDS ZONING. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-04-02 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2003-04-28 |
Time |
08:18 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-04-02 |
Time |
07:21 |
Sent To |
P |
|
Notes |
2003-04-02 00:00:00 | *************NOTES REDLINED ************ | | | | PLEASE NOTE, THE FOLLOWING ARE ITEMS | | MISSING ON PLANS. | | | | 1)NOTE: PLEASE MOVE SD INTO MASTER | | BEDROOM. NFPA-72 8-1.4.2 | | | | 2)NOTE: PLEASE SEE MISSING EQUIPMENT | | GROUNDING CONDUCTOR FROM MAIN DISCONNECT | | TO PANEL. PER 250-122 | | | | 3)NOTE: PLEASE SEE MISSING COUNTERSPACE | | RECEPT PER 210-52-C-1 | | | | 4)NOTE: PLEASE SEE MISSING RECEPT IN | | BREAKFAST AREA W/IN 6' OF DOOR. 210-52 | | | | PLEASE REVISE AND SUBMIT FOR REVIEW | | BEFORE ROUGH. IF THERE ARE ANY QUESTIONS | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-08-21 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-21 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-21 |
Time |
12:54 |
Sent To |
E |
|
Notes |
2003-08-21 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-04-24 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-04-30 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-24 |
Time |
11:41 |
Sent To |
B |
|
Notes |
2003-04-24 00:00:00 | LSMITH DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-03-19 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-19 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-03-19 |
Time |
09:46 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-04-03 |
Time |
18:16 |
Rev Time |
0.25 |
Received By |
hmoser |
Date |
2003-04-03 |
Time |
19:43 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-04-02 |
Time |
07:22 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-04-03 |
Time |
18:16 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2003-04-30 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-04-30 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-03-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-04-29 |
Time |
18:58 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
E |
|
Notes |
|
|