Plan Review Stops For Permit 03031046 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2003-07-07 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-07-07 |
Time |
16:54 |
Rev Time |
0.25 |
Received By |
sthyng |
Date |
2003-07-07 |
Time |
16:54 |
Sent To |
|
|
Notes |
2003-07-07 00:00:00 | REVISION FOR UPDATED TRUSS CONNECTORS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-06-26 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-07 |
Time |
09:24 |
Rev Time |
0.50 |
Received By |
sthyng |
Date |
2003-06-26 |
Time |
08:09 |
Sent To |
|
|
Notes |
2003-06-26 00:00:00 | *****PROVISO***** | | SUBMIT REVISION FOR TRUSS | | CONNECTORS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-06-23 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-06-23 |
Time |
12:24 |
Rev Time |
0.50 |
Received By |
sthyng |
Date |
2003-06-23 |
Time |
12:24 |
Sent To |
|
|
Notes |
2003-06-23 00:00:00 | ******CORRECTIONS******* | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)TRUSS CONNECTOR UPLIFT SPECIFIED | | ON THE PLAN EXCEED MAXIMUM VALUES | | ALLOWED IN THE CATALOG; REFER TO USP | | 2003 CATALOG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-04-21 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-20 |
Time |
10:53 |
Rev Time |
2.50 |
Received By |
lhatten |
Date |
2003-04-20 |
Time |
16:18 |
Sent To |
|
|
Notes |
2003-04-21 00:00:00 | REVIEW & STAMPED PLANS 04/20/2003 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-11-17 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-11-17 |
Time |
07:53 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-11-17 |
Time |
07:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-11-04 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-14 |
Time |
10:30 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-11-04 |
Time |
08:19 |
Sent To |
|
|
Notes |
2003-11-04 00:00:00 | *********** UNSAT ************* | | | | 1)NOTE: PLEASE INCLUDE ALL INFORMATION | | AS SET FORTH IN FAC 61G1-16.004 PER FS | | 481 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-03-28 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-29 |
Time |
16:16 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-03-28 |
Time |
06:35 |
Sent To |
P |
|
Notes |
2003-03-28 00:00:00 | ******** NOTES REDLINED *********** | | | | PLEASE SEE CIRCUITS SHOWN FOR GEN LT | | ON PANEL "B" SHOWN AS #6, 60A?? | | PLEASE ALSO SEE PANEL "A", SHOWS 10 CIR | | FOR 2POLE? |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-11-14 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-14 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-14 |
Time |
10:30 |
Sent To |
E |
|
Notes |
2003-11-14 00:00:00 | TO BT DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-10-29 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-29 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-29 |
Time |
16:16 |
Sent To |
E |
|
Notes |
2003-10-29 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-07-07 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-07 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-07 |
Time |
09:24 |
Sent To |
B |
|
Notes |
2003-07-07 00:00:00 | STHYNG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-06-20 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-20 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-20 |
Time |
10:53 |
Sent To |
B |
|
Notes |
2003-06-20 00:00:00 | STHYNG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-03-14 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-14 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-03-14 |
Time |
13:45 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-03-31 |
Time |
18:53 |
Rev Time |
0.33 |
Received By |
rregueir |
Date |
2003-04-03 |
Time |
19:15 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-03-31 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-03-28 |
Time |
06:35 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-03-31 |
Time |
18:53 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-03-17 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-14 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
E |
|
Notes |
|
|