Plan Review Stops For Permit 03030854 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2003-05-14 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-21 |
Time |
13:42 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2003-05-14 |
Time |
16:25 |
Sent To |
|
|
Notes |
2003-05-14 00:00:00 | CHECKLIST FOR ARCHITECT'S APPROVAL | | LETTER REGARDING WINDOWS: | | 1-WHAT IS A "34HS" WINDOW? IS THIS A | | HORIZONTAL SLIDER?. SEE PLANS THERE | | THERE ARE NOT HORIZONTAL SLIDERS | | SPECIFIED ON THE WINDOW SCHEDULE. | | 2-WHAT ARE THE "ALL FBC DESIGN REQUIRE- | | MENTS" BEEN REVIEWED FOR?. WIND LOAD?, | | EGRESS?. | | 3-MY ORIGINAL COMMENT WAS THAT WINDOW | | "F" 34SH DIDN'T MEET THE MINIMUM 24" | | CLEAR HEIGHT OPENING REQUIRED BY SEC. | | 1005.4 FBC 2001 FOR BEDROOMS. | | THE APPROVAL LETTER SUBMITTED BY THE | | ARCHITECT DOESN'T ADDRESS THIS ISSUE. | | THE WINDOW SCHEDULE IS THE ONE THAT | | NEEDS TO BE REVISED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-05-06 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-12 |
Time |
11:00 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2003-05-06 |
Time |
12:16 |
Sent To |
|
|
Notes |
2003-05-06 00:00:00 | ENERGY CALCULATIONS, STORM SHUTTERS AND | | REVISED SHEET S1. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-04-07 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-04-28 |
Time |
09:17 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2003-04-07 |
Time |
11:05 |
Sent To |
|
|
Notes |
2003-04-07 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-PROVIDE UPDATED SBCCI REPORT #2229A | | THAT MATCHES ENGINEERED DRAWINGS FOR | | STORM SHUTTERS. | | 2-DETAIL S21 FOR COLUMN BETWEEN GARAGE & | | STAIRWAY DOESN'T WORK. REVISE AS REQ'D | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | 3-ROOF FRAMING FRAMING PLAN. REVISE TC-1 | | CONNECTOR SPECIFIED @ FRONT ELEVATION. | | NEED WOOD TO WOOD CONNECTOR. SECTION | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | 4-WINDOW 34SH DOESN'T PROVIDE THE 24" | | CLEAR HEIGHT REQUIRED BY SEC. 1005.4 | | FBC 2001. REVISE/CLARIFY AS REQUIRED. | | ALSO, VERIFY THAT WINDOW 24+5SH WINDOW | | PROVIDES 24" CLEAR HEIGHT AND 5.7S.F. | | CLEAR OPENING. | | 5-RE-SUBMIT ENERGY CALCULATIONS WITH | | ENGINEER'S ORIGINAL SIGNATURE AND SEAL | | AS REQUIRED BY CHAPTER 471 FL. STATUTE | | AND SEC. 103.0 CHAPTER 13 FBC 2001. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-08-11 |
Time |
18:00 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-08-11 |
Time |
18:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-03-25 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-06 |
Time |
10:42 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-03-25 |
Time |
06:01 |
Sent To |
P |
|
Notes |
2003-03-25 00:00:00 | *** NOTES REDLINED FOR OCP/AWG OF SUB- | | -PANEL. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2003-08-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-20 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-08-20 |
Time |
09:52 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-08-06 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-06 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-06 |
Time |
10:42 |
Sent To |
E |
|
Notes |
2003-08-06 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-05-21 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-21 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-21 |
Time |
13:42 |
Sent To |
B |
|
Notes |
2003-05-21 00:00:00 | JGOMEZ DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-05-12 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-12 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-12 |
Time |
11:00 |
Sent To |
B |
|
Notes |
2003-05-12 00:00:00 | JGOMEZ DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-04-28 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-04-28 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-04-28 |
Time |
09:17 |
Sent To |
B |
|
Notes |
2003-04-28 00:00:00 | TO JG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-03-12 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-12 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-03-12 |
Time |
14:14 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-03-31 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-20 |
Time |
09:53 |
Rev Time |
0.25 |
Received By |
hmoser |
Date |
2003-03-31 |
Time |
18:35 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-03-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-03-25 |
Time |
06:06 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-03-27 |
Time |
17:27 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-03-17 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-12 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
E |
|
Notes |
|
|