Plan Review Details - Permit 03030708
Plan Review Stops For Permit 03030708
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-08-07 Cont ID  
Sent By hpiskura Date 2003-08-07 Time 10:45 Rev Time 0.00
Received By hpiskura Date 2003-08-06 Time 13:44 Sent To  
Notes
2003-08-07 00:00:00THE PROPOSED CHANGE TO THE ROOF FROM A
 FLAT ROOF TO A HIPPED ROOF IS SUBJECT
 TO APPROVAL BY THE HISTORIC
 PRESERVATION BOARD AND MAY NOT PERMITTED
 AT THIS TIME.CONTACT MS. SHERRY
 PILAND AT 659-8031 FOR MORE INFORMATION.
  
 A COMPLETE PLAN REVIEW FOR CODE
 COMPLIANCE CANNOT BE ACCOMPLISHED AT
 THIS TIME.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-05-30 Cont ID  
Sent By hpiskura Date 2003-05-16 Time 14:17 Rev Time 0.00
Received By sgraham Date 2003-05-16 Time 14:07 Sent To  
Notes
2003-05-16 00:00:00SAME AS 4/9/03 COMMENTS.A FLORIDA
 REGISTERED ENGINEER OR ARCHITECT IS
 REQUIRED TO PREPARE THE PLANS AND
 ADDRESS THE STRUCTURAL, FIRE AND LIFE
 SAFETY ISSUES OF THE 2001 FLORIDA
 BUILDING CODE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-09 Cont ID  
Sent By hpiskura Date 2003-04-09 Time 13:53 Rev Time 0.00
Received By hpiskura Date 2003-04-09 Time 13:52 Sent To  
Notes
2003-04-09 00:00:00THE PLANS ARE REQUIRED TO BE PREPARED BY
 A FLORIDA REGISTERED ARCHITECT OR
 ENGINEER.SEE FBC 101.4.2.
  
 AS PROVIDED FOR IN FBC 3401.7.2.6 WHEN
 THE REPAIR COST WILL EXCEED 50% OF THE
 VALUE OF THE BUILDING, THE BUILDING AND
 ITS SYSTEMS MUST COMPLY WITH THE CURRENT
 CODE.
  
 SEE FBC 104.3.1.1 FOR MINIMUM PLAN
 REVIEW CRITERIA AS WELL AS THE
 INFORMATION IN J.F. SHIELS, PE LETTER
 ADDRESSED TO THE BOARD OF APPEALS
 CHAIRMAN DATED 2/15/03.
  
 SOME, BUT NOT ALL OF THE CODE ISSUES
 ARE STRUCTURAL DESIGN LOADS
 VERTICAL HANDICAP ACCESSIBILITY
 STANDARDS, COMPONENT AND CLADDING
 PRESSURES, FIRE RESISTANT RATINGS, AND
 SPECIFIC REPAIR PROCEDURES.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-08-01 Cont ID  
Sent By btrobaug Date 2003-08-01 Time 12:59 Rev Time 1.00
Received By btrobaug Date 2003-07-31 Time 16:35 Sent To  
Notes
2003-08-01 00:00:00FAILED
 ~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE ADDRESS THE FOLLOWING COMMENTS
 AND RESUBMIT FOR REVIEW.
  
 1} PLEASE NOTE THAT ALL PLANS
 THAT ARE SIGNED AND SEALED BY ARCH/ OR
 ENGINEER ARE REQ`D PER 61G15-23.002 FOR
 ENGINEER AND 61G1-16.004 FOR ARCH.
 SHALL HAVE A TITLE BLOCK.
  
 2} REMOVE THE DISCONNECT THAT IS AHEAD
 OF THE METERS. FPL WILL NOT HOOK UP TO
 AN UNMETERED SERVICE.
  
 3} REDRAW RISER TO SHOW LOCATION OF
 RISER AND SERVICE CONDUCTOR SIZE.
  
 4} PLEASE RECALCULATE THE LOADS TO
 REFLECT THE CORRECT LIGHTING LOAD PER
 TABLE 220-3(A).*
  
 5} SHOW CONTINUOUS LOADS PER 210-19
 (125%) *
  
 6} LIST THE REQUIRED SIGN CIRCUIT PER
 600-5.*
  
 7} THE DEMAND FACTORS USED IN THE LOAD
 CALCULATION ARE FOR DWELLING UNITS AND
 ARE NOT ALLOWED TO BE USED IN
 COMMERCIAL APPLICATIONS.PLEASE
 RECALCULATE USING ALLARTICLES THAT
 APPLY.
  
 PLEASE SEE ATTACHED FLORIDA STATUTE 553.
 80(2)(B). * DENOTES COMMENTS ON PAST
 REVIEW.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-03-17 Cont ID  
Sent By alange Date 2003-07-23 Time 15:26 Rev Time 0.50
Received By btrobaug Date 2003-03-17 Time 16:07 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2003-05-14 Cont ID  
Sent By btrobaug Date 2003-05-14 Time 16:54 Rev Time 0.50
Received By btrobaug Date 2003-05-14 Time 16:23 Sent To  
Notes
2003-05-14 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 1} SHOW SUB PANEL LOCATIONS FOR EACH OFF
 ICE.
  
 2} PLEASE SHOW ALL CONTINUOUS AT
 125%. (LIGHTING ETC)
 215-2,215-3,230-42
  
 3} PLEASE LIST REQUIRED SIGN CIRCUITS PE
 R 600-5
  
 4} PLEASE SHOW HOW THE BATH RECEPTACLES
 COMPLY WITH 210-8(B).GFI.
  
 5} PLEASE NOTE THAT PLANS ARE TO
 BE SIGNED, DATED AND SEALED BY AN P.E.
 PER FS/FAC 553-79-6A.
  
 6} THE PANELS SHOWN ON THE RISER DIAGRAM
 DO NOT LIST THE OCP FOR THE FEEDERS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-05-15 Cont ID  
Sent By nmccray Date 2003-05-15 Time 14:15 Rev Time 0.00
Received By nmccray Date 2003-05-15 Time 14:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-03-21 Cont ID  
Sent By mcarsill Date 2003-03-21 Time 14:13 Rev Time 0.00
Received By mcarsill Date 2003-03-21 Time 14:13 Sent To  
Notes
2003-03-21 00:00:001) BUILDING ADDRESS NOT NOTED ON PROPER
 ELEVATION.
  
 2) PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATION INFORMATION FOR WALLS
 AND CEILINGS.
  
 3) NO INFORMATION PROVIDED ON ANY
 EXISTING EXIT SIGNS OR EMERGENCY
 LIGHTS.
  
 4) NO INFORMATION CONCERNING FIRE
 EXTINGUISHERS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-30 Cont ID  
Sent By alange Date 2003-07-23 Time 15:26 Rev Time 0.00
Received By alange Date 2003-07-23 Time 15:26 Sent To  
Notes
2003-07-30 00:00:00TO COMM BD #9

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-14 Cont ID  
Sent By shernand Date 2003-05-14 Time 11:43 Rev Time 0.00
Received By shernand Date 2003-05-14 Time 11:43 Sent To  
Notes
2003-05-14 00:00:00COMM BOARD #19

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-11 Cont ID  
Sent By dpalmer Date 2003-03-11 Time 14:01 Rev Time 0.00
Received By dpalmer Date 2003-03-11 Time 14:01 Sent To  
Notes
2003-03-11 00:00:00TO COMM BOARD #12

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2003-08-04 Cont ID  
Sent By pkrauss Date 2003-08-04 Time 11:17 Rev Time 0.10
Received By pkrauss Date 2003-08-04 Time 11:15 Sent To  
Notes
2003-08-04 00:00:00NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-04-09 Cont ID  
Sent By hpiskura Date 2003-04-09 Time 14:18 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2003-07-31 Cont ID  
Sent By kstevens Date 2003-07-31 Time 06:07 Rev Time 0.50
Received By kstevens Date 2003-07-31 Time 06:07 Sent To  
Notes
2003-07-31 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
 FLORIDA STATUTES
  
 1) FROM PREVIOUS REVIEWS: PER TABLE
 403.1 A DRINKING FOUNTAIN IS REQUIRED.
 ALSO SEE SECTION 410.1
 2) IF TOILET ROOM ARE PROVIDED THEN EACH
 PUBLIC AND COMMON USE TOILET ROOM SHALL
 COMPLY WITH 11-4.22 - 11-4.1.3(11).
 THE FOLLOWING INFORMATION NOT SHOWN ON
 PLANS. 11-4.16.5 FLUSH CONTROLS,
 11-4.19.2 HEIGHT & CLEARANCES, 11-4.19.3
 CLEAR FLOOR SPACE, 11-4.19.4 EXPOSED
 PIPES AND SURFACES, 11-4.19.5 FAUCETS,
 AND 11-4.22.3 AN UNOBSTRUCTED TURNING
 SPACE.
 3) NEW COMMENT: SHT 2, DOORS SHALL NOT
 SWING INTO THE CLEAR FLOOR SPACE REQUIR-
 ED FOR ANY FIXTURE.
 4) NEW COMMENT: SEE ATTACHED SHEET FOR
 ENGINEER'S TITLE BLOCK. 61G15-23.002
 5) FLORIDA STATUTE 553.80(2)(B)
 SEE ATTACHED SHEET. - INFORMATIONAL
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-05-30 Cont ID  
Sent By kstevens Date 2003-05-16 Time 08:42 Rev Time 0.50
Received By sgraham Date 2003-05-16 Time 08:42 Sent To  
Notes
2003-05-16 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) FROM PREVIOUS REVIEW: PER TABLE 403.1
 A DRINKING FOUNTAIN IS REQUIRED. ALSO
 SEE SECTION 410.1
 2) FROM PREVIOUS REVIEW: IF TOILET ROOMS
 ARE PROVIDED THEN EACH PUBLIC AND COMMON
 USE TOILET ROOM SHALL COMPLY WITH SEC
 11-4.22. - 11-4.1.3(11).PLEASE SUBMIT
 DETAILS FOR COMPLIANCE WITH 11-4.22 AND
 ALL SUBSECTIONS.
 3) FROM PREVIOUS REVIEW: IF BATHING
 ROOMS ARE PROVIDED, THEN EACH PUBLIC AND
 COMMON USE BATHROOM SHALL COMPLY WITH
 11-4.23. - 11-4.1.3(11) - PLEASE SUBMIT
 DETAILS FOR COMPLIANCE OF 11-4.23 AND
 ALL SUBSECTIONS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-03-22 Cont ID  
Sent By btrobaug Date 2003-05-14 Time 16:55 Rev Time 0.50
Received By kstevens Date 2003-03-22 Time 09:49 Sent To  
Notes
2003-03-22 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) SUBMIT A SANITARY RISER DIAGRAM AND
 A WATER RISER DIAGRAM PER FBC ADMIN.
 CODE SEC. 104.3.1.1
 2) PER TABLE 403.1 A DRINKING FOUNTAIN
 IS REQUIRED. ALSO SEE SECTION 401.1
 3) IF TOILET ROOMS ARE PROVIDED THEN
 EACH PUBLIC AND COMMON USE TOILET ROOM
 SHALL COMPLY WITH 11-4.22. 11-4.1.3(11)
 PLEASE SUBMIT DETAILS FOR COMPLIANCE
 WITH 11-4.22 AND ALL SUBSECTIONS.
 4) IF BATHING ROOMS ARE PROVIDED, THEN
 EACH PUBLIC AND COMMON USE BATHROOM
 SHALL COMPLY WITH 11-4.23. 11-4.1.3(11)
 PLEASE SUBMIT DETAILS FOR 11-4.23 AND
 ALL SUBSECTIONS.
 5) BACKFLOW REQUIRED ON WATER SERVICE.
 6) PLEASE PROVIDE CALCULATIONS FOR PRIM-
 ARY AND SECONDARY ROOF DRAINS PER SEC'S
 1106 AND 1107. INCLUDE 1/2 AREA OF ALL
 VERTICAL WALLS INCLUDING PARAPETS. SHOW
 LOCATION OF ALL PRIMARY AND SECONDARY
 ROOF DRAINS, AND INDICATE SQUARE FOOTAGE
 DRAINED BY EACH,
 7) PROVIDE A STORM RISER DIAGRAM.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2003-03-11 Cont ID  
Sent By sgraham Date 2003-03-11 Time 11:25 Rev Time 0.00
Received By sgraham Date   Time   Sent To I
Notes
***NONE***