Plan Review Stops For Permit 03030699 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-03-28 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-03-25 |
Time |
17:27 |
Rev Time |
3.00 |
Received By |
lsmith |
Date |
2003-03-28 |
Time |
11:02 |
Sent To |
|
|
Notes |
2003-03-28 00:00:00 | ****************PROVISO************* | | | | 1. STRUCTURE IS LOCATED IN AN AO FLOOD | | ZONE.AN ELEVATION CERTIFICATE IS | | REQUIRED AT TIME OF C/O. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-08-26 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-08-26 |
Time |
12:36 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-08-26 |
Time |
12:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-08-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-22 |
Time |
10:42 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-08-19 |
Time |
06:34 |
Sent To |
|
|
Notes |
2003-08-19 00:00:00 | *************** UNSAT ************** | | | | 1)NOTE: PLEASE COMPLETE RISER DIAGRAM | | TO INCLUDE PANEL. | | | | 2)NOTE: PLEASE VERIFY SIZE OF PANEL, | | SERVICE CONDUCTORS ARE SHOWN FOR A 200A | | SERVICE? | | | | 3)NOTE: PLEASE SEE THAT WASHER IS SHOWN | | AS OPTIONAL? PLEASE SEE 220.16 AND | | FBC/PLUMB. WASHER IS REQ'D AND MUST BE | | AVAILABLE. | | | | 4)NOTE: PLEASE SEE GROUNDING ELECTRODE | | CONDUCTOR, NOTE TO HOUSE STEEL, PLEASE | | SEE 250.50, THIS SHOULD NOTE TO FOOTER | | STEEL. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-03-24 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-18 |
Time |
10:30 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-03-24 |
Time |
08:19 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-08-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-22 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-08-22 |
Time |
10:42 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-08-18 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-18 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-18 |
Time |
10:29 |
Sent To |
E |
|
Notes |
2003-08-18 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-08-01 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-01 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-01 |
Time |
10:13 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-03-11 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-11 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-03-11 |
Time |
08:37 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-08-09 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2003-08-09 |
Time |
14:38 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2003-08-09 |
Time |
14:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-03-25 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-01 |
Time |
10:13 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-03-25 |
Time |
17:27 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-03-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-03-24 |
Time |
08:47 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2003-03-25 |
Time |
17:26 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-03-28 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-14 |
Time |
08:37 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
E |
|
Notes |
2003-03-28 00:00:00 | PER SG 3/14/03 LS |
|
|