Plan Review Stops For Permit 03030690 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2004-04-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2004-03-31 |
Time |
15:52 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
2004-03-31 |
Time |
15:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2004-01-27 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-03-31 |
Time |
11:33 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
2004-01-27 |
Time |
08:42 |
Sent To |
|
|
Notes |
2004-01-27 00:00:00 | DENIED | | | | 1) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) IN ADDITION TO THE PRODUCT APPROVAL | | FOR THE STORM PANELS, A KEY PLAN AND | | INSTALLATION SCHEDULE IS REQUIRED AT THE | | TIME THE PERMIT IS ISSUED. A SEPARATE | | PERMIT AND FEE WILL BE REQUIRED IF ALL | | INFORMATION IS NOT SUBMITTED WHEN THE | | PERMIT FOR THE STRUCTURE IS ISSUED. | | INDICATE THE TYPE OF MOUNT AND ANCHORS | | THAT WILL BE USED BY CIRCLING OR HIGH- | | LIGHTING THE APPROPRIATE ITEMS ON THE | | PRODUCT APPROVAL. | | | | 3) HAVE THE NEW SIGNED AND SEALED PLANS | | STAMPED BY THE COUNTY FOR IMPACT FEES. | | | | 4) CORRECT ITEMS FROM PLUMBING AND | | ELECTRICAL REVIEWS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-12-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-01-24 |
Time |
08:40 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
2003-12-05 |
Time |
15:17 |
Sent To |
M |
|
Notes |
2003-12-05 00:00:00 | DENIED | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 2) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 3) THE OWNER/AGENT IS REQUIRED TO SIGN | | THE ENERGY CALCULATION FORM. | | | | 4)PROVIDE (2) CURRENT AND COMPLETE | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | APPROVALS FOR: | | - STRUCTURAL WINDOW MULLIONS | | - INSWING METAL DOOR (THE ONE SUBMITTED | | IS FOR AN OUTSWING DOOR) | | - SLIDING GLASS DOOR ( THE ONE SUBMITTED | | IS NO LONGER VALID) SEE ATTACHED COPY OF | | CURRENT NOA. | | | | 5) SUBMIT A KEY PLAN AND INSTALLATION | | SCHEDULE FOR THE STORM PANELS OR APPLY | | UNDER A SEPARATE PERMIT. HIGHLIGHT OR | | CIRCLE THE TYPE OF MOUNTING AND ANCHORS | | THAT WILL BE USED ON THE PRODUCT | | APPROVAL. | | | | 6) REVISE THE WALL SECTION ON SHEET A1 | | TO INDICATE THAT THE FINISH FLOOR IS A | | MINIMUM OF 4" ABOVE FINAL GRADE AND THE | | BOTTOM OF THE FOOTER IS REQUIRED TO BE A | | MINIMUM OF 12" BELOW GRADE. SEE FBC | | 1804.1.3 AND CITY OF WPB AMENDMENTS TO | | FBC 1804.1.7. | | | | 7)1609.4.3 LOAD REDUCTION. | | WHEN STRUCTURAL EFFECTS DUE TO TWO OR | | MORE LOADS IN COMBINATION WITH DEAD LOAD | | ARE INVESTIGATED IN LOAD COMBINATIONS OF | | 1609.4.1 OR 1609.4.2, THE COMBINED | | EFFECTS DUE TO THE TWO OR LOADS MULTI- | | PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD | | LOADS SHALL NOT BE LESS THAN THE EFFECTS | | FROM THE LOAD COMBINATION OF THE DEAD | | LOAD PLUS THE LOAD PRODUCING THE LARGEST | | EFFECTS. INCREASES IN ALLOWABLE STRESS | | SPECIFIED IN THE MATERIALS SECTIONS OF | | THE CODE OR A REFRENCED STANDARD SHALL | | NOT BE USED WITH THESE LOAD COMBINATIONS | | EXCEPT THAT A DURATION OF LOAD INCREASE | | SHALL BE PERMITTED IN ACCORDANCE WITH | | CHAPTER 23. REVISE THE TRUSS ANCHOR | | UPLIFT VALUES LISTED ON A1 TO VALUES | | THAT DO NOT INCLUDE A ONE THIRD STRESS | | ON STEEL CALCULATIONS. SEE THE SIMPSON | | HIGH WIND RESISTANT CONSTRUCTION CATALOG | | SEE ATTACHED PAGE FROM CATALOG. | | | | 8) REVISE THE WINDOW/DOOR BUCK FASTENING | | SCHEDULE ON A4. FBC 1707.4.4.2 REQUIRES | | WINDOW AND DOOR ASSEMBLIES TO BE | | FASTENED THROUGH THE 1X BUCKS AND INTO | | THE STRUCTURAL SUBSTRATE. SEE NOTES ON | | THE PLAN. | | | | PLEASE SEE NOTATIONS ON THE PLANS. | | PLEASE RETURN OLD PLANS IN ORDER TO HELP | | EXPEDITE PLAN REVIEW. | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-04-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-11-25 |
Time |
18:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2003-12-05 |
Time |
11:17 |
Sent To |
|
|
Notes |
2003-04-07 00:00:00 | DENIED | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 2) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 3) ENERGY CALCULATIONS ARE REQUIRED TO | | BE SIGNED AND DATED BY THE OWNER/AGENT. | | | | 4)PROVIDE (2) CURRENT AND COMPLETE | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | APPROVALS FOR: | | - SINGLE HUNG WINDOWS | | - STRUCTURAL MULLIONS | | - ROOFING MATERIALS | | - SLIDING GLASS DOORS | | - INSWING METAL DOOR | | | | 5) THE CEILING AREA ON THE ENERGY CALCS. | | IS MORE THAN THE SQUARE FOOTAGE OF THE | | STRUCTURE AND NO TRAY OR VAULTED CEILING | | IS SHOWN ON THE PLANS. PLEASE CORRECT. | | | | 6) PROVIDE A KEY PLAN AND INSTALLATION | | SCHEDULE FOR THE STORM PANELS OR A | | SEPARATE PERMIT AND FEES WILL BE | | REQUIRED. | | | | 7) THE BOTTOM OF THE FOOTING IS REQUIRED | | TO BE A MINIMUM OF 12" BELOW FINISH | | GRADE PER FBC 1804.1.3. | | | | 8) THE BUILDING FLOOR ELEVATION AT THE | | PERIMETER OF A MONOLITHIC FOUNDATION AT | | HABITABLE AREAS SHALL BE A MINIMUM OF 4" | | ABOVE FINISH GRADE PER CITY AMENDMENTS | | TO FBC 1804.1.7. | | | | 9) INDICATE ON THE PLANS THAT THE WIRE | | MESH IN THE SLAB IS REQUIRED TO BE | | SUPPORTED ON APPROVED MATERIALS AT | | SPACINGS NOT TO EXCEED 3 FEET PER | | FBC 1909.3. | | | | 10) UNDER THE WIND DESIGN PRESSURES ON | | A1, PRESSURES ARE LISTED FOR A GARAGE | | DOOR. THERE IS NO GARAGE ON THE PLANS. | | PLEASE CLARIFY. | | | | 11) THE WALL SECTION ON A1 SPECS. 3- #5S | | IN THE FOOTING AND THE FOUNDATION PLAN | | SPECS. 2- #5S. PLEASE CORRECT. | | | | 12) ON THE WALL SECTION ON A1, THE NAIL | | SPACING FOR THE ROOF SHEATHING IS LISTED | | FOR THE TIN TAG SPACING. | | | | 13) THE SIMPSON HETA 20 CONNECTORS WITH | | 8-10D X 1-1/2" NAILS SPECIFIED ON THE | | WALL SECTION ON A1 FOR THE HIP TRUSSES, | | WILL NOT PROVIDE THE REQUIRED 1820# OF | | UPLIFT RESISTANCE. SEE 2003 SIMPSON | | CATALOG. AN HETA 20 WITH 10-16D NAILS | | FOR A 2 PLY TRUSS IS RATED FOR 1890# OF | | UPLIFT. THE JOB SPECIFIC CONNECTOR | | SCHEDULE ON A3 REFERS TO CONNECTOR #7 | | UNDER GENERAL NOTES FOR THE HIP TRUSSES. | | THIS IS A HETA 20 WITH 16-10D NAILS. | | PLEASE CLARIFY AND CORRECT. | | | | 14) SHEET A3 UNDER SPECIAL NOTES SPECS. | | +37.1 PSF AS WORST CASE DESIGN PRESSURE | | FOR COMPONENTS AND CLADDING. WHAT IS THE | | NEGATIVE WORST CASE PRESSURE? THE WIND | | DESIGN PRESSURES ARE GIVEN AS +36 AND | | - 48 PSF ON A1. UNDER DESIGN PARAMETERS | | ON A1 COMPONENTS AND CLADDING DESIGN | | PRESSURES ARE LISTED AS +35.3 AND - 47.2 | | PLEASE CORRECT. | | | | 15) FBC 1707.4.4.2 REQUIRES WINDOW AND | | DOOR ASSEMBLIES TO BE FASTENED THROUGH | | 1X BUCKS DIRECTLY TO THE STRUCTURAL | | SUBSTRATE. PLEASE REVISE WINDOW AND DOOR | | INSTALLATION CHART ON A4. | | | | 16) INDICATE THE INTERNAL PRESSURE | | COEFFICENT UNDER DESIGN PARAMETERS ON | | A1. FOR AN ENCLOSED STRUCTURE IT IS | | + OR - 0.18. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)659-8096 EXT.8202 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-03-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-03-25 |
Time |
15:25 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2004-03-25 |
Time |
14:56 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2004-01-23 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-03-19 |
Time |
12:43 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-01-23 |
Time |
08:30 |
Sent To |
P |
|
Notes |
2004-01-23 00:00:00 | ************** UNSAT ********** | | | | PLEASE SEE NOTE FROM FIRST TWO REVIEWS. | | | | 1)NOTE: PLEASE SEE COPY OF FS 553.80(2) | | (B). PLANS REVIEWED WITH SAME COMMENTS | | SUBJECT TO 4X FEE. | | | | 2)NOTE: PLEASE LIST THE REQUIRED DEDICAT | | -ED BATH(S) CIRCUIT(S) PER 210.52D AND | | 210.11C3. MUST BE SHOWN AS 20A AND #12 | | | | 3)NOTE: PLEASE STILL SEE NOTE ON RISER | | THAT MENTIONS AND SHOWS OVERHEAD CONDUCT | | -ORS FROM METER TO MAIN??? | | | | 4)NOTE: PLEASE SHOW LOCATION OF PANEL | | ON PLANS. | | | | 5)NOTE: PLEASE SEE MISSING RECEPTS PER | | 210.52 IN BEDROOMS AND MISSING RECEPT | | FRONT OF DWELLING PER 210.52E | | | | 6)NOTE: PLEASE SEE PLANS, DO NOT SHOW | | ELECTRICAL FOR WASHER/ DRYER/ WATER | | HEATER??? DISC FOR WH?? | | | | 7)NOTE: PLAN NOTE MENTIONS DISC REQ'D | | IF MORETHAN 8' BETWEEN METER AND PANEL. | | PLEASE SEE LOCAL AMENDMENTS. NOTE IS | | NOT CORRECT. | | LOCAL AMENDMENTS: 230.70A. A MAIN IS | | REQ'D ONLY WHEN THERE IS MORE THAN 8' | | OF UNPROTECTED(OCP) CONDUCTORS"INSIDE" | | THE BLDG. | | IF THERE ARE ANY QUESTIONS ON THIS, | | PLEASE CALL. | | | | 8)NOTE: PLEASE SEE LOAD SHOWN FOR A/C | | COND UNIT. SHOWS 1200 VA?? | | PLEASE ALSO VERIFY MAX OCP FOR 7.5 KW | | MIN 125% (424.3) AND MAX 150%. | | | | 9)NOTE: PLEASE SHOW CONDUCTORS AND | | POSSIBLE EQUIPMENT GRND ON LOAD SIDE | | OF METER AND MAINDISC IF INSTALLED. | | 250.110,250.24, 250.122 | | | | PLEASE ADDRESS ALL OF THE ABOVE COMMENTS | | IF PLANS COME BACK AND ANY OF THE SAME | | COMMENTS FROM PREVIOUS REVIEWS ARE NOT | | DONE, THEN A 4X FEE WILL BE ACCESED. | | PER FS 553.80(2)(B) ATTACHED. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-11-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-20 |
Time |
10:10 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-11-25 |
Time |
17:54 |
Sent To |
B |
|
Notes |
2003-11-25 00:00:00 | | | UNSAT | | ~~~~~ | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | PLEASE MAKE THE FOLLOWING REVISIONS TO | | THE PLAN FOR CODE COMPLIANCE AND | | RESUBMIT FOR REVIEW. | | | | 1} PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW EQUIPMENT BEING INSTALLED. | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | 2} PLEASE CLARIFY NOTE MENTIONING AND | | SHOWING OVERHEAD ELECTRIC THE METER AND | | THE DISCONNECT. | | | | 3} PLEASE NOTE KITCHEN COUNTER- | | -SPACE RECEPT SPACING SHALL MEET ART; | | 210-52C 1,2,3,4,AND 5. | | | | 4} MISSING SMOKE DETECTORS OUTSIDE OF | | TWO BEDROOMS. | | | | 5} LIST BATH RECEPTACLES PER | | 210.11(C)(3).#12,20 AMP. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-03-24 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-11-24 |
Time |
16:33 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-03-24 |
Time |
13:59 |
Sent To |
P |
|
Notes |
2003-03-24 00:00:00 | ************* UNSAT **************** | | | | 1)NOTE : PLEASELIST THE REQ`D ARC | | FAULT PROTECTED CIRCUITS ON PANEL | | SCHEDULE. 210-12 | | | | 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | NEW EQUIPMENT. MAINS/BRKRS AND PANEL | | ARE TO BE RATED FOR THE AVAIALBE FAULT | | CURRENT.110-9 | | | | 3)NOTE: PLEASE CLARIFY NOTE, MENTIONING | | THAT OVERHEAD ELEC BETWEEN METERAND | | MAIN DISC? | | | | 4)NOTE: PLEASE SEE PLANS, MISSING | | KITCHEN COUNTERSPACE RECEPTS PER | | 210-52-C-1, ALSO WALL RECEPTS PER | | 210-52. 2' OF WALL SPACE. | | | | 5)NOTE: PLEASE SEE MISSING SD`S OUTSIDE | | TWO OF THE BEDROOMS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2004-03-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-03-19 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-03-19 |
Time |
12:43 |
Sent To |
E |
|
Notes |
2004-03-19 00:00:00 | TO BT DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2004-01-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-20 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-20 |
Time |
10:09 |
Sent To |
E |
|
Notes |
2004-01-20 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-01-15 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-01-16 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-15 |
Time |
16:38 |
Sent To |
Z |
|
Notes |
2004-01-15 00:00:00 | TO RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-11-10 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-10 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-10 |
Time |
15:09 |
Sent To |
P |
|
Notes |
2003-11-10 00:00:00 | TO KS BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-11-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-06 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-06 |
Time |
11:47 |
Sent To |
E |
|
Notes |
2003-11-06 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-03-11 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-11 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-03-11 |
Time |
08:49 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-12-08 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-03-31 |
Time |
11:31 |
Rev Time |
0.33 |
Received By |
pkrauss |
Date |
2003-12-08 |
Time |
07:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-03-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2003-12-05 |
Time |
16:07 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-03-25 |
Time |
19:00 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2004-03-31 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-03-31 |
Time |
11:31 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-03-31 |
Time |
11:31 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2004-01-24 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-03-25 |
Time |
15:25 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-01-24 |
Time |
08:18 |
Sent To |
B |
|
Notes |
2004-01-24 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | CODE REQUIREMENTS, NOR DOES IT REFLECT | | THE FLOOR PLAN. | | A) BATH #2 TUB AND WATER CLOSET ARE NOT | | VENTED, AND THERE IS NO LAV. | | B) BATH #1 HAS TWO FIXTURES, (IDENTIFI- | | ED AS SINKS), AND FLOOR PLAN SHOWS ONE | | LAV. | | C) CLEANOUT REQUIRED AT 4' ABOVE THE | | FLOOR ON WASH MACHINE STACK. 708.10 | | D) WASH MACHINE REQUIRES A STANDPIPE | | PER 406.3 | | E) ALL PIPES SHALL BE SIZED | | F) THE WASH MACHINE AND KITCHEN SINK | | ARE NEAR EACH OTHER ON THE FLOOR PLAN, | | BUT ON OPPOSITE SIDES OF THE HOUSE ON | | THE SANITARY RISER DIAGRAM. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-01-23 |
Time |
08:32 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2003-11-24 |
Time |
16:33 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-03-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-10 |
Time |
15:09 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2003-03-25 |
Time |
19:01 |
Sent To |
B |
|
Notes |
2003-03-25 00:00:00 | DENIED; | | 1.RISER DIAGRAM DOESNOT MATCH FLOOR PLAN | | (BATHROOMS ARE NOT BACK TO BACK) | | 2.SIZE BUILDING DRAIN AND BRANCH LINES. | | 3.CLEANOUT TO BE WITHIN 3 FT. OF | | BUILDING. | | 4.SEWER TO PUBLIC SEWER NOT SEPTIC TANK. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 659-8096 EXT 8369 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2004-01-16 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-01-16 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-01-16 |
Time |
13:01 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2003-12-09 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-15 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2003-12-09 |
Time |
11:37 |
Sent To |
|
|
Notes |
2003-12-09 00:00:00 | DENIED, CANNOT HAVE A CIRCULAR DRIVEWAY | | NEED TO MOVE HOUSE 5-6FT BACK OR HAVE | | A 10FT STRAIGHT DRIVEWAY TO MEET THE | | 1000SQ FT OR 75% OF LANDSCAPE IN THE | | FIRST 25FT FRONT SETBACK CALLED LEFT | | MSG FILE J MM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-03-14 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-11 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
E |
|
Notes |
|
|