Plan Review Stops For Permit 03030326 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-03-12 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-03-12 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-03-12 |
Time |
09:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-05-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-05-06 |
Time |
07:02 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-05-06 |
Time |
07:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-03-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-03-17 |
Time |
06:20 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-03-17 |
Time |
06:19 |
Sent To |
|
|
Notes |
2003-03-17 00:00:00 | *************** UNSAT **************** | | | | 1)NOTE: PLEASE SEE TWO DIFFERENT AIC | | RATINGS FOR PANEL. RISER SHOWS 22K AND | | PANEL SHOWS 10K. PLEASE ALSO SUBMIT AIC | | RATING FOR NEW MAIN DISC PER 110-9. | | | | 2)NOTE; PLEASE CLARIFY LOAD CALCS, | | PLEASE SEE TWO DIFFERENT LOADS SHOWN? | | | | 3)NOTE: PLEASE CLARIFY USE OF MAINT BLDG | | AND ANY POSSIBLE LOCATIONS PER ART 500. | | 511? | | | | PLEASE NOTE, IT WAS REDLINED ONPLAN, | | AS PER LOCAL AMEDMENTS 215-5, FEEDERS | | FOR 277/480V ARE BROWN,PURPLE YELLOW(FYI | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2003-03-11 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2003-03-11 |
Time |
09:33 |
Rev Time |
0.50 |
Received By |
mamini |
Date |
2003-03-11 |
Time |
09:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2003-05-27 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2003-05-27 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-05-27 |
Time |
14:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2003-03-28 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-03-28 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-03-28 |
Time |
13:22 |
Sent To |
|
|
Notes |
2003-03-28 00:00:00 | 1) PLEASE EXPLAIN EXIT SIGNS AND | | EMERGENCY LIGHTS NEAR OVERHEAD ROLLING | | DOORS. THESE DOORS CANNOT BE USED FOR | | EXITING. PLEASE ADVISE. | | | | 2) PLEASE PROVIDE INTERIOR FINISH | | CLASSIFICATION FOR WALLS AND CEILINGS. | | | | 3) PLEASE INDICATE LOCATIONS OF FIRE | | EXTINGUISHERS. | | | | 4) WHAT TYPES OF MACHINES OR PROCESSES | | WILL BE STORED OR CONDUCTED IN THE | | BUILDING. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-06-02 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-02 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-02 |
Time |
16:08 |
Sent To |
P |
|
Notes |
2003-06-02 00:00:00 | KSTEVENS DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
|
Date |
2003-04-29 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-05-09 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-29 |
Time |
09:26 |
Sent To |
|
|
Notes |
2003-04-29 00:00:00 | COMM BOARD #14 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-03-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-03-06 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-03-06 |
Time |
14:09 |
Sent To |
|
|
Notes |
2003-03-06 00:00:00 | TO COMM BOARD #13 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-05-03 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-05-03 |
Time |
09:03 |
Rev Time |
0.20 |
Received By |
pkrauss |
Date |
2003-05-03 |
Time |
09:03 |
Sent To |
|
|
Notes |
2003-05-03 00:00:00 | PLANS APPROVED 3-18-03 - NO CHANGES | | ON THE RESUB. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-03-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-03-18 |
Time |
07:48 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2003-03-18 |
Time |
07:48 |
Sent To |
|
|
Notes |
2003-03-18 00:00:00 | PROVISO: | | | | IT APPEARS THAT ADDITIONAL MANUAL J | | SIZING CALCULATIONS WHERE SUBMITTED THAT | | DO NOT PERTAIN TO THIS PARTICULAR | | SPACE.PLEASE REMOVE CALCULATIONS THAT | | ARE NOT FOR THIS SPACE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2003-06-09 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-06-09 |
Time |
15:34 |
Rev Time |
1.25 |
Received By |
kstevens |
Date |
2003-06-09 |
Time |
15:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-05-27 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-02 |
Time |
16:08 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-05-27 |
Time |
08:57 |
Sent To |
|
|
Notes |
2003-05-27 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) FROM PREVIOUS REVIEW: SHT A1, SHOWER | | SHALL COMPLY WITH SECTION 11-4.21 AND | | ALL SUBSECTIONS. NO DETAIL GIVEN FOR | | SECTIONS 11-4.21.5 (CONTROLS), 11-4.21.6 | | (SHOWER UNIT), 11-4.21.7 (CURB). PLEASE | | PROVIDE DETAILS. | | 2) FROM PREVIOUS REVIEW: SHT P-1, I | | ACKNOWLAGE RESPONSE FOR THE RELIEF VALVE | | FOR THERMAL EXPANSION PROTECTION, BUT | | A VACUUM RELIEF VALVE IS REQUIRED FOR | | ALL BOTTON FED WATER HEATERS PER SECTION | | 504.2 | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-03-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-03-21 |
Time |
12:17 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2003-03-21 |
Time |
12:17 |
Sent To |
|
|
Notes |
2003-03-21 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) SHT A1, SHOWER SHALL COMPLY WITH | | SECTION 11-4.21 AND ALL SUBSECTIONS. | | PLEASE PROVIDE DETAILS. | | 2) SHT P1 WATER HEATER DETAIL, THE | | RELIEF VALVE SHALL NOT BE USED AS A | | MEANS OF CONTROLLING THERMAL EXPANSION. | | SECTION 504.5. PLEASE SHOW EXPANSION | | TANK TO COMPLY WITH 607.3.2 | | 3) BACKFLOW PREVENTOR REQUIRED ON WATER | | SERVICE. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-05-09 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-05-09 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|